You are on page 1of 122

This Product has been discontinued

Spec Sheet

Cisco UCS C240 M4


High-Density
Rack Server (Small Form
Factor Disk Drive Model)

CISCO SYSTEMS PUBLICATION HISTORY


170 WEST TASMAN DR.
SAN JOSE, CA, 95134 REV E.20 MARCH 23, 2021 
WWW.CISCO.COM
CONTENTS

OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . 11
CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
STEP 1 VERIFY SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
STEP 2 SELECT RISER CARDS (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
STEP 3 SELECT LOCKING SECURITY BEZEL (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . 18
STEP 4 SELECT CPU(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
STEP 5 SELECT MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
STEP 6 SELECT RAID CONTROLLERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
RAID Controller Options (internal HDD/SSD support) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Embedded Software RAID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Cisco 12G SAS Modular RAID Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
SAS HBA (internal HDD/SSD/JBOD support) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
SAS HBA (external JBOD support) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
RAID Volumes and Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
STEP 7 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs) . . . . . . . . . . . . . 39
STEP 8 SELECT SED HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs) . . . . . . . . . . 45
STEP 9 SELECT PCIe OPTION CARD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
STEP 10 ORDER OPTIONAL NETWORK CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . 53
STEP 11 ORDER GPU CARDS AND GPU POWER CABLES (OPTIONAL) . . . . . . . . . . . . . . . . . 58
STEP 12 ORDER POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
STEP 13 SELECT AC POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
STEP 14 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . 65
STEP 15 SELECT NIC MODE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
STEP 16 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . 67
STEP 17 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) . . . . . . . . . . . . . . . 69
STEP 18 ORDER OPTIONAL USB 3.0 DRIVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
STEP 19 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . 71
STEP 20 SELECT OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
STEP 21 SELECT SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
OPTIONAL STEP - ORDER RACK(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
CPUs and DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Physical Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Memory Population Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
DIMM Population Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Recommended Memory Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Additional DIMM Populations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
RAID Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Cisco 12G SAS Modular RAID Controller (RAID Support) . . . . . . . . . . . . . . . . . . . . . . 91
Cisco 12 Gbps SAS HBA (JBOD Only Support) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
RAID Option ROM (OPROM) Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Riser Card Configuration and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

2 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
Embedded SATA RAID: Two SATA Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Serial Port Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Upgrade and Servicing-Related Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Adding an Additional CPU (with CPU heat sink) or Replacing CPUs . . . . . . . . . . . . . 100
Motherboard Lithium Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Thermal Grease (with syringe applicator) for CPU to Heatsink Seal . . . . . . . . . . . . . 100
Air Baffle Replacement Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
CPU Heat Sink Cleaning Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
RACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
KVM CABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Motherboard USB and SD Ports, and RAID Card Backup Locations . . . . . . . . . . . . . . . . . . 106
NEBS Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
END OF SALE (EOS) COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Dimensions and Weight . . . . . . . . . . . . . . . . . . . . ... .... ... .... .... ... .... . 111
Power Specifications . . . . . . . . . . . . . . . . . . . . . ... .... ... .... .... ... .... . 112
Environmental Specifications . . . . . . . . . . . . . . . . ... .... ... .... .... ... .... . 116
Compliance Requirements . . . . . . . . . . . . . . . . . . ... .... ... .... .... ... .... . 117

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 3
CONTENTS

4 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
OVERVIEW

OVERVIEW
The UCS C240 M4 small form factor (SFF) server is the newest 2-socket, 2U rack server from Cisco, designed
for both performance and expandability over a wide range of storage-intensive infrastructure workloads
from big data to collaboration.

The enterprise-class UCS C240 M4 SFF server extends the capabilities of Cisco’s Unified Computing System
portfolio in a 2U form factor with the addition of the Intel® Xeon E5-2600 v3 and v4 series processor family
that delivers the best combination of performance, flexibility, and efficiency gains. In addition, the UCS
C240 M4 SFF server provides 24 DIMM slots, up to 6 PCI Express (PCIe) 3.0 slots, up to 24 front-loading drives
plus two (optional) internal SATA boot drives for a total of 26 internal drives.

The C240 M4 server includes a modular LAN on motherboard (mLOM) slot for installation of a Cisco Virtual
Interface Card (VIC) or third-party network interface card (NIC) without consuming a PCI slot in addition to
2 x 1 GbE embedded (on the motherboard) LOM ports. These features combine to provide outstanding levels
of internal memory and storage expandability along with exceptional performance.

The Cisco UCS C240 M4 server can be used standalone, or as part of the Cisco Unified Computing System,
which unifies computing, networking, management, virtualization, and storage access into a single
integrated architecture enabling end-to-end server visibility, management, and control in both bare metal
and virtualized environments.

Figure 1 Cisco UCS C240 M4 High-Density SFF Rack Server (24-drive version)

Front View

Rear View

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 5
DETAILED VIEWS

DETAILED VIEWS
Chassis Front View
Figure 2 shows the 24-drive Cisco UCS C240 M4 High-Density SFF Rack Server.

Figure 2 Chassis Front View (24-drive version)

2
HDD01
HDD02
HDD03
HDD04
HDD05
HDD06
HDD07
HDD08
HDD09
HDD10
HDD11
HDD12
HDD13
HDD14
HDD15
HDD16
HDD17
HDD18
HDD19
HDD20
HDD21
HDD22
HDD23
HDD24

352943
3 10

4 11
5
6
7
8
9

1 Drive bays 1–24 (up to 24 2.5-inch drives) 7 Temperature status LED

2 Operations panel buttons and LEDs 8 Power supply status LED

3 Power button/LED 9 Network link activity LED

4 Unit Identification button/LED 10 Pull-out asset tag

5 System status LED 11 KVM connector


(used with KVM cable that provides two USB
2.0, one VGA, and one serial connector)

6 Fan status LED

6 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS

Figure 3 shows the 16-drive Cisco UCS C240 M4 High-Density SFF Rack Server.

Figure 3 Chassis Front View (16-drive version)

3 4 6 8

5 7 9

10
2 11

HDD01 HDD02 HDD09 HDD10


HDD03 HDD04 HDD11 HDD12
1
HDD05 HDD06 HDD13 HDD14

352944
HDD07 HDD08 HDD15 HDD16

1 Drive bays 1–16 (up to 16 2.5-inch drives) 7 Temperature status LED

2 Operations panel buttons and LEDs 8 Power supply status LED

3 Power button/LED 9 Network link activity LED

4 Unit Identification button/LED 10 KVM connector


(used with KVM cable that provides two USB
2.0, one VGA, and one serial connector)

5 System status LED 11 Pull-out asset tag

6 Fan status LED

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 7
DETAILED VIEWS

Figure 3 shows the 8-drive Cisco UCS C240 M4 High-Density SFF Rack Server.

Figure 4 Chassis Front View (8-drive version)

3 4 6 8

5 7 9

10
2 11

HDD01 HDD02
1 HDD03 HDD04
HDD05 HDD06

352945
HDD07 HDD08

1 Drive bays 1–8 (up to 8 2.5-inch drives) 7 Temperature status LED

2 Operations panel buttons and LEDs 8 Power supply status LED

3 Power button/LED 9 Network link activity LED

4 Unit Identification button/LED 10 KVM connector


(used with KVM cable that provides two USB
2.0, one VGA, and one serial connector)

5 System status LED 11 Pull-out asset tag

6 Fan status LED

For more information about the KVM cable connection, see KVM CABLE, page 105.

8 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS

Chassis Rear View


Figure 5 shows the external features of the rear panel (identical for all server versions).

Figure 5 Chassis Rear View

1 2 3

PCIe 03 PCIe 06
PSU 02 11
PCIe 02 PCIe 05
PCIe 01 PCIe 04
PSU 01

352947
mLOM

4 5 6 7 8 9 10

1 PCIe riser 1 (slots 1, 2, 3*) 7 Serial connector (RJ-45)1


*Slot 3 not present in all versions. See Riser
Card Configuration and Options, page 93
for details.
2 PCIe riser 2 (slots 4, 5, 6), See Riser Card 8 Two embedded (on the motherboard) Intel
Configuration and Options, page 93 for i350 GbE Ethernet controller ports
details.
LAN1 is left connector,
LAN2 is right connector
3 Power supplies (DC power supplies shown) 9 VGA video port (DB-15 connector)
4 Modular LAN-on-motherboard (mLOM) card 10 Rear Unit Identification button/LED
slot
5 USB 3.0 ports (two) 11 Grounding-lug holes (for DC power supplies)
6 1-Gbps dedicated management port —

Notes . . .
1. For serial port pinout details, see Serial Port Details, page 98

The port numbers for an mLOM VIC (for example, the VIC 1227T) and for a PCIe VIC (for example, the VIC
1225T) are shown in Figure 6. In the case of both cards, the Port 1 connector is on the right and the Port 2
connector is on the left.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 9
DETAILED VIEWS

Figure 6 VIC Port Numbering

VIC 1227T

VIC 1225T

10 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
BASE SERVER STANDARD CAPABILITIES and FEATURES

BASE SERVER STANDARD CAPABILITIES and FEATURES


Table 1 lists the capabilities and features of the base server. Details about how to configure the server for
a particular feature or capability (for example, number of processors, disk drives, or amount of memory)
are provided in CONFIGURING the SERVER, page 15.

Table 1 Capabilities and Features

Capability/Feature Description
Chassis Two rack unit (2RU) chassis
CPU One or two Intel Xeon E5-2600 v3 or v4 series processor family CPUs
Chipset Intel® C610 series chipset
Memory 24 slots for registered ECC DIMMs (RDIMMs) or load-reduced DIMMs (LRDIMMs)
Multi-bit Error This server supports multi-bit error protection.
Protection
Expansion slots Up to six PCIe slots (on two riser cards)
 Riser 1 (PCIe slots 1, 2, and 3), controlled by CPU 1
• Option A: Two slots available. Slot 1 = full height, 3/4 length, x8, NCSI1.
Slot 2 = full height, full length, x16, NCSI, GPU capable. NCSI is supported
on only one slot at a time.
• Option B: Three slots available. Slot 1 = full height, 3/4 length, x8. Slot 2
= full height, full length, x8, NCSI. Slot 3 = full height, full length, x8.
• Option C: Two slots available. Slot 1 = full height, 3/4 length, x8, NCSI.
Slot 2 = full height, full length, x16, NCSI. In addition, the riser contains
two connectors for connecting up to two SATA boot drives.
 Riser 2 (PCIe slots 4, 5, and 6), controlled by CPU 2. Three slots available.
Slot 4 = full height, 3/4 length, x8, NCSI. Slot 5 = full height, full length, x16,
NCSI, GPU capable. Slot 6 = full height, full length, x8. NCSI is supported on
only one slot at a time.
 Dedicated RAID controller slot (see Figure 9 on page 82)
• An internal slot is reserved for the Cisco 12G SAS Modular RAID controller.

For more details on riser 1 and riser 2 see Riser Card Configuration and
Options, page 93.
PCIe Interposer An optional interposer board inside the chassis containing two mini-SAS HD
Board connectors allows two front-mount NVMe SFF 2.5” drives to mount in drive bays 1
and 2 (only) and connect to the PCIe bus of CPU2.
Video The Cisco Integrated Management Controller (CIMC) provides video using the
Matrox G200e video/graphics controller:

 Integrated 2D graphics core with hardware acceleration


 DDR2/3 memory interface supports up to 512 MB of addressable memory (8 MB
is allocated by default to video memory)
 Supports display resolutions up to 1920 x 1200 16bpp @ 60Hz
 High-speed integrated 24-bit RAMDAC
 Single lane PCI-Express host interface running at Gen 1 speed

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 11
BASE SERVER STANDARD CAPABILITIES and FEATURES

Capability/Feature Description
Internal storage Drives are installed into front-panel drive bays that provide hot-pluggable access.
devices
 Small Form Factor (SFF) drives. The server can hold up to:
• 24 2.5 inch (63.5 mm) SAS/SATA hard drives (HDDs) or SAS/SATA solid state
drives (SSDs)2 with the 24-drive backplane (with expander) server
configuration, plus two optional internal 2.5 inch SATA SSDs for booting an
OS.
• 16 2.5 inch (63.5 mm) SAS/SATA HDDs or SAS/SATA SSDs with the 16-drive
backplane (with expander) server configuration
• 8 2.5 inch (63.5 mm) SAS/SATA HDDs or SAS/SATA SSDs with the 8-drive
backplane server (no expander) configuration.
• NVMe SFF 2.5” drives These drives can placed in front drive bays 1 and 2
only.
 The server also contains one internal USB 3.0 port on the motherboard that
you can use with an optional 16 GB USB thumb drive for additional storage
 UCS Storage Accelerators are also available. These PCIe plug-in flash storage
cards provide independent high-speed storage.
Cisco Flexible Flash The server supports up to two internal 32 GB or two internal 64 GB Cisco Flexible
drives Flash drives (SD cards).
The second SD card is blank and can be used to mirror the first SD card. It can be
used to protect the Hypervisor Partition with RAID1.
Interfaces  Rear panel

• One DB15 VGA connector


• One RJ45 serial port connector
• Two USB 3.0 port connectors
• One RJ-45 10/100/1000 Ethernet management port, using Cisco Integrated
Management Controller (CIMC) firmware
• Two Intel i350 embedded (on the motherboard) GbE LOM ports
• One flexible modular LAN on motherboard (mLOM) slot that can
accommodate various interface cards
 Various PCIe card ports (dependent on which cards are installed)
• Virtual Interface Card (VIC) ports
• Converged Network Adapter (CNA) ports
• Network Interface Card (NIC) ports
• Host Bus Adapter (HBA) ports
 Front panel
• One KVM console connector (supplies two USB 2.0 connectors, one VGA
DB15 video connector, and one serial port (RS232) RJ45 connector)
Power subsystem Up to two of the following hot-swappable power supplies:
 650 W (AC)
 1200 W (AC)
 1400 W (AC)
One power supply is mandatory; one more can be added for 1 + 1 redundancy.

12 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
BASE SERVER STANDARD CAPABILITIES and FEATURES

Capability/Feature Description
Storage controller  Embedded Software RAID (6 Gbps)
• Embedded SATA-only RAID controller, supporting up to 8 SATA-only drives
(RAID 0, 1), or
• Embedded Software RAID 5 key upgrade, supporting up to 8 SATA-only
drives (RAID 0, 1, 10, 5)

Note that embedded RAID options can be supported only with the version of the
C240 M4 SFF server that has been configured with an 8-drive backplane.

