You are on page 1of 32
SECTION-IX AUTO CABLES [ PRODUCTS } { FLRYK Page No.: 263 Page No.: 273 {rurva { Thin wall Multicore Cables | Page No.: 255 | Page No.: 264 _ Page No.: 274-277 fm {rurye { Tinned Copper Cables } Page No. 256 “Page No.: 265 \ Page No.: 278-279 (ruuy PVC Battery Cable | | Page No.: 266 _ Page No.: 280 ) rurvw ) (Pvc Battery Cable | __ Page No.: 267 - 268 Page No.: 280 ) { ruaay } {_ Elastomeric Battery Cable Page No.: 269 Page No.: 281 Truvy ) (‘Copper Earthing Braids | “Page No.: 270 { Fur13v “Page No. 261 Page No. 271 FLYK { FLRY n x (Twisted Cables) (Page No 262 [Page No.:272 PVC Ignition Cable | Page No.: 282 SXL REACH | RoHS | COC cote ‘SXL - Special Purpose Cross-Linked Polyolefin insulated Cable Application These are extra thick walled insulated cables used in automotive electric circuits of motoreycles and off-road vehicles, ‘Standard In accordance to SAEJ1128, ‘Temperature Range (3000 Hrs) -40°0 to #1250 Cable Construction Soft annealed electrolytic copper ASTM B3 Cross-linked polyethylene (PE) with heat resistant properties according to SAE J1128 Packing Available in 100 mtrs. coil. Longer length available in spools or wooden drums, ‘Special Properties High temperature resistant and flame retardant Provides higher reliability in heat resistance than conventional general wires due to emission bridging Cable Design Parameters 7 026 7 sz 20 19 019, 1 16 026 8 19 0.23 16 19 029 uw 19 0.36 2 19 0s, 10 19 058 10 108 025 8 19 ore 8 50 045, 6 a7 or 6 133 0.36 “Net aper Sa 128 264 | RR KABEL 6XL HJ CoPCU ia ont GXL - General Purpose Cross-Linked Polyolefin insulated Cable Application These are standard wall insulated cables for general purpose application in automotive electric circuits of motorcycles and off-road vehicles Standard In accordance to SAE J1128 ‘Temperature Range (3000 Hrs) -40°C to +125°C Cable Construction Soft annealed electrolytic copper ASTM BS Cross-linked polyethylene (PE) with heat resistant properties according to SAE J1128 Packing Available in 100 mtrs. col. Longer length available in spools or wooden deums. Special Properties High temperature resistant and flame retardant Provides higher reliability in heat resistance than conventional general wices due to emission bridging Cable Design Parameters vie Nominal insulation a some ad SR, atigete URES tiie % » oss 20 on ro : ” on 380 ons ss Notas pr SAE J28 BR KABE TXL REACH | RoHS | Coca ee ‘TXL - Thin Wall Cross-Linked Polyolefin insulated Cable Application These are extra thin walled insulated cables used for automotive lightings, signals and instrument panel circuits Standard In accordance to SAE J1128 ‘Temperature Range (3000 Hrs) -40°C to #1250 Cable Construction Soft annealed electrolytic copper ASTM B3 Cross-linked polyethylene (PE) with heat resistant properties according to SAE J1128 Packing Available in 100 mtrs. coil. Longer length available in spools or wooden drums, ‘Special Properties High temperature resistant and flame retardant Provides higher reliability in heat resistance than conventional general wires due to emission bridging Cable Design Parameters 2 2 026 o78 oa 16 20 Es) 032 0.96 04 18 20 Ey) on 095 oa 18 6 18 0.26 1.22 o4 20 8 18 023 12 oa 20 6 16 029 145; 04 23 u 4 0.36 1.80 04 26 n 2 04s 2.25 046 32 10 10 058 298 ost 40 10 10 0.25 290 081 40 a a 072 3.60 056 48 a a 04s 367 0.86 