Professional Documents
Culture Documents
Switches Industriais Delta DVS
Switches Industriais Delta DVS
WWW.KALATEC.COM.BR
w w w. d e l t a w w. c o m
Matched to Maximize
1
Table of Contents
Ethernet Switches
1 Industrial Ethernet Products and Solutions
Tailoring to industrial applications that require highly reliable network
systems, Delta's DVS series managed and unmanaged Ethernet
switches provide better system performance with functions such as
the redundant self-healing ring, high-end layer 2 management, and
3 Industry
a wide-operating temperature from -40°C to 75°C. The EMC noise Intelligent Transportation System
immunity complies with Wind Power
IEC standards and
RGV Intelligent Warehouse Carriage
attains a high level 3/4. Automation System
The intuitive design of
the operating interface Solar Power
provides users with easy Automated CNC Production Line
access and convenience.
13 Ethernet Switches
Feature-rich Layer 2+/3 Network
Management
Layer 3 Managed Switches
Managed Switches
Unmanaged Switches
Wireless IEEE 802.11 PoE Managed Switches
Delta helps users construct a reliable industrial wireless network by
PoE Unmanaged Switches
the WLAN products compatible with multiple communication protocols,
such as IEEE 802.11 a/n in 5GHz or IEEE 802.11 b/g/n in 2.4GHz. Ethernet-to-Fiber Media Converters
Adopting Multiple-input and Multiple-output (MIMO) technology SFP Fiber Transceivers
enables the network bandwidth reach 450Mbps. Delta WLAN products
support multiple wireless connectors, including wireless access points,
WDS, and clients for easy and economical construction of wireless 76 IEEE 802.11 WLAN
LANs. The built-in 3-in-1 serial ports directly connect to industrial
Wireless Management
controllers, saving the effort and cost of
cable connection. The built-in gateway Wireless AP
for MODBUS, the most common High-gain Antennas
industrial communication protocol,
converts MODBUS Serial to MODBUS
TCP, seamlessly interconnecting the 90 IIoT Routers
existing equipment with the Ethernet DIACloud Cloud Routers
communication network.
VPN Routers
2
Industry
ALARM
1
2 1 PWR1
RESET
3 2 PWR2
4
3 DI1
4 DI2
DVS-11
GE8 0W02-3
100/
SFP
10/100
1000M /1000M
LINK
ACT
LINK 1
GE9
ACT
2/5
GE10
DVS-110W02-3SFP
3/6
CONSO 10/
LE 100M
4/7
LINK
ACT
Exhaust Blower
► STP / RSTP / MSTP for network Fire Alarm
888 8
Air Detector
SV
operating temperature
8888
HMI
AT OUT ALM
SET
Temperature Sensor
Smoke Sensor
DVW-W02W2-E2
IEEE 802.11 a/b/g/n Wireless AP
► IEEE 802.11n up to 450Mbps data rate
Vehicle Detector
► Supports 2-port RS-232 / 422 / 485 to DVS-110W02-3SFP
IIoT Routers
3
ALARM
2 1 PWR1
2 PWR2
RESET
4
3 DI1
4 DI2
DVS-11
LINK
ACT
LINK 1
GE9
ACT
2/5
GE10
operating temperature
3/6
CONSO 10/
LE 100M
Visibility Sensor
4/7
LINK
ACT
RTU-EN01
IFD9506
1-Port MODBUS-to-Ethernet Converter
3
Industry
GbE Fiber
Ethernet
Serial
I/O Sensor
DVS-110W02-3SFP
Ethernet Switches
1
3
ALARM
2
4
1 PWR1
2 PWR2
3 DI1
4 DI2
GE8
100/
RESET
10/100
DVS-11
0W02-3
SFP
DVW-W02W2-E2
1000M /1000M
LINK
ACT
LINK 1
GE9
ACT
2/5
GE10
3/6
CONSO 10/
LE 100M
1
4/7 Antenna
LINK
ACT 2
DVW-W0
2W2-E2 3
TR1 OFF
ON
PWR2 TXD- ON
RX RXD-
(D-) TXD TXD+
COM2 COM1 DCD
RX TX GND RXD+
DTR (D+)
RS-422/485
CLIENT RXD
RS-232
COM2
MODE TX RXD-
AP/BRIDGE GND (D-) TXD
ALARM MODE
DSR GND
DTR
RS-232
RTS
GND
CTS
DSR
RTS
CONSOLE
10/100/ CTS
1000M
LAN1 10/100/
1000M
DVW-W02W2-E2
RESET
LAN2
LINK
/ ACT
LINK
/ ACT
IFD9506
1
Antenna
DVW-W0
2W2-E2 3
TR1 OFF
ON
ON
ETHERNET
PWR2 TXD-
RS-232
RS-485
RX RXD-
(D-) TXD TXD+
COM2 COM1 DCD
RX TX GND RXD+
DTR (D+)
RS-422/485
CLIENT RXD
RS-232
COM2
MODE TX RXD-
AP/BRIDGE GND (D-) TXD
ALARM MODE
DSR GND
DTR POWER
RS-232
RTS
GND
DATA
SLAVE ADDRESS FORMAT BAUDRATE
CTS
DSR
DVS-110W02-3SFP
RTS POWER
CONSOLE
10/100/ CTS
POWER S/S
1000M
RUN X0 RUN
RS-485
ERROR
88
LAN1 10/100/ X1
1000M ALARM
COM1 X2
ID 7
RESET
LAN2
IN X3
1 2 3 4 5 6 7 8
DIP
LINK
/ ACT
RUN
X4
ID 6
X5
LINK X6
RS485 RSSET LINK/ACT ID 5
/ ACT
ID 4
IP CAM
STOP X7
ID 3
C0
ID 2
RTU-485
Y0
ID 1
DVP-12SE
ON
COM1 OUT Y1
Y2 ID 0
1
10
Y3
24V
S/S
SC
D-
D+
X2
X1
X0
0V
SG
COM3+
COM3-
PA 3
1 2 3 4 5 6 7 8
DIP
PA 2
RTU-485
PA 1 ALARM
PA 0
1
2 1 PWR1
RESET
3 2 PWR2
DR 2 4
100/ 10/100
A/R 1000M /1000M
LINK
ACT
LINK 1
GE9
ACT
3/6
CONSO 10/
LE 100M
4/7
LINK
ACT
IIoT Routers
IP CAM
DVS-G008W01
10/100
/1000M
DVS-008W
01
Traffic Lights 4
LINK
ACT
ALARM
8
PWR1
PWR2
ALARM
1
2 1 PWR1
RESET
3 2 PWR2
4
3 DI1
4 DI2
DVS-110
GE8
W02-3SF
100/ 10/100 P
1000M /1000M
LINK
ACT
LINK 1
GE9
ACT
2/5
GE10
3/6
CONSOL 10/
100M
E
4/7
LINK
ACT
DVS-110W02-3SFP
4
Industry
Wind Power
Wind power has emerged as an alternative energy solution in recent years. Wind power plants are
typically located in remote areas, often within a vast territory. The ring network of fiber optic Ethernet is
widely adopted for data transmission and management and real-time monitoring of power generation
panels. These plant locations can be harsh and hazardous, with a large diurnal temperature variation.
System reliability and transmission precision can only be guaranteed with highly noise-immune and
durable network devices.
Ethernet Switches
DVS-110W02-3SFP
Managed 10-Port Ethernet Switch
► GbE fiber port to enhance backbone
transmission
► STP / RSTP / MSTP for network
redundancy to ensure network reliability
IEEE 802.11 WLAN
DVS-016 Series
Unmanaged 16-Port FE Ethernet Switch
► Broadcast Storm Protection
► Auto warning for link-down and power
failure by relay output
► IP40 metal case, -40°C to 75°C
IIoT Routers
operating temperature
Control Center
ALARM
1
2 1 PWR1
RESET
3 2 PWR2
4
3 DI1
4 DI2
DVS-1
GE8 10W02
-3SFP
100/ 10/100
1000M /1000M
LINK
ACT
LINK 1
GE9
ACT
2/5
GE10
3/6
CONS 10/
OLE 100M
4/7
LINK
ACT
DVS-110W02-
3SFP
ALARM
1
2 1 PWR1
RESET
3 2 PWR2
4
3 DI1
4 DI2
DVS-1
GE8 10W02
-3SFP
100/ 10/100
1000M /1000M
LINK
ACT
LINK 1
GE9
ACT
2/5
GE10
3/6
CONS 10/
OLE 100M
4/7
LINK
ACT
DVS-110W02-3SFP
5
Industry
GbE/FE Fiber
Ethernet
Serial
Ethernet Switches
Hot Swappable
DVS-016W01-MC01 Mid-range PLC
AH500 Series
PORT ALARM
12
2 7
13
8
3
14
9
4 100M
15
10
LINK
ACT
16
IIoT Routers
DVS-110W02-3SFP Network Type Advanced Slim PLC
DVP-SE Series
ALARM
1
2 1 PWR1
RESET
3 2 PWR2
4
3 DI1
4 DI2
POWER S/S
DVS-1
GE8 10W02
-3SFP
RUN X0
100/ 10/100
1000M /1000M ERROR X1
LINK COM1
ACT X2
IN X3
LINK 1
GE9 X4
ACT
RUN
X5
X6
ALARM
2/5
STOP X7 1
2 1 PWR1
RESET
GE10 3 2 PWR2
4
C0 3 DI1
4 DI2
Y0 DVS-1
GE8
DVP-12SE
10W02
3/6
COM1 OUT Y1 100/
-3SFP
10/100
1000M /1000M
Y2
LINK
Y3 ACT
CONS 10/
OLE 100M
LINK 1
GE9
SG ACT
4/7
COM3+
LINK COM3-
ACT
2/5
GE10
3/6
Ethernet
R
CONS 10/
OLE 100M
ALARM
1
2 1 PWR1 4/7
RESET
3 2 PWR2
4
3 DI1 LINK
ACT
4 DI2
DVS-1
GE8 10W02
-3SFP
100/ 10/100
1000M /1000M
LINK
ACT
LINK 1
GE9
ACT
2/5
GE10
CONS
OLE
3/6
10/
100M
DVS-110W02-3SFP
4/7
LINK
ACT
DVS-110W02-3SFP
ALARM
1
2 1 PWR1
RESET
3 2 PWR2
4
3 DI1
4 DI2
DVS-1
GE8 10W02
-3SFP
100/ 10/100
1000M /1000M
LINK
ACT
LINK 1
GE9
ACT
2/5
GE10
3/6
CONS 10/
OLE 100M
4/7
LINK
ACT
DVS-110W02-3SFP
Rectifiers RTU-EN01 Inverters
6
Industry
capability. When applying the Delta DVW series and LCX to Rail Guided Vehicle (RGV) systems,
they can assist factory operators carry materials, which enhances working efficiency and security for
maintenance personnel.
DVW-W02W2-E2
IEEE 802.11 a/b/g/n Wireless AP
► IEEE 802.11n up to 450Mbps data rate
► Supports 2-port RS-232/422/485 to
Ethernet Device Server
► IP40 metal case, -40 to 75°C operating
temperature
IIoT Routers
AH500 Series
Hot Swappable Mid-range PLC
RGV
► Utilizes 32-bit processor
► Max. I/O points:
DIO: Max. 4,352 points
AIO: Max. 544 channels
RIO: >100,000 points
► Program capacity: Max. Hot Swappable Mid-range PLC
384 k steps (1.5 MB) AH500 Series Master
DVW-W02
W2-E2 3
TR1 OFF
ON
PWR2 TXD- ON
RX RXD-
(D-) TXD TXD+
COM2 COM1 DCD
RX TX GND RXD+
DTR (D+)
RS-422/485
CLIENT RXD
RS-232
COM2
MODE TX RXD-
AP/BRIDGE GND (D-) TXD
ALARM MODE
DSR GND
DTR
RS-232
RTS
GND
CTS
DSR
LAN1 10/100/
1000M
RESET
LAN2
LINK
/ ACT
LINK
/ ACT
7
Industry
Ethernet
Coaxial Cable
Leaky Coaxial Cable
Ethernet Switches
DVW Series AP Mode Hot Swappable Mid-range PLC SCADA
AH500 Series Master
1
Antenna
DVW-W
02W2-E 3
TR1 OFF 2
ON
PWR2 TXD- ON
RX RXD-
(D-) TXD TXD+
COM2 COM1 DCD
RX TX GND RXD+
DTR (D+)
RS-422/485
RXD
RS-232
CLIENT COM2
MODE TX RXD-
AP/BRIDG GND (D-) TXD
ALARM MODE E DSR GND
DTR
RS-232
RTS
GND
CTS
DSR
RTS
CONSOLE
10/100/ CTS
1000M
LAN1 10/100/
1000M
RESET
LAN2
LINK
/ ACT
LINK
/ ACT
100M
Leak
y Coa
xial C
able
Obstruction
IIoT Routers
RGV
1
Antenna
DVW-W
02W2-E 3
TR1 OFF 2
ON
PWR2 TXD- ON
RX RXD-
(D-) TXD TXD+
COM2 COM1 DCD
RX TX GND RXD+
DTR (D+)
RS-422/485
RXD
RS-232
CLIENT COM2
MODE TX RXD-
AP/BRIDG GND (D-) TXD
ALARM MODE E DSR GND
DTR
RS-232
RTS
GND
CTS
DSR
RTS
CONSOLE
10/100/ CTS
1000M
LAN1 10/100/
1000M
RESET
LAN2
LINK
/ ACT
LINK
/ ACT
8
Industry
Solar Power
Governments worldwide actively seek renewable clean energy for their electricity infrastructure
in recent years. Solar power systems are one of the main programs. Most solar power plants are
located in remote, vast areas of a country. The monitoring system constructed by Industrial Ethernet
establishes highly stable and multiple redundant network systems for a power plant. It also facilitates
real-time monitoring and continuous production by the highest generating capacity.
Ethernet Switches
DVS-108W02-2SFP
Managed 8-Port Ethernet Switch
► GbE fiber port to enhance backbone transmission
► ONE RING, ONE CHAIN for rapid IP Camera
network redundancy to ensure
network reliability , recovery time
less than 20ms
► IP40 metal case, -40°C to 75°C
1
2
O
N
PWR1
PWR2
ALARM
operating temperature
7
DVS-G408W01
5
3
IEEE 802.11 WLAN
PoE 10/100/1000M
1
DVS-G408W01
PoE+ Unmanaged 8-Port GbE Ethernet Switch
► 8 10 / 100 / 1000 Base-T PoE+ (PSE) ports.