 Cisco 12G SAS Modular RAID controller card with internal SAS connectivity.
• Supports up to 24 internal drives
• Plugs into a dedicated RAID controller slot
 Can be purchased alone, or along with an onboard Flash-Backed Write Cache
(FBWC) upgrade option, as shown in the table below

RAID Card Version Supported RAID Levels Onboard FBWC

UCSC-MRAID12G1 JBOD, 0, 1, 10 None

UCSC-MRAID12G-1GB2 JBOD, 0, 1, 10, 5, 6, 50, 60 1 GB

UCSC-MRAID12G-2GB2 JBOD, 0, 1, 10, 5, 6, 50, 60 2 GB

UCSC-MRAID12G-4GB2 JBOD, 0, 1, 10, 5, 6, 50, 60 4 GB

Notes . . .
1. Base RAID controller card (RAID 0, 1, 10 only)
2. FBWC option for base RAID controller card (adding the FBWC option extends the
RAID levels)

All versions of the UCSC-MRAID12G RAID controller support up to 24 internal SAS


drives on the 24-drive backplane version of the server, up to 16 drives on the
16-drive backplane version, or up to 8 drives on the 8-drive backplane version.
WoL The 1-Gb Base-T Ethernet LAN ports support the wake-on-LAN (WoL) standard.
Front Panel A front panel controller provides status indications and control buttons
ACPI This server supports the advanced configuration and power interface (ACPI) 4.0
standard.
Fans Chassis:
 Six hot-swappable fans for front-to-rear cooling
Boot drives Up to two optional SATA drives can be installed internal to the chassis on riser 1.
The two SATA boot drives are supported only on the 24-drive backplane chassis
version and are managed in AHCI mode, using OS-based software RAID.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 13
BASE SERVER STANDARD CAPABILITIES and FEATURES

Capability/Feature Description
Storage controller  Cisco 12 Gbps Modular SAS HBA with internal SAS connectivity
• Supports up to 24 internal drives
• Is compatible with all backplane versions (8-, 16-, and 24-drive
backplanes)
• Plugs into a dedicated PCIe slot at the rear of the server (slot 1 of riser 1)
• Supports JBOD only, not RAID, as shown in the below table.

HBA Card Version Supported RAID Levels

UCSC-SAS12GHBA JBOD only

 Cisco 9300-8E 12G SAS HBA with external SAS connectivity


• Provides 8 external SAS ports
• Plugs into a PCIe slot at the rear of the server
• No FBWC (cache) or cache power backup
• SAS 3.0 compliant
Embedded NIC Two embedded (on the motherboard) Intel i350 GbE ports, supporting the
following:

 Pre-Execution Boot (PXE boot)


 iSCSI boot
 Checksum and segmentation offload
 NIC teaming
Modular LAN on The mLOM slot can flexibly accommodate the following cards:
Motherboard
(mLOM) slot  Cisco Virtual Interface Cards (VIC)
 Quad Port Intel i350 1GbE RJ45 Network Interface Card (NIC)

NOTE: The four Intel i350 ports are provided on an optional card 
that plugs into the mLOM slot, and are separate from the two embedded
(on the motherboard) LAN ports

Integrated Baseboard Management Controller (BMC) running Cisco Integrated Management


management Controller (CIMC) firmware.
processor
Depending on your CIMC settings, the CIMC can be accessed through the 1-GbE
dedicated management port, the 1-GbE LOM ports, or a Cisco virtual interface
card (VIC).

Notes . . .
1. NCSI = Network Communications Services Interface protocol. An NCSI slot is powered even when the server is in
standby power mode.
2. The drives are available as both self-encrypted drives (SED) and non self-encrypted drives.

14 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

CONFIGURING the SERVER


Follow these steps to configure the Cisco UCS C240 M4 High-Density SFF Rack Server:

 STEP 1 VERIFY SERVER SKU, page 16


 STEP 2 SELECT RISER CARDS (OPTIONAL), page 17
 STEP 3 SELECT LOCKING SECURITY BEZEL (OPTIONAL), page 18
 STEP 4 SELECT CPU(s), page 19
 STEP 5 SELECT MEMORY, page 21
 STEP 6 SELECT RAID CONTROLLERS, page 27
 STEP 7 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs), page 39
 STEP 8 SELECT SED HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs), page 45
 STEP 9 SELECT PCIe OPTION CARD(s), page 48
 http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html,
page 52
 STEP 11 ORDER GPU CARDS AND GPU POWER CABLES (OPTIONAL), page 58
 STEP 12 ORDER POWER SUPPLY, page 61
 STEP 13 SELECT AC POWER CORD(s), page 62
 STEP 14 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE MANAGEMENT
ARM, page 65
 STEP 15 SELECT NIC MODE (OPTIONAL), page 66
 STEP 16 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL), page 67
 STEP 17 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL), page 69
 STEP 18 ORDER OPTIONAL USB 3.0 DRIVE, page 70
 STEP 19 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 71
 STEP 20 SELECT OPERATING SYSTEM MEDIA KIT, page 74
 STEP 21 SELECT SERVICE and SUPPORT LEVEL, page 75
 OPTIONAL STEP - ORDER RACK(s), page 80
 OPTIONAL STEP - ORDER PDU, page 81

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 15
CONFIGURING the SERVER

STEP 1 VERIFY SERVER SKU


Select one server product ID (PID) from Table 2.

Table 2 PID of the C240 M4 High-Density SFF Rack Base Server

Product ID (PID) Description

UCSC-C240-M4SX UCS C240 M4 SFF, no CPU, memory, HDD, SSD, PCIe cards, tool-less rail kit, or
power supply, with 24-drive backplane with SAS expander

UCSC-C240-M4S2 UCS C240 M4 SFF, no CPU, memory, HDD, SSD, PCIe cards, tool-less rail kit, or
power supply, with 16-drive backplane with SAS expander

UCSC-C240-M4S UCS C240 M4 SFF, no CPU, memory, HDD, SSD, PCIe cards, tool-less rail kit, or
power supply, with 8-drive backplane with no SAS expander

UCSC-C240-M4SNEBS UCS C240M4 NEBS SFF 16 HDD, no expander, CPU, memory, HDD, PCIe cards,
power supply, or rail kit1

Notes . . .
1. See NEBS Compliance, page 107 for more details.

The Cisco UCS C240 M4 server:

 Includes either a 24-, 16-, or 8-drive backplane.

NOTE: Embedded Software RAID can only be used with the 8-drive
backplane version of the server.

The Cisco 12G SAS Modular RAID controller and Cisco 12 Gbps Modular
SAS HBA can be used with any backplane version.

NOTE: The C240 M4 SFF server hard drive backplane is not field
upgradeable. This means, for example, that you cannot “upgrade” from
the 8-drive backplane version to the 16-drive or 24-drive backplane
version or from the 16-drive backplane version to the 24-drive backplane
version. Likewise, the backplane is not field “downgradeable.”

 Does not include power supply, CPU, memory, hard disk drives (HDDs), solid-state drives
(SSDs), boot drives, SD cards, riser 1, riser 2, tool-less rail kit, or PCIe cards.

NOTE: Use the steps on the following pages to configure the server with
the components that you want to include.

16 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 2 SELECT RISER CARDS (OPTIONAL)


There are two optional riser cards, riser card 1 and 2. There are three options for riser card 1.
Order one riser card 1 from Table 3 and one riser 2 card from Table 4. Riser card 1 is the one on
the left when viewed from the back of the server and riser card 2 is on the right.

Table 3 Riser 1 Options

Product ID (PID) Description

UCSC-PCI-1A-240M4 C240 M4 PCIe Riser 1 Assy (option A)


(2 PCIe slots: 1x8 and 1x16 GPU capable)

UCSC-PCI-1B-240M4 C240 M4 PCIe Riser 1 Assy (option B)


(3 PCIe slots: 3x8)

UCSC-PCI-1C-240M4 C240 M4 PCIe Riser 1 Assy (option C)


(2 PCIe slots: 1x8 and 1x16 plus connectors for 2 SATA boot drives)

The selection of riser card 1 determines the number and type of PCIe cards and SATA boot drives
supported in the riser.

Table 4 Riser 2 Options

Product ID (PID) Description

UCSC-PCI-2-C240M4 PCIe Riser Board (Riser 2) for C240 M4 (3 slots: 2x8 and 1x16)

NOTE: If no riser is selected, a riser blanking panel will be installed. You will not be
able to install any PCIe cards without a riser selected

For additional details, see Riser Card Configuration and Options, page 93.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 17
CONFIGURING the SERVER

STEP 3 SELECT LOCKING SECURITY BEZEL (OPTIONAL)


An optional locking bezel can be mounted to the front of the chassis to prevent unauthorized
access to the drives.

Select the locking bezel from Table 5.

Table 5 Locking Bezel Option

Product ID (PID) Description

UCSC-BZL-C240M4 C240 M4 Security Bezel

18 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 4 SELECT CPU(s)


The standard CPU features are:

 Intel Xeon E5-2600 v3 and v4 series processor family CPUs


 Intel C610 series chipset
 Cache size of up to 55 MB

Select CPUs

The available CPUs are listed in Table 6.


Table 6 Available Intel CPUs

Highest
Clock Cache DDR4 DIMM
Intel Power
Product ID (PID) Freq Size Cores QPI Clock
Number (W)
(GHz) (MB) Support
(MHz)1
E5-2600 v4 Series Processor Family CPUs
UCS-CPU-E52699AE E5-2699A v4 2.40 145 55 22 9.6 GT/s 2400
UCS-CPU-E52699E E5-2699 v4 2.20 145 55 22 9.6 GT/s 2400
UCS-CPU-E52698E E5-2698 v4 2.20 135 50 20 9.6 GT/s 2400
UCS-CPU-E52697AE E5-2697A v4 2.60 145 40 16 9.6 GT/s 2400
UCS-CPU-E52697E E5-2697 v4 2.30 145 45 18 9.6 GT/s 2400
UCS-CPU-E52695E E5-2695 v4 2.10 120 45 18 9.6 GT/s 2400
UCS-CPU-E52690E E5-2690 v4 2.60 135 35 14 9.6 GT/s 2400
UCS-CPU-E52683E E5-2683 v4 2.10 120 40 16 9.6 GT/s 2400
UCS-CPU-E52680E E5-2680 v4 2.40 120 35 14 9.6 GT/s 2400
UCS-CPU-E52667E E5-2667 v4 3.20 135 25 8 9.6 GT/s 2400
UCS-CPU-E52660E E5-2660 v4 2.00 105 35 14 9.6 GT/s 2400
UCS-CPU-E52650E E5-2650 v4 2.20 105 30 12 9.6 GT/s 2400
UCS-CPU-E52650LE E5-2650L v4 1.70 65 35 14 9.6 GT/s 2400
UCS-CPU-E52643E E5-2643 v4 3.40 135 20 6 9.6 GT/s 2400
UCS-CPU-E52640E E5-2640 v4 2.40 90 25 10 8.0 GT/s 2133
UCS-CPU-E52637E E5-2637 v4 3.50 135 15 4 9.6 GT/s 2400
UCS-CPU-E52630E E5-2630 v4 2.20 85 25 10 8/0 GT/s 2133
UCS-CPU-E52630LE E5-2630L v4 1.80 55 25 10 8.0 GT/s 2133
UCS-CPU-E52623E E5-2623 v4 2.60 85 10 4 8.0 GT/s 2133
UCS-CPU-E52620E E5-2620 v4 2.10 85 20 8 8.0 GT/s 2133
UCS-CPU-E52609E E5-2609 v4 1.70 85 20 8 6.4 GT/s 1866
UCS-CPU-E52658E E5-2658 v4 2.30 105 35 14 9.6 GT/s 2400
UCS-CPU-E52680D E5-2680 v3 2.50 120 30 12 8.0 GT/s 2133
UCS-CPU-E52640D E5-2640 v3 2.60 90 20 8 6.4 GT/s 1866

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 19
CONFIGURING the SERVER

Table 6 Available Intel CPUs

Highest
Clock Cache DDR4 DIMM
Intel Power
Product ID (PID) Freq Size Cores QPI Clock
Number (W)
(GHz) (MB) Support
(MHz)1
UCS-CPU-E52620D E5-2620 v3 2.40 85 15 6 6.4 GT/s 1866
UCS-CPU-E52609D E5-2609 v3 1.90 85 15 6 1600
UCS-CPU-E52658D E5-2658 v3 2.20 105 30 12 8.0 GT/s 2133

Notes . . .
1. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be
clocked at the lowest common denominator of CPU clock and DIMM clock.

Approved Configurations

(1) 1-CPU configurations:

 Select any one CPU listed in Table 6 on page 19.

(2) 2-CPU Configurations:

 Select two identical CPUs from any one of the rows of Table 6 on page 19.

Caveats

 You can select either one processor or two identical processors.


 The selection of 1 or 2 CPUs depends on the desired server functionality. See the following
sections:
— STEP 5 SELECT MEMORY, page 21 (memory mirroring section)
— Table 12 on page 33 (RAID support table)
— STEP 7 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs), page 39
— STEP 9 SELECT PCIe OPTION CARD(s), page 48
— ORDER GPU CARDS AND GPU POWER CABLES (OPTIONAL), page 58
 See NEBS Compliance, page 107 for complete information on Network Equipment Building
Standards (NEBS) support for a C240 M4 configured with 1 CPU or 2 CPUs.

20 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 5 SELECT MEMORY


The standard memory features are:

 DIMMs
— Clock speed: 2400 or 2133 MHz
— Ranks per DIMM: 1, 2, or 4
— Operational voltage: 1.2 V
— Registered ECC DDR4 DIMMs (RDIMMs) or load-reduced DIMMs (LRDIMMs)
 Memory is organized with four memory channels per CPU, with up to three DIMMs per
channel, as shown in Figure 7.

Figure 7 C240 M4 SFF Memory Organization

Slot 3

Slot 2

Slot 1
Slot 1

Slot 2

Slot 3

A1 A2 A3 E3 E2 E1

Chan A Chan E

B1 B2 B3 F3 F2 F1

Chan B Chan F

C1 C2 C3
CPU 1 CPU 2 G3 G2 G1

Chan C Chan G

D1 D2 D3 H3 H2 H1

Chan D Chan H

24 DIMMS
1.5 TB maximum memory (with 64 GB DIMMs)

4 memory channels per CPU,


up to 3 DIMMs per channel

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 21
CONFIGURING the SERVER

Select DIMMs and Memory Mirroring

Select the memory configuration and whether or not you want the memory mirroring option.
The available memory DIMMs and mirroring option are listed in Table 7.

NOTE: When memory mirroring is enabled, the memory subsystem simultaneously


writes identical data to two channels. If a memory read from one of the channels
returns incorrect data due to an uncorrectable memory error, the system
automatically retrieves the data from the other channel. A transient or soft error in
one channel does not affect the mirrored data, and operation continues unless there
is a simultaneous error in exactly the same location on a DIMM and its mirrored
DIMM. Memory mirroring reduces the amount of memory available to the operating
system by 50% because only one of the two populated channels provides data.