48 6 6 ore 5.10 070 65 6 e 0.36 4.80 0.70 62 “Nota SHE 128 266 | RR KABEL ACH | ROHS 1 CE AV Tem ‘AV - Standard wall PVC insulation ‘Application These are standard wall auto cables for ideal use in automotives by harness manufacturers, Standard In accordance to JASO D 611, JASO D 618, JIS C3406 ‘Temperature Range (3000 Hrs) -40°C to +80°C Cable Construction Soft annealed electrolytic copper Cu-ETP1 according to D 609-80, bare conductor construction according to JASO 0 611 PYC insulation, material accordingly to JASO D 611 Packing Available in 100 mis. Longer length available in spools. Cable Design Parameters 05 7 032 19 327 06 24 -02 100 0.86 n 0.2 12 208 06 26 -02 130 1.25 16 032 15 143 06 29 -02 170 2 6 032 13 881 06 34 08 260 3 a 032 24 559 o7 a -03 400 5 65 032 30 352 08 43 -03 620 8 50 0.45 37 232 08 58 -03 920 10 e 0.45 45 184 10 69 “04 1200 18 84 0.45 48 1.38 WW 14 “04 1600 ost 20 018 10 367 06 24 “02 90 ost 30 018 12 244 06 26 -02 120 1.25F 50 018 15 var 06 29 “02 180 oF a7 026 18 95 06 34 “04 250 st 6 0.26 24 516 o7 a -03 400 RRKABEL | 257 AVS ! Cocca ee AVS - Thin Wall PVC Insul Application ‘These are thin wall auto cables ideal for use in automotives. Standard JASOD 611, JASOD 618 ‘Temperature Range (3000 Hrs) 40°C to +80°C. Cable Construction Soft annealed electrolytic copper Cu-ETP) according to 0 609-90, bare conductor construction according to JASO D 611 PVC insulation, material accordingly to JASO D 611 Packing Availabe in 100 mtrs. Longer length availabe in spools, Cable Design Parameters Max 0c Nom. bh net, Max cone Se Ore) gp eit (om) Diameter) fn | Tikes (rm) Max, Tolan 03 7 0.26 os 502 050 19 01 6 05 7 0.32 10 327 0.50 aa “01 8 os n 0.32 12 208 0.50 23 01 2 1.25 16 0.32 18 143 0.50 26 01 16 2 26 0.32 19 3a 0.80 an “02 2 3 a 0.32 24 559 0.60 38 -02 39 5 85 0.32 30 352 070 45 -02 60 oat 6 018 os 489 0.50 19 01 6 ost 20 018 10 367 0.50 21 01 8 os 30 018 12 24 0.50 23 01 n 125K 50 018 18 147 0.50 26 01 W 2 a 0.26 18 95 0.50 an 04 2 AVSS hat NSU Cocca ont AVSS - Ultra Thin Wall PVC insulation Application These are ultra thin wall auto cables ideal for use in automotives, Standard 4JASO D611, JASOD 618, ‘Temperature Range (3000 Hrs) -40°C to +80°C Cable Construction Soft annealed electrolytic copper Cu-ETP1 according to JIS C'3102, bare conductor construction according to JASO D 611 PVG, insulation material accordingly to JASO D 611 Packing Available in 100 mtrs. Longer length available in spools Cable Design Parameters = soon, ses SL oo (a (2m) parm) Rennie, TO) yan BR KABE FLY REACH | ROHS | C Coca nce Application ‘These are standard wall auto cables ideal for use in motor wirings of fans and sensor applications in automobiles, Standard Based on 1S0 6722-1 ‘Temperature Range (3000 Hrs) 40°C to #105" Cable Construction Soft annealed electrolytic copper Cu-ETP! according to DIN EN 13602, bare conductor construction according to ISO 6722-1 ‘Soft PVC insulation with properties according to ISO 6722-1, Class B Special Properties Conductor with cross-section > 6 mm? are also suitable as battery cable Packing Available in 100 mtrs. Longer length a lable in spools or wooden drums. Cable Design Parameters 075 24 021 021 287 06 20 25 1 2 021 021 185 06 24 27 1s 30 026 0.26 127 a6 27 30 2 40 026 0.26 9.42 06 29 33 25 50 026 026 76 07 33 36 3 60 026 0.26 6158 07 35 41 4 56 ost ost an os 