You are on page 1of 1
HAY S BRIDGE | (WITH INBUILT OSCILLATOR AND DIGITAL NULL DETECTOR) EXPERIMENT-... Meg Pee ; : Using hay’s bridge ‘surement of unknown self eee of high quality factor 1 MAIN FEATURES OF THE BRIDGE. | EES OF THE BRIDGE. | foes decade resistance dial having value 10 x100KQ, 10x10kQ, <1kQ | jingle decade resistance dial having value 10 «1000, ‘Two fixed standard Capacitors havirig values 0.01pf and 0.02pf. ixed standard resistance having value 1000 ohm. Terminals are provided for external connections to connect unknown inductance and digital null detector or iiead phone | | FORMULA USED | L=QRC l Where R and Q are known standard resistances and C is a standard capacitor, PROCEDURE -- 1. Connect the unknown Inductance with digital null detector input terminals with 2. Set the capacitor C at 0.01 3. Switch on the instrument. 4. Now adjust the decade resistance dial R to minimize the readings in the digital null detector. ( minimum readings may be 0.00-0.20) Note value of R, C and Q. and calculate the value of unknown inductance ing above formula. 5 Repeat the above experiment at another value of capacitor C and resistance Q. the terminals marked unknown and the terminals Marked D, uf position and resistance Q say at 500 ohms. 5. NOTE — VALUE OF UNKNOWN INDUCTANCE IS — 1 Happ.