Table 7 Available DDR4 DIMMs

Ranks
Product ID (PID) PID Description Voltage
/DIMM

2400-MHz DIMM Options


UCS-ML-1X644RV-A 64GB DDR4-2400-MHz LRDIMM/PC4-19200/quad rank/x4 1.2 V 4
UCS-ML-1X324RV-A 32GB DDR4-2400-MHz LRDIMM/PC4-19200/quad rank/x4 1.2 V 4
UCS-MR-1X322RV-A 32GB DDR4-2400-MHz RDIMM/PC4-19200/dual rank/x4 1.2 V 2
UCS-MR-1X162RV-A 16GB DDR4-2400-MHz RDIMM/PC4-19200/dual rank/x4 1.2 V 2
UCS-MR-1X161RV-A 16GB DDR4-2400-MHz RDIMM/PC4-19200/single rank/x4 1.2 V 1
UCS-MR-1X081RV-A 8 GB DDR4-2400-MHz RDIMM/PC4-19200/single rank/x4 1.2 V 1
Memory Mirroring Option
N01-MMIRROR Memory mirroring option

Approved Configurations

(1) 1-CPU configuration without memory mirroring:

 Select from 1 to 12 DIMMs. Refer to Memory Population Rules, page 86, for more detailed
information.

(2) 1-CPU configuration with memory mirroring:

22 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

 Select 2, 4, 6, 8, or 12 identical DIMMs. The DIMMs will be placed by the factory as shown in
the following table.

Total CPU 1 DIMM Placement in Channels


Number (for identical dual-rank DIMMs for 3DPC or identical quad-rank DIMMs for 2DPC)
of
DIMMs Blue Slots Black Slots White Slots

2 (A1, B1) — —

4 (A1,B1); (C1,D1) — —

8 (A1,B1); (C1,D1) (A2,B2); (C2,D2)

12 (A1,B1); (C1,D1) (A2,B2); (C2,D2) (A3,B3); (C3,D3)

 Select the memory mirroring option (N01-MMIRROR) as shown in Table 7 on page 22.

(3) 2-CPU configuration without memory mirroring:

 Select from 1 to 12 DIMMs per CPU. Refer to Memory Population Rules, page 86, for more
detailed information.

(4) 2-CPU configuration with memory mirroring:

 Select 2, 4, 6, 8, or 12 identical DIMMs per CPU. The DIMMs will be placed by the factory as
shown in the following table.

Number CPU 1 DIMM Placement in Channels CPU 2 DIMM Placement in Channels


of (for identical dual-rank DIMMs for 3DPC or (for identical dual-rank DIMMs for 3DPC or
DIMMs identical quad-rank DIMMs for 2DPC) identical quad-rank DIMMs for 2DPC)
per CPU
Blue Slots Black Slots White Slots Blue Slots Black Slots White Slots
2 (A1, B1) — — (E1, F1) — —
4 (A1,B1); — — (E1,F1); — —
(C1,D1) (G1,H1)
8 (A1,B1); (A2,B2); — (E1,F1); (E2,F2); —
(C1,D1) (C2,D2) (G1,H1) (G2,H2)
12 (A1,B1); (A2,B2); (A3, B3) (E1,F1); (E2,F2); (E3,F3);
(C1,D1) (C2,D2) (C3, D3) (G1,H1) (G2,H2) (G3,H3)

 Select the memory mirroring option (N01-MMIRROR) as shown in Table 7 on page 22.

NOTE: System performance is optimized when the DIMM type and quantity are equal
for both CPUs, and when all channels are filled equally across the CPUs in the server.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 23
CONFIGURING the SERVER

Caveats

 System speed is dependent on how many DIMMs are populated per channel and the CPU
DIMM speed support. See Table 8 and Table 9 on page 25 for details.

Table 8 2133-MHz DIMM Memory Speeds with Different CPUs

1600-MHz Capable CPU 1866-MHz Capable CPU 2133-MHz Capable CPU


DIMM Speed DPC LRDIMM RDIMM LRDIMM RDIMM LRDIMM
RDIMM (8R, DR, SR)
(QR) (8R, DR, SR) (QR) (8R, DR, SR) (QR)

2133 DIMM 1DPC 1600 1600 1866 1866 2133 2133


2DPC 1600 1600 1866 1866 2133 2133
3DPC 1600 1600 1600 1600 1866 1866 
(32 GB RDIMMs and
16 GB DIMMs)
1600 
(64 GB TSV RDIMMs,
8 GB RDIMMs)

24 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 9 2400-MHz DIMM Memory Speeds with Different v4 CPUs

LRDIMM RDIMM  LRDIMM  RDIMM  RDIMM 


DIMM and CPU
DPC (QRx4) -  (2Rx4) -  (QRx4) -  (SRx4) -  (SRx4) - 
Frequencies
64 GB 32 GB 32 GB1 16 GB 8 GB

1.2 V 1.2 V 1.2 V 1.2 V 1.2 V

DIMM = 2400 MHz 1DPC 2400 MHz 2400 MHz 2400 MHz 2400 MHz 2400 MHz
CPU = 2400 MHz
2DPC1 2400 MHz 2400 MHz 2400 MHz 2400 MHz 2400 MHz

3DPC 2133 MHz 1866 MHz 2133 MHz 2133 MHz 2133 MHz

DIMM = 2400 MHz 1DPC 2133 MHz 2133 MHz 2133 MHz 2133 MHz 2133 MHz
CPU = 2133 MHz
2DPC 2133 MHz 2133 MHz 2133 MHz 2133 MHz 2133 MHz

3DPC 1866 MHz 1866 MHz 1866 MHz 1866 MHz 1600 MHz

DIMM = 2400 MHz 1DPC 1866 MHz 1866 MHz 1866 MHz 1866 MHz 1866 MHz
CPU = 1866 MHz
2DPC 1866 MHz 1866 MHz 1866 MHz 1866 MHz 1866 MHz

3DPC 1866 MHz 1600 MHz 1866 MHz 1600 MHz 1600 MHz

Notes . . .
1. When you mix 2400 MHz RDIMMs of different sizes (for example, 4x32GB + 4x16GB), the memory speed clocks
one step down to 2133 MHz.

 The C240 M4 server supports four different memory reliability, availability, and
serviceability (RAS) modes:
— Independent Channel Mode
— Mirrored Channel Mode
— Lockstep Channel Mode
 Below are the system level RAS Mode combination limitations:
— Mixing of Independent and Lockstep channel mode is not allowed per platform.
— Mixing of Non-Mirrored and Mirrored mode is not allowed per platform.
— Mixing of Lockstep and Mirrored mode is not allowed per platform.
 Do not mix RDIMMs with LRDIMMs
 Do not mix 64GB DDR4-2133-MHz TSV-RDIMMs with any other DIMMs
 Single-rank DIMMs can be mixed with dual-rank DIMMs in the same channel
 Do not mix quad-rank DIMMs with single- or dual-rank DIMMs in the same channel
 For best performance, observe the following:
— DIMMs with different timing parameters can be installed on different slots within the
same channel, but only timings that support the slowest DIMM will be applied to all.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 25
CONFIGURING the SERVER

As a consequence, faster DIMMs will be operated at timings supported by the slowest


DIMM populated.
— When one DIMM is used, it must be populated in DIMM slot 1 (farthest away from the
CPU) of a given channel.
— When single, dual or quad rank DIMMs are populated for 2DPC or 3DPC, always
populate the higher number rank DIMM first (starting from the farthest slot). For a
3DPC example, first populate with quad-rank DIMMs in the DIMM slot 1. Then
dual-rank DIMMs in the DIMM 2 slot. Then single-rank DIMMs in the DIMM 3slot.
 DIMMs for CPU 1 and CPU 2 (when populated) must always be configured identically.
 When using mirroring, DIMMs must be installed in identical pairs across paired DDR4 buses.
That is, mirrored pairs in channels A and B must be identical and pairs in channels C and D
must be identical. However, the DIMMs used in channels A and B can be different from those
in channels C and D.
 Memory mirroring reduces the amount of available memory by 50% (quantity of DIMMs must
be even for mirroring).
 Non-ECC DIMMs are not supported.
 Cisco memory from previous generation servers (DDR3) is not compatible with this server

For more information regarding memory, see CPUs and DIMMs, page 85.

26 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 6 SELECT RAID CONTROLLERS

RAID Controller Options (internal HDD/SSD support)

Embedded Software RAID


You can choose either the default embedded software RAID or the embedded software RAID 5
key upgrade.

 The default RAID configuration is embedded software RAID, which supports SATA HDDs (RAID
0, 1, 10).
 The embedded software RAID 5 key upgrade supports RAID 0, 1, 5, 10.

NOTE: The embedded software RAID in the Intel chipset hub is split into two, SATA
and sSATA (secondary SATA). They are seen as separate software RAID controllers and
are configurable separately. For more details, see Embedded SATA RAID: Two SATA
Controllers, page 95.

Cisco 12G SAS Modular RAID Controller


You can choose the Cisco 12G SAS RAID controller, which plugs into a dedicated RAID controller card slot.
This RAID controller supports RAID 0, 1, 10 (without the FBWC option) and supports RAID 0, 1, 10, 5, 6, 50,
60 (with the FBWC option).

NOTE: The number of RAID groups (virtual drives) supported per RAID controller is
as follows:
 Embedded RAID = 8
 Cisco 12G SAS Modular RAID controller = 64

NOTE: This controller can be ordered with several modular flash-backed write
cache (FBWC) options: 1 GB, 2 GB, or 4 GB. If the controller has a FBWC and you are
using a RAID configuration that uses striping (RAID 0, 10, 50, or 60), then the full list
of stripe sizes is available (8, 16, 32, 64, 128, 256, 512, or 1024 KB). If the controller
does not have a FBWC, then the only stripe size available is 64 KB.

SAS HBA (internal HDD/SSD/JBOD support)


Instead of a RAID controller, you can choose a SAS HBA for internal JBOD drive connectivity
(non-RAID):

 Cisco 12 Gbps Modular SAS HBA, which plugs into a dedicated RAID controller slot.

SAS HBA (external JBOD support)


In addition to a RAID controller or JBOD controller for internal drives, you can choose the
following SAS HBA for external JBOD drive connectivity (non-RAID):

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 27
CONFIGURING the SERVER

 Cisco 9300-8e 12G SAS HBA (provides 8 SAS ports for external JBOD connectivity).

NOTE: The UCSC-C240-M4SX (24-drive server) and UCSC-C240-M4S2 (16-drive server)


do not support the default embedded software RAID or the embedded software RAID
5 key upgrade (UCSC-SWRAID5), which is installed on the motherboard. The only
drive controller support available for the 24-drive or 16-drive versions is through the
Cisco 12G SAS Modular RAID controller (provides RAID control) or the Cisco 12 Gbps
Modular SAS HBA (provides JBOD control) for internal drives. The only RAID support
available for the 8-drive version is through the Cisco 12G SAS Modular RAID controller
for internal drives, the Cisco 12 Gbps Modular SAS HBA, embedded software RAID, or
the embedded software RAID 5 key upgrade.

RAID Volumes and Groups


When creating each RAID volume, follow these guidelines:

 Use the same capacity for each drive in each RAID volume
 For embedded software RAID or the embedded software RAID 5 key upgrade:
— Use only SATA HDDs
— Embedded software RAID has two ports and each port can control 4 drives, for 8
drives total.
— Each set of 4 SATA HDDs for a port must be in separate RAID volumes.
— You cannot mix drives across ports to create a RAID volume.
— For more details, see Embedded SATA RAID: Two SATA Controllers, page 95.
 For the Cisco 12G SAS modular RAID controller upgrade:
— Use either all SAS HDDs, or all SAS SSDs, or all SATA SSDs in each RAID volume

The number of RAID groups (virtual drives) supported per RAID controller is as follows:

 Embedded RAID = 8
 Cisco 12G SAS Modular RAID controller = 64

Select Controller Options

Select as follows (these choices are dependent on the backplane used (24-drive, 16-drive, or
8-drive backplane)):

 For a 24-drive backplane system, select one of the following:


— Cisco 12G SAS Modular RAID controller from Table 11 on page 31, or
— Cisco 9300-8E 12G SAS HBA option (JBOD support only for external drives) from
Table 11 on page 31, or
— Mixed controllers:

28 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

• One Cisco 12G SAS Modular RAID controller or one Cisco 12 Gbps Modular SAS HBA
from Table 11 on page 31, and
• One or two Cisco 9300-8E 12G SAS HBAs (JBOD support only for external drives)
from Table 11 on page 31
— Dual HBAs:
• Two Cisco 9300-8E 12G SAS HBAs (JBOD support only for external drives) from
Table 11 on page 31

Select an appropriate optional RAID configuration listed in Table 11 on page 31 (note


that the Cisco 12 Gbps Modular SAS HBA supports JBOD only and is not a RAID
controller).

 For a 16-drive backplane system, select one of the following:


— Cisco 12G SAS Modular RAID controller or the Cisco 12 Gbps Modular SAS HBA from
Table 11 on page 31, or
— Cisco 9300-8E 12G SAS HBA upgrade option from Table 11 on page 31, or
— Mixed controllers:
• One Cisco 12G SAS Modular RAID controller or the Cisco 12 Gbps Modular SAS HBA
from Table 11 on page 31, and
• One or two Cisco 9300-8E 12G SAS HBAs (JBOD support only for external drives)
from Table 11 on page 31
— Dual HBAs:
• Two Cisco 9300-8E 12G SAS HBAs (JBOD support only for external drives) from
Table 11 on page 31

Select an appropriate optional RAID configuration listed in Table 11 on page 31.

 For an 8-drive backplane system, select one of the following:


— Embedded software RAID (this is the default if no other selection is made), or
— Embedded software RAID 5 key upgrade option for internal drives (see Table 10), or
— Cisco 12G SAS modular RAID controller or the Cisco 12 Gbps Modular SAS HBA (see
Table 11 on page 31), or
— Cisco 9300-8E 12G SAS HBA upgrade option from Table 11 on page 31, or
— Mixed controllers:
• One Cisco 12G SAS modular RAID controller or the Cisco 12 Gbps Modular SAS
HBA, and
• One or two Cisco 9300-8E 12G SAS HBAs for external SAS JBOD/enclosure
connectivity support (see Table 11 on page 31).
— Dual HBAs:
• Two Cisco 9300-8E 12G SAS HBAs (JBOD support only for external drives) from
Table 11 on page 31

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 29
CONFIGURING the SERVER

NOTE: Mixing the Cisco 9300-8E 12G SAS HBA in the same server as the Cisco 12
Gbps Modular SAS HBA requires the following firmware levels:
 Cisco IMC/BIOS 2.0(8) or later
 Cisco UCS Manager 2.2(6) or later (for integrated servers only)

For the Cisco 12G SAS modular RAID controller upgrade, select an appropriate optional RAID
configuration listed in Table 11 on page 31

NOTE: The Cisco 12G SAS modular RAID controller can be ordered with or without an
optional FBWC (cache). The FBWC option backs up the RAID controller write cache.
The FBWC is available in 1 GB, 2 GB, or 4 GB sizes. See Table 11 on page 31 for
details.