40 44 6 a4 031 oat 314 08 46 50 0 80 oa) 041 182 190 60 65 16 126 oat ot 16 19 70 83 25 196 oa oat a7as 13 ar 104, 35 276 oat ot ser 13 100 ne 50 400 oa oat 0368 15 na 135 70 560 oat ot 0.259 15 40 185 95 740. oat oat 0195 16 154 180 120 960 oat oat 0183 16 187 197 260 | RR KABEL FLYW ACH | RoHS 1 2 Application These are auto cables ideal for use in automotives with hot pressure resistance Standard In accordance to IS0 6722-1 Temperature Range (3000 Hrs) -40°C to #125°C Cable Construction Soft annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare conductor construction according to ISO 6722-1 Soft PVC insulation with properties according to IS0 6722-1, Class C Packing ‘Available in 100 mtrs, Longer length available in spools or wooden drums. Special Properties Hot pressure resistance test at 120°C. Suitable for applications inside the engine compartment, Cable Design Parameters No.of ‘Overl bameter (rm) ‘Stands Mex, Tolerance 6 23 “03 80 Py 25 “03 10 1 32 27 -03 140 125 6 295 “055 140 18 30 3.0 “03 190 2 28 33 “03 250 25 50 36 “03 310 3 60 al “03 3T0 4 56 ost 278 an oa 44 “04 470 5 65 a3 ar 394 os 49 “04 580 6 84 ot 33 314 08 5.0 “0.4 680 e 50 048 43 238 os 59 “08 380 10 80 oat 45 182 10 65 “05 mo ¥ 96 ont 54 152 10 74 “08 1420 16 126 on 63 116 10 83 06 179.0 20° 182 oat 69 0.955 Ww aa “10 2180 Ey 196 oat 78 0.743 13 104 “10 780 “Sis tom JS C06 “Not apr 1906722 RR KABEL | 26 FLYK occa ten Application ‘These are standard wall auto cables with cold resistant properties and increased flexibility Standard In accordance to 1S0 6722-1 Temperature Range (3000 Hrs) “50°C to #105" Cable Construction Soft annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare conductor construction according to ISO 6722-1 Soft PVC insulation cold-resistant Packing ‘Available in 100 mis. coils. Longer length available in spools ‘Special Properties Cold bending test ace. to ISO 6722-1 at -60°C ‘Short-term and long term ageing according to ISO 6722-1, Class B. Cable Design Parameters od 8 a6 u a7 06 23 03 a0 075 a2 016 13 251 06 28 “03 n0 10 57 016 18 188 06 ar “03 150) 1s 84 016 18 127 06 3 -03 200 25 140 a6 23a 7.54 a7 a6 “04 20 262 | RR KABEL FLRYK Mnete tT CoECU lm eee Application ‘These are thin wall auto cables with cold resistant properties Standard In accordance to 1S0 6722-1 Temperature Range (3000 Hrs) “50°C to #1050 Cable Construction Soft annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare conductor construction according to ISO 6722-1 Soft PVG insulation cold-resistant Special Properties Cold bending test acc. to 1S0 6722-1 at -50°C. ‘Short-term and long term ageing according to SO 6722-1, Class B Packing Available in 100 mtrs. Longer length available in spools, Cable Design Parameters Moe 0c Nom. Ma, Nominal Wio.of Mae Stand Condit ‘pros. eight ro: Section cenditor Aneuition ‘Sands Diameter im) Resistance ‘alka ‘com Diameter (em) iy) TERS my 08 6 021 10 a7. 