Based on IEEE 802.3at standard up to
30 W per port
POWER S/S
RUN X0
ERROR X1
COM1 X2
IN X3
X4
RUN
X5
X6
STOP X7
DVP-12SE
COM1 OUT Y1
Y2
Y3
SG ALARM
COM3+ 1
2 1 PWR1
COM3- RESET
3 2 PWR2
4
3 DI1
4 DI2
DVS-10
8W02-2
power failure
SFP
Ethernet
R
GE7
100/ 10/100
1000M /1000M
LINK
ACT 1/4
GE8 LINK
ACT
2/5
3/6
LINK
ACT
operating temperature
IIoT Routers
DX-3021L9
4G Cloud Router
► LTE FDD / LTE TDD / DC-HSPA /
UMTS / EDGE / GPRS / GSM
► Supports DIACloud Cloud Management POWER
RUN
ERROR
COM1
S/S
X0
X1
IN X3
X2
X4
RUN
X5
X6
Platform
STOP X7
C0
Y0
DVP-12SE
COM1 OUT Y1
Y2
Y3
SG
COM3+
COM3-
(DC/AC)
SFP
operating temperature
GE7
100/ 10/100
1000M /1000M
LINK
ACT 1/4
GE8 LINK
ACT
2/5
CONSO 10/
LE 100M
3/6
LINK
ACT
DVP-SE
Battery Bank
9
Industry
GbE Fiber
Ethernet
Power Line
Ethernet Switches
10/100M LINK/ACT 100M LINK/ACT 10/100/1000M LINK/ACT 100/1000M LINK/ACT
1 3 5 7 9 11 13 15 17 19 21 23 21 23 25 27 25 27
PWR1
DVS-328R02-8SFP R.M / CPLG.R
PWR2 ALARM
PWR1 PWR3
PWR3 DI
-/N +/L 0V V+ CONSOLE
1 3 5 7 9 C.HD / C.TL
2 4 6 8 10
0V V+
RESET
PWR2
V+ V- 2 4 6 8 10 12 FE 14 16 18 20 22 24 FE Combo 22 24 26 28 GE Combo 26 28
ALARM DI
Managed Switch
(DVS-300 Series)
POWER
READY ANT
USB
PoE+ switch
RS232
RS485
RS485
SD
D+
SIM1 D-
SIM2
GND
(DVS-G400 Series)
RXD
DX-3021
TXD
GND
USB
RTS
CTS
RS232
SIM1
WAN
1
2
Remote Control Center
SIM2
10/
100M
LINK 4
ACT
LAN
POWER
READY ANT
USB
RS232
RS485
RS485
SD
D+
SIM1 D-
SIM2
GND
RST
4G Cloud Router
RXD
DX-3021
TXD
GND
USB
RTS
CTS
RS232
SIM1
WAN
( DX-3021L9 Series)
SIM2
10/
100M
LINK 4
ACT
LAN
Network Type 1
ALARM
2 1 PWR1
RESET
(DVP-SE Series)
GE7
100/ 10/100
1000M /1000M
LINK
ACT 1/4
GE8 LINK
ACT
2/5
CONSO 10/
LE 100M
LINK
ACT
Managed Switch
(DVS-100 Series)
IIoT Routers
POWER S/S
RUN X0
ERROR X1
COM1 X2
IN X3
X4
RUN
X5
X6
STOP X7
INTERNET
C0
Y0
DVP-12SE
COM1 OUT Y1
Y2
Y3
ALARM
1
2 1 PWR1
SG RESET
3 2 PWR2
4
COM3+ 3 DI1
COM3- 4 DI2
DVS-108
W02-2SF
P
GE7
Ethernet
R 100/
1000M
10/100
/1000M
LINK
ACT 1/4
GE8 LINK
ACT
2/5
CONSOLE 10/
100M
3/6
LINK
ACT
X0
IP Camera
ERROR X1
COM1 X2
IN X3
X4
RUN
X5
X6
STOP X7
C0
Y0
DVP-12SE
COM1 OUT Y1
Y2
Y3
SG
COM3+
COM3-
ALARM
1
2 1 PWR1
RESET
3 2 PWR2
4
3 DI1
4 DI2
DVS-10
8W02-2
Ethernet SFP
R
1
2
O
N
GE7
100/ 10/100
1000M /1000M
PWR1
LINK PWR2
ACT ALARM
1/4
GE8 LINK
ACT
2/5
CONSO 10/
7
LE 100M
3/6
LINK
ACT POWER S/S 6
RUN X0
DVS-G408W01
ERROR X1
COM1 X2
IN X3
X4 5
RUN
X5
X6
STOP X7
C0
4
Y0
DVP-12SE
COM1 OUT Y1
Y2
Y3
3
SG
COM3+
COM3-
ALARM
1
2 1 PWR1
RESET 2
3 2 PWR2
PoE 10/100/1000M
4
3 DI1
4 DI2
DVS-108
W02-2SF
Ethernet P
R
1
GE7
100/ 10/100
1000M /1000M
LINK
ACT 1/4
GE8 LINK
ACT
PoE+ Switch
2/5
CONSOLE 10/
100M
3/6
LINK
ACT
(DVS-G400 Series)
POWER S/S
RUN X0
ERROR X1
COM1 X2
IN X3
X4
RUN
X5
X6
STOP X7
C0
Y0
DVP-12SE
COM1 OUT Y1
Managed Switch
Y2
Y3
SG
COM3+
COM3-
ALARM
1
2 1 PWR1
RESET
3 2 PWR2
4
(DVS-100 Series)
3 DI1
4 DI2
DVS-108
W02-2SF
P
Ethernet
R
GE7
100/ 10/100
1000M /1000M
LINK
ACT 1/4
GE8 LINK
ACT
2/5
CONSOLE 10/
100M
3/6
LINK
ACT
10
Industry
DVS-008 Series
IEEE 802.11 WLAN
PORT ALARM
1
2
3
DVS
RX
TX
2 3
7
100M
5
LINK
operating temperature
ACT
8
Unmanaged Switch
AH500 Series (DVS-008 Series)
DVP-SE Series
11
Industry
Ethernet
POWER S/S
RUN X0
ERROR X1
1 COM1 X2
Antenna
IN X3
2 X4
RUN
X5
DVW-W
TR1 OFF
02W2-E 3 X6
2
ON
STOP X7
COM1 TR2 OFF
PWR2 TXD- ON
C0
STATUS PWR1 TXD+ COM2
DCD
RXD+
(D+)
Y0
COM1 DI RXD TXD-
RS-422/485
DVP-12SE
RX RXD-
COM2
RX
COM1
TX
(D-) TXD TXD+
DCD
COM1 OUT Y1
GND RXD+
DTR (D+)
Y2
RS-422/485
RXD
RS-232
CLIENT COM2
MODE TX RXD-
AP/BRIDG GND (D-) TXD
ALARM MODE E DSR GND Y3
DTR
RS-232
RTS
GND
CTS
DSR
SG
RTS
CONSOLE
10/100/
COM3+
CTS
1000M COM3-
LAN1 10/100/
1000M
RESET
LAN2
LINK
/ ACT
LINK
/ ACT
Ethernet
R
Ethernet Switches
WiFi Client
DVPEN01
(DVW Series)
POWER S/S
RUN X0 1
Antenna
POWER
ERROR X1
RS-232
COM1 X2 2
100M
LINK IN X3
DVW-W
X4 TR1 OFF
02W2-E 3
2
RUN
X5 ON
STOP X7 COM2
ON
RX RXD-
C0 COM2 COM1
(D-) TXD TXD+
DCD
RX TX GND RXD+
DTR (D+)
Y0
RS-422/485
RXD
RS-232
CLIENT COM2
MODE TX RXD-
DVP-12SE
RTS
Y2 GND
CTS
DSR
Y3
RTS
CONSOLE
10/100/ CTS
1000M
SG
LAN1 10/100/
COM3+ 1000M
COM3-
RESET
LAN2
LINK
/ ACT
LINK
/ ACT
Ethernet
R
PLC WiFi AP
(DVP Series) (DVW Series) CNC Machine
IIoT Routers
DVPEN01 POWER S/S
RUN X0
POWER 1
Antenna
ERROR X1
RS-232 1
Antenna
COM1 X2
100M 2
LINK IN X3 2
X4 DVW-W
RUN 02W2-E 3
TR1 OFF 2
X5 DVW-W
02W2-E 3 ON
TR1 OFF
X6 2
COM1 TR2 OFF
ON
TR2 OFF
STATUS PWR1 TXD+ COM2
PWR2 TXD- ON DCD
RXD+
COM1 DI (D+)
C0 RXD TXD-
RS-422/485
TX GND RXD+
RX RXD- DTR (D+)
RS-422/485
DVP-12SE
(D-) RXD
RS-232
AP/BRIDG TXD
ALARM MODE RTS
E DSR GND GND
Y3 DTR
RS-232
CTS
RTS DSR
GND
CTS RTS
DSR CONSOLE
10/100/ CTS
SG CONSOLE
RTS 1000M
10/100/ CTS
COM3+ 1000M LAN1 10/100/
COM3- 1000M
LAN1 10/100/
1000M RESET
LAN2
RESET LINK
LAN2 / ACT
LINK
/ ACT
LINK
/ ACT
LINK
/ ACT
Ethernet
R
12
Industry
Ethernet Switches
Functions
Feature-rich Layer 2+/3 Network Management ....................................................................................................................................... 14
Managed Switches
DVS-328 Series: Managed Industrial 20-Port FE + 4-Port FE Combo 100Base-SFP + 4-Port GbE Combo 100/1000Base-SFP Rack
Mount Ethernet Switches ............................................................................................................................................. 22
DVS-G116 Series: Managed Industrial Ethernet Switches 12-Port GbE + 4-Port 100/1000Base-SFP .................................................... 24
DVS-G112 Series: Managed Industrial Ethernet Switches 8-Port GbE + 4-Port 100/1000Base-SFP ...................................................... 28
DVS-G106 Series: Managed Industrial Ethernet Switches 4-Port GbE + 2-Port 100/1000Base-SFP ...................................................... 31
DVS-110 Series: Managed Industrial 7-Port FE + 3-Port GbE Combo 100/1000Base-SFP Ethernet Switches ....................................... 34
DVS-109 Series: Managed Industrial 8-Port FE + 1-Port GbE Ethernet Switches ................................................................................... 37
IEEE 802.11 WLAN
DVS-108 Series: Managed Industrial 6-Port FE + 2-Port GbE Combo 100/1000Base-SFP Ethernet Switches ....................................... 40
DVS-103I02C-DLR Series: EtherNet/IP DLR Industrial 3-Port FE Ethernet Switches ............................................................................ 43
Unmanaged Switches
DVS-G008W01 Series: Unmanaged Industrial 8-Port GbE Ethernet Switches ....................................................................................... 45
DVS-G005I00A Series: Unmanaged Industrial 5-Port GbE Ethernet Switches ....................................................................................... 47
DVS-016 Series: Unmanaged Industrial 16-Port FE Ethernet Switches .................................................................................................. 49
DVS-008 Series: Unmanaged Industrial 8-Port FE Ethernet Switches .................................................................................................... 51
DVS-005 Series: Unmanaged Industrial 5-Port FE Ethernet Switches .................................................................................................... 53
DVS-G005I00C Series: Unmanaged Industrial 5-Port GbE Ethernet Switches ........................................................................................ 55
IIoT Routers
DVS-008W00-M12 Series: Unmanaged Industrial 8-Port FE M12 IP67 Ethernet Switches ..................................................................... 57
13
Industry
Feature-rich Layer 2+/3 Network Management
Ethernet Switches
LAN A LAN B
Ethernet
Ethernet
IIoT Routers
Network Redundancy Technology
IEEE published the 802.1D Spanning Tree Protocol (STP) in 1998, and in 2004 announced 802.1w Rapid Spanning Tree Protocol (RSTP),
which is an enhancement to STP. These network protocols are used to construct backup paths for transmission when a link fails and are
applied in network structures with requirements for high reliability. In current industrial automation and critical system applications, as the high
demand for faster convergence time grows, STP and SRTP’s speed, whose unit of convergence time is in seconds, becomes insufficient.
Delta thoroughly understands customers’ needs from different industries. To meet the high demand for speed and reliability, Delta has
introduced ONE RING and ONE CHAIN ultra-speed redundant protocols to satisfy our customers’ needs, by providing faster speed and more
functions than STP and RSTP. With IIoT and Industry 4.0 becoming megatrend, Delta network redundancy technology continues to evolve
and optimize all the time. ONE RING Plus and ONE CHAIN Plus provide a far higher level of performance than the previous generation
ONE RING and ONE CHAIN. ONE RING Plus and ONE CHAIN Plus reduce double recovery time and bring excellent reliable and stable
redundancy network.
Plus Plus
14
Industry
Plus
Dual-Homing
IIoT Routers
Plus
15
Industry
Advanced Network Management
▲VLAN
ALARM ALARM
1 1
2 1 PWR1 2 1 PWR1
RESET RESET
3 2 PWR2 3 2 PWR2
4 4
3 DI1 3 DI1
4 DI2 4 DI2
DVS-110W DVS-110W
GE8 GE8
02-3SFP 02-3SFP
100/ 10/100 100/ 10/100
1000M /1000M 1000M /1000M
LINK LINK
ACT ACT
LINK 1 LINK 1
GE9 GE9
ACT ACT
2/5 2/5
GE10 GE10
4/7 4/7
LINK LINK
ACT ACT
to a logical scheme rather than a physical layout. VLANs allow users to break
up switched environments into multiple broadcast domains, and can be used to
combine any collection of LAN segments into an autonomous user group that
POWER S/S
POWER S/S
RUN X0
RUN X0
ERROR X1
ERROR X1
COM1 X2
COM1 X2
IN X3
IN X3
X4
X4 RUN
RUN X5
X5
X6
C0
C0
Y0
Y0
DVP-12SE
OUT Y1
DVP-12SE
COM1
COM1 OUT Y1
Y2
Y2
Y3
Y3
Ethernet Switches
SG
SG
COM3+
COM3+ COM3-
COM3-
▲Trunking
PS05-A1
POWER 16AM10N
16AM10N
16AM10N
16AM10N
I/O0 16AM10N
I/O1
PULL I/O2
I/O3
I/O4
The physical ports of a switch can be aggregated by a logical scheme into a PS05-A1
POWER
16AM10N
16AM10N
1
3
ALARM
2
4
1 PWR1
2 PWR2
3 DI1
RESET
1
3
ALARM
2
4
1 PWR1
2 PWR2
3 DI1
RESET
group which forms a physical link. This link serves as a redundant path which
4 DI2 4 DI2
16AM10N DVS-110W0 DVS-110W0
GE8 GE8
2-3SFP 2-3SFP
16AM10N 100/ 10/100 100/ 10/100
1000M /1000M 1000M /1000M
16AM10N LINK LINK
I/O0 ACT ACT
I/O1
LINK 1 LINK 1
PULL I/O2 GE9
ACT
GE9
ACT
I/O3
I/O4 2/5 2/5
GE10 GE10
3/6 3/6
4/7 4/7
LINK LINK
ACT ACT
Enhanced bandwidth
PS05-A1
POWER
16AM10N
16AM10N
16AM10N
16AM10N
I/O0 16AM10N
I/O1
PULL I/O2
I/O3
I/O4
Top Priority
packets with a queue. It ensures prompt packet scheduling that is especially High Priority
ALARM
1
2 1 PWR1
RESET
3 2 PWR2
4
3 DI1
LINK
ACT
LINK 1
GE9
ACT
2/5
GE10
3/6
4/7
LINK
ACT
RTU
SW C
3 2 PWR2
3 2 PWR2
SW A
4
4 3 DI1
3 DI1
4 DI2
4 DI2
DVS-110W02
DVS-110W02 GE8
GE8
-3SFP
-3SFP 100/ 10/100
100/ 10/100 1000M
1000M /1000M
/1000M
LINK
LINK ACT
ACT
1 LINK 1
LINK GE9
GE9 ACT
ACT
2/5
2/5
GE10
GE10
3/6
3/6
CONSOLE 10/
CONSOLE 10/ 100M
100M
4/7
4/7
LINK
LINK ACT
ACT
The LLDP protocol is used by network devices for advertising their identity, 1
3
ALARM
2
4
1 PWR1
2 PWR2
3 DI1
4 DI2
GE8
RESET
DVS-110W02
I know I have neighbors
SW A, B, C, D
-3SFP
100/ 10/100
1000M /1000M
LINK
ACT
2/5
GE10
3/6
IIoT Routers
CONSOLE 10/
100M
4/7
LINK
ACT
These messages are stored in SNMP MIB and can be searched through a 1
3
ALARM
2
4
1 PWR1
2 PWR2
3 DI1
4 DI2
RESET
1
3
ALARM
2
4
1 PWR1
2 PWR2
3 DI1
4 DI2
RESET
SW B
DVS-110W02
SW D
DVS-110W02 GE8
GE8
-3SFP
-3SFP 100/ 10/100
100/ 10/100 1000M
1000M /1000M
/1000M
LINK
LINK ACT
ACT
2/5
2/5
GE10
GE10
3/6
3/6
CONSOLE 10/
CONSOLE 10/ 100M
100M
4/7
4/7
LINK
LINK ACT
ACT
16
Industry
real-time notification, on-site personnel can quickly diagnose and eliminate any
incidents.
Alarm Indicators
▲Digital Inputs
Designed for industrial environments, the DVS series industrial Ethernet switches
easily connect to various industrial devices, such as PLCs or sensors. It delivers
real-time alarms to users via relay output or email.
DC OK
Adjust
DC OK
The design of dual power inputs provides excellent integration with the common
dual power supply design of critical systems, or with industrial environments. It
secures switches from potential power impact and provides highly-reliable and
uninterrupted network transmission.
17
Industry
A Seamless Interconnection
DVS NB
Ethernet Switches
▲Real-time Web Display
A real-time Web display tells users the connection status of each port with
indicators on a Web page. With an uninterrupted network connection, users can
manage operations in remote places at any time.
▲SFP DDM
Utilizing the built-in digital diagnostic monitor (DDM) function of the DVS series
Industrial Ethernet Switches, users can continuously monitor the current operation
status of the Delta SFP fiber transceiver and the transmission quality through a
datasheet displayed on the web.
LINK
ACT
LINK 1
GE9
The hardware Watch Dog Timer restores switches from malfunctions caused by
ACT
2/5
GE10
any reasons, such as an incorrect network topology or a malicious network attack. CON
SOLE
3/6
10/
100M
NG
LINK
ACT
IIoT Routers
IEXplorer provides friendly access to search for all IES products on the network.
One simple click calls up the Web page for setting software functions.
18
Industry
DVS-G928 series
Layer 3 Managed Industrial 28-Port GbE Modular Rack Mount
Ethernet Switchs
Ethernet Switches
4 85
4
► IPv6 address suitable for larger network and ► Advanced DoS/DDoS auto prevention
neighbor discovery ► Enhanced network security with IEEE 802.1X,
► Layer 3 routing function allows multiple subnets in TACACS+, SSH, HTTPS and SNMP v3
a large network to exchange data and information ► IEEE 802.3ad port trunking in parallel to increase the
across a network address link bandwidth
► Automatic IP assignment by DHCP server for easy ► IEEE 1588v2 PTP (Precision Time Protocol) for precise
network construction time synchronization of network
► DHCP relay option 82 for sending DHCP requests ► Broadcast/Multicast/ Unknown Unicast storm control
IEEE 802.11 WLAN
CHAIN high-end redundancy technology adopts ► RMON groups 1,2,3,9(history, statistics, alarms and
easy-to-build multiple ring topology, with self- events) for enhanced flow management and analysis
healing recovery time <30 ms to ensure reliable ► Port mirroring for Many-to-One ports online
network transmission troubleshooting
► STP/RSTP/MSTP for network redundancy ensures ► Versatile system file updates by TFTP, HTTPS or HTTP
reliability ► DDM diagnosis function by SFP fiber modules
► QoS(IEEE 802.1p) and TOS/DSCP for mission- ► Auto warning by email, relay, Syslog & SNMP trap
critical applications ► Compatible with various industrial protocols, including
► IEEE 802.1Q VLAN and GVRP optimize network EtherNet/IP, Profinet, CC-LINK IE and DNP 3.0
strategy
Specifications
TECHNOLOGY
Standard Compliance • IEEE 802.1w Rapid Spanning Tree Protocol Processing Type
• IEEE 802.3 10Base-T • IEEE 802.1s Multiple Spanning Tree Protocol • Store and Forward
• IEEE 802.3u 100Base-T(X) and 100Base-FX • IEEE 802.1p Class of Service, Priority Protocols • IEEE 802.3x Flow control in
• IEEE 802.3ab 1000Base-T • IEEE 802.1Q VLAN Tagging full duplex, back-pressure flow
• IEEE 802.3z 1000Base-X • IEEE 802.1AD VLAN Q-in-Q control in half duplex
• IEEE 802.3ae 10 Gigabit • IEEE 802.1X Port Authentication
• IEEE 802.3x Flow Control • IEEE 802.3ad LACP Aggregation
• IEEE 802.1D Spanning Tree Protocol • IEEE 802.1AB Link Layer Discovery Protocol
19
Industry
INTERFACE
Gigabit Ethernet Module Number Alarm Contacts (DO)
RJ45 Ports Module slots 1, 2 and 3: • 1 relay output (Normal open)
• auto MDI/MDI-X, auto negotiation • 8-Port 10/100/1000Base-T • 1 relay output (Normal close)
SFP Ports 8-Port 100/1000Base-SFP • Carry current 1A @ 24VDC
• 100/1000Base-SFP 6-Port 10/100/1000Base-T M12 modules Reset Button
M12 Ports Module slot 4 : • 1 set
• A-coded 8-pin female connector; auto MDI/ • 4-Port 1000Base-SFP module
MDI-X, auto negotiation LEDs
Console Port Device:
Ethernet Switches
• RS-232(RJ45 connector) • STATUS, PWR1, PWR2, R.M, RING,
ALARM, RESET
Ports:
• 10/100/1000M (RJ45 port), LINK/ACT
MANAGEMENT
Layer 3 Routing Configuration
• RIP, VRRP v2/v3 • Web browser, Cisco-like Telnet CLI , RJ45 console,
Software SNMP
• STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/v2/v3, IGMP Query
MIB
v1/v2, GVRP, VLAN, VLAN Q-in-Q, VLAN unaware, SSH, DNS, HTTP,
• MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/
HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP Traps, TFTP,
P-Bridge MIB, IF MIB, Traceroute MIB, TCP MIB, UDP
RMON, LLDP, DHCP Server/Client, DHCP Relay Option 82, Telnet,
MIB, IP MIB, RMON Group 1,2,3,9, Delta Private MIB
Syslog, SMTP, SNTP Server/Client, IPv6, MODBUS TCP, EtherNet/IP
Security
IIoT Routers
• MAC/IP/TCP/UDP filtering, HTTPS, SSH, 802.1x, TACACS+, SNMP v3
POWER REQUIREMENTS
Input Voltage Input Current Reverse Polarity Protection
• Installation: Rear cabling, industrial terminal block, • Max. 1.3A • Present (VDC input )
redundant design Overload Current Protection
• 2 sets 100 to 240VAC / 125 to 370VDC (Tested @ 100 • Present, Max. input current 6.3A
to 240VAC)
PHYSICAL
Housing Weight
• IP30 metal case • 6,600g
Dimensions Installation
• 44 mm(H) x 440 mm(W) x 325 mm (D) • 19" Rack mounting
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -40℃ to 85℃ (-40 ℉ to 185 ℉ ) • -40℃ to 85℃ (-40 ℉ to 185 ℉ ) • 5% to 95% (non-condensing)
20
Industry
APPROVALS
Safety Environmental Type Tests
• UL 61010, IEC 60950-1, CCC (DVS-G928W01-CN) Shock:
EMI • IEC 60068-2-27
• FCC 47 CFR Part 15 Subpart B Class A, Freefall:
EN 55022 (CISPR 22), EN 55032 • IEC 60068-2-32
EMS (EN 55024) Vibration:
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, • IEC 60068-2-6
IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, Hi-Pot:
• 1.5KV
Ethernet Switches
Ordering Information
Product Port Combination Interface
IEEE 802.11 WLAN
Operating Module Slot Module Slot Module Slot Module Slot DO Power
Model Name DI
Temperature M1 M2 M3 M4 (Relay) Input
DVS-G928W01 -40℃ to 85℃ Select interface modules and SFP fiber transceivers - 2 2
DVS-G928W01-CN -40℃ to 85℃ Select interface modules and SFP fiber transceivers - 2 2
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver. See the LCP Series datasheets for product information.