NOTE: For all valid combinations of embedded RAID and internal/external controller
combinations, see RAID Details, page 91.

Table 10 shows the product ID for the C240 M4 server entry-level RAID solution. This RAID option is
accomplished with embedded software that supports a limited number of drives, operating systems, and
virtualized environments. For a more comprehensive enterprise RAID solution, choose the Cisco 12G SAS
modular RAID controller listed in Table 11.

30 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 10 Entry Level RAID Solution

Product ID (PID) PID Description

Embedded Software RAID 5 Key Upgrade

UCSC-SWRAID5 Embedded Software RAID 5 key upgrade, consisting of a storage controller unit
(SCU) module that plugs into a 2-pin header on the motherboard, supporting
up to eight internal SATA only HDDs. See Embedded SATA RAID: Two SATA
Controllers, page 95. This module upgrades the embedded software RAID
controller option to add RAID 5. This option supports RAID 0, 1, 10, 5 and
operates at 6 Gbps. Operating systems supported are Windows and Linux only
(no VMware support). On M4 platforms, SWRAID is not supported for RHEL 7.3
and above.
VMware ESX/ESXi or any other virtualized environments (such as Hyper-V, Xen,
or KVM) are not supported for use with the embedded software RAID
controller.

Table 11 Hardware Controller Options

Product ID (PID) PID Description


Controllers for Internal Drives
Note that if the following Cisco 12G SAS Modular RAID controller or Cisco 12Gbps Modular SAS HBA
controller is selected, it is factory-installed in the dedicated internal slot.
UCSC-MRAID12G Cisco 12G SAS Modular RAID Controller
 Supports up to 24 internal SAS HDDs and SAS/SATA SSDs
 Supports JBOD, RAID 0, 1, 10 (with no FBWC option chosen) and has the
ability to also support RAID 5, 6 if a Flash-Backed Write cache upgrade is
chosen (shown below in this table)
 SED drives are compatible with only with the combination of a
UCSC-MRAID12G RAID controller along with one of the flash-back write
cache modules (UCSC-MRAID12G-1GB, UCSC-MRAID12G-2GB, or
UCSC-MRAID12G-4GB).
 For all self-encrypting drives (SED), standalone Management (CIMC) is
supported for configuring and managing local keys (UCSM is not
supported). For now, SED drives are managed with local key management
only. In the future, third-party key management will be supported.
UCSC-SAS12GHBA Cisco 12 Gbps Modular SAS HBA
 Supports up to 24 internal SAS HDDs and SAS/SATA SSDs
 Supports JBOD mode only (no RAID functionality. Ideal for SDS (Software
Defined Storage) applications. It is also ideal for environments demanding
the highest IOPs (for external SSD attach), where a RAID controller can be
an I/O bottleneck.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 31
CONFIGURING the SERVER

Table 11 Hardware Controller Options (continued)

Product ID (PID) PID Description


UCSC-PSAS12GHBA1 Cisco 12 Gbps Modular SAS HBA
 Supports up to 24 internal SAS HDDs and SAS/SATA SSDs
 Supports JBOD mode only (no RAID functionality. Ideal for SDS (Software
Defined Storage) applications. It is also ideal for environments demanding
the highest IOPs (for external SSD attach), where a RAID controller can be
an I/O bottleneck.
 Same functionality as UCSC-SAS12GHBA, but vendor is Microsemi
Flash-Backed Write Cache (FBWC) Upgrade Options for Cisco 12G SAS Modular RAID controller
UCSC-MRAID12G-1GB 1 GB FBWC, which includes a 1 GB MB memory plus a SuperCap for write cache
backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60.
UCSC-MRAID12G-2GB 2 GB FBWC, which includes a 2 GB MB memory plus a SuperCap for write cache
backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60.
UCSC-MRAID12G-4GB 4 GB FBWC, which includes a 4 GB MB memory plus a SuperCap for write cache
backup. Supports JBOD, RAID 0, 1, 10, 5, 6, 50, and 60.
SAS HBA for External JBOD Attach
Two SFF8644 mini-SAS HD connectors on this card are accessible at the rear of the chassis.
UCSC-SAS9300-8E Cisco 12G 9300-8e 12G SAS HBA for external JBOD attach
 Supports external JBOD using x8 wide SAS ports

NOTE: For Cisco 9300-8e 12G SAS HBA external drive enclosure
support, see the enclosure section of the compatibility list at the
following link:

https://www.broadcom.com/support/interop-compatibility

Customers should contact their storage vendor for technical support


related to external JBOD enclosures.

RAID Configuration Options (not available for Cisco 12 Gbps Modular SAS HBA or embedded software RAID)
R2XX-SRAID0 Enable Single Disk Raid 0 Setting

R2XX-RAID0 Factory preconfigured RAID striping option


Enable RAID 0 Setting. Requires a minimum of one hard drive.

R2XX-RAID1 Factory preconfigured RAID mirroring option


Enable RAID 1 Setting. Requires exactly two drives with the same size, speed,
capacity.
R2XX-RAID5 Factory preconfigured RAID option
Enable RAID 5 Setting. Requires a minimum of three drives of the same size,
speed, capacity.
R2XX-RAID6 Factory preconfigured RAID option
Enable RAID 6 Setting. Requires a minimum of four drives of the same size,
speed, capacity.

32 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Notes . . .
1. Supports higher IOPS

NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are
supported for selected controllers as shown in Table 11

Approved Configurations

The C240 M4 SFF server can be ordered as a UCSC-C240-M4SX (24-drive backplane with SAS
expander), a UCSC-C240-M4S2 (16-drive backplane with SAS expander), or UCSC-C240-M4S
(8-drive backplane with no SAS expander).

 The embedded software RAID (default) supports up to 8 internal SATA HDDs with RAID 0, 1,
10 support.
 The embedded software RAID 5 upgrade key option supports up to 8 internal SATA HDDs with
RAID 0, 1, 10, 5 support.
 The Cisco 12G SAS Modular RAID controller upgrade option supports up to 24 internal drives
with up to RAID 0, 1, 10, 5, 6, 50, 60 support (with FBWC option chosen).
 The Cisco 12 Gbps Modular SAS HBA supports up to 24 internal drives with JBOD support.
 The Cisco 9300-8e 12G SAS HBA supports up to 8 external SAS ports with JBOD support.

See Table 12 for a summary of the supported controller configuration options.

Table 12 Supported Controller Configurations

Cisco 12G SAS Modular RAID


Controller or
Cisco 12 Gbps Modular SAS
HBA2 Cisco Internal
# Embedded (only one can be installed at 9300-8E # Drives Drive
Server RAID Support
CPUs RAID1 a time) 12G SAS Supported Types
HBA3 Allowed
Cisco 12G SAS Cisco 12G
Modular RAID Modular SAS
Controller HBA

C240 0,1,10,5,6,50,60
M4 Installed Installed (for 12G SAS) or SAS HDDs,
Not Card 24
SFF 1 in dedicated in dedicated JBOD SAS/SATA
allowed absent internal
24 slot slot (for Modular SAS SSDs
HDD HBA)
Only one of the above can
be installed at a time

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 33
CONFIGURING the SERVER

Table 12 Supported Controller Configurations (continued)

Cisco 12G SAS Modular RAID


Controller or
Cisco 12 Gbps Modular SAS
HBA2 Cisco Internal
# Embedded (only one can be installed at 9300-8E # Drives Drive
Server RAID Support
CPUs RAID1 a time) 12G SAS Supported Types
HBA3 Allowed
Cisco 12G SAS Cisco 12G
Modular RAID Modular SAS
Controller HBA

C240 0 internal
M4 Installed 1024
Not
SFF 1 Card absent Card absent slot 1, 2, external JBOD None
allowed
24 or 3
HDD

24 0,1,10,5,6,50,60
C240
internal (for 12G SAS) or
M4 Installed Installed Installed SAS HDDs,
Not 1024 JBOD
SFF 1 in dedicated in dedicated slot 1, 2, SAS/SATA
allowed external (for Modular SAS
24 slot slot or 3 SSDs
HBA) and JBOD
HDD
(for 9300)
Only one of the above can
be installed at a time
C240 0,1,10,5,6,50,60
M4 Installed Installed (for 12G SAS) or SAS HDDs,
Not Card 24
SFF 2 in dedicated in dedicated JBOD SAS/SATA
allowed absent internal
24 slot slot (for Modular SAS SSDs
HDD HBA)
Only one of the above can
be installed at a time
C240
M4 0 internal
Not Installed
SFF 2 Card absent Card absent 1024 JBOD None
allowed any slot
24 external
HDD
0,1,10,5,6,50,60
C240
24 (for 12G SAS) or
M4 Installed Installed SAS HDDs,
Not Installed internal JBOD
SFF 2 in dedicated in dedicated SAS/SATA
allowed any slot 1024 (for Modular SAS
24 slot slot SSDs
external HBA) and JBOD
HDD
(for 9300)
Only one of the above can
be installed at a time
C240 0,1,10,5,6,50,60
M4 Installed Installed (for 12G SAS) or SAS HDDs,
Not Card 16
SFF 1 in dedicated in dedicated JBOD SAS/SATA
allowed absent internal
16 slot slot (for Modular SAS SSDs
HDD HBA)

34 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 12 Supported Controller Configurations (continued)

Cisco 12G SAS Modular RAID


Controller or
Cisco 12 Gbps Modular SAS
HBA2 Cisco Internal
# Embedded (only one can be installed at 9300-8E # Drives Drive
Server RAID Support
CPUs RAID1 a time) 12G SAS Supported Types
HBA3 Allowed
Cisco 12G SAS Cisco 12G
Modular RAID Modular SAS
Controller HBA

Only one of the above can


be installed at a time
C240
M4 Installed 0 internal
Not
SFF 1 Card absent Card absent slot 1, 2, 1024 JBOD None
allowed
16 or 3 external
HDD
0,1,10,5,6,50,60
C240
16 (for 12G SAS) or
M4 Installed Installed Installed SAS HDDs,
Not internal JBOD
SFF 1 in dedicated in dedicated slot 1, 2, SAS/SATA
allowed 1024 (for Modular SAS
16 slot slot or 3 SSDs
external HBA) and JBOD
HDD
(for 9300)
Only one of the above can
be installed at a time
C240 0,1,10,5,6,50,60
M4 Installed Installed (for 12G SAS) or SAS HDDs,
Not Card 16
SFF 2 in dedicated in dedicated JBOD SAS/SATA
allowed absent internal
16 slot slot (for Modular SAS SSDs
HDD HBA)
Only one of the above can
be installed at a time
C240
M4 0 internal
Not Installed
SFF 2 Card absent Card absent 1024 JBOD None
allowed any slot
16 external
HDD
0,1,10,5,6,50,60
C240
16 (for 12G SAS) or
M4 Installed Installed SAS HDDs,
Not Installed internal JBOD
SFF 2 in dedicated in dedicated SAS/SATA
allowed any slot 1024 (for Modular SAS
16 slot slot SSDs
external HBA) and JBOD
HDD
(for 9300)
Only one of the above can
be installed at a time

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 35
CONFIGURING the SERVER

Table 12 Supported Controller Configurations (continued)

Cisco 12G SAS Modular RAID


Controller or
Cisco 12 Gbps Modular SAS
HBA2 Cisco Internal
# Embedded (only one can be installed at 9300-8E # Drives Drive
Server RAID Support
CPUs RAID1 a time) 12G SAS Supported Types
HBA3 Allowed
Cisco 12G SAS Cisco 12G
Modular RAID Modular SAS
Controller HBA

0, 1, 10
C240
(default) or
M4 Not SATA
1 Enabled Not allowed Not allowed 8 internal 0, 1, 10, 5
SFF allowed HDDs
(RAID 5 key
8 HDD
upgrade)
0,1,10,5,6,50,60
C240
Installed Installed (for 12G SAS) or SAS HDDs,
M4 Not Card
1 in dedicated in dedicated 8 internal JBOD SAS/SATA
SFF allowed absent
slot slot (for Modular SAS SSDs
8 HDD
HBA)
Only one of the above can
be installed at a time
C240
Installed 0 internal
M4 Not
1 Card absent Card absent slot 1, 2, 1024 JBOD None
SFF allowed
or 3 external
8 HDD
0,1,10,5,6,50,60
C240 (for 12G SAS) or
Installed Installed Installed 8 internal SAS HDDs,
M4 Not JBOD
1 in dedicated in dedicated slot 1, 2, 1024 SAS/SATA
SFF allowed (for Modular SAS
slot slot or 3 external SSDs
8 HDD HBA) and JBOD
(for 9300)
Only one of the above can
be installed at a time
0, 1, 10
C240
(default) or
M4 Not 8 internal SATA
2 Enabled Not allowed Not allowed 0, 1, 10, 5
SFF allowed SATA only HDDs
(RAID 5 key
8 HDD
upgrade)
0,1,10,5,6,50,60
C240
Installed Installed (for 12G SAS) or SAS HDDs,
M4 Not Card
2 in dedicated in dedicated 8 internal JBOD SAS/SATA
SFF allowed absent
slot slot (for Modular SAS SSDs
8 HDD
HBA)
Only one of the above can
be installed at a time

36 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 12 Supported Controller Configurations (continued)

Cisco 12G SAS Modular RAID


Controller or
Cisco 12 Gbps Modular SAS
HBA2 Cisco Internal
# Embedded (only one can be installed at 9300-8E # Drives Drive
Server RAID Support
CPUs RAID1 a time) 12G SAS Supported Types
HBA3 Allowed
Cisco 12G SAS Cisco 12G
Modular RAID Modular SAS
Controller HBA

C240
0 internal
M4 Not Installed
2 Card absent Card absent 1024 JBOD None
SFF allowed any slot
external
8 HDD
0,1,10,5,6,50,60
C240 (for 12G SAS) or
Installed Installed 8 internal SAS HDDs,
M4 Not Installed JBOD
2 in dedicated in dedicated 1024 SAS/SATA
SFF allowed any slot (for Modular SAS
slot slot external SSDs
8 HDD HBA) and JBOD
(for 9300)
Only one of the above can
be installed at a time

Notes . . .
1. Embedded RAID is only compatible with the 8 HDD backplane. It cannot be used with the 16 or 24 HDD
backplane, because those backplanes have SAS extenders.
2. If you want to boot from a device other than the Cisco 12G SAS Modular RAID controller or Cisco 12 Gbps
Modular SAS HBA, you can leave the card installed. Just disable the OPROM for its slot, and the system will boot
even with the card installed.
3. External drive PCIe controller card is the Cisco 12G 9300-8e 12G SAS HBA and can be installed simultaneously
with the Cisco 12G SAS Modular RAID controller card or Cisco 12 Gbps Modular SAS HBA.