0.28 16 02 60 10 32 021 14 185 0.30 24 -02 120 18 30 026 7 127 0.30 24 “03 160 25 50 0.26 21 76 035 30 03 300 FLRY A REACH | RoHS | CE occa tae Application These are thin walled cables ideal for use in automotives where its reduced insulation thickness and higher temperature withstanding properties serves its application in complex wiring harnesses. Standard Inaccordance with ISO 6722 Voltage Rating 60V 00; 25 VAC. (Suitable for 12 Volts and 24 Volts systems) Temperature Range (3000 Hrs) -40°C to +105°C Cable Construction Soft annealed electrolytic copper Cu-ETP according to DIN EN 13602, Conductor construction according to ISO 6722 (Concentric conductor. Type A) PYC insulation, class B to ISO 6722 Properties The lead free, PVC polymer, offers excellent resistance to petrol, chemicals, and abrasion, and in addition is suitable for both low and. high temperature applications. Flame retardant to EN 60332-1-2 Packing Availabe in 100 mtrs. Longer length availabe in spools. Cable Design Parameters oz 7 21 or 348 865 02 12 0.6 7 026 os 5a 555 02 13 os 19 ong 10 375 382 22 16 075 19 023 12 27 254 024 19 1 9 026 1.38, 185 191 024 24 125 9 030 18 143 153 028 23 1s 9 os WwW 127 18 028 24 z 13 oar 20 942 969 028 28 28 19 oat 22 16 182 028 30 264 | RR KABEL FLRY B HH BBoHS = Application These ate thin walled cables ideal for use in automotives where its reduced insulation thicknese and higher temperature withstanding properties serves its application in complex wiring harnesses. Standard In accordance with 180 6722 Voltage Rating 60 D.C, 25V AC. (Suitable for 12 Volts and 24 Volts systems) Temperature Range (3000 Hrs) -40°Ct0 H105°C Cable Construction Soft annealed electrolytic copper Cu-ETP according to DIN EN 13602 Conductor construction according to ISO 6722 PVC insulation class 8 to 1S0 6722 Properties The lead free, PVC polymer offers excellent resistance to petrol, chemicals, and abrasion, and in addition is suitable for both fow and high temperature applications. Flame retardant to EN 60332-1-2, Packing Available in 100 mtrs. Longer length available in spools or wooden drums. Cable Design Parameters ee my Stands Diameter) DE) a apy tancopper THESE) iter) i 2 oat 13s ast 2 1s x 02s iar 3 ozs 24 3 és on toss 34 5 033 ose 42 RR KABEL | 265 FLUY REACH | RoHS | Orcas ee Application, These are ultrathin wal auto cables ideal for use in automotives Standard Inaceardance to 180 6722-1 ‘Temperature Range (3000 Hrs) 400 to #105" Cable Construction Soft annealed electrolytic copper Cu-ETP) according to DIN EN 13602, bare or tinned. Soft PVC insulation cold-resistant according to ISO 6722-1, Class 8 Packing Packing available in 100 mtrs, Longer length available in spools. Cable Design Parameters os 7 27 os 52 a6 12 01 40 05 19 oag 1 3a 016 1a “01 60 ors 19 024 12 247 016 16 “0.18 80 10 19 027 14 185 016 175; -0.15 100 1.25 19 030 1s 14s ors 20 02 130 16 19 03 7 ya a6 2a “02 180 20 19 aaz 19 az 020 24 -02 200 25 37 030 22 16 020 27 “02 250 266 | RR KABEL ACH | ROHS 1 CE FLRYW Pocus tee FLAYW with thin wall PVC insulation (Type A / Type B, hot pressure resistant) Application ‘These are thin wall auto cables with hot pressure resistant properties ‘Standard In accordance to ISO 6722-1 ‘Temperature Range (3000 Hrs) -A0°C to 125°C Cable Construction Soft annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned construction acc. to |80 6722-1 ‘Special PVC insulation with properties eccording to ISO 6722-1, lass C Special Properties Heat resistant cable, Suitable for applications inside the engine compartment Packing Availabe in 100 mtrs. Longer length available in spools or woaden drums. Cable Design Parameters oss 700k Smt os 3a 10s 2m os 12 mr home 08 108m SSS Sw) SomkSt) 0S 125s 1s Ms 89 ome we isos 17 ar 30 ome 208 2094296808202 a os ot os a5 maka