21
Industry
DVS-328 series
Managed Industrial 20-Port FE + 4-Port FE combo 100Base-SFP
+ 4-Port GbE combo 100/1000Base-SFP Rack Mount Ethernet
Switchs
Ethernet Switches
4 70
4
► IPv6 address suitable for larger network and ► IEEE 802.3ad port trunking in parallel to increase the
neighbor discovery link bandwidth
► Automatic IP assignment by DHCP/BootP server for ► SNTP (simple network time protocol) for network clock
easy network construction synchronization
► DHCP relay option 82 for sending DHCP requests ► Broadcast/Multicast / Unknown Unicast storm control
with clients’ identities to a DHCP server improves throughput problems
► Port-based DHCP server with IP and MAC binding ► Loopback-Detection to avoid broadcast loops, and
IIoT Routers
► STP/RSTP/MSTP for network redundancy further ► CPU utilization displays the amount of works the CPU
ensures reliability handles
► QoS(IEEE 802.1p) and TOS/DSCP for mission-critical ► Port mirroring for Many-to-One ports online
applications troubleshooting
► IEEE 802.1Q VLAN, MAC-based VLAN, IP Subnet- ► Versatile system file updates by TFTP, HTTPS or HTTP
based VLAN, VLAN isolation and GVRP optimize ► DDM diagnosis function by SFP fiber module
network strategy ► Auto warning by email, DI, relay, Syslog & SNMP trap
► Enhanced network security with IEEE 802.1X, ► Compatible with various industrial protocols, including
TACACS+, SSH, HTTPS and SNMP v3 EtherNet/IP, Profinet, CC-LINK IE and DNP 3.0
Specifications
TECHNOLOGY
Standard Compliance • IEEE 802.1s Multiple Spanning Tree Protocol Processing Type
• IEEE 802.3 10Base-T • IEEE 802.1p Class of Service, Priority Protocols • Store and Forward
• IEEE 802.3u 100Base-T(X) and 100Base-FX • IEEE 802.1Q VLAN Tagging • IEEE 802.3x Flow control in
• IEEE 802.3ab 1000Base-T • IEEE 802.1AD VLAN Q-in-Q full duplex, back-pressure flow
• IEEE 802.3z 1000Base-X • IEEE 802.1X Port Authentication control in half duplex
• IEEE 802.3x Flow Control • IEEE 802.3ad LACP Aggregation
• IEEE 802.1D Spanning Tree Protocol • IEEE 802.1AB Link Layer Discovery Protocol
• IEEE 802.1w Rapid Spanning Tree Protocol
22
Industry
INTERFACE
Fast Ethernet Console Port Digital Inputs(DI)
RJ45 Ports • RS-232 (USB B-Type connector) • 1 set
• 20 10/100Base-T(X), auto MDI/MDI-X, auto LEDs • 0~+5V is OFF
negotiation Device:
Fast Ethernet Combo Ports • PWR1, PWR2, PWR3, R.M/CPLG.R, C.HD/C.TL, • +11V~30V is ON
RJ45 Ports: ALARM, DI • Input current 6mA Max
• 4 10/100Base-T(X), auto MDI/MDI-X, auto Ports:
negotiation • 100M(SFP port), 100/1000M(SFP port), Alarm Contacts(DO)
SFP Ports: 10/100M(RJ45 port), 10/100/1000M(RJ45 port), • 1 relay output
Ethernet Switches
MANAGEMENT
Software Configuration
• STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/v2/v3, IGMP Query • Web Browser, Cisco-like Telnet CLI, USB Local Console ,
v1/v2, GARP, GMRP, VLAN, VLAN Q-in-Q, VLAN unaware, SSH, SNMP, MODBUS TCP, IEXplorer Utility
DNS, HTTP, HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP
Traps, TFTP, RMON, LLDP, BootP Server/Client, DHCP Server/Client,
MIB
DHCP L2 Relay, DHCP Relay Option 82, DHCP Option 66/67, RARP, • MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/
Telnet, Syslog, SMTP, SNTP Server/Client, IPv6, DoS/DDoS auto P-Bridge MIB, IF MIB, Traceroute MIB, TCP MIB, UDP
IIoT Routers
prevention, MODBUS TCP, EtherNet/IP MIB, IP MIB, RMON Group 1,2,3,9, Delta Private MIB
Security
• MAC filtering, HTTPS, SSH, 802.1x, TACACS+, SNMP v3
POWER REQUIREMENTS
Input Voltage Input Current Reverse Polarity Protection
• Installation: Front cabling. Industrial terminal block • LV: 0.75A • Present (VDC input )
• LV: 2 sets 36 to 72VDC (Tested @ 36 to 60VDC) • HV: 1.2A Voltage Dips Protection Time
• HV: 1 set 85 to 264VAC / 88 to 370VDC (Tested @ 100 Overload Current Protection • Min. 12ms at 48 VDC
to 240VAC) • Present, Max. Input current 8A
PHYSICAL
Housing Weight
• IP40 metal case • 4,950g
Dimensions Installation
• 44 mm(H) x 440 mm(W) x 257 mm (D) • 19" Rack mounting and wall mounting
23
Industry
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -40℃ to 70℃ (-40 ℉ to 158 ℉ ) • -40℃ to 85℃ (-40 ℉ to 185 ℉ ) • 5% to 95% (non-condensing)
APPROVALS
Safety Environmental Type Tests
Ethernet Switches
• UL 60950-1, IEC 60950-1, CCC Cold Temperature: Freefall:
EMI • IEC 60068-2-1 • IEC 60068-2-32
Dry Heat: Vibration:
• FCC 47 CFR Part 15 Subpart B Class A, IEC
61000-6-4, EN 55022 (CISPR 22), EN 55032 • IEC 60068-2-2 • IEC 60068-2-6
Humidity: Hi-Pot:
EMS [IEC 61000-6-2, EN 55024]
• IEC 60068-2-30 • 1.5KV
• IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4,
IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, Shock:
IEC 61000-4-11, IEC 61000-4-29 • IEC 60255-21-2
Ordering Information
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver. See the LCP Series datasheets for product information.
CliQII/PMC Series: 48 VDC Industrial Power Supply
IIoT Routers
24
Industry
DVS-G116 series
Managed Industrial 12-Port GbE + 4-Port 100/1000Base-SFP
Ethernet Switchs
Ethernet Switches
6 0 0
4
► IPv6 address suitable for larger network and ► Port-isolated for special security environment
neighbor discovery
► IEEE 802.3ad port trunking in parallel to increase the
► Automatic IP assignment by DHCP/BootP server for link bandwidth
easy network construction
► SNTP (simple network time protocol) for network clock
► DHCP relay option 82 for sending DHCP requests synchronization
with clients’ identities to a DHCP server
► Broadcast/Multicast / Unknown Unicast storm control
► Port-based DHCP server with IP and MAC binding improves throughput problems
makes IP maintenance much easier
► Loopback-Detection to avoid broadcast loops, and
IEEE 802.11 WLAN
► Q-in-Q double VLAN to distinguish multiple VLANs shutdown the corresponding ports automatically
► SNMP v1/v2c/v3 facilitates the exchange of ► Intelligent Access Control List (ACL)
management between network devices
► MAC addresses locking function per port blocks
► Supports EtherNet/IP and MODBUS TCP protocols unauthorized access
that facilitates the remote management by SCADA
► IGMP Snooping and GMVP prunes multicast traffic
and other industrial devices
► RMON groups 1,2,3,9(history, statistics, alarms and
► Proprietary ONE RING Plus and ONE CHAIN Plus
events) for enhanced flow management and analysis
high end redundancy technology, easy to build
multiple ring topology, self-healing recovery time < ► CPU utilization displays the amount of works the CPU
10ms handles
► STP/RSTP/MSTP for network redundancy further ► Port mirroring for Many-to-One ports online
IIoT Routers
Specifications
TECHNOLOGY
Standard Compliance • IEEE 802.1s Multiple Spanning Tree Protocol Processing Type
• IEEE 802.3 10Base-T • IEEE 802.1p Class of Service, Priority Protocols • Store and Forward
• IEEE 802.3u 100Base-T(X) and 100Base-FX • IEEE 802.1Q VLAN Tagging • IEEE 802.3x Flow control in
• IEEE 802.3ab 1000Base-T • IEEE 802.1AD VLAN Q-in-Q full duplex, back-pressure flow
• IEEE 802.3z 1000Base-X • IEEE 802.1X Port Authentication control in half duplex
• IEEE 802.3x Flow Control • IEEE 802.3ad LACP Aggregation
• IEEE 802.1D Spanning Tree Protocol • IEEE 802.1AB Link Layer Discovery Protocol
• IEEE 802.1w Rapid Spanning Tree Protocol
25
Industry
INTERFACE
Gigabit Ethernet Console Port Digital Inputs(DI)
RJ45 Ports: • RS-232 (Micro-USB connector) • 1 set
• 12 10/100/1000Base-T, auto MDI/MDI-X, LEDs • 0~+5V is OFF
auto negotiation Device:
SFP Ports: • PWR1, PWR2, R.M/CPLG.R, C.HD/C.TL, • +11V~30V is ON
• 4 100/1000Base-SFP ALARM, DI • Input current 6mA Max
Ports:
• 100/1000M(SFP port), Alarm Contacts(DO)
10/100/1000M(RJ45 port), LINK/ACT • 1 relay output
Ethernet Switches
• Carry current 1A @ 24VDC
Reset Button
• 1 set
MANAGEMENT
Software Configuration
• STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/v2/v3, IGMP Query • Web Browser, Cisco-like Telnet CLI, USB Local Console ,
v1/v2, GARP, GMRP, VLAN, VLAN Q-in-Q, VLAN unaware, SSH, SNMP, MODBUS TCP, IEXplorer Utility
DNS, HTTP, HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP
Traps, TFTP, RMON, LLDP, BootP Server/Client, DHCP Server/Client,
MIB
DHCP L2 Relay, DHCP Relay Option 82, DHCP Option 66/67, RARP, • MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/
Telnet, Syslog, SMTP, SNTP Server/Client, IPv6, MODBUS TCP, P-Bridge MIB, IF MIB, Traceroute MIB, TCP MIB, UDP
IIoT Routers
EtherNet/IP MIB, IP MIB, RMON Group 1,2,3,9, Delta Private MIB
Security
• Port Security, HTTPS, SSH, 802.1x, TACACS+, SNMP v3
POWER REQUIREMENTS
Input Voltage Input Current Reverse Polarity Protection
• 2 sets, 12 to 48VDC redundant terminal • Max. 0.58A • Present
block input Overload Current Protection Voltage Dips Protection Time
• Present, Max. Input current 12A • Min. 10ms at 48 VDC
PHYSICAL
Housing Weight
• IP40 metal case • 1,100g
Dimensions Installation
• 135 mm(H) x 65 mm(W) x 135 mm (D) • Industial DIN-Rail and wall mounting
26
Industry
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -40℃ to 75℃ (-40 ℉ to 167 ℉ ) • -40℃ to 85℃ (-40 ℉ to 185 ℉ ) • 5% to 95% (non-condensing)
APPROVALS
Safety Environmental Type Tests
Ethernet Switches
Ordering Information
IEEE 802.11 WLAN
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver. See the LCP Series datasheets for product information.
CliQII/PMC Series: 48 VDC Industrial Power Supply
IIoT Routers
27
Industry
DVS-G112 series
Managed Industrial 8-Port GbE + 4-Port 100/1000Base-SFP
Ethernet Switchs
Ethernet Switches
6 0 0
4
► IPv6 address suitable for larger network and ► Port-isolated for special security environment
neighbor discovery
► IEEE 802.3ad port trunking in parallel to increase the
► Automatic IP assignment by DHCP/BootP server for link bandwidth
easy network construction
► SNTP (simple network time protocol) for network clock
► DHCP relay option 82 for sending DHCP requests synchronization
with clients’ identities to a DHCP server
► Broadcast/Multicast / Unknown Unicast storm control
► Port-based DHCP server with IP and MAC binding improves throughput problems
makes IP maintenance much easier
► Loopback-Detection to avoid broadcast loops, and
IIoT Routers
ensures reliability troubleshooting
► QoS(IEEE 802.1p) and TOS/DSCP for mission-critical ► Versatile system file updates by TFTP, HTTPS or HTTP
applications
► DDM diagnosis function by SFP fiber module
► IEEE 802.1Q VLAN, MAC-based VLAN, IP Subnet-
► Auto warning by email, DI, relay, Syslog & SNMP trap
based VLAN, VLAN isolation and GVRP optimize
network strategy ► Compatible with various industrial protocols, including
EtherNet/IP, Profinet, CC-LINK IE and DNP 3.0
► Enhanced network security with IEEE 802.1X,
TACACS+, SSH, HTTPS and SNMP v3
Specifications
TECHNOLOGY
Standard Compliance • IEEE 802.1s Multiple Spanning Tree Protocol Processing Type
• IEEE 802.3 10Base-T • IEEE 802.1p Class of Service, Priority Protocols • Store and Forward
• IEEE 802.3u 100Base-T(X) and 100Base-FX • IEEE 802.1Q VLAN Tagging • IEEE 802.3x Flow control in
• IEEE 802.3ab 1000Base-T • IEEE 802.1AD VLAN Q-in-Q full duplex, back-pressure flow
• IEEE 802.3z 1000Base-X • IEEE 802.1X Port Authentication control in half duplex
• IEEE 802.3x Flow Control • IEEE 802.3ad LACP Aggregation
• IEEE 802.1D Spanning Tree Protocol • IEEE 802.1AB Link Layer Discovery Protocol
• IEEE 802.1w Rapid Spanning Tree Protocol
28
Industry
INTERFACE
Gigabit Ethernet Console Port Digital Inputs(DI)
RJ45 Ports: • RS-232 (Micro-USB connector) • 1 set
• 8 10/100/1000Base-T, auto MDI/MDI-X, auto LEDs • 0~+5V is OFF
negotiation Device:
SFP Ports: • PWR1, PWR2, R.M/CPLG.R, C.HD/C.TL, • +11V~30V is ON
• 4 100/1000Base-SFP ALARM, DI • Input current 6mA Max
Ports:
• 100/1000M(SFP port), Alarm Contacts(DO)
10/100/1000M(RJ45 port), LINK/ACT • 1 relay output
Ethernet Switches
Forwarding Rate
• 35.71Mpps Max. VLANs Jumbo Frame
MAC Address Table • 255 • 9,600 Bytes
• 8K
MANAGEMENT
Software Configuration
• STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/v2/v3, IGMP Query • Web Browser, Cisco-like Telnet CLI, USB Local Console ,
v1/v2, GARP, GMRP, VLAN, VLAN Q-in-Q, VLAN unaware, SSH, SNMP, MODBUS TCP, IEXplorer Utility
DNS, HTTP, HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP
Traps, TFTP, RMON, LLDP, BootP Server/Client, DHCP Server/Client,
MIB
DHCP L2 Relay, DHCP Relay Option 82, DHCP Option 66/67, RARP, • MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/
Telnet, Syslog, SMTP, SNTP Server/Client, IPv6, MODBUS TCP, P-Bridge MIB, IF MIB, Traceroute MIB, TCP MIB, UDP
IIoT Routers
Security
• Port Security, HTTPS, SSH, 802.1x, TACACS+, SNMP v3
POWER REQUIREMENTS
Input Voltage Input Current Reverse Polarity Protection
• 2 sets, 12 to 48VDC redundant terminal • Max. 0.58A • Present
block input Overload Current Protection Voltage Dips Protection Time
• Present, Max. Input current 12A • Min. 10ms at 48 VDC
PHYSICAL
Housing Weight
• IP40 metal case • 1,080g
Dimensions Installation
• 135 mm(H) x 51 mm(W) x 135 mm (D) • Industial DIN-Rail and wall mounting
29
Industry
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -40℃ to 75℃ (-40 ℉ to 167 ℉ ) • -40℃ to 85℃ (-40 ℉ to 185 ℉ ) • 5% to 95% (non-condensing)
APPROVALS
Safety Environmental Type Tests
Ethernet Switches
• UL 61010, IEC 62368-1 Cold Temperature: Freefall:
EMI • IEC 60068-2-1 • ISTA-2A
Dry Heat: Vibration:
• FCC 47 CFR Part 15 Subpart B Class A, IEC
61000-6-4, EN 55032 (CISPR 32) • IEC 60068-2-2 • IEC 60068-2-6
Humidity: Hi-Pot:
EMS [IEC 61000-6-2, EN 55024]
• IEC 60068-2-30 • 1.5KV
• IEC 61000-4-2 level 4, IEC 61000-4-3 level 3,
IEC 61000-4-4 level 4, IEC 61000-4-5 level 4, Shock:
IEC 61000-4-6 level 3, IEC 61000-4-8 level 4, • IEC 60068-2-27
IEC 61000-4-29
Ordering Information
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver. See the LCP Series datasheets for product information.
IIoT Routers
CliQII/PMC Series: 48 VDC Industrial Power Supply
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
30
Industry
DVS-G106 series
Managed Industrial 4-Port GbE + 2-Port 100/1000Base-SFP
Ethernet Switchs
Ethernet Switches
6 0 0
4
► IPv6 address suitable for larger network and ► Port-isolated for special security environment
neighbor discovery
► IEEE 802.3ad port trunking in parallel to increase the
► Automatic IP assignment by DHCP/BootP server for link bandwidth
easy network construction
► SNTP (simple network time protocol) for network clock
► DHCP relay option 82 for sending DHCP requests synchronization
with clients’ identities to a DHCP server
► Broadcast/Multicast / Unknown Unicast storm control
► Port-based DHCP server with IP and MAC binding improves throughput problems
makes IP maintenance much easier
► Loopback-Detection to avoid broadcast loops, and
IEEE 802.11 WLAN
► Q-in-Q double VLAN to distinguish multiple VLANs shutdown the corresponding ports automatically
► SNMP v1/v2c/v3 facilitates the exchange of ► Intelligent Access Control List (ACL)
management between network devices
► MAC addresses locking function per port blocks
► Supports EtherNet/IP and MODBUS TCP protocols unauthorized access
that facilitates the remote management by SCADA
► IGMP Snooping and GMVP prunes multicast traffic
and other industrial devices
► RMON groups 1,2,3,9(history, statistics, alarms and
► Proprietary ONE RING Plus and ONE CHAIN Plus
events) for enhanced flow management and analysis
high end redundancy technology, easy to build
multiple ring topology, self-healing recovery time < ► CPU utilization displays the amount of works the CPU
10ms handles
► STP/RSTP/MSTP for network redundancy further ► Port mirroring for Many-to-One ports online
IIoT Routers
Specifications
TECHNOLOGY
Standard Compliance • IEEE 802.1s Multiple Spanning Tree Protocol Processing Type
• IEEE 802.3 10Base-T • IEEE 802.1p Class of Service, Priority Protocols • Store and Forward
• IEEE 802.3u 100Base-T(X) and 100Base-FX • IEEE 802.1Q VLAN Tagging • IEEE 802.3x Flow control in
• IEEE 802.3ab 1000Base-T • IEEE 802.1AD VLAN Q-in-Q full duplex, back-pressure flow
• IEEE 802.3z 1000Base-X • IEEE 802.1X Port Authentication control in half duplex
• IEEE 802.3x Flow Control • IEEE 802.3ad LACP Aggregation
• IEEE 802.1D Spanning Tree Protocol • IEEE 802.1AB Link Layer Discovery Protocol
• IEEE 802.1w Rapid Spanning Tree Protocol
31
Industry
INTERFACE
Gigabit Ethernet Console Port Digital Inputs(DI)
RJ45 Ports: • RS-232 (Micro-USB connector) • 1 set
• 4 10/100/1000Base-T, auto MDI/MDI-X, auto LEDs • 0~+5V is OFF
negotiation Device:
SFP Ports: • PWR1, PWR2, R.M/CPLG.R, C.HD/C.TL, • +11V~30V is ON
• 2 100/1000Base-SFP ALARM, DI • Input current 6mA Max
Ports:
• 100/1000M(SFP port), Alarm Contacts(DO)
10/100/1000M(RJ45 port), LINK/ACT • 1 relay output
Ethernet Switches
• Carry current 1A @ 24VDC
Reset Button
• 1 set
MANAGEMENT
Software Configuration
• STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/v2/v3, IGMP Query • Web Browser, Cisco-like Telnet CLI, USB Local Console ,
v1/v2, GARP, GMRP, VLAN, VLAN Q-in-Q, VLAN unaware, SSH, SNMP, MODBUS TCP, IEXplorer Utility
DNS, HTTP, HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP
Traps, TFTP, RMON, LLDP, BootP Server/Client, DHCP Server/Client,
MIB
DHCP L2 Relay, DHCP Relay Option 82, DHCP Option 66/67, RARP, • MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/
Telnet, Syslog, SMTP, SNTP Server/Client, IPv6, MODBUS TCP, P-Bridge MIB, IF MIB, Traceroute MIB, TCP MIB, UDP
IIoT Routers
EtherNet/IP MIB, IP MIB, RMON Group 1,2,3,9, Delta Private MIB
Security
• Port Security, HTTPS, SSH, 802.1x, TACACS+, SNMP v3
POWER REQUIREMENTS
Input Voltage Input Current Reverse Polarity Protection
• 2 sets, 12 to 48VDC redundant terminal • Max. 0.58A • Present
block input Overload Current Protection Voltage Dips Protection Time
• Present, Max. Input current 12A • Min. 10ms at 48 VDC
PHYSICAL
Housing Weight
• IP40 metal case • 1,020g
Dimensions Installation
• 135 mm(H) x 51 mm(W) x 135 mm (D) • Industial DIN-Rail and wall mounting
32
Industry
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -40℃ to 75℃ (-40 ℉ to 167 ℉ ) • -40℃ to 85℃ (-40 ℉ to 185 ℉ ) • 5% to 95% (non-condensing)
APPROVALS
Safety Environmental Type Tests
Ethernet Switches
Ordering Information
IEEE 802.11 WLAN
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver. See the LCP Series datasheets for product information.