Caveats

 A maximum of two Cisco 9300-8e 12G SAS HBAs can be installed in any slot (depending on
the number of CPUs installed). The system can also support combinations of one Cisco
9300-8e 12G SAS HBA and a Storage Accelerator card along with either a Cisco 12G SAS
Modular RAID Controller, or a Cisco 12 Gbps Modular SAS HBA.
 For the Cisco 12G SAS Modular RAID controller you can choose an optional RAID configuration
(up to RAID 0, 1, 10, 5, 6, 50, 60 if optional FBWC option is chosen), which is preconfigured
at the factory. The RAID level you choose must be an available RAID choice for the controller
selected. RAID levels 50 and 60 are supported, although they are not available as
configuration options. It can also be combined with AHCI support for internal SSDs (SATA
Boot Drives) in 24-drive systems (only) and cannot be mixed with Embedded RAID.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 37
CONFIGURING the SERVER

 A system supports up to 8 SATA-only drives through the embedded software RAID controller
if no Cisco 12G SAS Modular RAID controller is chosen.

NOTE: For more important information regarding RAID support, see RAID Details,
page 91 and RAID Option ROM (OPROM) Settings, page 92.

38 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 7 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES


(SSDs)
The standard disk drive features are:

 2.5-inch small form factor


 Hot-pluggable
 Drives come mounted in sleds

NOTE: 
All SED HDDs are FIPs 140-2 compliant
SED SSDs (10X endurance) are FIPS 140-2 compliant
SED SSDs (3X and 1X endurance) are not FIPS 140-2 compliant

Select Drives

The available HDDs and SSDs are listed in Table 13.

Table 13 Available Hot-Pluggable Sled-Mounted HDDs and SSDs

Drive
Product ID (PID) PID Description Capacity
Type
HDDs (15K RPM)
UCS-HD900G15K12G 900 GB 12G SAS 15K RPM SFF HDD SAS 900 GB
UCS-HD600G15K12G 600 GB 12G SAS 15K RPM SFF HDD SAS 600 GB
UCS-HD450G15K12G 450 GB 12G SAS 15K RPM SFF HDD SAS 450 GB
UCS-HD300G15K12G 300 GB 12G SAS 15K RPM SFF HDD SAS 300 GB
HDDs (10K RPM)
UCS-HD18TB10KS4K1 1.8 TB 12 Gbps SAS 10K RPM SFF HDD (4K sector format) SAS 1.8 TB
UCS-HD12TB10K12G 1.2 TB 12G SAS 10K RPM SFF HDD SAS 1.2 TB
UCS-HD900G10K12G 900 GB 12G SAS 10K RPM SFF HDD SAS 900 GB
UCS-HD600G10K12G 600 GB 12G SAS 10K RPM SFF HDD SAS 600 GB
UCS-HD300G10K12G 300 GB 12G SAS 10K RPM SFF HDD SAS 300 GB
HDDs (7.2K RPM)
UCS-HD2T7K12G 2 TB 12G SAS 7.2K RPM SFF HDD SAS 2 TB
UCS-HD1T7K12G 1 TB 12G SAS 7.2K RPM SFF HDD SAS 1 TB
UCS-HD1T7K6GA 1 TB 6G SATA 7.2K RPM SFF HDD SATA 1 TB

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 39
CONFIGURING the SERVER

Table 13 Available Hot-Pluggable Sled-Mounted HDDs and SSDs (continued)

Drive
Product ID (PID) PID Description Capacity
Type
SSDs
Enterprise Performance SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes per day))2
UCS-SD16TB12S4-EP 1.6 TB 2.5 inch Enterprise Performance 12G SAS SSD (10X DWPD) SAS 1.6 TB
(Sandisk Lightning Ascend)
UCS-SD400G12S4-EP 400 GB 2.5 inch Enterprise Performance 12G SAS SSD (10X DWPD) SAS 400 GB
(Sandisk Lightning Ascend)
UCS-SD800G12S4-EP 800 GB 2.5 inch Enterprise Performance 12G SAS SSD (10X DWPD) SAS 800 GB
(Samsung 1635))
UCS-SD16TSASS3-EP 1.6TB 2.5 inch Enterprise performance 12G SAS SSD(3X DWPD) SAS 1.6 TB
UCS-SD800GSAS3-EP 800GB 2.5 inch Enterprise performance 12G SAS SSD(3X DWPD SAS 800 GB
UCS-SD32TSASS3-EP 3.2TB 2.5 inch Enterprise performance 12G SAS SSD(3X DWPD) SAS 3.2 TB
UCS-SD400GSAS3-EP 400GB 2.5 inch Enterprise performance 12G SAS SSD(3X DWPD) SAS 400 GB
UCS-SD480GIS3-EP 480GB 2.5in Enterprise performance 6G SATA SSD(3X endurance) SATA 400 GB
UCS-SD960GIS3-EP 960GB 2.5in Enterprise performance 6G SATA SSD(3X endurance) SATA 960 GB
UCS-SD19TIS3-EP 1.9TB 2.5in Enterprise performance 6G SATA SSD(3X endurance) SATA 1.9 TB
Enterprise Value SSDs (Low endurance, supports up to 1X DWPD (drive writes per day))3
UCS-SD38TBKS4-EV 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863) SATA 3.8 TB
UCS-SD19TBKSS-EV 1.9 TB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863) SATA 1.9 TB
UCS-SD16TBKS4-EV 1.6 TB 2.5 inch Enterprise Value 6G SATA SSD (Intel 3510) SATA 1.6 TB
UCS-SD960GIKS4-EV 960GB 2.5 inch Enterprise Value 6G SATA SSD SATA 900 GB
UCS-SD480GBKSS-EV 480 GB 2.5 in Enterprise Value 6G SATA SSD (Samsung PM863) SATA 480 GB
UCS-SD480GBKS4-EV 480 GB 2.5 inch Enterprise Value 6G SATA SSD (Intel 3510) SATA 480 GB
UCS-SD120GBKS4-EV 120 GB 2.5 inch Enterprise Value 6G SATA SSD (Intel 3510) SATA 120 GB
UCS-SD960GBKS4-EV 960 GB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863) SATA 960 GB
UCS-SD240GBKS4-EV 240 GB 2.5 inch Enterprise Value 6G SATA SSD (Samsung PM863) SATA 240 GB
UCS-SD120GBMS4-EV 120 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100 MAX) SATA 120 GB
UCS-SD240GBMS4-EV 240 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100 PRO) SATA 240 GB
UCS-SD480GBMS4-EV 480 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100 PRO) SATA 480 GB
UCS-SD960GBMS4-EV 960 GB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100 PRO) SATA 960 GB
UCS-SD16TBMS4-EV 1.6 TB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100 MAX) SATA 1.6 TB
UCS-SD19TBMS4-EV 1.9 TB 2.5 inch Enterprise Value 6G SATA SSD Micron 5100 ECO) SATA 1.9 TB
UCS-SD38TBMS4-EV 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100 ECO) SATA 3.8 TB
UCS-SD76TBMS4-EV 7.6 TB 2.5 inch Enterprise Value 6G SATA SSD (Micron 5100 ECO) SATA 7.6 TB
UCS-SD480GSAS-EV 480 GB 2.5 inch Enterprise Value 12G SAS SSD (Toshiba PX05) SAS 480 GB
UCS-SD480GBIS6-EV 480GB 2.5 inch Enterprise Value 6G SATA SSD SATA 480 GB

40 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 13 Available Hot-Pluggable Sled-Mounted HDDs and SSDs (continued)

Drive
Product ID (PID) PID Description Capacity
Type
UCS-SD960GBIS6-EV 960GB 2.5 inch Enterprise Value 6G SATA SSD SATA 960 GB
UCS-SD38TBIS6-EV 3.8TB 2.5 inch Enterprise Value 6G SATA SSD SATA 3.8 TB
UCS-SD38TSAS-EV 3.8TB 2.5 inch Enterprise Value 12G SAS SSD SAS 3.8 TB
UCS-SD19TSAS-EV 1.9TB 2.5 inch Enterprise Value 12G SAS SSD SAS 1.9 TB
UCS-SD960GSAS-EV 960GB 2.5 inch Enterprise Value 12G SAS SSD SAS 960 GB
NOTE: Cisco uses solid state drives from a number of vendors. All solid state drives are subject to physical write limits
and have varying maximum usage limitation specifications set by the manufacturer. Cisco will not replace any solid state
drives that have exceeded any maximum usage specifications set by Cisco or the manufacturer, as determined solely by
Cisco

Notes . . .
1. UCS Rack Servers require minimum firmware version 2.0(4) to support 4K sector size drives.
Operating Systems supported on 4k sector size drives is as follows:
- Windows: Windows 8 and later and Windows Server 2012 and later
- Linux: RHEL 6.5/6.6/6.7/7.0/7.2/SLES 11 SP3 and SLES 12
- VMware supports 4k native drives starting from ESXi 6.7; All earlier versions of ESXi support 512e format drives only
UEFI Mode must be used when booting from 4K sector size drives, legacy mode is not supported.
Ensure that 4K sector size and 512 byte sector size drives are not mixed in the same RAID volume.
2. Targeted for write centric IO applications. Supports endurance of 10 or 3 DWPD (drive writes per day). Target
applications are caching, online transaction processing (OLTP), data warehousing, and virtual desktop
infrastructure (VDI).
3. Targeted for read centric IO applications. Supports endurance of 1 DWPD (drive write per day). Target applications
are boot, streaming media, and collaboration.

The available boot drives are listed in Table 14.

Table 14 Available Boot Drives (mounted inside chassis)

Drive
Product ID (PID) PID Description Capacity
Type

Boot Drives
UCS-SD16TBKS4-EB 1.6 TB 2.5 inch Enterprise Value 6G SATA SSD (boot) SATA 1.6 TB
UCS-SD480GBKS4-EB 480 GB 2.5 inch Enterprise Value 6G SATA SSD (boot) SATA 480 GB
UCS-SD240GBKS4-EB 240 GB 2.5 inch Enterprise Value 6G SATA SSD (boot) SATA 240 GB
UCS-SD120GBKS4-EB 120 GB 2.5 inch Enterprise Value 6G SATA SSD (boot) SATA 120 GB

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 41
CONFIGURING the SERVER

The available plug-in PCIe SSD drives and kits are listed in Table 15.

Table 15 Available Plug-In NVMe SFF 2.5” drives1

Product ID (PID) PID Description Drive Type Capacity

NVMe SFF 2.5” drives


UCSC-NVMEM4-H800 Cisco 2.5in U.2 800GB HGST SN200 NVMe. High NVMe SSD 800 GB
Endurance SSD
UCSC-NVMEM4-H1600 Cisco 2.5in U.2 1.6TB HGST SN200 NVMe. High NVMe SSD 1.6 TB
Endurance SSD
C240 M4 PCIE SSD Interposer board + cable kit (24 drive configuration)2
UCSC-IPSSD-240M4B
C240 M4 PCIE SSD Interposer board + cable kit (8 or 16 drive configurations)2
UCSC-IP-SSD-240M4

Notes . . .
1. If you choose one or two PCIe SSD drives, drive slots 1 and 2 at the front of the chassis are reserved for these
drives (see Figure 2 on page 6 for drive slot numbering).
2. You must order an interposer board and cable kit if you order an NVMe SFF 2.5” drive. A single interposer board
and cable kit supports up to two NVMe SFF 2.5” drives.

Approved Configurations

(1) For systems with an 8-drive backplane:

 The embedded software RAID default supports up to 8 internal SATA HDDs with RAID 0, 1, 10
support.
 The embedded software RAID 5 upgrade key option supports up to 8 internal SATA HDDs with
RAID 0, 1, 10, 5 support.

(2) For systems with a 16-drive backplane:

 The Cisco 12G SAS Modular RAID controller upgrade option supports up to 16 internal SAS
HDDs and SAS/SATA SSDs.
— The Cisco 12G SAS Modular RAID controller with no FBWC option (supports JBOD,
RAID 0, 1, 10)
— The Cisco 12G SAS Modular RAID controller with FBWC option (supports JBOD, RAID
0, 1, 10, 5, 6, 50, and 60)

(3) For systems with a 24-drive backplane:

 The Cisco 12G SAS Modular RAID controller upgrade option supports up to 24 internal SAS
HDDs and SAS/SATA SSDs.
 The Cisco 12 Gbps Modular SAS HBA upgrade option supports up to 24 internal SAS HDDs and
SAS/SATA SSDs.

42 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

NOTE: If you selected a Cisco 12G SAS Modular RAID controller for internal
HDDs/SSDs, you have the following options:
 Cisco 12G SAS Modular RAID controller with no FBWC option (supports JBOD,
RAID 0, 1, 10)
 Cisco 12G SAS Modular RAID controller with FBWC option (supports JBOD, and
RAID up to 0, 1, 10, 5, 6, 50, and 60)
 For either option, select up to 8, 16, or 24 SAS HDDs or SAS/SATA SSDs, as
appropriate listed in Table 13 on page 39.
 See SELECT RAID CONTROLLERS, page 27 for more details.

(4) Systems Using Boot Drives

 If you are configuring a 24-drive backplane system that uses SATA SSD boot drives, choose up
to two identical boot drives from Table 14 on page 41.

NOTE: The two SATA SSD boot drives are supported only on the 24-drive backplane
chassis version. The drives are managed in AHCI mode, using OS-based software
RAID. These two drives, managed with OS software RAID, can coexist with drives
managed by either embedded RAID, the Cisco 12 Gbps Modular SAS HBA, or a Cisco
UCS 12G SAS modular RAID controller. UCSM supports configuration of the boot drives
in RAID 1 mode, in conjunction with the RAID methods for the other drives previously
mentioned. The drives are plugged directly into the SATA boot drive connectors on
riser card 1 (option 3). The internal boot drives come mounted to their own unique
internal drive sleds, which are different from the front loading hot-swappable drive
sleds. See Riser Card Configuration and Options, page 93.

(5) Systems Using Plug-in NVMe SFF 2.5” drives

Systems using NVMe SFF 2.5” drives are controlled through the PCIe bus. If you choose one or
two NVMe SFF 2.5” drives, they must be plugged into only drive slots 1 and 2 in the front of the
chassis. Additionally, any system implementing NVMe SFF 2.5” drives must be ordered with two
CPUs.