ose ont 10s 2m oto 12 ar 4 mets 0a 102 om iss 8) meat 1s 1s Ms 89 ome okt 1s oa mr a0 oma 2s R KABEL 2 30 031 20 9.69 028 28-03 25 50 026 22 782 028 30-03 3 45 031 24 615 636 028 34-03 4 56 oat 275 an 485 sz 37-03 420 5 65 033 a1 a4 402 032 42-03 500 6 a4 on a3 ala 423 032 43-03 610 8 50 046 38 238 282 032 50-04 220 10 80 on 45 182185 ous 60-04 108.0 2 96 on 52 18216 048 65-07 1200 16 8 on 55 1161.18 052 72-08 170.0 20 152 oat 58 0955 0999 © 0s2 78-08 1920 5 196 on 78 aaa a7s7 se a7 08 265.0 268 | RR KABEL FLI1Y Mnete tT Conccl } ote FLITY with TPE-U insulation Application These are automotive cables for starting and charging application in motorcycles and other motor vehicles. The cable design makes it ‘suitable for harsh environment and robust applications Standard In accordance to 180 6722-1 ‘Temperature Range (3000 Hrs) 40°C to +110°C Cable Construction Soft annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare construction acc. To ISO 6722-1 TPE-U (Thermoplastic polyurathane elastomer) according to 1S0 6722-1, Class B Packing sai it oie: once nat lle napa rane ems Cable Design Parameters cutie Moet Mac sans andr iy Cra amt pox wht St in ey ee nd tm 6 oa oat 33 au 080500 0 eo oat 45 1 10st 16 we om 6a 6a os (1760 2 1 oat 1s ems 130k 080 35 a6 oa so oser a0 BO so we os] SSeS 20 so rn aos] 20080 6 ey ee ee ee) 120 608 ost 165 0.159 1.60 197 20 vi70.0 FLYY ae Cocca ete Application ‘These cables are ideal for use in automotive applications where higher current carrying capacity and mechnical strength are required Standard ‘Adapted to |SO 6722 Voltage Rating 60 VDC, 25V AC. (Suitable for 12 Volts and 24 Volts systems) ‘Temperature Range (3000 Hrs) 40°C to +105°C Cable Construction Soft annealed electrolytic copper Cu-ETP according to DIN EN 13602, Conductor construction according to 180 6722 PVC insulation, class B to ISO 6722 PVC sheath, class B to 180 6722 Properties The special cable construction offers higher mechanical strength without compromising with the cable flexibility. The cable is suitable ‘or rugged applications across the extreme temperature range. Packing Availabe in 100 mtrs. Longer length availabe in spools. Cable Design Parameters a a - e tect “taeet canter SCM an cater Tides (nm) ati tani THkness (te) rm) (om) wom oma 10 ~=~O«~S~SCtaTSC*iCS*‘“«‘iaSC«i:CSCSC*«iCSSC 1s meta 20 SoS 25~C~DS*~< SSCtiSStSSCSSSSC RR KABE ACH | ROHS 1 CE FLR13Y pera oe Application These are TPE-€ insulated low tension automotive cables used in motor vehicles for lghtings, signals and instrument panel circuits operating across wide range of extreme temperature ‘Standard Im accordance to 180 6722-1 class D ‘Temperature Range (3000 Hrs) 40°C to +150°C Cable Construction Soft annealed electrolytic copper Cu-ETP1 according to DIN EN 13602 bare conductor construction ace. To ISO 6722-1 Tinned copper available on request. TPE-E (Thermoplastic Elastomer) ‘Special Properties These ate polyester based elastomeric cables which offer consistent performance across the entire operating temperature range-Tear and abrasion resistant, High peak temperature resistance Good resistant to chemical and weather conditions. High impact strength. Packing Packing available in 100 mrs, Longer length available in spools. Cable Design Parameters, oz 7 az az sae 020 u 1 035 7 026 a8 saa 0.20 12 13 os 19 axa 10 a5 on 14 16 