Installation
Mounting
2023-04-13
1 Safety
General safety instructions
1 Safety
Hazard symbol
This symbol indicates risks of injury.
Instructions associated with this symbol to prevent any risk of injury or
death must be strictly adhered to at all times.
Battery Heat
Severity
The potential severity is defined in the following table:
2|9 A6V12344947_en--_a
Safety 1
Specific safety instructions
WARNING
Type and cause of the risk
Consequences if the risk occurs
● Preventive actions / prohibitions
NOTICE
Type and cause of the risk
Consequences if the risk occurs
● Preventive actions / prohibitions
WARNING
Potential personal injury and/or property damage
Follow all safety instructions provided in this document.
1.3 Standards
Siemens products are developed and manufactured in accordance with specific
applicable European and international safety standards. If additional national safety
standards or regulations related to the configuration, mounting, installation, use or
disposal of the product apply to the operating site, these standards or regulations
must be complied with in addition to the safety requirements provided in the
product documentation.
A6V12344947_en--_a 3|9
2 Installation procedure
Technical data
2 Installation procedure
NOTICE
Installation room
Install the product in a room that meets the requirements specified in the
NF S61-932 standard.
Make sure that the installation room meets the following requirements:
● The floor is flat, smooth and level.
● The temperature is stable and is not exposed to large variations.
● The room is not exposed to strong magnetic fields.
● The room is not exposed to corrosive gases or chemicals.
● Ensure that the controls and indicators are accessible and clearly visible. To do
this, mount the products in the rack, not lower than 700 mm and not higher
than 1,800 mm, as illustrated below.
4|9 A6V12344947_en--_a
Installation procedure 2
Choosing where to install the rack
Cover plate 3U
Plaque de fermeture 3U
1,800 mm
Rack door 6U
Plaque de fermeture 3U
Ou
Alimentation AES
700 mm
Cover plate 6U
2.4 Installation
CAUTION
Tip over hazard
If the rack is delivered on a palette, it must be carried to the installation location
by two people.
A6V12344947_en--_a 5|9
3 Mounting the MGB30 module
Preparation
3.1 Preparation
Tools
Use the following tooling:
● Phillips screwdriver
● 4x M6x16 screws
● 4x caps for M6x16 screws
Dimensions
Height 266 mm (6U)
3.2 Mounting
CAUTION
Tip over hazard
To prevent the rack from tipping over and to avoid potential injuries, it is
recommended to have the module mounted in the rack by two people.
1. Make sure that the location chosen to mount the product in the rack is large
enough (6U).
2. On the product, measure the distance between the holes for the mounting
screws.
3. On the rack, insert the 4 clip nuts in the openings of the vertical rails of the rack
(use the distance measured on the product).
4. Place the product in the rack, aligning the screw holes with the clip nuts on the
rack.
5. Insert a cap on each M6x16 screw.
6. Insert two screws in the holes on the hinge side of the product.
7. Tighten the screws to the stop.
8. Connect the cables.
9. Insert the two remaining screws in the holes on the opposite side of the
product.
10. Tighten the screws to the stop.
6|9 A6V12344947_en--_a
Mounting the STTM2002-F2 module 4
Preparation
4.1 Preparation
Tools
Use the following tooling:
● Phillips screwdriver
● 4x M6x16 screws
● 4x caps for M6x16 screws
Dimensions
Height 133 mm (3U)
4.2 Mounting
CAUTION
Tip over hazard
To prevent the rack from tipping over and to avoid potential injuries, it is
recommended to have the module mounted in the rack by two people.
1. Make sure that the location chosen to mount the product on the rack is large
enough (3U).
2. On the product, measure the distance between the holes for the mounting
screws.
3. On the rack, insert the 4 clip nuts in the openings of the vertical rails of the rack
(use the distance measured on the product).
4. Place the product in the rack by aligning the screw holes with the clip nuts on
the rack.
5. Insert a cap on each M6x16 screw.
6. Insert two screws in the holes on the hinge side of the product, through to the
clip nuts on the rail.
7. Tighten the screws to the stop.
8. Connect the cables.
9. Insert the two remaining screws in the holes on the opposite side of the
product, through to the clip nuts on the rack.
10. Tighten the screws to the stop.
A6V12344947_en--_a 7|9
5 CE certifications
5 CE certifications
Certification body: AFNOR Certification - 11 rue Francis de Pressensé - FR-93571 LA PLAINE SAINT DENIS CEDEX
8|9 A6V12344947_en--_a
Issued by
Siemens SAS
Smart Infrastructure
15-17, avenue Morane-Saulnier
FR-78140 VELIZY-VILLACOUBLAY
+33 1 85 57 01 00
www.siemens.com/buildingtechnologies
© Siemens 2021