Caveats

 You can choose only SATA HDDs when using embedded software RAID.
 You can choose only SAS HDDs or SAS/SATA SSDs when using the Cisco 12G SAS Modular RAID
Controller or Cisco 12 Gbps Modular SAS HBA.
 You can mix HDDs and SSDs as long as you keep all HDDs in their own RAID volume and all
SSDs in their own RAID volume.
 You can mix SAS HDDs and SAS/SATA SSDs when using the Cisco 12G SAS Modular RAID
Controller or Cisco 12 Gbps Modular SAS HBA.
 If you order one or two boot drives, you can order a maximum of one GPU and it must be
installed in Riser 2 (UCSC-PCI-2-C240M4) slot 5.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 43
CONFIGURING the SERVER

 If you order any NVMe SFF 2.5” drives, you must also order two CPUs.
 A maximum of two NVMe SFF 2.5” drives can be ordered.
 NVMe SFF 2.5" drives are bootable only in standalone mode with IMC software and in UEFI
mode only.
 NVMe HHHL drives are not bootable.
 NVMe SFF 2.5” drives cannot be controlled with a RAID controller.
 SED drives (see SELECT SED HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs),
page 45) can be mixed with the non-SED drives in Table 13 on page 39.

Disk performance and IO characterization is found at:

http://www.cisco.com/c/en/us/products/servers-unified-computing/ucs-c-series-rack-servers/whitepaper
-c11-738090.html

44 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 8 SELECT SED HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES
(SSDs)
The standard disk drive features are:

 Self-encrypting drives (SED)


 2.5-inch small form factor
 Hot-pluggable
 Drives come mounted in sleds

NOTE:
All SED HDDs are FIPs 140-2 compliant
SED SSDs (10X endurance) are FIPS 140-2 compliant
SED SSDs (3X and 1X endurance) are not FIPS 140-2 compliant

Select Drives

The available HDDs and SSDs are listed in Table 13.

Table 16 Available Hot-Pluggable Self-Encrypting Sled-Mounted HDDs and SSDs

Drive
Product ID (PID) PID Description1 Capacity
Type
HDDs (15K RPM)
UCS-HD600G15K9 600 GB 12G SAS 15K RPM SFF HDD (SED) SAS 600 GB
HDDs (10K RPM)
UCS-HD18G10K92 1.8 TB 12G SAS 10K RPM SFF HDD (SED), (4K sector format)) SAS 1.8 TB
UCS-HD12G10K9 1.2 TB 12G SAS 10K RPM SFF HDD (SED) SAS 1.2 TB
UCS-HD300G10K9 300 GB 12G SAS 10K RPM SFF HDD (SED) SAS 300 GB
SSDs
Enterprise Performance SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes per day))2
UCS-SD16TBEK9 1.6 TB Enterprise performance SAS SSD (10X DWPD, SED) SAS 1.6 TB
UCS-SD800GBEK9 800 GB Enterprise performance SAS SSD (10X DWPD, SED) SAS 800 GB
UCS-SD400GBEK9 400 GB Enterprise performance SAS SSD (10X DWPD, SED) SAS 400 GB
UCS-SD600GBE3K9 600 GB Enterprise performance SATA SSD (3X DWPD, SED) SATA 600 GB
Enterprise Value SSDs (Low endurance, supports up to 1 FDWP (Full drive write per day))3
UCS-SD960GBE1K9 960 GB Enterprise value SATA SSD (1X DWPD, SED) SATA 960 GB
UCS-SD480GBE1K9 480 GB Enterprise Value SATA SSD (1X DWPD, SED) SATA 480 GB
UCS-SD120GBE1K9 120GB Enterprise Value SATA SSD (1X DWPD) SATA 120 GB
UCS-SD240GBM1K9 240GB Enterprise Value SSD (SATA) (1X FWPD, SED) SATA 240 GB
UCS-SD960GBM1K9 960GB Enterprise Value SSD (SATA) (1X FWPD, SED) SATA 960 GB
UCS-SD38TBM1K9 3.8TB Enterprise Value SSD (SATA) (1X FWPD, SED) SATA 3.8 TB

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 45
CONFIGURING the SERVER

Table 16 Available Hot-Pluggable Self-Encrypting Sled-Mounted HDDs and SSDs (continued)

Drive
Product ID (PID) PID Description1 Capacity
Type
NOTE: Cisco uses solid state drives from a number of vendors. All solid state drives are subject to physical write limits
and have varying maximum usage limitation specifications set by the manufacturer. Cisco will not replace any solid state
drives that have exceeded any maximum usage specifications set by Cisco or the manufacturer, as determined solely by
Cisco

Notes . . .
1. For all self-encrypting drives (SED), standalone Management (CIMC) is supported for configuring and managing
local keys (UCSM is not supported). For now, SED drives are managed with local key management only. In the
future, third-party key management will be supported. Also, 4K sector format drives do not support Vmware and
require UEFI boot.
2. Targeted for write centric IO applications. Supports endurance of 10X or 3X DWPD (drive writes per day).
Target applications are caching, online transaction processing (OLTP), data warehousing, and virtual desktop
infrastructure (VDI).
3. Targeted for read centric IO applications. Supports endurance of 1X DWPD (drive writes per day). Target
applications are boot, streaming media, and collaboration.

Approved Configurations

(1) For systems with an 8-drive backplane:

 The embedded software RAID default supports up to 8 internal SATA HDDs with RAID 0, 1, 10
support.
 The embedded software RAID 5 upgrade key option supports up to 8 internal SATA HDDs with
RAID 0, 1, 10, 5 support.

(2) For systems with a 16-drive backplane:

 The Cisco 12G SAS Modular RAID controller upgrade option supports up to 16 internal SAS
HDDs and SAS/SATA SSDs.
— The Cisco 12G SAS Modular RAID controller with FBWC option (supports JBOD, RAID
0, 1, 10, 5, 6, 50, and 60)

(3) For systems with a 24-drive backplane:

 The Cisco 12G SAS Modular RAID controller upgrade option supports up to 24 internal SAS
HDDs and SAS/SATA SSDs.
— The Cisco 12G SAS Modular RAID controller with FBWC option (supports JBOD, RAID
0, 1, 10, 5, 6, 50, and 60)

46 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

NOTE: If you selected a Cisco 12G SAS Modular RAID controller for internal
HDDs/SSDs, you have the following options:
 Cisco 12G SAS Modular RAID controller with FBWC option (supports JBOD, and
RAID up to 0, 1, 10, 5, 6, 50, and 60)
 Select up to 8, 16, or 24 SAS HDDs or SAS/SATA SSDs, as appropriate, listed in
Table 13 on page 39.
 See SELECT RAID CONTROLLERS, page 27 for more details.

Caveats

 You can choose only SATA HDDs when using embedded software RAID.
 You can choose only SAS HDDs or SAS/SATA SSDs when using the Cisco 12G SAS Modular RAID
Controller.
 You can mix HDDs and SSDs as long as you keep all HDDs in their own RAID volume and all
SSDs in their own RAID volume.
 You can mix SAS HDDs and SAS/SATA SSDs when using the Cisco 12G SAS Modular RAID
Controller.
 Non-SED drives (see SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs),
page 39) can be mixed with the SED drives in Table 16 on page 45.
 SED drives are compatible with only with the combination of a UCSC-MRAID12G RAID
controller along with one of the flash-back write cache modules:
— UCSC-MRAID12G-1GB, or
— UCSC-MRAID12G-2GB, or
— UCSC-MRAID12G-4GB

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 47
CONFIGURING the SERVER

STEP 9 SELECT PCIe OPTION CARD(s)


The standard PCie card offerings are:

 Modular LAN on Motherboard (MLOM)


 Virtual Interface Cards (VICs)
 Network Interface Cards (NICs)
 Converged Network Adapters (CNAs)
 Host Bus Adapters (HBAs)
 UCS Storage Accelerators

Select PCIe Option Cards

The available PCIe option cards are listed in Table 17.

Table 17 Available PCIe Option Cards1

Card
Product ID (PID) PID Description
Height
Modular LAN on Motherboard (mLOM)2
UCSC-MLOM-C10T-02 Cisco UCS VIC1227T VIC MLOM - Dual Port 10GBaseT N/A
UCSC-MLOM-CSC-02 Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+ N/A
UCSC-MLOM-IRJ45 Intel i350 quad-port MLOM NIC N/A
UCSC-MLOM-C40Q-03 Cisco VIC 1387 Dual Port 40Gb QSFP CNA MLOM N/A
Virtual Interface Cards (VICs)
UCSC-PCIE-CSC-02 Cisco VIC 1225 Dual Port 10Gb SFP+ CNA Half
UCSC-PCIE-C10T-02 Cisco VIC 1225T Dual Port 10GBaseT CNA Half
UCSC-PCIE-C40Q-03 Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA w/RDMA Half
Network Interface Cards (NICs)
1 Gb NICs
UCSC-PCIE-IRJ45 Intel i350 Quad Port 1Gb Adapter Half
10 Gb NICs
N2XX-AIPCI013 Intel X520 Dual Port 10Gb SFP+ Adapter Half
UCSC-PCIE-ITG Intel X540 Dual Port 10GBase-T Adapter Half
UCSC-PCIE-QNICBT QLogic QLE8442 dual-port 10Gbase-T NIC Half
UCSC-PCIE-QNICSFP QLogic QLE8442 dual-port 10G SFP+ NIC Half
UCSC-PCIE-ID10GC Intel X550-T2 dual-port 10GBase-T NIC Half
UCSC-PCIE-ID10GF Intel X710-DA2 dual-port 10G SFP+ NIC Half
UCSC-PCIE-IQ10GF Intel X710 quad-port 10G SFP+ NIC Full
25 GB NICs
UCSC-PCIE-QD25GF Qlogic QL41212H dual-port 25G NIC Half

48 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 17 Available PCIe Option Cards1 (continued)

Card
Product ID (PID) PID Description
Height
40 GB NICs
UCSC-PCIE-ID40GF Intel XL710 dual-port 40G QSFP+ NIC Half
10 Gb Converged Network Adapters (CNAs)
UCSC-PCIE-E14102B Emulex OCe14102B-UX dual-port 10G SFP+ with iSCSI, FCoE CNA Half
UCSC-PCIE-E14102 Emulex OCe14102-UX dual-port 10 GbE FCoE CNA Half
UCSC-PCIE-Q8362 Qlogic QLE8362 dual-port 10 GbE FCoE CNA Half
Host Bus Adapters (HBAs)
UCSC-PCIE-BS32GF Broadcom LPe32000 Single-Port 32G FC HBA Half
UCSC-PCIE-BD32GF Broadcom LPe32002 Dual-Port 32G FC HBA Half
UCSC-PCIE-QD32GF Qlogic QLE2742 dual-port 32G FC HBA Half
N2XX-AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half
UCSC-PCIE-Q2672 Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics Half
N2XX-AEPCI05 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Half
UCSC-PCIE-E16002 Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics Half
UCS Storage Accelerators4
UCSC-F-S64002 UCS Rack PCIe Storage 6400 GB SanDisk SX350 Medium Endurance Full
UCSC-F-S32002 UCS Rack PCIe Storage 3200 GB SanDisk SX350 Medium Endurance Half
UCSC-F-S16002 UCS Rack PCIe Storage 1600 GB SanDisk SX350 Medium Endurance Half
UCSC-F-S13002 UCS Rack PCIe Storage 1300 GB SanDisk SX350 Medium Endurance Half
UCS NVMe/PCie Add in Cards
UCSC-F-H38001 3.8 TB NVMe/PCIe storage (HGST SN150) Read Intensive Half
UCSC-NVME-H64003 Cisco HHHL AIC 6.4T HGST SN260 NVMe Extreme Perf High Endrnc HHHL*
UCSC-NVME-H76801 Cisco HHHL 7.7T HGST SN260 NVMe Extreme Perf Value Enderance HHHL*
UCSC-NVME-H32003 Cisco HHHL AIC 3.2T HGST SN260 NVMe Extreme Perf High Endrnc HHHL*
*HHHL= Half Height Half Length
Notes . . .
1. The GPU cards (see ORDER GPU CARDS AND GPU POWER CABLES (OPTIONAL), page 58) must be inserted into
a full length x16 (electrical) PCIe slot. See Riser Card Configuration and Options, page 93 for more details.
The rest of the PCIe cards are x8 (electrical) and can be plugged into any PCIe slot of riser 1 or riser 2.
2. The mLOM cards do not plug into any of the riser 1 or riser 2 card slots; instead, they plug into a connector
inside the server chassis.
3. The Intel X520 supports the following Cisco PIDs: UCS-SFP-1WLR and UCS-SFP-1WSR SFPs. Refer to the Intel
X520 product brief for a full list of supported optics and cables.
4. A maximum of six storage accelerator cards are supported and some are riser dependent. 1.3 TB, 2.6 TB, or 3.2
TB cards should not be installed in slots 5 or 6 so the total number of those capacity points is four.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 49
CONFIGURING the SERVER

Caveats

 If you choose an external drives controller (Cisco 9300-8e 12G SAS HBA), it will consume one
PCIe slot.
 A maximum of six storage accelerator cards are supported and some are riser dependent.
1.3 TB, 2.6 TB, or 3.2 TB cards should not be installed in to slots 5 or 6 so the total number
of those capacity points is four.
 For 1-CPU systems:
— Only the PCIe slots on PCIe riser 1 are available for 1-CPU system.
— The PCIe slots on riser 2 are not supported on 1-CPU systems. The slots are
full-height PCIe slots 4, 5, and 6 (see Figure 5 on page 9). These are the slots on
the right when looking at the rear of the server.
— Only a single plug-in PCIe VIC card may be installed on a 1-CPU system, and it must
be installed in slot 2 of riser 1. You can order an mLOM VIC card to be installed in
the mLOM slot internal to the chassis and thus have two VIC cards in operation at
the same time. See Table 17 on page 48 for the selection of plug-in and mLOM VIC
cards. See also Table 1 on page 11 and Riser Card Configuration and Options,
page 93 for the PCIe slot physical descriptions.
 For 2-CPU systems:
— Depending on the riser 1 option chosen, up to six PCIe slots are available, three on
PCIe riser 1 (PCIe slots 1, 2, and 3) and three on PCIe riser 2 (PCIe slots 4, 5, and 6).
— All of the slots are full-height.
— Two plug-in PCIe VIC cards can be installed in 2-CPU systems, using slots 2 and 5. In
addition, you can order an mLOM VIC card, which is installed in the mLOM slot inside
the chassis and thus have three VIC cards in operation at the same time. See
Table 17 on page 48 for the selection of plug-in and mLOM VIC cards. See also
Table 1 on page 11 and Riser Card Configuration and Options, page 93 for the
PCIe slot physical descriptions.
— If GPUs are installed in slots 2 (Riser 1 option A) and 5 (Riser 2), the NCSI capability
automatically switches over to slots 1 (Riser 1 option A) and 4 (Riser 2). Therefore,
Cisco PCIe VICs can be installed in slots 1 and 4 if GPUs are installed in slots 2 and 5.

NOTE: UCSM managed servers are discoverable only if a VIC 1225 is installed in slot
2 or a VIC 1227/1227T is installed in the MLOM slot. If you install two GPUs, they
must be located in slots 2 and 5. Therefore, if two GPUs are installed, UCSM
managed servers are discoverable only if you install a VIC 1227/1227T in the MLOM
slot.