075 19 23 2 247 028 Ww 19 1 19 026 Las 185 026 19 21 1s 19 022 i 127 02 a2 24 2 19 oar 20 9a 028 25 28 25 9 as 22 16 028 aT 30 a 035 2 az as saa 020 12 14 as 6 a2 10 as 02 4 16 07s 2 az 12 2ar 024 7 19 1 2 az 138 185 028 18 21 15 30 026 7 ver 028 22 24 2 20 oat 20 942 028 25 28 25 50 026 22 7.50 028 ar 20 4 56 aa 218 an on a4 a7 6 84 ost 33 ala 032 40 43 FLRY n x (TWISTED CABLES) BEACHIY Ret -—— = Application ‘These are unsheathed twisted wires used in automobiles ‘Standard In accordance to 1S0 6722-1 Temperature Range (3000 Hrs) 40°C to +105°C Cable Construction ‘Soft annealed electrolytic copper Cu-ETP] according to DIN EN 13602, bare or tinned copper construction ace, to IS0 6722-1 PVC with properties according to according to 1S0 6722-1, Class B ‘Special Properties Higher heat resistance. Tinned copper conductor. Other lay lengths available on request. Packing Available in 100 mtrs. Longer length available in spools or wooden drums. Cable Design Parameters of cores op = Mat Strand Ma. Cvctee Minneuation outer ‘Approx. a ee cay Scininm) Sm aermy ties my”) unm) acm) a) 200.38 r 026 os 520.0 13 6 26 90 200.35 7 02 os -s20~—SC(O 20 13 20 26 90 200.35 7 02 os 5200 13 30 26 90 200.5 1901s 100 mo 15 32 130 240.5 1 019 re 2” 32 130 20.5 wom 1001 20 32 130 205 we 02 10 aloe 16 30 32 130 3x05 19018 10 mo 30 35 20 305 wom 10mm 40 35 200 n07s 8 12 mT Ome 30 38 180 wom 192 120 Tom 0 38 180 3075198 120 mT om 30 a1 m0 2x1 19 0% 135188 mk 30 42 220 2x1 som 30 a2 220 ai moat 135185 25 a5 330 4a 190% )=135 8S 30 51 440 25 1% ox W 270k 30 48 320 2125 50026 22 18 028 30 30 60 520 525 (026 22 78 028 30 50 811300 6x25 50 026 22 78 028 30 55 a0 1560 ACW REACH | ROHS 1 CE ram coer Application These are power train cables for automobiles, These are used in wire harness of low-tension engine compartment circuits for automo- biles ‘Max. Operating Temperature 150°C Cable Construction Bare of annealed tinned copper TPE-€ (Thermoplastic Elastomer) Packing Available in 100 mtrs. Longer length available in spools. Cable Design Parameters 035 7 0.26 09 520 025 12 14 0.50 9 020 10 374 030 14 16 07s 19 024 1.20 247 035 Ww 19 10 19 026 1.35 185 038 19 21 15 20 026 ur 127 038 22 24 25 50 0.26 22 76 0.40 27 30 40 56 ost 275 ar os 34 37 60 84 oat 33 31 050 40 43 “Nee Tene cope cond oan be rovded on est RRKABEL | 273 THIN WALL MULTICORE CABLES ' Cocca Application These are multicore cables used in automobile Standard Inaccordance to 1S0 6722-1 Cable Construction Hlectroiytic plain annealed copper according to ISO 6722-1 PVC with properties according to according to ISO 6722-1, Class B (105°C). PVC Sheathed 105°C. Packing ‘Availabe in 100 mtrs. Longer length available in spools or wooden drums. Thin Wall 2 Core Auto Cables (Flat Twins) i. of Cones No.of Massena Max. over Noni Seen EoGL ee eae, sheath Colour core colour 205 16 0.20 27446 25075 24 0.20 31x49 2.0 2 0.20 30x50 ae Et ae — Black Black, Red 2a.0 28 0.30 39465 2x25 35 0.30 39x67 218.0 a 0.30 43x75 2s 65 0.30 55x94 Thin Wall 2 Core Auto Cables (Round Twins) RR KABEL am oof Cores x " 2 No.of ae, Sand Mas Overall Noni stan pend a= ered ‘Sheath Colour ore Colour 205 16 0.20 52 290.75 24 0.20 53 21.0 2 0.20 5 Black Black, Red as a 030 64 22.0 28 0.20 68 208 35 0.30 67 Thin Wall 3 Core Auto Cables RR KABEL ea No.of cores x ' No.of Mae Stand Ma. Overall Nomital Cross-Section eae