You are on page 1of 2

MAKING MODERN LIVING POSSIBLE

EvoFlat FSS,
fully insulated
Flat station for single - family, semi - detached and terraced
houses as well as flats
Flat station for direct heating and instantaneous domestic hot
water. Innovative self-acting TPC – M controller for control of
heating and DHW temperature. Designed for wall mounting or built
in wall.
Application
The EvoFlat is a compact and simple controller - the TPC - M. Supreme ease of FeATURES AND BENEFITS
to operate flat station. The EvoFlat is operation is obtained via the combined
especially suitable for two-pipe sys- hydraulic and thermostatic regulation
tems in residential buildings, which of the TPC - M controller. The flow - con- •• Flat station for decentralized heating
are supplied from a secondary con- trolled part allows primary and sec- systems
nected district heating system, a block ondary side flow through the heat ex-
•• Direct heating, DHW heating based
heating system or a centrally located changer, only when hot water is tapped on flow principle with thermostatic
boiler system. The EvoFlat is available and blocks the flow immediately after temperature controller
as built-in variant with a recess box or completion of the tapping process. The
•• Innovative, energy-saving controller
as mount-on-wall variant. thermostatic part controls the domestic
TCP - M in combination with high
hot water temperature. Thanks to the performance heat exchanger for on-
Primary side (HS)
quick-acting hydraulic control of the demand water heating without no-load
The flat station is prefabricated with heat exchanger, it is largely protected losses
interconnecting components such as from the formation of lime scale and
a differential pressure controller (inte- •• Capacity: 15 kW HE, 55 kW DHW
growth of bacteria. The TPC  -  M control-
grated in main temperature controller ler with integrated differential pressure •• Minimum space required for installation
TPC -M ), strainer, sensor pockets and controller compensates for variations •• Built-in or wall-mounted variant
fitting piece for insertion of a heat me- in supply temperature and varying dif-
ter. Thermostatic bypass is available as •• Pipes and plate heat exchanger made of
ferential pressure and thereby ensures a stainless steel
an option. constant domestic hot water tempera-
ture at all times. For registration of the •• Minimized risk of lime scale and bacteria
Heating (HE) formation
cold water consumption the EvoFlat is
The self-acting temperature controller
equipped with a fitting piece for mount-
TPC - M with integrated differential
ing of a cold water meter in the DCW duced heat losses and excellent oper-
pressure controller sets the optimum
inlet. ating economy.
operating conditions for heating and
DHW. In order to enable a time depen- Construction
dent temperature control program, a All pipes are made of stainless steel.
zone valve with actuator and a room The connections are made by a newly
thermostat can be included as an op- designed click connection, which does
tion. not need retightening
Domestic hot water (DHW) Insulation
The domestic hot water is prepared The EvoFlat is built up on an EPP in-
in the heat exchanger based on the sulation back plate and a front insula-
flow principle and the temperature is tion cabinet is available as an option,
regulated by the self-acting controller enabling the customer to have a fully
with integrated differential pressure insulated substation, thus ensuring re-

districtenergy.danfoss.com
EvoFlat FSS, fully insulated
Circuit diagram – example
2 Plate heat exchanger Danfoss
XB06H -1
5 Strainer 3/4” N/ N mv=0,6 mm
23 Sensor pocket 1 /2”
24 Fitting piece for energy meter
3/4” x 110 mm
DHW 38 Hot Water Controller TPC - M
40 By-pass/circulation Danfoss
FJVR (optional)
59 Fitting piece for water meter
DCW 3/4” x 110 mm

DCW

HS HE
Supply Supply

HS HE
Return Return

Design specifications: Connections:


Nominal pressure (prim/sec.): PN 10 / PN 10 1. Domestic cold water (DCW) inlet
Max. supply temperature: 95 °C 2. Domestic hot water (DHW)
DCW static pressure: Pmin = 1.0 bar 3. Domestic cold water (DCW) outlet
Brazing material (HEX): Copper 4. Primary side (HS) supply
580 mm

Weight excl. cover: 10 kg 5. Primary side (HS) return


6. Heating (HE) supply
Insulation: EPP λ 0.039 7. Heating (HE) return
Cover: White-lacquered steel Options:
• Room thermostat
910 mm

Electrical supply: 230 V AC


• Actuator for zone valve
Dimensions (mm):
• Safety valve
With connections: H 590 × W 550 × D 150* • Ball valves (60 mm)
* Depth incl. mounting plate • Ball valves with connection for pressure
Connections sizes: gauge ¾“ (120 mm) incl. safety valve
DH, HE, DHW, DCW: G ¾“ ET (int. thread) 1 2 3 4 5 6 7 • Mounting rail for wall mounted variant
• Recess box for built-in variant incl.
65 mm 65 mm 65 mm 65 mm 65 mm 65 mm
mounting rail
• Bypass
• Isolated front cover
610 mm

DHW: Capacity examples Heating: Capacity examples


DHW Temperature Temperature Flow rate Flow rate Pressure loss Heating Total pressure Flow rate
capacity Type primary secondary primary secondary primary Heating circuit Δt loss primary primary
[kW] [°C] [°C] [l/h] [l/h] [*kpa] capacity [°C] [*kpa] [l/h]
37 1 65/19,1 10/45 707 910 16 10 20 3 430
37 1 65/22,4 10/50 762 796 18 10 30 1 287
37 2 65/16,8 10/45 673 910 12 10 40 1 215
45 2 65/17,6 10/45 833 1106 18 15 20 8 645
37 2 65/19,6 10/50 714 796 14 15 30 3 430
45 2 65/20,6 10/50 890 968 21 15 40 1,5 323
55,5 3 65/14 10/45 950 1365 41
* Energy meter not incl.
53 3 65/15,8 10/50 950 1140 41
Type 1 = XB 06H-1 26 (plate heat exchanger)
42 3 55/16,3 10/45 950 1033 41 Type 2 = XB 06H-1 40 (plate heat exchanger)
33,7 3 50/19,1 10/45 950 829 41 Type 3 = XB 06H+ 60 (plate heat exchanger)

* Energy meter not incl.

Danfoss Redan A/S · District Heating · Omega 7, Søften · DK-8382 Hinnerup · Denmark
Tel.: +45 87 43 89 43 · Fax: +45 87 43 89 44 · redan@danfoss.com · www.redan.danfoss.dk

VL.IE.Z1.02 © Danfoss 08/2013 DEN – SMT / PL