 Other considerations for the Cisco VIC 1225/1225T/1227/1227T/1385 cards:


— VIC 1225 and VIC 1227/1227T support 10G SFP+ optical and copper twinax
connections
— VIC 1225T supports RJ45 Category 6 or better twisted pair cable connections
— The 2-CPU version of the server supports installation of two PCIe Cisco VIC
1225/1225T/1385 cards and they are supported in PCIe slots 2 and 5. Slot 2 is the

50 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

primary slot for UCSM integration and slots 2 and 5 are the primary slots for Cisco
NIC card mode.
— VIC 1385 supports a 4x10 Gbps QSFP to SFP breakout fiber cable.
— The server supports up to two PCIe Cisco VICs (1225, 1225T, 1385) plus an MLOM VIC
(1227, 1227T), however, single wire management is supported on only one VIC at a
time. If multiple VICs are installed on a server, only one slot has NCSI enabled at a
time and for single wire management, priority goes to the MLOM slot, then slot 2,
then slot 5 for NCSI management traffic. When multiple cards are installed, connect
the single wire management cables in the priority order mentioned above.
— Installation of the Cisco UCS VIC1225 requires that the server have CIMC firmware
version 1.4(6) or later installed and VIC firmware of 2.1(0) or later. Installation of
the Cisco UCS VIC1225T, requires that the server have CIMC firmware version 1.5(1)
or later installed and VIC firmware of 2.1(1) or later.
— The server supports installation of up to two plug-in Cisco VIC 1225/1225T/1385
cards and they are supported only in certain slots. A third simultaneously operating
VIC can be the mLOM VIC 1227/1227T card, which is installed in a slot inside the
chassis. See Table 18 for details.
— The VIC features mentioned in this section are supported with the following
software releases: 2.0.6 (CIMC) and 2.2.5a (UCSM).

Table 18 Cisco UCS 240 M4 Requirements for Plug-in Virtual Interface Cards

Number of
Primary Slot For
Plug-in Minimum Minimum
Slots That UCS Integration
VIC PID VICs Cisco IMC VIC
Support VICs1 or Cisco Card
Supported Firmware Firmware
NIC Mode
in Server

Cisco UCS VIC1225 2 PCIe 2 Riser 1: PCIe 2 1.4(6) 2.1(0)


(UCSC-PCIE-CSC-02) PCIe 1 Riser 2: PCIe 5
Cisco UCS VIC1225T 2 PCIe 5 See footnote 1.5(1) 2.1(1)
(UCSC-PCIE-C10T-02) PCIe 4

Cisco UCS VIC 13853 2 See footnote2 2.0(2) 2.2(16)


(UCSC-PCIE-C40Q-03)

Notes . . .
1. For riser PID UCSC-PCI-1B-240M4 (riser 1 option B) only: Slot 2 is the only slot that supports a VIC.
2. For riser PID UCSC-PCI-1A-240M4 (riser 1 option A) only: When a GPU card is present in slot 2 of riser 1 option
A, NCSI support automatically shifts to slot 1, which becomes the primary slot for a VIC. When a GPU card is
present in riser 2 slot 5, NCSI support automatically shifts to slot 4, which becomes the primary slot for a VIC.
UCSM managed servers are discoverable only if a VIC 1225 is installed in slot 2 or a VIC 1227/1227T is installed
in the MLOM slot. If you install two GPUs, they must be located in slots 2 and 5. Therefore, if two GPUs are
installed, UCSM managed servers are discoverable only if you install a VIC 1227/1227T in the MLOM slot.
3. If the Cisco UCS VIC 1385 is installed with another VIC, the VIC 1385 should be installed in the primary VIC slot
(an x16 slot, such as riser 1 option A slot 2 or riser 2 slot 5). If riser1 option B is installed, slot 2 is an x8 slot, in
which case the VIC 1385 should be installed in slot 5.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 51
CONFIGURING the SERVER

 The quantity and type of PCIe cards that can be installed depends in the riser card options.
See Riser Card Configuration and Options, page 93 for additional details.
 To help ensure that your operating system is compatible with the card you have selected, or
to see additional cards that have been qualified to work with the UCS C240 M4 server, but
are not sold on the Cisco pricelist, check the Hardware Compatibility List at this URL:

http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html

52 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 10 ORDER OPTIONAL NETWORK CARD ACCESSORIES


Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that
are available with the server.

Choose Optional Twinax Cables

Table 19 lists the copper twinax cables available for the PCIe cards. You can choose cable
lengths of 1, 3, 5, 7, or 10 meters. The two longer cables (7 and 10 meters) are active, which
means that they contain active components within the SFP+ housing to improve signal quality.

Table 19 Available Twinax Cables

Product ID (PID) PID Description

SFP-H10GB-CU1M 10GBASE-CU SFP+ Cable (1 M)

SFP-H10GB-CU3M 10GBASE-CU SFP+ Cable (3 M)

SFP-H10GB-CU5M 10GBASE-CU SFP+ Cable (5 M)

Approved Configurations

(1) Choose Up to Two Twinax Cables for Each Network Card Ordered

 You may choose one or two twinax cables for each compatible PCIe network card ordered.
The cables can be different lengths; however, you would normally order two cables of equal
lengths to connect to the primary and redundant network switching equipment.

Choose Optional SFP Modules

Optical Cisco SFP+ modules are listed in Table 20.

Table 20 Available SFP Modules

Product ID (PID) PID Description

SFP-10G-SR 10GBASE-SR SFP+ Module 


850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring

SFP-10G-LR 10GBASE-LR SFP+ Module


1310 nm, single mode, LR, 3.3 V, with Digital Optical Monitoring

DS-SFP-FC8G-SW 8 Gbit SFP+ Module


850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 53
CONFIGURING the SERVER

NOTE: The Intel X520 NIC supports the following Cisco PIDs: UCS-SFP-1WLR and
UCS-SFP-1WSR SFPs. Refer to the Intel X520 product brief for a full list of supported
optics and cables.

Approved Configurations

(1) Choose Up to Two SFP+ Modules for Each Network Card Ordered

 You may choose one or two SFP+ optical modules cables for each compatible PCIe network
card ordered. You would normally order two modules for connecting to the primary and
redundant network switching equipment. With the SFP+ optical modules, you can use
common fiber optic cables, widely available.

See the Figure 8 on page 57 for typical SFP+ and twinax connections to the network cards.

Caveats

Check the table on the following page for compatibility between the PCIe network cards and
SFPs or twinax cables.

NOTE: The table shows all PCIe network cards for all C-series servers. Not all of
the cards shown in the table are supported in this server. The intent of the table
is to show compatibility between cards and twinax cables or SFPs.

54 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 21 PCIe Card Compatibility

Twinax Cisco SFP Modules


PCIe Cards
Cables SFP-10G-SR SFP-10G-LR DS-SFP-FC8G-SW
Converged Network Adapters (CNAs)
UCSC-PCIE-BSFP
(Broadcom 57712 Dual Port 10Gb SFP+ w/TOE Yes Yes No
iSCSI)
UCSC-PCIE-CSC-02 
Yes Yes Yes No
(Cisco VIC 1225 Dual Port 10Gb SFP+ CNA)
UCSC-PCIE-C10T-02
No No No No
(Cisco VIC 1225T Dual Port 10GBaseT CNA)
UCSC-MLOM-CSC-02 
(Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb Yes Yes Yes No
SFP+)
UCSC-MLOM-C10T-02
(Cisco UCS VIC1227T VIC MLOM - Dual Port No No No No
10GBaseT)
UCSC-PCIE-C40Q-02
Yes No1 No
(Cisco VIC 1285 Dual Port 40Gb QSFP CNA)
UCSC-PCIE-C40Q-03
(Cisco VIC 1385 Dual Port 40Gb QSFP+ CNA Yes No1 No
w/RDMA)
UCSC-PCIE-ESFP 
(Emulex OCe11102-FX dual-port 10 GbE FCoE CNA Yes Yes No
(Gen 3 CNA))
UCSC-PCIE-QSFP 
Yes Use Qlogic SFP
(QLogic QLE8242-CU dual-port 10 GbE FCoE CNA)
UCSC-PCIE-B3SFP
Yes Yes No
(Broadcom 57810 10Gb A-FEX SFP+
UCSC-PCIE-Q8362 
Yes Use Qlogic SFP
(Qlogic QLE8362 dual-port 10 GbE FCoE CNA)
UCSC-PCIE-E14102
(Emulex OCe14102-UX dual-port 10 GbE FCoE Yes Yes No
CNA)
Network Interface Cards (NICs)
N2XX-ABPCI01-M3 
(Broadcom 5709 Dual-Port Ethernet PCIe Adapter Use RJ45 Ethernet cable
for M3 Servers)
N2XX-ABPCI03-M3 
(Broadcom 5709 Quad Port 10/100/1Gb NIC Use RJ45 Ethernet cable
w/TOE iSCSI for M3 Servers
N2XX-AIPCI01  Use Intel SFP
Yes
(Intel X520 Dual Port 10Gb SFP+ Adapter) UCS-SFP-1WLR or UCS-SFP-1WSR
UCSC-PCIE-ITG 
Use RJ45 Ethernet cable
(Intel X540 Dual Port 10GBase-T Adapter)
UCSC-PCIE-IRJ45
Use RJ45 Ethernet cable
(Intel i350 Quad Port 1Gb Adapter

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 55
CONFIGURING the SERVER

Table 21 PCIe Card Compatibility (continued)

Twinax Cisco SFP Modules


PCIe Cards
Cables SFP-10G-SR SFP-10G-LR DS-SFP-FC8G-SW
UCSC-PCIE-BTG
(Broadcom 57712 Dual Port 10GBASE-T w/TOE Yes No No
iSCSI)
Host Bus Adapters (HBAs)
N2XX-AEPCI03 
(Emulex LPe 11002 Dual Port 4Gb Fibre Channel No Preinstalled - do not change SFP
HBA
N2XX-AEPCI05 
(Emulex LPe 12002 Dual Port 8Gb Fibre Channel No Preinstalled - do not change SFP
HBA)
N2XX-AQPCI03 
(QLogic QLE2462 Dual Port 4Gb Fibre Channel No Preinstalled - do not change SFP
HBA)
N2XX-AQPCI05
(QLogic QLE2562 Dual Port 8Gb Fibre Channel No Preinstalled - do not change SFP
HBA)
UCSC-PCIE-Q2672
(Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA No Preinstalled - do not change SFP
with SR Optics)
UCSC-PCIE-E16002
(Emulex LPe16002-M6, 16Gb Fibre Channel HBA No Preinstalled - do not change SFP
with SR Optics)
Notes . . .
1. This card supports a 4x10 Gbps QSFP to SFP breakout fiber cable.

56 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Figure 8 Network Card Connections

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 57
CONFIGURING the SERVER

STEP 11 ORDER GPU CARDS AND GPU POWER CABLES (OPTIONAL)


Select GPU Options

The available GPU PCIe options are listed in Table 22.

Table 22 Available PCIe Option Cards

Maximum cards per


Product ID (PID) PID Description Card Size
node

GPU PCIe Cards


UCSC-GPU-P100-16G NVIDIA P100 16GB Full-height, double wide -
UCSC-GPU-P100-12G NVIDIA P100 12GB Full-height, double wide -
UCSC-GPU-7150X2 AMD Firepro 7150x2 Full-height, double wide -
UCSC-GPU-M601 NVIDIA Tesla M60 Full-height, double wide -

UCSC-GPU-K801 NVIDIA K80 Full-height, double wide -

UCSC-GPU-M102 NVIDIA M10 Full-height, double wide 2

Notes . . .
1. You must order a kit with this GPU (UCS-300WKIT-240M4). It is a 300-Watt cable, HS and kit system for the UCS
C240M4 rack server. Only one kit is needed for either one or two GPUs.
2. A power cable is not included with the M10. When ordering an M10, you must to purchase a power cable
(UCSC-GPUCBL-240M4=) for the GPU.

CAUTION: Do not operate the C240 M4 server with the 300W GPU kit installed,
but no GPU card installed. The kit has been designed to provide adequate airflow
for cooling only when at least one GPU card is installed.

CAUTION: When using GPU cards, the operating temperature range is 32° to
95°F (0° to 35°C).

NOTE: All GPU cards require two CPUs and a minimum of two power supplies in the
server. 1400 W power supplies are recommended. Use the power calculator at the
following link to determine the needed power based on the options chosen (CPUs,
drives, memory, and so on):

http://ucspowercalc.cisco.com

58 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Select GPU Power Cables

Whenever you select a K1/K2/K40 or AMD GPU for this server, you must also select one power
cable for each GPU selected. The available GPU power cables are listed in Table 23.

Table 23 Available GPU Power Cables

Product ID (PID) PID Description

UCSC-GPUCBL-240M4 C240 M4 GPU Power Cable


UCS-300WK-240AMD 300 Watt AMD Cable and Kit for UCS C240 M4 Rack Server

Whenever you select a K80 GPU for this server, you must also select one power cable kit (for
either one or two K80 GPUs). The available GPU power cables are listed in Table 24.

Table 24 Available GPU Power Cables (K80 and M60 only)

Product ID (PID) PID Description

UCS-300WKIT-240M4 300 Watt Cable, HS and Kit for UCS C240M4 Rack Server

Caveats

 NVIDIA GPUs can support only less than 1 TB of total memory in the server. Do not install
more than fourteen 64-GB DIMMs when using an NVIDIA GPU card in this server. Please note,
this limitation does not apply to Pascal series GPU (P100)
 NVIDIA GRID K1 and K2 GPUs can be mixed. No other GPU mixing is allowed.
 If you order a K80 GPU, note the following:
— You cannot mix the K80 with any other GPU
— You must select 2 CPUs for the server
 Slot 5 on riser card 2 is the required slot for the first GPU.
 Slot 2 on riser card 1 is the secondary slot for a second GPU. The riser card 1 options that
are compatible with GPUs are:
— Riser card 1 option A (UCSC-PCI-1A-240M4)

NOTE: UCSM managed servers are discoverable only if a VIC 1225 is installed in slot
2 or a VIC 1227/1227T is installed in the MLOM slot. If you install two GPUs, they
must be located in slots 2 and 5. Therefore, if two GPUs are installed, UCSM
managed servers are discoverable only if you install a VIC 1227/1227T in the MLOM
slot.

NOTE: For more information on the riser 1 card options, see Riser Card
Configuration and Options, page 93.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 59
CONFIGURING the SERVER

 If you order one or two boot drives, you can order a maximum of one GPU and it must be
installed in Riser 2 (UCSC-PCI-2-C240M4) slot 5.
 AMD 7150x2 can support only less than 1TB of total memory in the server.