CliQII/PMC Series: 48 VDC Industrial Power Supply
IIoT Routers
33
Industry
DVS-110 series
Managed Industrial 7-Por t FE + 3-Por t GbE
Combo 100/1000Base-SFP Ethernet Switches
Ethernet Switches
► IPv6 address suitable for larger network and ► Broadcast/Multicast/Unknown Unicast storm
neighbor discovery control improves throughput problems
► Automatic IP assignment by DHCP/BootP server ► Loopback-Detection to avoid broadcast loops, and
for easy network construction shutdown the corresponding ports automatically
► DHCP relay option 82 for sending DHCP requests ► Cable diagnostic provides the mechanism to detect
with clients’ identities to a DHCP server and report potential cabling issues
► Port-based DHCP server with IP and MAC binding ► Intelligent Access Control List (ACL)
makes IP maintenance much easier* ► MAC addresses locking function per port blocks
► SNMP v1/v2c/v3 facilitates the exchange of unauthorized access
management between network devices ► USB console interface for easy connection with
IIoT Routers
► IEEE 802.1Q VLAN, MAC-based VLAN, IP Subnet- HTTP
based VLAN, VLAN isolation and GVRP optimize ► DDM diagnosis function by SFP fiber module
network strategy ► Auto warning by email, DI, relay, Syslog & SNMP
► Enhanced network security with IEEE 802.1X, trap
TACACS+, SSH, HTTPS and SNMP v3 ► Compatible with various industrial protocols,
► IEEE 802.3ad port trunking in parallel to increase including EtherNet/IP, Profinet, CC-LINK IE and
the link bandwidth DNP 3.0
► SNTP (simple network time protocol) for network
clock synchronization
Specifications
TECHNOLOGY
Standard Compliance • IEEE 802.1w Rapid Spanning Tree Protocol Processing Type
• IEEE 802.3 10Base-T • IEEE 802.1s Multiple Spanning Tree Protocol • Store and Forward
• IEEE 802.3u 100Base-T(X) and 100Base-FX • IEEE 802.1p Class of Service, Priority Protocols • IEEE 802.3x flow control in
• IEEE 802.3ab 1000Base-T • IEEE 802.1Q VLAN Tagging full duplex, back-pressure flow
• IEEE 802.3z 1000Base-X • IEEE 802.1X Port Authentication control in half duplex
• IEEE 802.3x Flow Control • IEEE 802.3ad LACP Aggregation
• IEEE 802.1D Spanning Tree Protocol • IEEE 802.1AB Link Layer Discovery Protocol
34
Industry
INTERFACE
Fast Ethernet LEDs Alarm Contacts (DO)
RJ45 Ports: Device: • 2 relay outputs
• 10/100Base-T(X), auto MDI/MDI-X, auto • ALARM, PWR1, PWR2, DI1, DI2, • Carry current 2A @ 24VDC
negotiation R.M/CPLG.R, C.HD/C.TL Reset Button
Gigabit Ethernet Combo Ports Ports: • 1 set
RJ45 Ports: • 100/1000M (SFP port), 10/100/1000M (GbE
• 10/100/1000Base-T, auto MDI/MDI-X, auto RJ45 port), 10/100M (FE RJ45 port), LINK/
negotiation ACT
Ethernet Switches
MANAGEMENT
Software Configuration
• STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/v2/v3, • Web Browser, Cisco-like Telnet CLI, USB Local Console, SNMP,
IGMP Query v1/v2, GARP, GMRP, VLAN, SSH, DNS, HTTP, MODBUS TCP, IEXplorer Utility
HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP MIB
Traps, TFTP, RMON, LLDP, BootP Server/Client, DHCP • MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/P-Bridge
Server/Client, DHCP L2 Relay, DHCP Relay Option 82, MIB, IF MIB, Traceroute MIB, TCP MIB, UDP MIB, IP MIB, RMON
DHCP Option 66/67, Telnet, Syslog, SMTP, SNTP Server/ Group 1, 2, 3, 9, Delta Private MIB
Client, IPv6, MODBUS TCP, EtherNet/IP
Security
• MAC/IP/TCP/UDP filtering, HTTPS, SSH, 802.1X,
TACACS+, SNMP v3
IIoT Routers
POWER REQUIREMENTS
Input Voltage Overload Current Protection Voltage Dips Protection Time
• 2 sets, 12 to 48 VDC redundant terminal • Present, max. input current 3A • Min. 12ms at 24VDC
block input Reverse Polarity Protection
lnput Current • Present
• Max. 0.95A
PHYSICAL
Housing Weight
• IP40 metal case • 564g
Dimensions Installation
• 145.3 mm (H) x 75 mm (W) x 108.7 mm (D) • Industrial DIN-Rail and wall mounting
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -40℃ to 75℃ (-40˚F to 167˚F) • -40℃ to 85℃ (-40˚F to 185˚F) • 5% to 95% (non-condensing)
35
Industry
APPROVALS
Safety Environmental Type Tests Freefall:
• UL 508, EN 60950-1, IEC 61131-2 Cold Temperature: • IEC 60068-2-32
• IEC 60068-2-1 Vibration:
EMI
Dry Heat: • IEC 60068-2-6
• FCC 47 CFR Part 15 Subpart B Class A,
• IEC 60068-2-2 Hi-Pot:
IEC 61000-6-4, EN 55022(CISPR22)
Humidity: • 1.5KV
EMS [IEC 61000-6-2, EN 55024(CISPR24)] • IEC 60068-2-30
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, Shock:
IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, • IEC 60255-21-2
Ethernet Switches
IEC 61000-4-6 level 3, IEC 61000-4-8 level 4,
IEC 61000-4-29
Ordering Information
Product Port Combination Interface
Combo Port
Operating 10/100/1000 10/100 DO Power
Model Name 10/100/1000Base-T DI
Temperature Base-T Base-T(X) (Relay) Input
and 100/1000Base-SFP
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver. See the LCP Series datasheets for product information.
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48VDC Industrial Power Supply
IIoT Routers
36
Industry
DVS-109 series
Managed Industrial 8-Por t FE + 1-Por t GbE
Ethernet Switches
Ethernet Switches
► IPv6 address suitable for larger network and ► Broadcast/Multicast/Unknown Unicast storm
neighbor discovery control improves throughput problems
► Automatic IP assignment by DHCP/BootP server ► Loopback-Detection to avoid broadcast loops, and
for easy network construction shutdown the corresponding ports automatically
► DHCP relay option 82 for sending DHCP requests ► Cable diagnostic provides the mechanism to detect
with clients’ identities to a DHCP server and report potential cabling issues
► Port-based DHCP server with IP and MAC binding ► Intelligent Access Control List (ACL)
makes IP maintenance much easier* ► MAC addresses locking function per port blocks
► SNMP v1/v2c/v3 facilitates the exchange of unauthorized access
management between network devices ► USB console interface for easy connection with
IEEE 802.11 WLAN
Specifications
TECHNOLOGY
Standard Compliance • IEEE 802.1w Rapid Spanning Tree Protocol • IEEE 802.1AB Link Layer
• IEEE 802.3 10Base-T • IEEE 802.1s Multiple Spanning Tree Protocol Discovery Protocol
• IEEE 802.3u 100Base-T(X) and 100Base-FX • IEEE 802.1p Class of Service, Priority Processing Type
• IEEE 802.3ab 1000Base-T Protocols • Store and Forward
• IEEE 802.3x Flow Control • IEEE 802.1Q VLAN Tagging • IEEE 802.3x Flow control in
• IEEE 802.1D Spanning Tree Protocol • IEEE 802.1X Port Authentication full duplex, back-pressure flow
• IEEE 802.3ad LACP Aggregation control in half duplex
37
Industry
INTERFACE
Fast Ethernet LEDs Alarm Contacts (DO)
RJ45 Ports: Device: • 1 relay output
• 10/100Base-T(X), auto MDI/MDI-X, auto • ALARM, PWR1, PWR2, DI, R.M/CPLG.R, • Carry current 2A@24VDC
negotiation C.HD/C.TL Reset Button
Gigabit Ethernet Ports: • 1 set
RJ45 Ports: • 10/100/1000M(GbE RJ45 port), 10/100M(FE
• 10/100/1000Base-T, auto MDI/MDI-X, RJ45 port), LINK/ACT
auto negotiation Digital Inputs (DI)
Console Port • 1 set
Ethernet Switches
• RS-232 (USB B-Type connector) • 0~+5V is OFF
• +11V~30V is ON
• Max. input current 6mA
Security
• MAC/IP/TCP/UDP filtering, HTTPS, SSH, 802.1x, TACACS+,
SNMP v3
IIoT Routers
POWER REQUIREMENTS
Input Voltage Overload Current Protection Voltage Dips Protection Time
• 2 sets, 12 to 48VDC redundant terminal block • Present, max. Input current 3A • Min. 12ms at 24VDC
input Reverse Polarity Protection
lnput Current • Present
• Max. 0.58A
PHYSICAL
Housing Weight
• IP40 metal case • 500g
Dimensions Installation
• 145.3 mm (H) x 75 mm (W) x 108.7 mm (D) • Industrial DIN-Rail and wall mounting
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -40℃ to 75℃ (-40˚F to 167˚F) • -40℃ to 85℃ (-40˚F to 185˚F) • 5% to 95% (non-condensing)
38
Industry
APPROVALS
Safety Environmental Type Tests Freefall:
• UL 508, EN 60950-1, IEC 61131-2 Cold Temperature: • IEC 60068-2-32
EMI • IEC 60068-2-1 Vibration:
• FCC 47 CFR Part 15 Subpart B Class A, Dry Heat: • IEC 60068-2-6
IEC 61000-6-4, EN 55022(CISPR22) • IEC 60068-2-2 Hi-Pot:
Humidity: • 1.5KV
EMS [IEC 61000-6-2, EN 55024(CISPR24)] • IEC 60068-2-30
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, Shock:
IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, • IEC 60255-21-2
Ethernet Switches
Ordering Information
Product Port Combination Interface
Combo Port
Operating 10/100/1000 10/100 DO Power
Model Name 10/100/1000Base-T DI
Temperature Base-T Base-T(X) (Relay) Input
and 100/1000Base-SFP
IEEE 802.11 WLAN
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48VDC Industrial Power Supply
IIoT Routers
39
Industry
DVS-108 series
Managed Industrial 6-Por t FE + 2-Por t GbE
Combo 100/1000Base-SFP Ethernet Switches
Ethernet Switches
► IPv6 address suitable for larger network and ► Broadcast/Multicast/Unknown Unicast storm
neighbor discovery control improves throughput problems
► Automatic IP assignment by DHCP/BootP server ► Loopback-Detection to avoid broadcast loops, and
for easy network construction shutdown the corresponding ports automatically.
► DHCP relay option 82 for sending DHCP requests ► Cable diagnostic provides the mechanism to
with clients’ identities to a DHCP server detect and report potential cabling issues
► Port-based DHCP server with IP and MAC binding ► Intelligent Access Control List (ACL)
makes IP maintenance much easier* ► MAC addresses locking function per port blocks
► SNMP v1/v2c/v3 facilitates the exchange of unauthorized access
management between network devices ► USB console interface for easy connection with
IIoT Routers
critical applications ► Versatile system file updates by TFTP, HTTPS or
► IEEE 802.1Q VLAN, MAC-based VLAN*, IP HTTP
Subnet-based VLAN*, VLAN isolation* and GVRP ► DDM diagnosis function by SFP fiber module
optimize network strategy ► Auto warning by email, DI, relay, Syslog & SNMP
► Enhanced network security with IEEE 802.1X, trap
TACACS+, SSH, HTTPS and SNMP v3 ► Compatible with various industrial protocols,
► IEEE 802.3ad port trunking in parallel to increase including EtherNet/IP, Profinet, CC-LINK IE and
the link bandwidth DNP 3.0
► SNTP (simple network time protocol) for network
*Please check DELTA website for the latest firmware version
clock synchronization
Specifications
TECHNOLOGY
Standard Compliance • IEEE 802.1w Rapid Spanning Tree Protocol • IEEE 802.1AB Link Layer
• IEEE 802.3 10Base-T • IEEE 802.1s Multiple Spanning Tree Protocol Discovery Protocol
• IEEE 802.3u 100Base-T(X) and 100Base-FX • IEEE 802.1p Class of Service, Priority Processing Type
• IEEE 802.3ab 1000Base-T Protocols • Store and Forward
• IEEE 802.3z 1000Base-X • IEEE 802.1Q VLAN Tagging • IEEE 802.3x Flow control in
• IEEE 802.3x Flow Control • IEEE 802.1X Port Authentication full duplex, back-pressure flow
• IEEE 802.1D Spanning Tree Protocol • IEEE 802.3ad LACP Aggregation control in half duplex
40
Industry
INTERFACE
Fast Ethernet LEDs Alarm Contacts (DO)
RJ45 Ports: Device: • 2 relay outputs
• 10/100Base-T(X), auto MDI/MDI-X, auto • ALARM, PWR1, PWR2, DI1, DI2, • Carry current 2A@24VDC
negotiation R.M/CPLG.R, C.HD/C.TL Reset Button
Gigabit Ethernet Combo Ports Ports: • 1 set
RJ45 Ports: • 100/1000M (SFP port), 10/100/1000M (GbE
• 10/100/1000Base-T, auto MDI/MDI-X, RJ45 port), 10/100M (FE RJ45 port), LINK/
auto negotiation ACT
Ethernet Switches
• 8K
MANAGEMENT
Software Configuration
• STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/v2/v3, • Web Browser, Cisco-like Telnet CLI, USB Local Console, SNMP,
IGMP Query v1/v2, GARP, GMRP, VLAN, SSH, DNS, HTTP, MODBUS TCP, EtherNet/IP, IEXplorer Utility
HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP MIB
Traps, TFTP, RMON, LLDP, BootP Server/Client, DHCP • MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/P-Bridge
Server/Client, DHCP L2 Relay, DHCP Relay Option 82, MIB, IF MIB, Traceroute MIB, TCP MIB, UDP MIB, IP MIB, RMON
DHCP Option 66/67, Telnet, Syslog, SMTP, SNTP Server/ Group 1,2,3,9, Delta Private MIB
Client, IPv6, MODBUS TCP, EtherNet/IP
Security
• MAC/IP/TCP/UDP filtering, HTTPS, SSH, 802.1X,
TACACS+, SNMP v3
IIoT Routers
POWER REQUIREMENTS
Input Voltage Overload Current Protection Voltage Dips Protection Time
• 2 sets, 12 to 48 VDC redundant terminal • Present, max. input current 3A • Min. 12ms at 24VDC
block input Reverse Polarity Protection
lnput Current • Present
• Max. 0.87A
PHYSICAL
Housing Weight
• IP40 metal case • 520g
Dimensions Installation
• 145.3 mm (H) x 75 mm (W) x 108.7 mm (D) • Industrial DIN-Rail and wall mounting
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -40℃ to 75℃ (-40˚F to 167˚F) • -40℃ to 85℃ (-40˚F to 185˚F) • 5% to 95% (non-condensing)
41
Industry
APPROVALS
Safety Environmental Type Tests Freefall:
• UL 508, EN 60950-1, IEC 61131-2 Cold Temperature: • IEC 60068-2-32
EMI • IEC 60068-2-1 Vibration:
• FCC 47 CFR Part 15 Subpart B Class A, Dry Heat: • IEC 60068-2-6
IEC 61000-6-4, EN 55022(CISPR22) • IEC 60068-2-2 Hi-Pot:
Humidity: • 1.5KV
EMS [IEC 61000-6-2, EN 55024(CISPR24)] • IEC 60068-2-30
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, Shock:
IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, • IEC 60255-21-2
Ethernet Switches
IEC 61000-4-6 level 3, IEC 61000-4-8 level 4,
IEC 61000-4-29
Ordering Information
Product Port Combination Interface
Combo Port
Operating 10/100/1000 10/100 DO Power
Model Name 10/100/1000Base-T DI
Temperature Base-T Base-T(X) (Relay) Input
and 100/1000Base-SFP
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver. See the LCP Series datasheets for product information.