ae rere Sheath Colour ore Colow 300.75 2 0.20 57 30.0 2 020 55 Black Red, Black a5 2 0.30 59 Green 320 28 030 7a Thin Wall 3 Core Auto Cables RR KABEL ats No.of Cores No.of ox. Stand ax ovat ease me oe Stands Condit rm) ameter) an a 9075 2 0.20 53 Brown, Green 40.0 2 0.20 52 Black Red, White a5 2 0.30 16 Thin Wall 5 Core Auto Cables [i ti ind) 12 == Wo. of Cores X j No.of Max. Stand Max. Overall ‘Nomina Cross-Sestion ee a om) pater ‘Sheath Colour ‘core Colour 50.75 24 0.20 59 x10 32 0.20 58 Teer Brown, Green, 2 0.30 ec Red, White, Yellow 400.04 1K2.0 76 28 0.30 Thin Wall 7 Core Auto Cables pores f vom i. of Cores (oss Seton No.of ae. Stand Max. over Stel oo Stands cant) Daneter(rm) SteathCaour coe Clow 705 16 0.20 ‘ 110.75 2 0.20 68 me = a a Black Black Red, Green, 4x1.041x20 2 020 Yellow, Brown, ayers 28 0.30 as White, Blue 1.04 1x20 EY 90) a.0+ x 35 0.30 ao corey Thin Wall 8 Core Auto Cables Coes fs ttn io. ofcoes No.of ax. Sand Max. Osea eee Stands canter) Danetrirm) Stestoe, onGien Black Red, Blue 7x10 + 1x2.0 32 0.20 BB Black Yellow, Purple, Brown, 28 ox20 White, Green Thin Wall 10 Core Auto Cables RR KABEL sn No.of Cores " ¥ No.of ua stand a. vera Noni Seton Stands contr) Dane trn) Seah cao Corcolew Black, Re, Green Gry. 9x1.0+ 1x20 8 20 10.90 Black Bue, Yalow, town, 8 0320 Orange Purple White Thin Wall 13 Core Auto Cables RR KABEL ‘te No.of Cores x No.of ae Stand as Overt Nominal rss Section Teh me, || ee see ee Cae Colo Yellow, sive, Gren, Brown, 121.6 +125, 2 2.30 1230 Red/Black Black, Red Fink, Purple, 35 0.30 lack —_ 818% hte Light Brown Orange 30 0.25 Black, Red Green, Grey, Ble. Yellow, 1.5 +5125 13.30 n, Orange, Purple White <0 bos ‘Brown, Orange, Purple, Whit TINNED COPPER CABLES Ca 8] Application Tin plated single and mult core cable for starting. charging and instrument panel circuits in automobiles. Standards In accordance to ISO 6722-1 Cable Construction Electrolytic annealed tinned copper as per 180 6722-1 PYC with properties according to according to ISO 6722-1, Class & (105°C) Packing Ava in 100 mis. Longer length vale in spool or wooden drs Single Core Cable sonal a Site ate 10 2 020 1s n 030 25 % 00 a0 ss a0 60 a a0 100 eo oo Tinned Copper 2 Core Cables (Flat Twins) Standards In accordance to ISO 6722-1 Cable Construction PVC with properties according to according to ISO 6722-1, Class B (105°C) PVC Sheathed 105°C Packing ‘Available in 100 mtrs. Longer length availabe in spools or wooden drums. RR KABEL io of Cores X : . No.of Mag, Sand ax. Overall ema el Stonds Conductor (re) Diameter (rm) 2x15 2 0.30 35x58 2x25 35 0.20 39x67 Max, 0¢ Conductor ste Diameter ce (ax) an) 120% (rem) 2 191 24 130 30 782 37 4.85 43 3.23 60 1.85 ‘Sheath Colour ore Colour White” Black Red, Black Tinned Copper 2 Core Cables (Round Twins) Standards In accordance to 180 6722-1 Cable Construction PVC with properties according to according to IS0 6722-1, Class B (105°C) PVC Sheathed 105°C Packing Available in 100 mtrs. Longer length available in spools or wooden drums face oof cores x sot ns sn eo Nenieltes-ieten cmc aera axis a 20 sa 2x28 3 020 61 Tinned Copper 3 Core Cables Standards In accordance to ISO 6722-1 Cable Construction PVC with properties according to according to ISO 6722-1, Clase B (105°C) PVC Sheathed 105°C Packing ‘Available in 100 mtrs. Longer length available in spools or wooden