F.03-09 Job Safety Analysis - Use of Air Compressor
F.03-09 Job Safety Analysis - Use of Air Compressor
C
Abu Dhabi – UAE
No RESPONSIBLE
STEPS PREVENTIVE MEASURES PERSONS
Prepare for Use
1. Make sure the area is well-ventilated. Wear a mask. Foreman
Hazards:
Inhalation of Toxics
Do not smoke while spraying or spray where spark or flame is present.
Keep the compressor at least 20 feet away from spraying area and all
explosive vapors.
Use eye protection.
Do not touch moving parts.
Keep all guards or covers in place or do not use if guards or covers are
broken.
Do not operate without proper safety valve in place
Use of air compressor Do not adjust a regulator to result in output pressure greater than marked
maximum pressure.
Hazards: Do not weld on or repair the air tank.
Foreman/
2. Risk of Fire or Explosion Replace damaged tank immediately.
Mechanic/Helper
Risk of Bodily Injury Use properly grounded electrical connections.
Risk of Bursting Do not use grounding adaptors.
Risk of Electrical Shock Personnel should never use compressed air to clean themselves or their
clothing.
If there is a risk of particulates/debris flying back into the operator’s face, it
is recommended to use air nozzles/guns.
Equip nozzle with chip guards or that generate air curtains around the
nozzle to reduce fly back.
Never participate in horseplay with compressed air.
Never point an air nozzle/gun or direct its airstream towards another
individual.