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48VDC Industrial Power Supply
IIoT Routers
42
Industry
DVS-103I02C-DLR
EtherNet/IP DLR Industrial 3-Port FE Ethernet Switches
Ethernet Switches
6 0 0
4 4
Specifications
TECHNOLOGY
Standard Compliance Processing Type
• IEEE 802.3 10Base-T • Store and Forward
• IEEE 802.3u 100Base-T(X)
IIoT Routers
INTERFACE
Fast Ethernet DIP Switches Alarm Contacts(DO)
RJ45 Ports: • Configuration for DHCP/ • 1 relay output
• 3 10/100Base-T(X), auto MDI/MDI-X, auto BootP, Factory Default, • Carry current 2A@24VDC
negotiation DLR Enable/Disable
LEDs Digital Inputs (DI)
Per Device: • 1 set
• PWR1/PWR2, DLR, DI, ALARM • 0~+5V is OFF
Per Port: • +11V~30V is ON
• LINK, ACT • Max. input current 6mA
MANAGEMENT
Software Configuration
• EtherNet/IP, IGMP Snooping v1/v2, VLAN, • Delta EIP Builder, EtherNet/IP EDS(Electronic Data Sheet) file
DHCP/BootP Client Firmware Upgrade
• Web Browser
DLR Mode
• Supervisor, Ring
43
Industry
POWER REQUIREMENTS
Input Voltage Overload Current Protection
• 2 sets, 12 to 48VDC redundant terminal block • Present, max. Input current 0.9A
input Reverse Polarity Protection
lnput Current • Present
• Max. 0.31A
PHYSICAL
Ethernet Switches
Housing Weight
• IP40 PC plastic • 126g
Dimensions Installation
• 110 mm (H) x 28 mm (W) x 75 mm (D) • Industrial DIN-Rail and wall mounting
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -20℃ to 70℃ (-4˚F to 158˚F) • -20℃ to 70℃ (-4˚F to 158˚F) • 5% to 95% (non-condensing)
APPROVALS
Safety Environmental Type Tests Freefall:
Ordering Information
IIoT Routers
Product Port Combination Interface
Operating DO
Model Name 10/100Base-T(X) DI Power Input
Temperature (Relay)
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48VDC Industrial Power Supply
44
Industry
DVS-G008W01 Series
Unmanaged Industrial 8-Port GbE Ethernet Switches
61010
Ethernet Switches
Specifications
IEEE 802.11 WLAN
TECHNOLOGY
Standard Compliance Processing Type
• IEEE 802.3 10Base-T • Store and forward
• IEEE 802.3u 100Base-T(X) and 100Base-FX • IEEE 802.3x flow control in full duplex, back-pressure flow control in half duplex
• IEEE 802.3ab 1000Base-T
• IEEE 802.3x Flow Control
INTERFACE
Gigabit Ethernet LEDs Alarm Contacts (DO)
RJ45 Ports: Per Device: • 1 relay output, carry current
• 10/100/1000Base-T, auto MDI/MDI-X, • ALARM, PWR1, PWR2 1.5A @ 24 VDC
IIoT Routers
POWER REQUIREMENTS
Input Voltage Input Current Reverse Polarity Protection
• 2 sets, 12 to 48 VDC / 10 to 24 VAC • Max. 0.23A • Present
redundant terminal block input Overload Current Protection
• Present, max. input current 5A
PHYSICAL
Housing Weight
• IP30 Metal case • 500g
Dimensions Installation
• 95mm (H) x 40mm (W) x 100mm (D) • DIN-Rail and wall mounting
45
Industry
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -40℃ to 75℃ (-40˚F to 167˚F) • -40℃ to 85℃ (-40˚F to 185˚F) • 5% to 95% (non-condensing)
APPROVALS
Safety Environmental Type Tests Freefall:
• UL 61010, IEC 62368-1, RCM, KC Cold Temperature: • IEC 60068-2-32
Ethernet Switches
• IEC 60068-2-1 Vibration:
EMI
Dry Heat: • IEC 60068-2-6
• FCC 47 CFR Part 15 Subpart B Class A,
• IEC 60068-2-2 Hi-Pot:
IEC 61000-6-4, EN 55011, EN 55032 (CISPR 32)
Humidity: • 2.25KV
EMS [IEC 61000-6-2, IEC 61131-2, • IEC 60068-2-78
EN 55024, EN 55035] Shock:
• EN 61000-4-2 Level 3, EN 61000-4-3 Level 3, • IEC 60068-2-27
EN 61000-4-4 Level 3, EN 61000-4-5 Level 3,
EN 61000-4-6 Level 3, EN 61000-4-8 Level 4
Ordering Information
IIoT Routers
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48VDC Industrial Power Supply
46
Industry
DVS-G005I00A Series
Unmanaged Industrial 5-Por t GbE
Ethernet Switches
Ethernet Switches
Specifications
TECHNOLOGY
Standard Compliance Processing Type
• IEEE 802.3 10Base-T • Store and Forward
• IEEE 802.3u 100Base-T(X) • IEEE 802.3x flow control in full duplex, back-pressure flow control
• IEEE 802.3ab 1000Base-T in half duplex
• IEEE 802.3x Flow Control
• IEEE 802.1p Class of Service, Priority Protocols
IIoT Routers
INTERFACE
Gigabit Ethernet LEDs
RJ45 Ports: Per Device:
• 10/100/1000Base-T, auto MDI/MDI-X, auto • PWR
negotiation Per Port:
• 10/100/1000M, LINK/ACT
47
Industry
POWER REQUIREMENTS
Input Voltage Overload Current Protection Voltage Dips Protection Time
• 1 set, 12 to 48 VDC terminal block input • Present, max. input current 3A • Min. 13ms at 24VDC
Input Current Reverse Polarity Protection
• Max. 0.18A • Present
PHYSICAL
Housing Weight
Ethernet Switches
• IP40 metal case • 300g
Dimensions Installation
• 145.3mm (H) x 45mm (W) x 108.7mm (D) • Industrial DIN-Rail and wall mounting
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -10℃ to 60℃ (14˚F to 140˚F) • -40℃ to 85℃ (-40 ℉ to 185 ℉ ) • 5% to 95% (non-condensing)
APPROVALS
Safety Environmental Type Tests Freefall:
• UL 508, EN 60950-1, IEC 61131-2 Cold Temperature: • IEC 60068-2-32
EMI • IEC 60068-2-1 Vibration:
Dry Heat: • IEC 60068-2-6
Ordering Information
IIoT Routers
Product Port Combination Interface
Combo Port
Operating 10/100/1000 10/100 DO Power
Model Name 10/100/1000Base-T and DI
Temperature Base-T Base-T(X) (Relay) Input
100/1000Base-SFP
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48VDC Industrial Power Supply
48
Industry
DVS-016 Series
Unmanaged Industrial 16-Port FE Ethernet Switches
Ethernet Switches
Specifications
IEEE 802.11 WLAN
TECHNOLOGY
Standard Compliance Processing Type
• IEEE 802.3 10Base-T • Store and Forward
• IEEE 802.3u 100Base-T(X) and 100Base-FX • IEEE 802.3x flow control in full duplex,
• IEEE 802.3x Flow Control back-pressure flow control in half duplex
• IEEE 802.1p Class of Service, Priority Protocols
INTERFACE
Fast Ethernet LEDs DIP Switches
RJ45 Ports: Per Device: • Port link-down alarm configuration
Alarm Contacts (DO)
IIoT Routers
POWER REQUIREMENTS
Input Voltage Input Current Reverse Polarity Protection
• 2 sets, 12 to 48 VDC redundant terminal • Max. 0.6A • Present
block input Overload Current Protection Voltage Dips Protection Time
• Present, max. input current 3A • Min. 13ms at 24VDC
PHYSICAL
Housing Weight
• IP40 metal case • 490g
Dimensions Installation
• 145.3mm (H) x 75mm (W) x 108.7mm (D) • Industrial DIN-Rail and wall mounting
49
Industry
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -40℃ to 75℃ (-40˚F to 167˚F) • 40℃ to 85℃ (-40˚F to 185˚F) • 5% to 95% (non-condensing)
APPROVALS
Safety Environmental Type Tests Freefall:
• UL 508, EN 60950-1, IEC 61131-2 Cold Temperature: • IEC 60068-2-32
• IEC 60068-2-1 Vibration:
EMI
Dry Heat: • IEC 60068-2-6
• FCC 47 CFR Part 15 Subpart B Class B,
Ethernet Switches
• IEC 60068-2-2 Hi-Pot:
IEC 61000-6-4, EN 55022(CISPR22)
Humidity: • 1.5KV
EMS [IEC 61000-6-2, EN 55024(CISPR24)] • IEC 60068-2-30
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, Shock:
IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, • IEC 60255-21-2
IEC 61000-4-6 level 3, IEC 61000-4-8 level 4,
IEC 61000-4-29
Fiber Optics
100Base-FX
MultiMode SingleMode
Cable 62.5/125μm, 50/125μm 9/125μm
Ordering Information
IIoT Routers
Product Port Combination Interface
100Base-FX
Operating 10/100 DO Power
Model Name DI
Temperature Base-T(X) SC Connector, SC Connector, (Relay) Input
MultiMode, 5km SingleMode, 30km
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48VDC Industrial Power Supply
50
Industry
DVS-008 Series
Unmanaged Industrial 8-Port FE Ethernet Switches
Ethernet Switches
Specifications
TECHNOLOGY
Standard Compliance • IEEE 802.3x Flow Control Processing Type
• IEEE 802.3 10Base-T • IEEE 802.1p Class of Service, • Store and Forward
• IEEE 802.3u 100Base-T(X) and Priority Protocols • IEEE 802.3x flow control in full duplex,
100Base-FX back-pressure flow control in half duplex
INTERFACE
Fast Ethernet LEDs Alarm Contacts (DO)
RJ45 Ports: Per Device: • 1 relay output
IIoT Routers
POWER REQUIREMENTS
Input Voltage Input Current Reverse Polarity Protection
DVS-008W series: DVS-008W series: • Present
• 2 sets, 12 to 48 VDC redundant terminal • Max. 0.45A
block input DVS-008I00: Voltage Dips Protection Time
DVS-008I00: • Max. 0.18A DVS-008W series:
• 1 set, 12 to 48 VDC terminal block input • Min. 13ms at 24VDC
Overload Current Protection DVS-008I:
• Present, max. input current 3A • Min. 10ms at 24VDC
51
Industry
PHYSICAL
Housing Weight
• IP40 metal case DVS-008W series:
Dimensions • 430g
DVS-008W series: DVS-008I00:
• 145.3 mm (H) x 75 mm (W) x 108.7 mm (D) • 300g
DVS-008I00: Installation
• 145.3 mm (H) x 45 mm (W) x 108.7 mm (D) • Industrial DIN-Rail and wall mounting
ENVIRONMENTAL LIMITS
Ethernet Switches
Operating Temperature Storage Temperature
DVS-008W series: • -40℃ to 85℃ (-40˚F to 185˚F)
• -40℃ to 75℃ (-40˚F to 167˚F) Ambient Relative Humidity
DVS-008I00: • 5% to 95% (non-condensing)
• -10℃ to 60℃ (14˚F to 140˚F)
• Tested @ -25℃ to 70℃ (-13˚F to 158˚F)
APPROVALS
Safety Environmental Type Tests
• UL 508, EN 60950-1, IEC 61131-2 Cold Temperature: Shock:
EMI • IEC 60068-2-1 • IEC 60255-21-2
• FCC 47 CFR Part 15 Subpart B Class B, Dry Heat: Freefall:
IEC 61000-6-4, EN 55022(CISPR22), • IEC 60068-2-2 • IEC 60068-2-32
Humidity: Vibration:
EMS [IEC 61000-6-2, EN 55024(CISPR24)]
Fiber optics
100Base-FX
MultiMode SingleMode
Cable 62.5/125μm, 50/125μm 9/125μm
Wavelength 1310nm 1310nm
Max. TX Power -14dBm -8dBm
-20dBm(1)
Min. TX Power -15dBm Note: The actual link distance of a
-22.5dBm(2)
IIoT Routers
particular fiber optic link depends on the
RX Sensitivity -31dBm -31dBm
optical budget, the number of connectors
11dBm(1) and splices, and cabling quantity. Please
Optical Budget 16dBm
8.5dBm(2) measure and verify the actual link loss
Max. Link Distance 5km 30km values once the link is established to
(1) 62.5/125μm fiber optic cable (2) 50/125μm fiber optic cable identify any potential performance issues.
Ordering Information
Product Port Combination Interface
100Base-FX
Operating 10/100 DO Power
Model Name SC Connector, SC Connector, DI
Temperature Base-T(X) (Relay) Input
MultiMode, 5km SingleMode, 30km
DVS-008I00 -10℃ to 60℃ 8 --- --- --- --- 1
DVS-008W01 -40℃ to 75℃ 8 --- --- --- 1 2
DVS-008W01-MC01 -40℃ to 75℃ 7 1 --- --- 1 2
DVS-008W01-MC02 -40℃ to 75℃ 6 2 --- --- 1 2
DVS-008W01-SC01 -40℃ to 75℃ 7 --- 1 --- 1 2
DVS-008W01-SC02 -40℃ to 75℃ 6 --- 2 --- 1 2
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48VDC Industrial Power Supply
52
Industry
DVS-005 Series
Unmanaged Industrial 5-Port FE Ethernet Switches
Ethernet Switches
Specifications
IEEE 802.11 WLAN
TECHNOLOGY
Standard Compliance Processing Type
• IEEE 802.3 10Base-T • Store and forward
• IEEE 802.3u 100Base-T(X) and 100Base-FX • IEEE 802.3x flow control in full duplex, back-pressure flow control in half duplex
• IEEE 802.3x Flow Control
INTERFACE
Fast Ethernet LEDs DIP Switches
RJ45 Ports: Per Device: Port link-down alarm configuration
• 10/100Base-T(X), auto MDI/MDI-X, • ALARM, PWR1, PWR2 Alarm Contacts (DO)
auto negotiation Per Port: • 1 relay output
IIoT Routers
Fiber Optic Ports: • 100M (RJ45 port), 100M (fiber port), • Carry current 2A@24VDC
• 100Base-FX (SC connector), MultiMode or LINK/ACT
SingleMode
POWER REQUIREMENTS
Input Voltage Input Current Reverse Polarity Protection
DVS-005W series: • Max. 0.24A • Present
• 2 sets, 12 to 48 VDC redundant terminal Overload Current Protection Voltage Dips Protection Time
block power input • Present, max. input current 3A • Min. 13ms at 24VDC
DVS-005I00:
• 1 set, 12 to 48 VDC terminal block input
PHYSICAL
Housing Weight
• IP40 metal case • 300g
Dimensions Installation
• 145.3mm (H) x 45mm (W) x 108.7mm (D) • Industrial DIN-Rail and wall mounting
53
Industry
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
DVS-005W series: • -40℃ to 85℃ (-40˚F to 185˚F) • 5% to 95% (non-condensing)
• -40℃ to 75℃ (-40˚F to 167˚F)
DVS-005I00:
• -10℃ to 60℃ (14˚F to 140˚F)
• Tested @ -25℃ to 70℃ (-13˚F to 158˚F)
APPROVALS
Ethernet Switches
Safety Environmental Type Tests Humidity:
• UL 508, EN 60950-1, IEC 61131-2 Cold Temperature: • IEC 60068-2-30
• IEC 60068-2-1 Shock:
EMI
Dry Heat: • IEC 60255-21-2
• FCC 47 CFR Part 15 Subpart B Class B,
• IEC 60068-2-2 Freefall:
IEC 61000-6-4, EN 55022(CISPR22),
• IEC 60068-2-32
EMS [IEC 61000-6-2, EN 55024(CISPR24)] Vibration:
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, • IEC 60068-2-6
IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, Hi-Pot:
IEC 61000-4-6 level 3, IEC 61000-4-8 level 4, • 1.5KV
IEC 61000-4-29
Fiber optics
100Base-FX
Ordering Information
IIoT Routers
Product Port Combination Interface
100Base-FX
Operating 10/100 DO Power
Model Name DI
Temperature Base-T(X) SC Connector, SC Connector, (Relay) Input
MultiMode, 5km SingleMode, 30km
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48VDC Industrial Power Supply
54
Industry
DVS-G005I00C Series
Unmanaged Industrial 5-Port GbE Ethernet Switches
61010
Ethernet Switches
Specifications
IEEE 802.11 WLAN
TECHNOLOGY
Standard Compliance Processing Type
• IEEE 802.3 10Base-T • Store and forward
• IEEE 802.3u 100Base-T(X) • IEEE 802.3x flow control in full duplex, back-pressure flow control in half duplex
• IEEE 802.3ab 1000Base-T
• IEEE 802.3x Flow Control
INTERFACE
Gigabit Ethernet LEDs
RJ45 Ports: Per Device:
• 10/100/1000Base-T, auto MDI/MDI-X, • PWR1, PWR2
auto negotiation Per Port:
IIoT Routers
• 10/100/1000M, LINK/ACT
POWER REQUIREMENTS
Input Voltage Input Current Reverse Polarity Protection
• 2 sets, 12 to 48 VDC redundant terminal • Max. 0.3A • Present
block input Overload Current Protection
• Present, max. input current 0.5A
PHYSICAL
Housing Weight
• IP40 PC plastic • 125g
Dimensions Installation
• 110mm (H) x 28mm (W) x 75mm (D) • Industrial DIN-Rail and wall mounting
55
Industry
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -20℃ to 70℃ (-4˚F to 158˚F) • -40℃ to 85℃ (-40˚F to 185˚F) • 5% to 95% (non-condensing)
APPROVALS
Safety Environmental Type Tests Humidity:
• UL 61010, IEC 62368-1 Cold Temperature: • IEC 60068-2-30
Ethernet Switches
• IEC 60068-2-1 Shock:
EMI
Dry Heat: • IEC 60255-21-2
• FCC 47 CFR Part 15 Subpart B Class A,
• IEC 60068-2-2 Freefall:
IEC61000-6-4, EN 55032, AS/NZS CISPR 32
• IEC 60068-2-32
EMS [IEC61000-6-2, EN 55024] Vibration:
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, • IEC 60068-2-6
IEC 61000-4-4 level 3, IEC 61000-4-5 level 1, Hi-Pot:
IEC 61000-4-6 level 3, IEC 61000-4-8 level 4, • 500V
IEC 61000-4-17
Ordering Information
Combo Port
Operating 10/100/1000 10/100 DO Power
Model Name 10/100/1000Base-T and DI
Temperature Base-T Base-T(X) (Relay) Input
100/1000Base-SFP
Optional Products
IIoT Routers
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48VDC Industrial Power Supply
56
Industry
DVS-008W00-M12 Series
Unmanaged Industrial 8-Port FE M12 IP67
Ethernet Switches
5g
Vibration
6 0 0
Resistant 3
Ethernet Switches
► Strong 5g resistance designs with M12 connectors for extreme vibration environment
► IP67-rated waterproof and dustproof metal housing to prevent penetrating water and
micro dust ingress
► Transparent transmission of VLAN tagged packets
► 12 to 48 VDC redundant power input
► -40℃ to 75℃ wide operating temperature
► Compatible with various industrial protocols, including EtherNet/IP, Profinet, CC-LINK IE, and DNP 3.0
Specifications
IEEE 802.11 WLAN
TECHNOLOGY
Standard Compliance Processing Type
• IEEE 802.3 10Base-T • Store and Forward
• IEEE 802.3u 100Base-T(X) • IEEE 802.3x Flow control in full duplex,
• IEEE 802.3x Flow Control back-pressure flow control in half duplex
INTERFACE
Fast Ethernet LEDs
M12 Ports: Per Device:
IIoT Routers
POWER REQUIREMENTS
M12 Port Input Current Reverse Polarity Protection
• 1 A-coded 4-pin male connector • Max. 0.156A • Present
Input Voltage Overload Current Protection
• 2 sets, 12 to 48 VDC redundant input • Present, max. input current 3A
PHYSICAL
Housing Weight
• IP67 metal case • 355g
Dimensions Installation
• 194mm (H) x 62mm (W) x 25mm (D) • Industrial DIN-Rail and wall mounting
57
Industry
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -40℃ to 75℃ (-40˚F to 167˚F) • 40℃ to 85℃ (-40˚F to 185˚F) • 5% to 95% (non-condensing)
APPROVALS
Safety Environmental Type Tests Freefall:
• UL 61010, EN 62368-1 Cold Temperature: • IEC 60068-2-32
• IEC 60068-2-1 Vibration:
EMI
Dry Heat: • IEC 60068-2-6
• FCC 47 CFR Part 15 Subpart B Class A,
Ethernet Switches
• IEC 60068-2-2 Hi-Pot:
IEC 61000-6-4, EN 55032, EN55011,
Humidity: • 1.5KV
AS/NZS CISPR 32
• IEC 60068-2-30
EMS [IEC 61000-6-2, EN 55024] Shock:
• IEC 61000-4-2 level 2, IEC 61000-4-3 level 3, • IEC 600068-2-27
IEC 61000-4-4 level 3, IEC 61000-4-5 level 2,
IEC 61000-4-6 level 3, IEC 61000-4-8 level 4
Ordering Information
Combo Port
Operating 10/100/1000Base-T 10/100/ 10/ DO Power
Model Name DI
Temperature and 100/1000Base- 1000Base-T 100Base-T(X) (Relay) Input
SFP
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
IIoT Routers
CliQII/PMC Series: 48VDC Industrial Power Supply
58
Industry
DVS-G512W01-4GF Series
IEEE 802.3 af/at PoE+ Managed Industrial 8-Port GbE
(PSE) + 4-Port 100/1000Base-SFP Ethernet Switches
Ethernet Switches
► Cable diagnostic provides the mechanism to detect and report potential cabling issues
► Intelligent Access Control List (ACL)
► MAC addresses filtering function per port blocks unauthorized access
► IGMP snooping prunes multicast traffic
► Port mirroring for Many-to-One ports online troubleshooting
► DDM snooping function by SFP fiber module
► Auto warning by email, relay, Syslog & SNMP trap
► Compatible with various industrial protocols, including EtherNet/IP, Profinet, CC-LINK IE and DNP 3.0
Specifications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T • IEEE 802.1D Spanning Tree Protocol
• IEEE 802.3u 100Base-T(X) and 100Base-FX • IEEE 802.1w Rapid Spanning Tree Protocol
• IEEE 802.3ab 1000Base-T • IEEE 802.1s Multiple Spanning Tree Protocol
• IEEE 802.3z 1000Base-X • IEEE 802.1p Class of Service, Priority Protocols
• IEEE 802.3x Flow Control • IEEE 802.1Q VLAN Tagging
59
Industry
TECHNOLOGY
Standard Compliance Processing Type
• IEEE 802.1X Port Authentication • Store and Forward
• IEEE 802.3ad LACP Aggregation • IEEE 802.3x Flow control in full duplex, back-pressure flow control in half duplex
• IEEE 802.1AB Link Layer Discovery Protocol
• IEEE 1588v2 Clock Synchronization
• IEEE 802.3af PoE 15.4 Watts
• IEEE 802.3at PoE 30 Watts
Ethernet Switches
INTERFACE
Gigabit Ethernet LEDs Alarm Contacts(DO)
RJ45 Ports: Device: • 1 relay output
• 8 10/100/1000Base-T, auto MDI/MDI-X, • STATUS, PWR1, PWR2, R.M, RING, ALARM • Carry current 1 A@24VDC
auto negotiation Ports: Reset Button
SFP Ports: • 100/1000M (SFP port), 10/100/1000M (RJ45 • 1 set
• 4 100/1000Base-SFP port), PoE+
PoE+ Pinout:
• 1 & 2 DC +, 3 & 6 DC -
Console Port:
• RS-232 (RJ45 connector)
MANAGEMENT
Software Security
• STP/RSTP/MSTP, LACP, QoS, IGMP Snooping v1/ • MAC/IP/TCP/UDP filtering, HTTPS, SSH, 802.1x, TACACS+, SNMP v3
v2/v3, IGMP Query v1/v2, VLAN, SSH, DNS, HTTP,
Configuration
HTTPS, RADIUS, TACACS+, SNMP v1/v2c/v3, SNMP
• Web Browser, Cisco-like Telnet CLI , RJ45 console, SNMP
Traps, TFTP, RMON, LLDP, DHCP Server/Client,
IIoT Routers
DHCP Relay Option 82, Telnet, Syslog, SMTP, SNTP MIB
Client, DoS/DDoS auto prevention, MRP, MODBUS • MIB II, Bridge MIB, SNMP MIB, Ether-like MIB, Q-Bridge/P-Bridge MIB,
TCP IF MIB, Traceroute MIB, TCP MIB, UDP MIB, IP MIB, RMON Group 1,2,3,9,
Delta Private MIB
POWER REQUIREMENTS
Input Voltage Overload Current Protection
• 2 sets, 48 to 57 VDC redundant terminal block input • Present, max. input current 10A
Input Current Reverse Polarity Protection
• Max. 5.5A (with powered device); Max. 0.26A (without powered device) • NOT Present
PHYSICAL
Housing Weight
• IP30 metal case • 1205 g
Dimensions Installation
• 154 mm (H) x 96.4 mm (W) x 105.5 mm (D) • DIN-Rail and wall mounting
60
Industry
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -40℃ to 70℃ (-40˚F to 158˚F) • -40℃ to 85℃ (-40˚F to 185˚F) • 5% to 95% (non-condensing)
APPROVALS
Safety Environmental Type Tests
• EN 60950-1 Shock:
EMI • IEC 60068-2-27
Ethernet Switches
Ordering Information
Product Port Combination Interface
IEEE 802.11 WLAN
af/at PoE+,
Operating 100/1000 DO Power
Model Name 10/100/1000 DI
Temperature Base-SFP (Relay) Input
Base-T
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver. See the LCP Series datasheets for product information.
