You are on page 1of 3
DAIKIN PT. DAIKIN AIRCONDITIONING INDONESIA note jarak<50 meter intuk panjang kabel dibawah 50 meter dari panel AC (PAC) ke Outdoor unit NO] DESCRIPTION | MCB/FUSES | CABLE SIZE MASTER ‘CABLE SIZE SLAVE 1 ‘CABLE SIZE SLAVE 2 T[RXO6 [3 Phase, 20A_|4x4mm* + Grounding 2|RXQ8 3 Phase, 20 [4x4 mm? + Grounding 3|Rxa10 [3 Phase, 25A__[4 x6 mm? + Grounding a|rxar2 [3 Phase, 25A _|4x10 mm? + Grounding S|axai4 [3 Phase, 35A__|4x10 mm? + Grounding a|Rxaa6, [3 Phase, 35A [4x10 mm? + Grounding 7|Rxais 3 Phase, 35A__[#x10mm*+ Grounding [4x6 mm? + Grounding [x20 [3 Phase, SOA _[4x16mm*+Grounding [4x 10mm? + Grounding g|Rxa22 [3 Phase, SOA _[4x16mm?+Grounding [4x10 mm? + Grounding ‘iolRxaz4 [3 Phase, 60A _|4x16mm*+Grounding [4x 10mm? + Grounding 11]Rxa26 [3 Phase, 60A _|4x16mm*+Grounding [4x10 mm? + Grounding 12|Rxa28 [3 Phase, 60A _|4x16mm*+Grounding [4x10 mm? + Grounding 13|RX030 [3 Phase, 60A _|4x16mm*+Grounding [4x10 mm? + Grounding 14]Rx032 [3 Phase, 70A__|4xi6mm**Grounding [4x 10mm? + Grounding 15[Rx034 [3 Phase, 70A_|4x16mm*+ Grounding [4x 10mm? + Grounding _|4x6mm? + Grounding 16] RX036 [3 Phase, 80A__|4x25mm**Grounding [4x 16mm? + Grounding _ [4x10 mm + Grounding 17[Rx038 [3 Phase, 90A_|4x25mm* Grounding [4x 16mm? + Grounding |4x10 mm + Grounding 18[Rx040 [3 Phase, 90A_|4x25mm*+Grounding [4x 16mm? + Grounding _|4x10 mm*+ Grounding a9|Rxa42 [3 Phase, 100A_[4x25mm*+ Grounding [4x 16mm? + Grounding _ [4x10 mm* + Grounding 2o]axasa [3 Phase, 100A [4x25 mm>+Grounding [4x 16mm? + Grounding _ [4x10 mm*+ Grounding 2/RKO46 [3 Phase, 100A_[&x35mm*+ Grounding [4x 25mm? + Grounding _ [4x16 mm? + Grounding 22|RXO48 [3 Phase, 110A [4x35 mm? Grounding [4x 25mm? + Grounding _ [4x16 mm? + Grounding 23[RKO50 3 Phase, 110A [4x35 mm?+ Grounding _[4x25mm+ Grounding [4x16 mm? + Grounding 24[RKO52 3 Phase, 110A [4x50 mm?+ Grounding [4x35 mm*+ Grounding [4x25 mm? + Grounding 25[RKO54 [s Phase, 110A |4x50mm*+ Grounding [4x35 mm? + Grounding _|4x25mm* + Grounding 26|/RKO56 [3 Phase, 125A [4x50 mm*+ Grounding [4x35 mm? + Grounding _ [4x25 mm*+ Grounding 27|RKO58 [3 Phase, 125A [4x50 mm*+ Grounding [4x 35mm?+Grounding _|4x25mm*+ Grounding 28|RXQ60 [3 Phase, 150A _[4x50mm*+ Grounding _[4#x35mm?+ Grounding [4x25 mm+ Grounding PT. Daikin Airconditioning Indonesia Bees /é Site Engineer Project Sales foto : Mengare pra Bandar pew 4 AELL DAIKIN PT. DAIKIN AIRC: DIT! HNG INDONESIA note : Untuk panjang kabel diatas 50 meter dari panel AC (PAC) ke Outdoor unit jarak> 50 meter DESCRIPTION | _MCB/FURES Tras ErPhese, 208 [ora mm + Grounding 28 E Phose. 