You are on page 1of 1

Electrical Report - P481T6560 - BNY0121

System Information
Full Load Amps: 11.8
Required kW: 10.6
Required Generator HP: 17.0
Voltage at MCP: 380.0
Minimum Voltage: 361.0
Electrical Frequency: 50 Hz

Flanged Side

Location Type Length Amps Total Amps kW Voltage KVA Cable


PivotCenter NoMotor 0.0 0.0 11.7 0.0 380.0 7.7
Tower1 Standard 175.0 0.9 11.7 0.8 377.7 7.7 10C/0s/#8
Tower2 Standard 175.0 0.9 10.9 0.8 375.6 7.1 10C/0s/#8
Tower3 Standard 194.0 0.9 10.0 0.8 373.5 6.5 10C/0s/#8
Tower4 Standard 194.0 0.9 9.1 0.8 371.5 5.9 10C/0s/#8
Tower5 Standard 194.0 0.9 8.2 0.8 368.7 5.3 10C/0s/#10
Tower6 Standard 194.0 0.9 7.4 0.8 366.1 4.7 10C/0s/#10
Tower7 Standard 194.0 0.9 6.5 0.8 363.9 4.1 10C/0s/#10
Tower8 Standard 194.0 0.9 5.6 0.8 362.0 3.5 10C/0s/#10
BoosterPump/Max TwoHP 62.0 4.8 4.8 3.8 361.5 3.0 /#10

Complete system designs may be dependent upon factors not considered by this program. Reinke
Manufacturing Co., Inc. assumes no liability for the use of design metrics, including, but not limited to,
wire or pipe sizes, determined by using this program.

Electrical Report iulie 27, 2020


Dealer: BNY Holding LTD Page 1 of 1
Customer: BNY0121 - MOLDOVA FARMING