CliQII/PMC Series: 48 VDC Industrial Power Supply
IIoT Routers
61
Industry
DVS-G408W01 Series
IEEE 802.3af/at PoE+ Unmanaged Industrial 8-Port GbE
Ethernet Switches
Ethernet Switches
3
IIoT Routers
INTERFACE
Gigabit Ethernet LEDs DIP Switches
RJ45 Ports: Per Device: • Power failure alarm
• 10/100/1000Base-T, auto MDI/MDI-X, auto negotiation • PWR1, PWR2, ALARM Alarm Contacts (DO)
PoE+ Pinout: Per Port: • 1 relay output
• 1 & 2 DC+, 3 & 6 DC- • PoE, 10/100/1000M, • Carry current 1A@24VDC
LINK/ACT
62
Industry
POWER REQUIREMENTS
Input Voltage Overload Current Protection
• 2 sets, 48 to 57 VDC redundant terminal block input • Present, max. input current 10A
Input Current Reverse Polarity Protection
• Max. 5A (with powered device); Max. 0.16A (without powered device) • NOT Present
PHYSICAL
Housing Weight
Ethernet Switches
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -40℃ to 70℃ (-40˚F to 158˚F) • -40℃ to 85℃ (-40˚F to 185˚F) • 5% to 95% (non-condensing)
APPROVALS
Safety
• EN 60950-1
EMI
IEEE 802.11 WLAN
Ordering Information
Product Port Combination Interface
Optional Products
CliQII/PMC Series: 48 VDC Industrial Power Supplies
63
Industry
DVS-G406W01-2GF Series
IEEE 802.3af/at PoE+ Unmanaged Industrial 4-Port
GbE + 2-Port 100/1000Base-SFP Ethernet Switches
Ethernet Switches
3
IIoT Routers
• IEEE 802.3x Flow Control
• IEEE 802.3af PoE 15.4 Watts
• IEEE 802.3at PoE 30 Watts
INTERFACE
Gigabit Ethernet LEDs DIP Switches
RJ45 Ports: Per Device: • Power failure alarm
• 10/100/1000Base-T, auto MDI/MDI-X, auto negotiation • PWR1, PWR2, ALARM • SFP speed
PoE+ Pinout: Per Port: Alarm Contacts (DO)
• 1 & 2 DC+, 3 & 6 DC- • PoE, 10/100/1000M, • 1 relay output
SFP Ports: LINK/ACT • Carry current 1A@24VDC
• 100/1000Base-SFP
64
Industry
POWER REQUIREMENTS
Input Voltage Overload Current Protection
• 2 sets, 48 to 57 VDC redundant terminal block input • Present, max. input current 10A
Input Current Reverse Polarity Protection
• Max. 2.52A (with powered device); Max. 0.13A (without powered device) • NOT Present
PHYSICAL
Housing Weight
Ethernet Switches
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -40℃ to 70℃ (-40˚F to 158˚F) • -40℃ to 85℃ (-40 ℉ to 185 ℉ ) • 5% to 95% (non-condensing)
APPROVALS
Safety
• EN 60950-1
EMI
• FCC 47 CFR Part 15 Subpart B Class A, EN 55022 (CISPR22)
IEEE 802.11 WLAN
EMS
• IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6
Ordering Information
Product Port Combination Interface
Model Name DI
Temperature 10/100/1000Base-T 1000Base-SFP (Relay) Input
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver. See the LCP Series datasheets for product information.
CliQII/PMC Series: 48 VDC Industrial Power Supplies
65
Industry
DVS-G402R00-INJ Series
2 10/100/1000Base-T Industrial IEEE 802.3af/at
PoE+ Injectors
Ethernet Switches
3
IIoT Routers
INTERFACE
Gigabit Ethernet LEDs
RJ45 Ports: Device:
• 2 10/100/1000Base-T PoE+ OUT, 2 10/100/1000Base-T • PWR
DATA IN, auto MDI/MDI-X, auto negotiation Port:
PoE+ Pinout: • PoE+
• 1 & 2 DC +, 3 & 6 DC -
POWER REQUIREMENTS
Input Voltage PoE+ Output Power
• 2 sets, 12 to 57 VDC redundant terminal block input • Max. 600mA @ 50 VDC, 30 watts per port
Input Current Overload Current Protection
• Max. 5.5A (with powered device) • Present, max. input current 10A
Reverse Polarity Protection
• Present
66
Industry
PHYSICAL
Housing Weight
• IP30 metal case • 370g
Dimensions Installation
• 95 mm(H) x 41 mm(W) x 70 mm (D) • DIN-Rail and wall mounting
ENVIRONMENTAL LIMITS
Operating Temperature Ambient Relative Humidity
Ethernet Switches
APPROVALS
Safety
• EN 60950-1
EMI
• FCC 47 CFR Part 15 Subpart B Class A, EN 55022 (CISPR22)
EMS
• IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8
Environmental Type Tests
IEEE 802.11 WLAN
Shock:
• IEC 60068-2-27
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Ordering Information
Product Port Combination Interface
IIoT Routers
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48 VDC Industrial Power Supply
67
Industry
DVS-G401R00-SPL Series
1 10/100/1000Base-T Industrial IEEE 802.3af/at
PoE+ Splitters
Ethernet Switches
3
IIoT Routers
INTERFACE
Gigabit Ethernet LEDs
RJ45 Ports: Device:
• 1 10/100/1000Base-T PoE+ IN, 1 10/100/1000Base-T • PWR
DATA OUT, auto MDI/MDI-X, auto negotiation
PoE+ Pinout:
• PD auto negotiation (1 & 2 DC +, 3 & 6 DC- or 4 & 5
DC +, 7 & 8 DC-)
POWER REQUIREMENTS
PoE+ Input Voltage Output Current
• 36 to 57 VDC • Max. 1.125A
Output Voltage Overload Current Protection
• 2 sets, 24 VDC redundant terminal block • Present, adjust by PoE power classes
Reverse Polarity Protection
• Present
68
Industry
PHYSICAL
Housing Weight
• IP30 metal case • 250g
Dimensions Installation
• 95 mm(H) x 26.1 mm(W) x 70 mm (D) • DIN-Rail and wall mounting
ENVIRONMENTAL LIMITS
Operating Temperature Ambient Relative Humidity
Ethernet Switches
APPROVALS
Safety
• EN 60950-1
EMI
• FCC 47 CFR Part 15 Subpart B Class A, EN 55022 (CISPR22)
EMS (EN 55024)
• IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
Environmental Type Tests
IEEE 802.11 WLAN
Shock:
• IEC 60068-2-27
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Ordering Information
Product Port Combination Interface
IIoT Routers
69
Industry
DVS-G002I00C-TF Series
Industrial 1-Port 100/1000Base-T to
100/1000Base-SFP Media Converter
61010
Ethernet Switches
► 12 to 48 VDC redundant terminal block power input
► Supports Link fault Pass-Through (LFP)
► Jumbo frame size up to 10K Bytes
► -20℃ to 70℃ operating temperature
Specifications
INTERFACE
Gigabit Ethernet LEDs
RJ45 Ports: Per Device:
• 100/1000Base-T, auto MDI/MDI-X, auto negotiation • PWR1, PWR2
IIoT Routers
SFP Ports: Per Port:
• 100/1000Base-SFP • 100/1000M(RJ45 port), 100/1000M(SFP port), LINK/ACT
DIP Switch
• 100M or 1000M selection
POWER REQUIREMENTS
Input Voltage Overload Current Protection
• 2 set, 12 to 48 VDC redundant terminal block input • Present, max. input current 0.5A
Input Current Reverse Polarity Protection
• Max. 0.15A • Present
70
Industry
PHYSICAL
Housing Weight
• IP40 PC plastic • 110g
Dimensions Installation
• 110mm (H) x 28mm (W) x 75mm (D) • Industrial DIN-Rail and wall mounting
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
Ethernet Switches
• -20℃ to 70℃ (-4˚F to 158˚F) • -40℃ to 85℃ (-40 ℉ to 185 ℉ ) • 5% to 95% (non-condensing)
APPROVALS
Safety Environmental Type Tests Freefall:
• UL 61010, IEC 62368-1 Cold Temperature: • IEC 60068-2-32
• IEC 60068-2-1 Vibration:
EMI
Dry Heat: • IEC 60068-2-6
• FCC 47 CFR Part 15 Subpart B Class A,
• IEC 60068-2-2 Hi-Pot:
IEC61000-6-4, EN 55032, AS/NZS CISPR 32
Humidity: • 500V
EMS [IEC61000-6-2, EN 55024]
• IEC 60068-2-30
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3,
Shock:
IEC 61000-4-4 level 3, IEC 61000-4-5 level 1,
• IEC 60255-21-2
IEC 61000-4-6 level 3, IEC 61000-4-8 level 4,
IEC 61000-4-17
IEEE 802.11 WLAN
Ordering Information
Product Port Combination Interface
Optional Products
LCP Series: 100Base-FX/1000Base-X SFP Fiber Transceiver. See the LCP Series datasheets for product information.
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48VDC Industrial Power Supply
71
Industry
LCP-GbE Series
1-Port Gigabit Ethernet SFP Fiber
Transceivers
Ethernet Switches
► Supports IEEE 802.3x flow control
► DDM diagnosis function enhances transmission quality
► Duplex LC connector interface
► Hot-Pluggable for maximum flexibility
► TTL signal detection indicator
► Class 1 laser product (Compliant with EN 60825-1)
► Metal case for better EMI immunity
► Wide operating temperature
INTERFACE
Gigabit Ethernet
• Port number: 1
• Connectors: Duplex LC
IIoT Routers
Basic Information Enhanced Parameters
• Ethernet Compliance Code, Vendor Name, • Temperature, Supply Voltage, Transmitted Bias Current,
Wavelength, Distance Transmitted Power, Received Power
Note1: All Enhanced Parameters listed above include alarm and warning thresholds
Note2: DDM function is fully compatible with Delta DVS series Industrial Ethernet Switches
Fiber Optics
1000Base-X
LCP-1000SX LCP-1000LX10 LCP-1000LHX40
Cable 50/125μm MultiMode 9/125μm SingleMode 9/125μm SingleMode
72
Industry
PHYSICAL
Housing Dimensions Installation
• Metal case • 8.5 mm (H) x 13.4 mm (W) x 57 mm (D) • Hot-swappable, pluggable
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
Standard Models: • -40℃ to 85℃ (-40˚F to 185˚F ) • 5% to 95% (non-condensing)
• -5℃ to 70℃ (23˚F to 158˚F)
Ethernet Switches
APPROVALS
Safety EMI
• UL 60950-1, EN 60950-1 • FCC 47 CFR Part 15 Subpart B Class B, EN 55032
Laser Eye Safety EMS
• EN 60825-1 • EN 55024
Ordering Information
IEEE 802.11 WLAN
Product Interface
Standard Wide
Temperature Max.
Temperature Connectors Fiber Type Link Distance
-5℃ to 70℃ -40℃ to 85℃
Note: The actual link distance of a particular fiber optic link depends on the optical budget, the number of connectors and splices, and cabling quantity. Please measure and verify the
IIoT Routers
actual link loss values once the link is established to identify any potential performance issues.
73
Industry
LCP-1FE Series
1-Port Fast Ethernet SFP Fiber
Transceivers
Ethernet Switches
► Full duplex operation
► Supports IEEE 802.3x flow control
► DDM diagnosis function enhances transmission quality
► Duplex LC connector interface
► Hot-Pluggable for maximum flexibility
► TTL signal detection indicator
► Class 1 laser product (Compliant with EN 60825-1)
► Metal case for better EMI immunity
► Wide operating temperature
INTERFACE
Fast Ethernet
• Port number: 1
IIoT Routers
• Connectors: Duplex LC
Note1: All Enhanced Parameters listed above include alarm and warning thresholds
Note2: DDM function is fully compatible with Delta DVS series Industrial Ethernet Switches
Fiber Optics
100Base-FX
LCP-100MMF LCP-100SMF30 LCP-100SMF60
Cable 62.5/125μm MultiMode 9/125μm SingleMode 9/125μm SingleMode
74
Industry
PHYSICAL
Housing Dimensions Installation
• Metal case • 8.5 mm (H) x 13.4 mm (W) x 57 mm (D) • Hot-swappable, pluggable
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
Standard Models: • -40℃ to 85℃ (-40˚F to 185˚F) • 5% to 95% (non-condensing)
• -5℃ to 70℃ (23˚F to 158˚F)
Wide Temp. Models:
Ethernet Switches
APPROVALS
Safety EMI
• UL 60950-1, EN 60950-1 • FCC 47 CFR Part 15 Subpart B Class B, EN 55032
Laser Eye Safety EMS
• EN 60825-1 • EN 55024
Ordering Information
IEEE 802.11 WLAN
Product Interface
Standard Wide
Temperature Temperature Connectors Fiber Type Max.
Link Distance
-5℃ to 70℃ -40℃ to 85℃
Note: The actual link distance of a particular fiber optic link depends on the optical budget, the number of connectors and splices, and cabling quantity. Please measure and verify the
actual link loss values once the link is established to identify any potential performance issues.
IIoT Routers
75
Industry
IEEE 802.11 WLAN
Functions
Wireless Management ............................................................................................................................................................................... 75
Wireless AP
DVW-W02W2-E2 Series: Industrial IEEE 802.11 a/b/g/n Wireless AP/WDS/Client/Gateway ...................................................................... 80
Ethernet Switches
DVW-W01I2-E1 Series: Industrial IEEE 802.11 a/b/g/n/ac Wireless AP/Client/Gateway ............................................................................. 83
High-gain Antennas
DVW-ANTRM8N-B3 Series: 2.4 & 5GHz Dual-band Omni-directional 5.5 & 8dBi High-gain Antennas ....................................................... 86
76
Industry
Voice Traffic
▲STP/RSTP
Incorrect wiring frequently causes loops that affect network
operation. STP/RSTP protects networks from this type of harm
and builds a redundancy path which contributes to a highly
reliable network system.
Blocked
77
Industry
Versatile Wireless Spot
Master
▲Wireless Distribution Slave
Slave
System (WDS) Point-to-
Multipoint Mode
Replacing traditional wired LAN extensions, Slave
Slave
this mode enables a LAN extension of two
Ethernet Switches
or more LANs through wireless connection.
A Seamless Interconnection
▲USB Console Interface DVW NB
A simple USB cable is all you need to make network
IIoT Routers
management settings.
USB cable
78
Industry
MODBUS Cache
■ Speeds up data loading time
▲ ■ Online real-time monitoring
The DVW Series Wireless APs provide a dynamic and constant communication between equipments. Responses are given in
no time when the host requests via Ethernet, which significantly improves the data rates of serial equipments.
Ethernet Switches
Host
Ethernet Serial
IN
POWER
RUN
ERROR
COM1
Fast Response
DVP-12SA
0
1
IEEE 802.11 WLAN
Digital Inputs
Designed for industrial environments, the DVW Series Wireless APs easily connect to various industrial devices, such as
programmable logic controllers (PLC) or sensors, and deliver real-time alarms to users via relay output or email.
