Professional Documents
Culture Documents
Mobile c-arm
www.sternmed.de
Xenox C400
Mobile c-arm
2 © SternMed
FEATURES
© SternMed 3
APPLICATIONS AVAILABLE MODELS
• Vascular surgery
• Endovascular applications
• Urology procedures
• Catheter procedures
• Neuroradiology
• General surgery
• Traumatology
• Orthopaedic
• Interventional radiology
Display station
The monitor trolley is equipped with a 27” High Resolution
main monitor for work and memory images displaying and
a dedicated 21,5” Touch Screen monitor for the operator.
4 © SternMed
C-arm lateral rotation ± 180° USER’S INTERFACE
Easy and practical 10” Touch Screen control console, installed
directly on the unit, for all the operative parameters and mes-
sages of possible faults.
Color-coded axes and brake handles make orientation Remote control panel, 3 joysticks (only with
intuitive and easy E-Motion option)
The operator can work outside the sterile field thanks to the
monitors’ rotation.
© SternMed 5
OPERATING MODES AND FUNCTIONALITY
6 © SternMed
EXCELLENT CLINICAL IMAGES
© SternMed 7
TECHNICAL SPECIFICATIONS
RADIOLOGICAL FEATURES
Generator power in DC current 30 kW Single phase voltage 220 Vac (with Dual Power) (*)
Generator operating frequency 200 kHz
KV range 40 - 125 kV (Pulsed and radiography modality) (40 - 120 kV)
with 0,3 - 0,6 focal spot x-ray tube)
Manual: 0.5 - 8 mA
Ma Range With Continuous Fluoroscopy step of 0,1 mA
(Memory Acquisition To 30 Fps) Automatic I Level: 0.5 - 8 mA step of 0,1 mA
Automatic II Level: 0.5 - 5,5 mA
Automatic III Level: 0.5 - 6,6 mA
High Dose Pulsed Fluoroscopy Manual: 0.5 - 3,6 mA step of 0,1 mA
Maximum Current (Rate 1,3,6,12,15, Manual: 10 - 50 mA step of 1 mA - 270°
25,25 – Depends From Memory Automatic I Level: 10 - 50 mA“S” 3,5 kW
Configuration) Automatic II Level: 15 mA fixed
Automatic III Level: 10 - 25 mA
Automatic IV Level: 10 fixed mA
Fluorography Ma Range (Rate 25 - 250 mA (25 - 150 mA with 0,3 - 0,6 focal spot x-ray tube),
1,3,6,12,15,25 – Depends From Memory
Digital Radiography Maximum Current 250 mA (150 mA with 0,3-0,6 focal spot x-ray tube)
Radiography With Cassettes Ma Range 25 - 300 mA* (25 ÷ 200 mA** with 0,3-0,6 focal spot x-ray tube
Radiography Exposure Time 0,02 - 3 S
Min And Max Mas 0,5 - 250 mAs
Total Filtration ≥ 2.7 mm Al / 75kV
*30kW at 100kV 300mA 100mSec
© SternMed 8
TECHNICAL SPECIFICATIONS
Xenox C400 | SternMed Mobile Digital C-arm with FPD
© SternMed 9
SternMed GmbH
Schubertstrasse 31 © SternMed GmbH – All rights reserved.
88214 Ravensburg - Germany
SternMed GmbH reserves the right to make
Tel: +49 751 35 978 0 changes in specifications and features shown
Fax: +49 751 35 978 105 herein, or discontinue the product described
at any time without notice or obligation. Con-
email@sternmed.de tact your SternMed Representative for the
most current information.
Rev. V. 1.0