Professional Documents
Culture Documents
This guide provides quick start instructions for an experienced installer to set up and operate the
Extron ISS 506 Integration Seamless Switchers, a family of seamless, scaling, video and stereo audio switchers.
9
C VID Y
LO-
PICTURE
DVI
OUT
RES
OUT
R-Y/ Y/ B-Y/ ADJUSTMENTS
R G B
PREVIEW
PROGRAM
100-240V
50/60 Hz
1 R/
R-Y
G/Y
VID
B/C
B-Y
H/HV V 3 R/
R-Y
G/Y
VID
B/C
B-Y
H/HV V 5 VID
/Y
6 VID SDI RGB/R-Y, Y, B-Y
Scan Converter SIZE
BRIGHT/
CONT
DETAIL
2A MAX
I R G B/ LAN
N O R-Y /Y B-Y RGB/R-Y, Y, B-Y RS232/422 COLOR/
2 4 U POSITION ZOOM
P RESET TINT
U T 3G/HD-SDI
T R/ B/C G/Y B/C B-Y P H V S
OUT
G/Y H/HV V R/ H/HV V R-Y YC
S R-Y VID B-Y R-Y VID B-Y /C U CONFIG
T
S
PROGRAM PREVIEW
3G/HD-SDI
L 1 R L 2 R L 3 R L 4 R L 5 R L 6 R L FIXED R L VARIABLE R L R
1 5 10 7 11 13 12 14
Connections
a
AC power connector h (RGB
Preview Output 15-pin HD connector
or component)
b (RGB,
Inputs 1 through 4 configurable BNC connectors
component, RGBcvS, S-video, or composite)
i Optional Program Output connector(s)
(DVI, scan converted low resolution, or 3G/HD-SDI ) †
a. Program outputs — Connect video devices to the 15-pin HD output female connector (shown at right) and
the BNC connectors (shown below).
b. If an optional program output board is installed DVI Video Program Output Configurations
(see the ISS 506 User Guide, available at
www.extron.com), connect a DVI-D (shown
at right), 3G/HD-SDI (shown below right), or R
R-Y
G
/Y
B/ R
R-Y
G
/Y
B/
B-Y B-Y
low resolution device (scan converted output),
3G/HD-SDI Video
shown below, to the board.
H V S H V S
Scan Converted Output Configurations RGBHV RGBS
Video Video
C VID Y C VID Y
RGsB and R G B/
R-Y/ Y/ B-Y/ R-Y/ Y/ B-Y/ R-Y /Y B-Y
R G B R G B Component
Component Video Composite Video Video
C VID Y
H V S
NOTE: The ISS outputs S-video and
R-Y/ Y/ B-Y/ composite video simultaneously.
R G B
S-Video
L
Sleeve Tip Ring
Tip Tip Sleeves
Sleeve
R
R
Ring
Do not tin the wires! Unbalanced Stereo Input Balanced Stereo Input NO GROUND HERE
Unbalanced Stereo Output Balanced Stereo Output
NOTE: The Variable Program audio output is adjustable CAUTION: For unbalanced audio, connect the
using the front panel Volume control. The other sleeves to the ground contact. DO
audio outputs are not adjustable. NOT connect the sleeves to the
negative (-) contacts).
2
ISS 506 • Setup Guide (Continued)
Step 6 — LAN (Ethernet) port Pins: Crossover Cable Straight-through Cable
12345678
End 1 End 2 End 1 End 2
If desired, connect a network WAN or LAN hub, a control system, Pin Wire color Wire color Pin Wire color Wire color
or computer to the Ethernet RJ-45 port. See the ISS 506 User 1 White-green White-orange 1 White-orange White-orange
Guide, available at www.extron.com. 2 Green Orange 2 Orange Orange
• Network connection — Wire as a patch cable. 3 White-orange White-green 3 White-green White-green
4 Blue Blue 4 Blue Blue
• Computer or control system connection — Wire the interface
5 White-blue White-blue 5 White-blue White-blue
cable as a crossover cable.
6 Orange Green 6 Green Green
NOTE: Defaults: 7 White-brown White-brown 7 White-brown White-brown
Insert Twisted 8 Brown Brown 8 Brown Brown
• RS-232 • 9600 baud Pair Wires T568A T568B T568B T568B
• IP: 192.168.254.254 • Subnet: 255.255.0.0
RJ-45 A cable wired as T568A at one end A cable wired the same at both ends is
• Gateway: 0.0.0.0 • DHCP off Connector and T568B at the other (Tx and Rx pairs called a "straight-through" cable, because
reversed) is a "crossover" cable. no pin/pair assignments are swapped.
See “Configure Ethernet and RS-232/RS-422 ports,” on
the next page, to change the settings.
Step 7 — Power
AC power connector — Plug in a Power Initializing
on Please Wait...
standard IEC power cord from a 100 to Default Display Cycle
240 VAC, 50 - 60 Hz power source into 2
Extron Integration sec. Prog #n {format} Prev #n {format}
this receptacle. 10 ISS 506 Vn.nn 2 SeamlessSwitcher n.nkHz n.nHz n.nkHz n.nHz
sec. sec.
2
Powering Up 2
sec. Output Rate
sec.
{resolution) @{rate}
Apply power by connecting the power cord to an AC source. The switcher performs a self-test
that displays the model name and the firmware version in the LCD screen. After approximately
2 seconds, the LCD screen reverts to its default display cycle, alternating between three displays:
two showing the selected program and preview inputs and their
Program Bus Transition Picture
rates, and the third showing the selected output rate. (Freeze/Input Selection/Logo) (Cut/Take) Adjustments LCD Volume
4 5 6 LOGO 1
/BLACK
LOGO 2
/BLACK
TRANSITION
CUT TAKE
PICTURE
ADJUSTMENTS
BRIGHT/
ADJUST VOLUME
4 5 6 LOGO 1
/BLACK
LOGO 2
/BLACK
WIPE PIP
POSITION
COLOR/
TINT
ZOOM MENU NEXT
ADJUST
DISSOLVE TITLE
CONFIG
Press and release the desired Program or Preview input selection ISS 506
Integration Seamless Switcher
button. The button lights and the selected input displays on the Program Bus Effects Menu Controls
program or preview monitor. (Freeze/Input Selection/Logo) (Wipe/PIP/Dissolve/Title)
1. For an effect to accompany the switch, press one of the Effects buttons.
Wipe — The image in the preview output “unrolls” over the top of the
program output using the duration and sub-effect. Soft Left Soft Curtain Out Hard Left Hard Curtain Out
Dissolve — The previous program output fades out and the image from
the preview output fades into the program output using the duration.
PIP — The image in the preview output appears in the program output as Soft Up Soft Square In Hard Up Hard Square In
a picture-in-picture window using the duration and sub-effect.
Title — The image in the preview output appears on top of the program
output as a title.
2. Press either the Cut or the Take button. Soft Down Soft Square Out Hard Down Hard Square Out