Alarm Indicators
79
Industry
Introduction to Serial Device Servers
▲Virtual COM ▲TCP Server
The virtual COM mode corresponds the serial port of a In a TCP/IP network, each serial port has one exclusive
DVW Series to the COM port of a PC, providing users with set of IP address and TCP serial port number. When
direct access from a PC to serial communication devices the host requests connection, a DVW Series passively
via wired or wireless communication. receives the request for connection and conducts
transmission of serial device data via wired or wireless
COM6 = 192.168.1.200:2000 communication.
Ethernet Switches
1
AH500 PLC AH500 PLC
Ethernet Ethernet
2
RS-232/422/485 RS-232/422/485
COM5 = 192.168.1.100:1000
IIoT Routers
1
AH500 PLC AH500 PLC
Ethernet Ethernet
2
RS-232/422/485
RS-232/422/485
▲Pair Connection
Pair a DVW Series with a serial host and another with a serial device. The pairs can use the existing wired or wireless network
for communication. When the distance exceeds 100m, replace the network cable with RS-485 communication for a longer
transmission distance of up to 1,200m.
Ethernet
Serial Device
AH500 PLC
IN
POWER
RUN
ERROR
COM1
DVP-12SA
RS-232/422/485 RS-232/422/485
80
Industry
RUN
ERROR
COM1
DVP-12SA
0
RS-232/422/485 RS-232/422/485
Ethernet Switches
PLC
SCADA
RS-485 POWER S/S
IN X3
X4
RUN
X5
X6
STOP X7
C0
Y0
DVP-12SE
COM1 OUT Y1
Y2
Y3
Ethernet Ethernet
SG
COM3+
COM3-
Ethernet
R
Ethernet
IIoT Routers
RS-485 RS-485
81
Industry
DVW-W02W2-E2
Industrial IEEE 802.11 a/b/g/n Wireless
AP/WDS/Client/Gateway
Ethernet Switches
► Compliant with IEEE 802.11n wireless technology capable
of up to 450Mbps data rate
► Backward compatible with 802.11 a/b/g standards for ► Built-in 20MB buffer memory avoids data loss
seamless integration once the connection is down
► Multiple Wireless Modes: AP, Client CPE, WDS P-T-P, WDS ► STP/RSTP for network redundancy further
P-T-MP and Repeater ensures reliability and avoids network loops
► 3 x 3 MIMO technology increases data rate ► Automatic IP assignment by DHCP/BootP
► Wireless QoS (IEEE 802.11e, WMM) for video packets server for easy network construction
IIoT Routers
collection other industrial devices
► Built-in 2-port MODBUS ASCII/RTU to MODBUS TCP ► CPU utilization displays the amount of work the
Gateway CPU handles
► Up to 32 TCP masters or 32 TCP slaves per port at the ► Auto warning by email, DI, relay, Syslog &
same time SNMP trap
Specifications
TECHNOLOGY
Standard Compliance Processing Type
• IEEE 802.11 a/b/g/n Wireless LAN • IEEE 802.3x Flow Control • CSMA/CA
• IEEE 802.11i Wireless Security • IEEE 802.1D Spanning Tree Protocol
• IEEE 802.11e QoS(WMM) • IEEE 802.1w Rapid Spanning Tree Protocol
• IEEE 802.3 10Base-T • IEEE 802.1Q VLAN Tagging
• IEEE 802.3u 100Base-T(X) • IEEE 802.1X Port Authentication
• IEEE 802.3ab 1000Base-T
INTERFACE
Wireless
IEEE 802.11 a/b/g/n: Antennas:
• 3T3R • 3 2dBi omni-directional, RP-SMA (male) connector
82
Industry
INTERFACE
Gigabit Ethernet Console Port
RJ45 Ports: • USB B-Type connector
• 2 10/100/1000Base-T, auto MDI/MDI-X, auto negotiation LEDs
Serial Communication Wireless Mode:
Serial Ports : • Client, AP/WDS
• 2 RS-232/422/485, Terminal Block (8 contacts per port), Device:
2KV isolation protection • Signal Strength, Status, PWR1, PWR2, DI, ALARM
Baud Rate: RJ45 Ports:
• 110bps to 921.6kbps • 10/100/1000M, LINK/ACT
Ethernet Switches
• 1 set
• Tx+, Tx-, Rx+, Rx-, GND
Wireless RF
RF Modulation RF Output Power (Max., per chain) Receiver Sensitivity
802.11a: 802.11a: 802.11a:
• BPSK, QPSK, 16QAM, 64QAM with OFDM • 6Mbps to 24Mbps: 17dBm (±2dBm) -93dBm @ 6Mbps, -85dBm @ 36Mbps
802.11b: • 36Mbps: 16dBm (±2dBm) -81dBm @ 48Mbps, -79dBm @ 54Mbps
• DBPSK, DQPSK with DSSS, CCK • 48Mbps: 14dBm (±2dBm) 802.11b:
802.11g: • 54Mbps: 13dBm (±2dBm) • -96dBm @ 1Mbps, -90dBm @ 11Mbps
• BPSK, QPSK, 16QAM, 64QAM with OFDM 802.11b (per chain): 802.11g:
802.11n: • 1Mbps to 11Mbps: 19dBm (±2dBm) • -94dBm @ 6Mbps, -86dBm @ 36Mbps
• BPSK, QPSK, 16QAM, 64QAM with MIMO- 802.11g: -82dBm @ 48Mbps, -80dBm @ 54Mbps
OFDM • 6Mbps to 36Mbps: 19dBm (±2dBm) Receiver Sensitivity MIMO
Frequency Band • 48Mbps: 18dBm (±2dBm) 802.11n(2.4G HT20):
IIoT Routers
83
Industry
MANAGEMENT
Software Security Configuration
• STP/RSTP, QoS, VLAN, SSH, DNS, Security Access: • Web Browser, Cisco-like Telnet
HTTP, HTTPS, RADIUS, SNMP v1/v2c/ • MAC/IP/TCP/UDP filtering, HTTPS, SSH, CLI, USB Local Console, SNMP,
v3, SNMP Traps, TFTP, BootP Server/ 802.1X, SNMP v3 MODBUS TCP, IEXplorer Utility
Client, DHCP Server/Client, Telnet, Wireless Security: MIB
Syslog, SMTP, SNTP Server/Client, ARP, • 802.11i, 64/128-bit WEP, WPA/WPA2, • MIB II, RS-232 MIB, System Group
MODBUS TCP WPA-PSK/WPA2-PSK (TKIP/AES) MIB, SNMP MIB, Interface Group
• SSID Broadcast: Enable/Disable MIB, TCP MIB, UDP MIB, IP MIB,
Virtual COM Drivers Delta Private MIB
Ethernet Switches
• Windows 2000, Windows XP
• Windows Vista (32/64 bits)
• Windows 7 (32/64 bits)
APPROVALS
Safety Environmental Type Tests
• UL 508, EN 60950-1, IEC 61131-2 Cold Temperature:
EMI • IEC 60068-2-1
• FCC 47 CFR Part 15 Subpart B Class A, Dry Heat:
• IEC 60068-2-2
• IEC 61000-6-4, EN 55022(CISPR22), EN 301 489-1/17
Humidity:
EMS • IEC 60068-2-30
[EN 301 489-1/17, IEC 61000-6-2, EN 55024(CISPR24)] Shock:
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3, • IEC 60255-21-2
IIoT Routers
IEC 61000-4-4 level 4, IEC 61000-4-5 level 3, Freefall:
IEC 61000-4-6 level 3, IEC 61000-4-8 level 4, • IEC 60068-2-32
IEC 61000-4-29 Vibration:
RF • IEC 60068-2-6
• EN 300 328, EN 301 893, NCC, SRRC Hi-Pot:
• FCC 47 CFR Part 15 Subpart C, E • 1.5KV
Ordering Information
Product Port Combination Interface RF
Region
Operating 10/100/1000 RS-232/422/485 DO Power
Model Name DI Band
Temperature Base-T (Relay) Input
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48 VDC Industrial Power Supply
84
Industry
DVW-W01I2-E1
Industrial IEEE 802.11 a/b/g/n/ac
Wireless AP/Client/Gateway
Ethernet Switches
0 6 0 0
4 4
► Compliant with IEEE 802.11ac wireless technology capable of up to 866Mbps data rate
► Compliant with IEEE 802.11n wireless technology capable of up to 300Mbps data rate
► Backward compatible with 802.11 a/b/g standard for seamless integratio
► Multiple Wireless Modes: AP, Client
► 2 x 2 MIMO technology increases data rate
► Proprietary ONE ROAMING industrial-grade fast roaming, seamless roaming recovery time between APs <
150ms
IEEE 802.11 WLAN
Specifications
TECHNOLOGY
Standard Compliance Processing Type
• IEEE 802.11 a/b/g/n/ac Wireless LAN • CSMA/CA
• IEEE 802.11i Wireless Security
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
• IEEE 802.3ab 1000Base-T
INTERFACE
Wireless
IEEE 802.11 a/b/g/n/ac:
• 2T2R
Antennas:
• 2 2dBi omni-directional, RP-SMA(male) connector
85
Industry
INTERFACE
Gigabit Ethernet LEDs
RJ45 Port: Device:
• 1 10/100/1000Base-T, auto MDI/MDI-X, auto negotiation • PWR1/PWR2, DI/ALARM, Signal Strength
Serial Communication RJ45 Port:
Serial Ports : • 10/100/1000M, LINK/ACT
• 1 RS-232 (5-pin terminal block), 1 RS-485(3-pin terminal block), Serial Ports:
2KV isolation protection • RS-232, RS-485
Baud Rate: Digital Inputs (DI)
• 2400bps to 115200bps • 1 set
Ethernet Switches
Data Bits: • 0~+5V is OFF
• 7, 8 • +11V~30V is ON
Parity: • Input current 6mA Max.
• None, Even, Odd
Stop Bits: Alarm Contacts (DO)
• 1, 2 • 1 relay output
Flow Control: • Carry current 1A@24VDC
• RTS/CTS (RS-232 only) Reset Button
RS-232: • 1 set
• TxD, RxD, RTS, CTS, GND
RS-485:
• D+, D-, GND
Wireless RF
IIoT Routers
• MCS0: 20dBm (±1.5dBm)
Operating Channels • MCS7: 18dBm (±1.5dBm) 802.11n (2.4G HT20):
US (FCC): 802.11n (5G HT20/40): • -92dBm @ MCS0, -72dBm @ MCS7
• 2.412GHz ~ 2.462GHz (11 channels) • MCS0: 21dBm (±1.5dBm) 802.11n (2.4G HT40):
• 5.180GHz ~ 5.240GHz (4 channels) • MCS7: 19dBm (±1.5dBm) • -90dBm @ MCS0, -70dBm @ MCS7
5.745GHz ~ 5.825GHz (5 channels) 802.11ac (5G HT20): 802.11n (5G HT20):
EU (ETSI): • MCS0: 21dBm (±1.5dBm) • -89dBm @ MCS0, -71dBm @ MCS7
• 2.412GHz ~ 2.472GHz (13 channels) • MCS8: 17dBm (±1.5dBm) 802.11n (5G HT40):
• 5.180GHz ~ 5.240GHz (4 channels) 802.11ac (5G HT40): • -87dBm @ MCS0, -68dBm @ MCS7
China (SRRC): • MCS0: 21dBm (±1.5dBm) 802.11ac (5G HT20)
• 2.412GHz ~ 2.472GHz (13 channels) • MCS8: 17dBm (±1.5dBm) • -89dBm @ MCS0, -66dBm @ MCS9
• 5.180GHz ~ 5.240GHz (4 channels) • MCS9: 15dBm (±1.5dBm) 802.11ac (5G HT40)
• 5.745GHz ~ 5.825GHz (5 channels) 802.11ac (5G HT80): • -86dBm @ MCS0, -61dBm @ MCS9
Taiwan (NCC): • MCS0: 19dBm (±1.5dBm) 802.11ac (5G HT80)
• 2.412GHz ~ 2.462GHz (11 channels) • MCS8: 16dBm (±1.5dBm) • -84dBm @ MCS0, -58dBm @ MCS9
• 5.280GHz ~ 5.320GHz (3 channels) • MCS9: 15dBm (±1.5dBm)
5.745GHz ~ 5.825GHz (5 channels)
Data Transmission Rates
802.11ac mode:
• up to 866Mbps
802.11n mode:
• up to 300Mbps
802.11a mode:
• 6, 9, 12, 18, 24, 36, 48, 54Mbp
802.11b mode:
• 1, 2, 5.5, 11Mbps
802.11g mode:
• 6, 9, 12, 18, 24, 36, 48, 54Mbps
86
Industry
MANAGEMENT
Software Security Configuration
• SSH, HTTPS, HTTP, TFTP, BootP Server/ Security Access: • Web Browser, MODBUS TCP,
Client, DHCP Server/Client, Telnet, • SSH IEXplorer utility
Syslog, ARP, MODBUS TCP, SNMP Wireless Security: MIB
• 802.11i, 64/128-bit WEP, WPA-PSK / • MIB II, RS-232 MIB, System Group
WPA2-PSK (TKIP/AES) MIB, SNMP MIB, Interface Group
• SSID Broadcast: Enable/Disable MIB, TCP MIB, UDP MIB, IP MIB,
Virtual COM Drivers Delta Private MIB
• Windows 2000, Windows XP
Ethernet Switches
ENVIRONMENTAL LIMITS
Operating Temperature Storage Temperature Ambient Relative Humidity
• -10℃ to 60℃ (14˚F to 140˚F) • -40℃ to 85℃ (-40˚F to 185˚F) • 5% to 95% (non-condensing)
APPROVALS
Safety Environmental Type Tests
• UL 61010, IEC 62368-1 Cold Temperature:
EMI • IEC 60068-2-1
• FCC 47 CFR Part 15 Subpart B Class A, IEC 61000-6-4, EN 55011, Dry Heat:
EN 55032(CISPR32), EN 301 489-1/17 • IEC 60068-2-2
EMS Humidity:
[EN 301 489-1/17, IEC 61000-6-2, EN 55024(CISPR24)] • IEC 60068-2-30
• IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, Shock:
• IEC 60255-21-2
IIoT Routers
Ordering Information
Product Port Combination Interface RF
Region
Operating 10/100/1000 RS-232 DO Power
Model Name RS-485 DI Band
Temperature Base-T (Relay) Input
European Union,
DVW-W01I2-E1-EU -10℃ to 60℃ 1 1 1 1 1 2 EU Australia, New
Zealand
NOTE: For available countries for purchase, please contact your regional sales or distributors.
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48 VDC Industrial Power Supply
87
Industry
DVW-ANTRM8N-B3 Series
2.4 & 5GHz Dual-band Omni-directional
5.5 & 8dBi High-gain Antennas
Ethernet Switches
► 8dBi high-gain antenna to enhance wireless access performance
► Powerful magnetic base with 3 meters extended cable, RP-SMA (male)
connector
► IP65 weather proof with UV resistant design, suitable for all weather conditions
► Easy installation for indoor or outdoor environments
Specifications
ANTENNA CHARACTERISTICS
IIoT Routers
N-type (female) for antenna Height: IP Protection: • -40℃ to 85℃ (-40˚F to 185˚F)
Low-Loss Cable Length: • 44.6mm • IP65
• 3 meters Radome Material: Ambient Relative Humidity
Diameter:
Low-Loss Cable Type: • Fiberglass, UV resistant • 5% to 95% (non-condensing)
• 77.4mm
• CFD-200-NL Weight: Radome Color:
Low-Loss Cable Power Loss: • 56g • White
• ≦ 2.4dB (2.4GHz) Installation: Length:
• ≦ 3.2dB (5GHz) • Magnetic mount • 203mm
Radome Material: Diameter:
• Brass • 22.4mm
Weight:
• 86g
FIELD PATTERNS
H-PLANE for 2.4GHz E-PLANE for 2.4GHz H-PLANE for 5.8GHz E-PLANE for 5.8GHz
88
Industry
DVW-ANTRM7G-B3 Series
2.4GHz Omni-directional 7dBi High-gain Antennas
Ethernet Switches
Specifications
ANTENNA CHARACTERISTICS
IEEE 802.11 WLAN
Standard Compliance
Wireless Singal: Antenna Type: Polarization: Impedance:
• IEEE 802.11 b/g/n • Omni-directional • Vertical • 50Ω±5Ω
Typical Application: Typical Gain: V.S.W.R:
• Indoor / Outdoor • 7dBi • ≦ 2.0
Frequency: Beam Width: Power Handling:
• 2.4 to 2.5GHz • H: 360° / E: 20.7 • 10W
N-type (female) for antenna Height: IP Protection: • -40℃ to 85℃ (-40˚F to 185˚F)
Low-Loss Cable Length: • 44.6mm • IP65
• 3 meters Diameter: Radome Material: Ambient Relative Humidity
Low-Loss Cable Type: • 77.4mm • Fiberglass, UV resistant • 5% to 95% (non-condensing)
• CFD-200-NL Weight: Radome Color:
Low-Loss Cable Power Loss: • 56g • White
• ≦ 2.4dB Installation: Length:
Radome Material: • Magnetic mount • 450mm
• Brass Diameter:
• 20mm
Weight:
• 180g
FIELD PATTERNS
H-PLANE E-PLANE
89
Industry
IIoT Routers
DIACloud Routers
DX-3021L9 Series: Industrial 4G/WAN DIACloud Cloud Routers ................................................................................................................ 89
DX-3001H9 Series: Industrial 3G/WAN DIACloud Cloud Routers ................................................................................................................ 92
DX-2100 Series: Industrial 3G DIACloud Cloud Routers ............................................................................................................................. 95
DX-2300 Series: Industrial Ethernet DIACloud Cloud Routers .................................................................................................................... 98
Ethernet Switches
VPN Routers
DX-3001H9-V Series: Industrial 3G/WAN VPN Routers ........................................................................................................................... 101
90
Industry
DX-3021L9 Series
Industrial 4G/WAN DIACloud Cloud Routers
Ethernet Switches
6 0 0
4
► A data acquisition device connected to DIACloud cloud servers. Supports a two-way data collection channel
between the devices and the cloud
► Sets up a secure tunnel between the user and the remote device via DIACloud cloud servers, without the need
of additional VPN server
► Supports MODBUS TCP, MODBUS ASCII/RTU, Mitsubishi MC and Siemens ISO-on-TCP protocols
► Universal 4G LTE-FDD and LTE-TDD frequency bands, backward compatible with WCDMA/GSM/GPRS/EDGE
3G/2G networks
► LTE data transmission rate up to 150Mbps (downlink) / 50Mbps (uplink)
IEEE 802.11 WLAN
► Dual SIM dual standby technology, auto-switching between cellular operators without restarting devices
rd
► USB port could be acceptable 3 -party Wi-Fi USB adapter to add WLAN interface as Wi-Fi client (only Realtek
RTL8192EU driver supported )
► Automatic APN parameter matching and connection redial
► Connecting to internet through by cellular network or broadband interfaces. Come with indication the priority
of internet connectivity interfaces activated
► Various peripheral interfaces include RS-485, RS-232 and 4 LAN ports
► DI/DO built-in, users can trigger warning by specific events
► Support to upgrade device firmware and configure automatically via USB flash drive. Users can remotely
access the USB flash drive by FTP also
► Built-in RTC and supports NTP time synchronization over a network
IIoT Routers
► Firewall function: Stateful Packet Inspection (SPI), prevent denial of service (DoS) attacks, MAC address filter
and IP port filter
► Supports TCP/IP, UDP, ICMP, DHCP, HTTP, DNS and SSH protocols
► Scheduled jobs are available
► Device configurations import/export
► Network data flow statistics
► Networking failure diagnostics
► Device and PLC interlocking
► Custom alarm conditions with email alerts
Specifications
TECHNOLOGY
Standard Compliance
• GSM/GPRS/EDGE/ UMTS/DC-HSPA+/LTE
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
91
Industry
INTERFACE
4G 4G RF
GSM/GPRS/EDGE/UMTS/DC-HSPA+/LTE Frequency Band:
Antennas: • LTE FDD: B1, B2, B3, B4, B5, B7, B8, B12, B13, B18, B19,
• 1 2.5dBi omni-directional, SMA (male) connector, 3 meters B20, B25, B26, B28
cable with magnetic stand • LTE TDD: B38, B39, B40, B41
Fast Ethernet • UMTS: B1, B2, B4, B5, B6, B8, B19
RJ45 Ports: • GSM: 850, 900, 1800, 1900MHz
• WAN: 1 10/100Base-T(X), auto MDI/MDI-X, auto negotiation Data Transmission Rates
• LAN: 4 10/100Base-T(X), auto MDI/MDI-X, auto negotiation LTE:
Ethernet Switches
Serial Communication • LTE FDD Up link 50Mbps, down link 150Mbps
Serial Ports : • LTE TDD Up link 30Mbps, down link 130Mbps
• 1 RS-232 (5-pin terminal block), 1 RS-485 (3-pin terminal UMTS:
• DC-HSDPA Down link 42Mbps
block), 15KV isolation protection
• HSUPA Up link 5.76Mbps
Baud Rate:
• WCDMA Down link 384Kbps, up link 384Kbps
• 2400bps to 115200bps
GSM:
Data Bits:
• EDGE Up link 236.8Kbps, down link 296Kbps
• 7, 8
• GPRS Up link 85.6Kbps, down link 107Kbps
Parity:
RF Output Power:
• None, Even, Odd
• Class 4 (33dBm±2dB) @ GSM850
Stop Bits:
• Class 4 (33dBm±2dB) @ EGSM900
• 1, 2
• Class 1 (30dBm±2dB) @ DCS1800
Flow Control:
• Class 1 (30dBm±2dB) @ PCS1900
• RTS/CTS(RS-232 only), XON/XOFF
• Class E2 (27dBm±3dB) @ GSM850 8-PSK
IIoT Routers
• 0~+5V is OFF • -93.3dBm (10M) @ LTE B13
• +11V~30V is ON • -96.3dBm (10M) @ LTE B18
• -96.3dBm (10M) @ LTE B19
• Max. input current 6mA
• -93.3dBm (10M) @ LTE B20
Alarm Contacts (DO) • -92.8dBm (10M) @ LTE B25
• 2 relay outputs • -93.8dBm (10M) @ LTE B26
• Carry current 1A@24VDC • -94.8dBm (10M) @ LTE B28
SIM Card • -96.3dBm (10M) @ LTE B38
• Number of SIMs: 2, SIM 25mm x 15mm • -96.3dBm (10M) @ LTE B39
• SIM Control: 1.8V/3V • -96.3dBm (10M) @ LTE B40
Reset Button • -94.3dBm (10M) @ LTE B41
• WCDMA B1: -106.7dBm
• 1 set
• WCDMA B2: -104.7dBm
• WCDMA B4: -106.7dBm
• WCDMA B5: -104.7dBm
• WCDMA B6: -106.7dBm
• WCDMA B8: -103.7dBm
• WCDMA B19: -106.7dBm
• GSM850: -102dBm
• GSM900: -102dBm
• DCS1800: -102dBm
• PCS1900: -102dBm
92
Industry
Configuration
• Web Browser, DIACom, Android/iOS App
APPROVALS
Safety Environmental Type Tests
• UL 61010 Cold Temperature:
• IEC 62368-1 • IEC 60068-2-1
EMI Dry Heat:
• FCC 47 CFR Part 15 Subpart B Class A, IEC 61000-6-4, • IEC 60068-2-2
Humidity:
EN 55032, EN 55011, EN 301 489-1/52
• IEC 60068-2-30
EMS Shock:
(EN 301 489-1/52, IEC 61000-6-2, EN 55024) • IEC 60255-21-2
• IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, Freefall:
IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8 • IEC 60068-2-32
IIoT Routers
RF Vibration:
• EN 50385 • IEC 60068-2-6
• EN 301 511 Hi-Pot:
• EN 301 908-1 • 1.5KV
• NCC
• RCM
Ordering Information
Product Port Combination Interface RF
Region
Operating 10/100 DO Power
Model Name RS-232 RS-485 DI Band
Temperature Base-T(X) (Relay) Input
NOTE. For available countries for purchase, please contact your regional sales or distributors.