20a [x6 mm?+ Grounding 3fmx010 [5 Phese. 258 [10 mm + Grounding fp? Phase. 25A | 10 mm?+ Grounding s]exar4 [3 Phose, 35a [x16 mm+ Grounding Gfrnaié 3 Phase. 35a [16 mn? Grounding 7|RXQ18 3 Phase, 35A_|4x 16 mm? + Grounding |4x 10 mm? + Grounding 8/RXQ20 3 Phase, 50A__|4x 16 mm? + Grounding |4x 10 mm? + Grounding 3]tvaz2 ——]3Phese.50A [#16 mn?+ Grounding — [10 mm? + Grounding Tofxazs 3 Phase. 608 [4x25 mm Grounding [4x16 mm™+ Grounding 11}RXQ26 [3 Phase,60A__|4x25mm?+Grounding _|4x 16 mm? + Grounding 12028 3 Phase. 60A [4x25 mm? Grounding — [4x16 mm"+ Grounding 13|RXQ30_ [3 Phase, 60A_|4x25mm?+Grounding _|4x 16 mm?+ Grounding Ta)RxG32 [5 Phose, 70A [e425 mm™+ Grounding [x46 mm? Grounding 15|RXQ34 [3 Phase, 70A__[4x25mm?+Grounding _|4x 16 mm? + Grounding |4 x 10 mm? + Grounding 16|RXQ36_ [3 Phase, 80A__|4x25mm?+Grounding _|4 x 16 mm? + Grounding |4 x 10 mm? + Grounding 17|Rx038, [3 Phase, 90A__[4x35mm?+Grounding [4x 25mm*+ Grounding _ 4x16 mm* + Grounding 18/RXQ40_ [3 Phase, 90A_|4x35mm?+Grounding _|4 x 25 mm? + Grounding. |4 x 16 mm? + Grounding 19|RXQ42 [3 Phase, 100A_|4x35mm?+Grounding _|4x25mm?+Grounding _|4x 16 mm? + Grounding 20|mxQa4 3 Phase. 100A [x50 mim? + Grounding [#35 mm*+ Grounding [#25 mm* Grounding 21/RXQ46 |3 Phase, 100A_|4x50mm?+Grounding [4x35 mm?+Grounding [4x 25 mm? + Grounding 22)RXO48 |3 Phase, 110A_|4x50mm?+Grounding [4x35 mm?+Grounding _[4 x 25 mm? + Grounding 23|RXQ50 [3 Phase, 110A_|4x50mm?+Grounding _|4 x 35 mm? + Grounding |4 x 25 mm? + Grounding 2a] RKG52 [5 Pose. 1208[ex50 mm? + Grounding [435 mn? Grounding [25 mm? Grounding 25/RXQ54 [3 Phase, 110A_[4x50mm?+Grounding _|4x 35 mm? + Grounding |4 x 25 mm? + Grounding 26] RGSS [3 Phose. 125A o50 nm? Grounding [#35 mm’+ Grounding — [3x25 mm? rGrounding Z7faxas6 [5 Phase. 1758 [be50 mm™+ Grounding 435 mm™ + Grounding |e 25 mm + Grounding 28/RXQ60 [3 Phase, 150A |4x50mm?+Grounding [4x35 mm*+Grounding [4x 25 mm? + Grounding PT. Dakin Airconditioning Indonesia Kol -2r ig Site Engineer Project Sales Standard PLN, Ukuran Kabel Minimal vs Ampere 450 04530 TR 24 220VNYYINYM 3x25 mm 1.300 13100 TR 64 220 NYY INV 3.x 4mm? 3500 35 2800 TR 161 220 vv 3 x4 mt 5.500 55 4400 TR 251 220 NYYINYM 3x4 ma 220V NYVINYM 3 x 380V__NYV/NYFCBY Bee, Get, 52 3 LOR 380.V vey 3 PALER ae 24 208, o08R ieanvaeay

You might also like