drums circ No.of Cores x toot " ys Sans oo once eee | ae cendaerinm) amin) axis n 0.90 59 2x28 35 0.30 14 gy ‘heath Clout cove Colow Black Black, Red ~ - ag ‘Sheath Colour ‘ore Colow White/Black Black, Red, Green PVC BATTERY CABLE BAe OTC ete Voltage Rating Max. 200V Test Voltage 1000 Volts Temperature Range 30°C to #70" Cable Construction Annealed Bare copper strands For PVC battery cable - Cl. 5 to EN 60228 For Flexible PVC battery cable - Cl. 6 to EN 60228 YC insulation ever bunched conductor Packing ‘Available in wooden drums. Cable Design Parameters Standard Battery Cable 8 196 0.40 97 0780 35 26 0.40 122 0554 50 396 0.40 133 0.386 0 360 050 146 o272 Flexible Battery Cable 6 512 0.20 83 121 6 800 020 101 0780 35 1120 0.20 ne 0.554 0 705 0.30 133 0.386 0 990 0.30 185 0272 5 1340 0.30 3 0.206 120 1690 0.30 yar 0.161 280 | RR KABEL ELASTOMERIC BATTERY CABLE Mnete tT CCC ‘nies ——| Standard ‘Adapted to BS 6862 Voltage Rating Max, 2000 Test Voltage 1000 Volts Temperature Range (3000 Hrs) 40°Ct0 + 90°C Cable Construction Bare copper strands as per EN 60228, class 6 Packing Available in wooden drums, Conductor Bunch Variants Normal flex and Super flex Special Elastomeric insulation Thermoplastic Elastomer Vuleanizate Special Properties Acid Resistance Test: n sulphuric acid of specific gravity 1.28 at a temperature of 160°C to 210°C and check the cable after 60 hrs No effect on insulation. Insulation free from deformation and shrinkage Chemical Resistance: Resistant to ozone. acids, solvents, detergents, vaseline and oils. Cable Design Parameters Super Flex Nominal ross Seton No.of Max. Sand ‘uterDiameter Max DC Conductor Resistance on) ameter mim (ax) (om) 20°C (ark) % 784 020 mi 078 35 1% 020 128 0.554 80 1568 020 140 0.386 0 2208 020 160 0272 95 2989 020 180 0.206 120 3850 020 203 0161 Normal Flex Nominal ross-Seton No.of Max. Sand ‘uterDiameter Max. DE Conductor Resistance (om) Sands Diameter mm (at) (rm) ‘2050 (rm) 28 816 020 m1 078 38 naa 0.20 128 0.554 80 1662 020 40 0.386 70 2346 020 160 oz 95 3050 020 180 0.208 COPPER EARTHING BRAIDS REACH | RoHS 1 CE | CPR Compliant Application Tubular braids are used for covering and shielding, They protect the cables and electrical conductors against interferences and to realize a safe data transfer. Material ‘Anneeled electrolytic grade copper wire, Wire Dia - 0.16 to 03mm Test Voltage 3000 Surface Plain copper or Tinned Packing In ings or spools or wooden drums. Tubular Braids 790 3X7 02 8s 5 1020 36x 9 02 10 7 1245 36K 1 02 12 Ey 35.80 36 X14 03 8 70 su10 48 X 15 03 8 90 ‘Tinned Copper Earthing Braids 19 16 X16 og 720 ar 16 x 32 o3 Mm ‘We can also produce special designs in diameters and constructions according to customer requirement, 282 | RR KABEL PVC IGNITION CABLE cc = Application ‘gnition Cable transfers high voltage energy from istributors/eolls to spark plugs. Standard ‘Adapted to BS 6862 Part-1 & 1S 2465 Max. Operating Temperature 0c Cable Construction, Annealed Bare Copper, cl. 2 PVC Core insulation PVC Sheath ‘Sheath colour - black Packing Available in 100 mtrs. coils. Longer length availabe in spools or wooden drums: Properties + Flame retardant to EN 60332-1-2 Cable Design Parameters, Nom “Total Radia is Max Scand ros: Section “Thickness of ‘com cl covering (rm) 18. asi 28 om Cable ‘Aprox Weight Diameter (mm) ‘oi 79 625

You might also like