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48 VDC Industrial Power Supply
93
Industry
DX-3001H9 Series
Industrial 3G/WAN DIACloud Cloud Routers
Ethernet Switches
► A data acquisition device connected to cloud servers.
Supports a two-way data collection channel between the
device and the cloud
► Supports MODBUS TCP and MODBUS ASCII/RTU protocols
► Using UMTS/HSPA+ 3G technology, supports a wide
range of bands (850 / 800, 900, AWS1700, 1900, 2100 MHz). ► Network data flow statistics
Downward compatible with GSM/GPRS/EDGE 2G network ► Device and PLC interlocking
► Dual SIM redundancy design : seamless switch between ► Networking failure diagnostics
IIoT Routers
► Built-in RTC and supports NTP time synchronization over a
network
► Supports TCP/IP, UDP, ICMP, DHCP, HTTP, DNS and SSH
protocols
► Device configurations import/export
Specifications
TECHNOLOGY
Standard Compliance
• GSM/GPRS/EDGE/UMTS/HSPA+
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
94
Industry
Specifications
INTERFACE
3G 3G RF
GSM/GPRS/EDGE/UMTS/HSPA+ Frequency Band:
Antennas: • UMTS/HSPA+: 800/850, 900, AWS1700, 1900, 2100 MHz
• 1 2.5dBi omni-directional, SMA (male) connector, 3 meters • GSM/GPRS/EDGE: 850, 900, 1800, 1900 MHz
cable with magnetic stand Data Transmission Rates
Ethernet Switches
SIM Slot
• Number of SIMs: 2, Mini-SIM (25mm x 15mm)
• SIM Operating Voltage: 1.8V/3V
SD Socket
• SDHC(32mm x 24mm x 2.1mm), up to 32GB
Reset Button
• 1 set
95
Industry
PHYSICAL ENVIRONMENTAL LIMITS
Housing Operating Temperature
• IP30 metal case • -20ºC to 70ºC (-4ºF to 158ºF)
Dimensions Storage Temperature
• 145.3 mm (H) x 45 mm (W) x 112.3 mm (D) • -40ºC to 85ºC (-40ºF to 185ºF)
Weight Ambient Relative Humidity
Ethernet Switches
• 372g • 5% to 95% (non-condensing)
Installation
• Industrial DIN-Rail and Wall mounting
APPROVALS
Safety Environmental Type Tests
• UL 60950-1 Cold Temperature:
• IEC 60950-1 • IEC 60068-2-1
EMI Dry Heat:
• FCC 47 CFR Part 15 Subpart B Class B • IEC 60068-2-2
Humidity:
• EN 55022
Ordering Information
IIoT Routers
Product Port Combination Interface
Region
Operating 10/100 DO
Model Name RS-232 RS-485 DI Power Input
Temperature Base-T(X) (Relay)
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48 VDC Industrial Power Supply
96
Industry
DX-2100 Series
Industrial 3G DIACloud Cloud Routers
Ethernet Switches
Specifications
TECHNOLOGY
Standard Compliance
• GSM/GPRS/EDGE/UMTS/HSPA+
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
INTERFACE
3G
GSM/GPRS/EDGE/UMTS/HSPA+ Antennas:
• 1 2.5dBi omni-directional, SMA(male) connector, 3 meters cable with magnetic stand
97
Industry
INTERFACE
Fast Ethernet 3G RF
RJ45 Ports: Frequency Band:
• 1 10/100Base-T(X), auto MDI/MDI-X, auto negotiation • UMTS/HSPA+: 800/850, 900, AWS1700, 1900, 2100 MHz
Serial Communication • UMTS/HSPA+ (CN model): 900, 2100 MHz
Serial Ports : • GSM/GPRS/EDGE: 850, 900, 1800, 1900 MHz
• 1 RS-232(DB9 male), 1 RS-485(DB9 female), 15KV isolation Data Transmission Rates
protection HSPA+:
Baud Rate: • Up link 5.76 Mbps
• 2400bps to 115200bps • Down link 21.6 Mbps
Ethernet Switches
Data Bits: UMTS:
• 7, 8 • Up link 384 kbps
Parity: • Down link 384 kbps
• None, Even, Odd EDGE:
Stop Bits: • Up link 236.8 kbps
• 1, 2 • Down link 296 kbps
Flow Control: GPRS:
• RTS/CTS (RS-232 only), XON/XOFF • Up link 85.6 kbps
RS-232: • Down link 85.6 kbps
• TxD, RxD, RTS, CTS, GND RF Output Power:
RS-485 • Class 4 (2 W, 33 dBm) @GSM 850 / 900
• D+, D-, GND • Class 1 (1 W, 30 dBm) @GSM 1800 / 1900
LEDs • Class 3 (0.25 W,24 dBm) @UMTS
Device: • Class E2 (0.5 W,27 dBm) @EDGE 850 / 900
• PWR, SD, Ready, 3G, Signal Strength • Class E2 (0.4 W,26 dBm) @EDGE 1800 / 1900
IIoT Routers
• DIACloud • -108 dBm @ DCS1800 / PCS1900 MHz
Software
SSH, DNS, HTTP, TFTP, DHCP Server/Client, Telnet, Syslog,
NTP, MODBUS TCP, MODBUS ASCII/RTU, MELSEC POWER REQUIREMENTS
Communication
Input Voltage
Security • 12 to 48VDC, 3 pin terminal block input
• MAC/IP/URL filtering, SSH, SPI, Prevent denial of service
(DoS) attacks, Port triggering, Port mapping Input Current
• Max 1A
Virtual COM Drivers Overload Current Protection
• Windows XP, Windows Vista (32/64 bits),
• Present, Max. Input current 1.5A
Windows 7 (32/64 bits)
Reverse Polarity Protection
Configuration • NOT Present
• Web Browser, DIACom, Android/iOS App
98
Industry
APPROVALS
Safety Environmental Type Tests
• UL 60950-1, EN 60950-1 (DX-2100RW-WW certified) Cold Temperature:
EMI • IEC 60068-2-1
• FCC 47 CFR Part 15 Subpart B Class A Dry Heat:
• IEC 60068-2-2
• EN 55022 (DX-2100RW-WW certified)
Humidity:
• EN 301 489-1/7/24 (DX-2100RW-WW certified) • IEC 60068-2-30
EMS Shock:
(EN 301 489-1/7/24, EN 55024) • IEC 60255-21-2
Ethernet Switches
Ordering Information
Product Port Combination Interface
Region
IEEE 802.11 WLAN
Operating 10/100 DO
Model Name RS-232 RS-485 DI Power Input
Temperature Base-T(X) (Relay)
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48 VDC Industrial Power Supply
IIoT Routers
99
Industry
DX-2300 Series
Industrial Ethernet DIACloud Cloud Routers
Ethernet Switches
► Data acquisition device connected to cloud servers. Supports
a two-way data collection channel between the device and
the cloud
► Sets up a secure tunnel between the user and the remote
device via the cloud server, without the need of additional ► Device configurations import /export
VPN servers ► Network data flow statistics
► Supports MODBUS TCP, MODBUS ASCII/RTU and MC ► Networking failure diagnostics
protocols ► Device and PLC interlocking
IIoT Routers
► Supports TCP/IP, UDP, ICMP, DHCP, HTTP, DNS and SSH
protocols
► Scheduled jobs are available
Specifications
TECHNOLOGY
Standard Compliance
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
INTERFACE
Fast Ethernet
RJ45 Ports:
• WAN: 1 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
• LAN: 4 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
100
Industry
Specifications
INTERFACE MANAGEMENT
Cloud Service
Serial Communication
• DIACloud
Serial Ports :
• 1 RS-232(DB9 male), 1 RS-485 (Terminal block), 15KV isolation Software
protection • SSH, DNS, HTTP, TFTP, DHCP Server/Client, Telnet, Syslog, NTP,
Baud Rate: MODBUS TCP, MODBUS ASCII/RTU, MELSEC Communication
Ethernet Switches
ENVIRONMENTAL LIMITS
Operating Temperature
• -20ºC to 70ºC (-4ºF to 158ºF)
Storage Temperature
• -40ºC to 85ºC (-40ºF to 185ºF)
Ambient Relative Humidity
• 5% to 95% (non-condensing)
101
Industry
APPROVALS
Safety Environmental Type Tests
• UL 60950-1, EN 60950-1 Cold Temperature
EMI • IEC 60068-2-1
• FCC 47 CFR Part 15 Subpart B Class A Dry Heat:
• IEC 60068-2-2
• EN 55022
Ethernet Switches
Humidity:
EMS (EN 55024) • IEC 60068-2-30
• IEC 61000-4-2, IEC 61000-4-3, Shock:
IEC 61000-4-4, IEC 61000-4-5, • IEC 60255-21-2
IEC 61000-4-6, IEC 61000-4-8 Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
Ordering Information
Optional Products
IIoT Routers
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48 VDC Industrial Power Supply
102
Industry
DX-3001H9-V Series
Industrial 3G/WAN VPN Routers
Ethernet Switches
Specifications
TECHNOLOGY
Standard Compliance
• GSM/GPRS/EDGE/UMTS/HSPA+
• IEEE 802.3 10Base-T
• IEEE 802.3u 100Base-T(X)
INTERFACE
3G
GSM/GPRS/EDGE/UMTS/HSPA+ Antennas:
• 1 2.5dBi omni-directional, SMA (male) connector, 3 meters cable with magnetic stand
103
Industry
Specifications
INTERFACE
Fast Ethernet 3G RF
RJ45 Ports: Frequency Band:
• WAN: 1 10/100Base-T(X), auto MDI/MDI-X, auto negotiation • UMTS/HSPA+: 800/850, 900, AWS1700, 1900, 2100 MHz
• LAN: 4 10/100Base-T(X), auto MDI/MDI-X, auto negotiation • GSM/GPRS/EDGE: 850, 900, 1800, 1900 MHz
Serial Communication Data Transmission Rates
Ethernet Switches
Serial Ports : HSPA+:
• 1 RS-232 (5-pin Terminal block), 1 RS-485 (3-pin Terminal • Up link 5.76 Mbps
block), 15KV isolation protection • Down link 21.6 Mbps
UMTS:
Baud Rate:
• Up link 384 kbps
• 2400bps to 115200bps
• Down link 384 kbps
Data Bits:
EDGE:
• 7, 8
• Up link 236.8 kbps
Parity:
• Down link 296 kbps
• None, Even, Odd
Stop Bits: GPRS:
• 1, 2 • Up link 85.6 kbps
Flow Control: • Down link 85.6 kbps
• RTS/CTS (RS-232 only), XON/XOFF RF Output Power:
RS-232: • Class 4 (2 W, 33 dBm) @GSM 850 / 900
• Class 1 (1 W, 30 dBm) @GSM 1800 / 1900
IIoT Routers
Reset Button
• 1 set
104
Industry
APPROVALS
Safety Environmental Type Tests
• UL 60950-1 Cold Temperature:
• IEC 60950-1 • IEC 60068-2-1
EMI Dry Heat:
• FCC 47 CFR Part 15 Subpart B Class B • IEC 60068-2-2
Humidity:
• EN 55022
• IEC 60068-2-30
• EN 55032 Shock:
• EN 301 489-1/7/24 • IEC 60255-21-2
Ethernet Switches
EMS Freefall:
(EN 301 489-1/7/24, EN 55024) • IEC 60068-2-32
• IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, Vibration:
IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8 • IEC 60068-2-6
Hi-Pot:
RF • 1.5KV
• EN 301 511, EN 301 908-1
• FCC Part 22H, 24E, 27
Ordering Information
Product Port Combination Interface
IEEE 802.11 WLAN
Region
Operating 10/100 DO
Model Name RS-232 RS-485 DI Power Input
Temperature Base-T(X) (Relay)
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
CliQII/PMC Series: 48 VDC Industrial Power Supply
IIoT Routers
105
106
Global Operations
Northern Europe
A Finland
B Estonia
C Latvia
D Lithuania
Netherlands Germany E Sweden
Edmonton Canada Amsterdam Sust F Denmark
Eindhoven G Iceland
A
Zurich E
France United
Kingdom F
B
C Russia
Sonoma Paris
Fremont
USA Ireland N
D Belarus Moscow
Tashkent
Kitchener Belgium H I
Spain
Los Angeles O
Chicago P Moldavia Ka
France J L
Boston Barcelona K M Romania Georgia
San Diego Kosovo Serbia
Plano Madrid Spain
Italy
Bulgaria Turkey Uzbe
Raleigh Istanbul
Mexico Italy Albania
Malta
Cyprus
Greece Lebanon
Armenia
Milan Morocco
Jordan
Rome Tunisia Israel
Nuevo Leon Libya
Jalisco Iraq
Queretaro
Mexico City
R. Dominicana Central Europe
H Netherlands Egypt Qatar
UAE
Brit.Virgin Is. I Germany Cairo Saudi Dubai
Guatemala Puebla
J Czech
Arabia Oman
El Salvador
Nicaragua K Austria
Costa Rica L Slovenia
Senegal
Panama Nigeria Ethiopia
M Croatia
Togo
N Poland
Benin
O Hungary
Colombia P Switzerland
Congo
Kenya
Ecuador
Tanzania
Bolivia
Sao Paulo
Bela Vista South Africa
Paraná
Paraguay
Santa Catarina
Chile
Uruguay
Argentina
107
Amsterdam, the Netherlands Research Triangle Park, U.S.A.
Korea
Seoul
Daegu
Japan
Tokyo
azakhstan
1
Osaka Dalian
ekistan
2 Japan Shanghai
Wujiang (Wujiang Plant 3 & Wujiang Motor Plant )
Tadzhikistan 23 3
26
4
Korea
25 19
7
5
6 8 Dongguan
9
Taoyuan (Technology Center & Plant 1)
20 27
10
21
11 12
18
24
22 14 13 Taiwan Zhong li
17 16 15
Taichung
India Thailand Tainan
Chandigarh Vietnam
Gurgaon Philippines
Kolkata
Sri Lanka
Malaysia
Ahmedabad Singapore China
Heilongjiang 1 8 Shandong 11 Anhui 15 Guangdong 20 Henan 24 Guizhou
Mumbai
Pune
Indonesia Harbin Qingdao Hefei Shenzhen Zhengzhou Guiyang
Jinan Guangzhou Luoyang
Hyderabad 2 Jilin 12 Zhejiang 25 Gansu
Yantai Foshan Changyuan
Changchun Hangzhou Lanzhou
Bangalore
9 Jiangsu Ninggbo 16 Guangxi Hubei
Chennai 3 Liaoning 21
26 Xinjiang
Yangzhou Wenzhou Nanning Wuhan
Coimbatore Shenyang Urumqi
Nanjing Jiaxing Guilin Xiangfan
Dalian
Visakhapatnam Australia Nantong Shaoxing Liuzhou 27 Anhui
Chhattisgarh Melbourne 4 Shanxi Changzhou 22 Hunan Wuhu
13 Fujian 17 Yunnan
Taiyuan Wuxi Changsha
Xiamen Kunming
Malaga Beijing Suzhou Hengyang
5 Fuzhou
Kunshan 18 Sichuan
Tianjin Quanzhou 23 Inner Mongolia
6 Xuzhou Chengdu
Baotou
7 Hebei 10 Shanghai 14 Jiangxi 19 Shaanxi
Shijiazhuang Jiading Nanchang Xian
Qinhuangdao Songjiang
Tangshan
108
WWW.KALATEC.COM.BR