60 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 12 ORDER POWER SUPPLY


The C240 M4 server requires at least one power supply. A lightly loaded server may require one
or two 650 W power supplies. A fully loaded server might need to be powered with two larger
capacity power supplies. A server with one GPU requires at least two power supplies (1400 W
power supplies are recommended). A server with two GPUs also requires at least two power
supplies (1400 W power supplies are recommended). Use the power calculator at the following
link to determine the needed power based on the options chosen (CPUs, drives, memory, and so
on):

http://ucspowercalc.cisco.com

Table 25 Power Supply

Product ID (PID) PID Description

UCSC-PSU2V2-1400W 1400W V2 AC Power Supply (200 - 240V) 2U & 4U C Series

UCSC-PSU2V2-1200W1 1200W / 800W V2 AC Power Supply for 2U C-Series Servers

UCSC-PSU-930WDC 930 W -48V DC Common Slot Power Supply for C-series servers

UCSC-PSU2V2-930DC 930 W - 48V V2 DC Power Supply for 2U C-Series Servers

UCSC-PSU2V2-650W 650W V2 AC Power Supply for C-Series Servers

Notes . . .
1. The power output is 1200W with a 200-240V input and 800W with a 100-120V input.

NOTE: In a two power supply server, both power supplies must be identical.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 61
CONFIGURING the SERVER

STEP 13 SELECT AC POWER CORD(s)


Using Table 26, select the appropriate AC power cords. You can select a minimum of no power
cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is
shipped with the server.

Table 26 Available Power Cords

Product ID (PID) PID Description Images

R2XX-DMYMPWRCORD No power cord (dummy PID to Not applicable


allow for a no power cord option)

CAB-N5K6A-NA Power Cord, 200/240V 6A, North


America
Cordset rating: 10 A, 250 V
Plug: NEMA 6-15P Length: 8.2 ft

Connector:
IEC60320/C13

186570
CAB-AC-L620-C13 AC Power Cord, NEMA L6-20 - C13,
2M/6.5ft

CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L,


C13/C14, 10A/250V

CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD, PWR,


2 Meter, C13/C14,10A/250V

CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6
0320/C13, 3.0M

62 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 26 Available Power Cords

Product ID (PID) PID Description Images

CAB-250V-10A-AR Power Cord, 250V, 10A, Argentina


2500 mm

Cordset rating: 10 A, 250/500 V MAX


Length: 8.2 ft
Plug:
EL 219
(IRAM 2073) Connector:
EL 701
(IEC60320/C13)

186571
CAB-9K10A-AU Power Cord, 250VAC 10A 3112 Plug,
Australia
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm

Connector:
Plug: EL 701C
EL 210 (EN 60320/C15)

186580
(BS 1363A) 13 AMP fuse

CAB-250V-10A-CN Power Cord, SFS, 250V, 10A, China

Cordset rating 10A, 250V


Plug:
(2500 mm)
EL 218
(CCEE GB2009)

Connector:
EL 701

186573
(IEC60320/C13)

CAB-250V-10A-CN AC Power Cord - 250V, 10A - PRC

CAB-9K10A-EU Power Cord, 250VAC 10A CEE 7/7


Plug, EU
Cordset rating: 10A/16 A, 250 V
Plug: Length: 8 ft 2 in. (2.5 m)
M2511
Connector:
VSCC15

186576
CAB-250V-10A-ID Power Cord, SFS, 250V, 10A, India
OVE

Cordset rating 16A, 250V


Plug:
(2500mm)
EL 208

Connector:
EL 701
187490

CAB-250V-10A-IS Power Cord, SFS, 250V, 10A, Israel


EL-212
16A
250V

Cordset rating 10A, 250V/500V MAX


(2500 mm)

Connector:
Plug: EL 701B
EL 212 (IEC60320/C13)
186574

(SI-32)

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 63
CONFIGURING the SERVER

Table 26 Available Power Cords

Product ID (PID) PID Description Images

CAB-9K10A-IT Power Cord, 250VAC 10A CEI


23-16/VII Plug, Italy
Cordset rating: 10 A, 250 V
Plug: Length: 8 ft 2 in. (2.5 m) Connector
I/3G C15M
(CEI 23-16) (EN60320/C15 )

186575
CAB-9K10A-SW Power Cord, 250VAC 10A MP232
Plug, Switzerland
Cordset rating: 10 A, 250 V
Plug: Length: 8 ft. 2 in (2.5 m)
MP232-R
Connector:
IEC 60320 C15

186578
CAB-9K10A-UK Power Cord, 250VAC 10A BS1363
Plug (13 A fuse), UK
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm

Connector:
Plug: EL 701C
EL 210 (EN 60320/C15)

186580
(BS 1363A) 13 AMP fuse

CAB-9K12A-NA Power Cord, 125VAC 13A NEMA


5-15 Plug, North America

CAB-250V-10A-BR Power Cord - 250V, 10A - Brazil


1 76.2 From Plug End

2,133.6 ± 25

CAB-JPN-3PIN Power Cord 3PIN, Japan Image not available

CAB-C19-C20-3M-JP Power Cord C19-C20, 3M/10ft Image not available


Japan PSE mark

64 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 14 ORDER TOOL-LESS RAIL KIT AND OPTIONAL REVERSIBLE CABLE


MANAGEMENT ARM
Select a Tool-Less Rail Kit

Select a tool-less rail kit from Table 27.

Table 27 Tool-Less Rail Kit Options

Product ID (PID) PID Description

UCSC-RAILB-M4 Ball Bearing Rail Kit for C220 M4 and C240 M4 Rack Servers

Select an Optional Reversible Cable Management Arm

The reversible cable management arm mounts on either the right or left slide rails at the rear of
the server and is used for cable management. Use Table 28 to order a cable management arm.

Table 28 Cable Management Arm

Product ID (PID) PID Description

UCSC-CMA-M4 Reversible CMA for tool-less C240 M4 ball bearing rail kit

For more information about the tool-less rail kit and cable management arm, see the Cisco UCS
C240 M4 Installation and Service Guide at this URL:

http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C240M4/install/C240M4.html

NOTE: If you plan to rackmount your UCS C240 M4 server, you must order a tool-less
tool-less rail kit.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 65
CONFIGURING the SERVER

STEP 15 SELECT NIC MODE (OPTIONAL)


By default, the C240 M4 server NIC mode is configured to be Shared LOM Extended. This NIC
mode allows any LOM port or adapter card port to be used to access the Cisco Integrated
Management Controller (CIMC). The Cisco VIC card must be installed in a slot with NCSI support.

To change the default NIC mode to Dedicated, select the UCSC-DLOM-01 PID shown in Table 29.
In Dedicated NIC mode, the CIMC can be accessed only through the dedicated management port.
See Chassis Rear View, page 9 for the location of the management port.

To change the default NIC mode to Cisco Card Mode, select the UCSC-CCARD-01 PID shown in
Table 29. In this mode, you can assign an IP address to the CIMC using DHCP and from there you
can fully automate your deployment.

For more details on all the NIC mode settings, see

http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/sw/gui/config/guide/2-0/b_
Cisco_UCS_C-series_GUI_Configuration_Guide_201.pdf

Table 29 Dedicated NIC Mode Ordering Information

Product ID (PID) PID Description

UCSC-DLOM-01 Dedicated Mode BIOS setting for C-Series Servers

UCSC-CCARD-01 Cisco Card Mode BIOS setting for C-Series Servers

66 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 16 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL)


Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store
artifacts used to authenticate the platform (server). These artifacts can include passwords,
certificates, or encryption keys. A TPM can also be used to store platform measurements that
help ensure that the platform remains trustworthy. Authentication (ensuring that the platform
can prove that it is what it claims to be) and attestation (a process helping to prove that a
platform is trustworthy and has not been breached) are necessary steps to ensure safer
computing in all environments.

The TPM ordering information is listed in Table 30.

Table 30 Trusted Platform Module

Product ID (PID) PID Description

UCSX-TPM2-001 Trusted Platform Module 1.2 SPI-based for UCS Servers

UCSX-TPM2-002 Trusted Platform Module 2.0 for UCS servers

NOTE: The TPM module used in this system conforms to TPM v1.2 and 2.0, as
defined by the Trusted Computing Group (TCG). It is also SPI-based.

NOTE: TPM installation is supported after-factory. However, a TPM installs with a


one-way screw and cannot be replaced, upgraded, or moved to another server. If a
server with a TPM is returned, the replacement server must be ordered with a new
TPM. If there is no existing TPM in the server, you can install TPM 2.0. You must first
upgrade to UCS firmware that supports Intel E5-2600 v4 CPUs, which is Cisco UCS
Manager Release 2.2(7) and later or Release 3.1(1) and later (because Cisco aligned
support for TPM 2.0 with these CPUs).

CAUTION: If the Cisco UCS server (with Intel E5-2600 v4 or v3 CPUs) is running UCS
firmware that added support for Intel E5-2600 v4 CPUs, then it will work with TPM
version 2.0. However, if you downgrade the firmware and BIOS to a version earlier
than Release 2.2(7) or earlier than Release 3.1(1), then you are vulnerable to a
potential security exposure. See the following support matrix for TPM versions.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 67
CONFIGURING the SERVER

Table 31 TPM Support Matrix by Intel CPU Version

Intel CPU TPM Version Minimum UCS Manager (UCSM) Version

Intel E5-2600 v3 TPM 1.2 Release 2.2(3)

TPM 2.0 Release 2.2(7) or Release 3.1(1)

Intel E5-2600 v4 TPM 1.2 Release 2.2(7) or Release 3.1(1)

TPM 2.0 Release 2.2(7) or Release 3.1(1)

68 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 17 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL)


Order 128 GB,64 GB, or 32 GB SD cards. See Figure 9 on page 82 for the location of the SD
cards. There are two locations, SD1 and SD2.

Table 32 Secure Digital (SD) Card

Product ID (PID) PID Description

UCS-SD-128G 128 GB SD Card for UCS Servers

UCS-SD-64G-S 64 GB SD Card for UCS Servers

UCS-SD-32G-S 32 GB SD Card for UCS Servers

Caveats

 Install either one or two 64, or 32 GB SD cards


 Do not mix SD card sizes

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 69
CONFIGURING the SERVER

STEP 18 ORDER OPTIONAL USB 3.0 DRIVE


You can order one optional USB 3.0 drive. The USB drive ordering information is listed in
Table 33.

Table 33 USB 3.0 Drive

Product ID (PID) PID Description

UCS-USBFLSHB-16GB UCS Servers 16 GB Flash USB Drive

See Figure 9 on page 82 for the location of the USB connector

70 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 19 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE


Several software programs are available. Select as desired from Table 34.

Table 34 Software (for 2-CPU servers)

PID Description Product ID (PID)


Cisco One
C1F2PUCSK9 Cisco ONE Foundation Perpetual UCS
C1A1PUCSK9 Cisco ONE Enterprise Cloud Perpetual UCS
C1UCS-OPT-OUT Cisco One Data Center Compute Opt Out Option
Energy Management (JouleX)
CEM-DC-PER Perpetual License Key for Cisco Energy Management for DC
UCS Director
CUIC-PHY-SERV-BM-U Cisco UCS Director Resource Lic - 1 Phy Sevr node bare metal
CUIC-PHY-SERV-U Cisco UCS Director Resource Lic - One physical Server node
CUIC-TERM Acceptance of Cisco UCS Director License Terms
UCS Performance Manager
UCS-PM-IE UCS Performance Manager
UCS-PM-EE UCS Performance Manager Express
EVAL-UCS-PM-IE UCS Performance Manager - 90 days evaluation
EVAL-UCS-PM-EE UCS Performance Manager Express - 90 days evaluation
Nexus 1000V for Hyper-V and vSphere
N1K-VSG-UCS-BUN Nexus 1000V Adv Edition for vSphere Paper License Qty 1
IMC Supervisor
CIMC-SUP-B10 IMC Supervisor- Branch Mgt SW for C & E-Series up to 1K Svrs
CIMC-SUP-B02 IMC Supervisor- Branch Mgt SW for C & E-Series up to 250 Svrs
UCS Multi-Domain Manager
UCS-MDMGR-100S UCS Multi-Domain Manager (Central) Per Server License (100+)
UCS-MDMGR-50S UCS Multi-Domain Manager (Central) Per Server License (50+)
UCS-MDMGR-1S UCS Multi-Domain Manager (Central) Per Server License
UCS-MDMGR-10S UCS Multi-Domain Manager (Central) Per Server License (10+)
UCS-MDMGR-1DMN UCS Multi-Domain Manager (Central) Per Domain License
VMware vCenter
VMW-VCS-STD-1A VMware vCenter 6 Server Standard, 1 yr support required
VMW-VCS-STD-3A VMware vCenter 6 Server Standard, 3 yr support required
VMW-VCS-STD-5A VMware vCenter 6 Server Standard, 5 yr support required
VMW-VCS-FND-1A VMware vCenter 6 Server Foundation (3 Host), 1 yr supp reqd
VMW-VCS-FND-3A VMware vCenter 6 Server Foundation (3 Host), 3 yr supp reqd
VMW-VCS-FND-5A VMware vCenter 6 Server Foundation (3 Host), 5 yr supp reqd
Microsoft Windows Server
MSWS-12R2-DC2S Windows Server 2012 R2 Datacenter (2 CPU/Unlimited VMs)

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 71
CONFIGURING the SERVER

Table 34 Software (for 2-CPU servers) (continued)

PID Description Product ID (PID)


MSWS-12-ST2S Windows Server 2012 Standard (2 CPU/2 VMs)
MSWS-12-DC2S Windows Server 2012 Datacenter (2 CPU/Unlimited VMs)
MSWS-12-ST2S-NS Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco SVC
MSWS-12R2-DC2S-NS Windows Server 2012 R2 Datacen (2 CPU/Unlim VM) No Cisco Svc
MSWS-12R2-ST2S Windows Server 2012 R2 Standard (2 CPU/2 VMs)
MSWS-12-DC2S-NS Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco Svc
MSWS-12R2-ST2S-NS Windows Server 2012 R2 Standard (2 CPU/2 VMs) No Cisco SVC
MSWS-19-DC16C Windows Server 2019 Data Center (16 Cores/Unlimited VMs)
MSWS-19-DC16C-NS Windows Server 2019 DC (16 Cores/Unlim VMs) - No Cisco SVC
MSWS-19-DC16C-RM Windows Server 2019 DC (16Cores/Unlim VM) Rec Media DVD Only
MSWS-19-DCA2C Windows Server 2019 Data Center - Additional 2 Cores
MSWS-19-DCA2C-NS Windows Server 2019 DC - Additional 2 Cores - No Cisco SVC
MSWS-19-ST16C Windows Server 2019 Standard (16 Cores/2 VMs)
MSWS-19-ST16C-NS Windows Server 2019 Standard (16 Cores/2 VMs) - No Cisco SVC
MSWS-19-ST16C-RM Windows Server 2019 Stan (16 Cores/2 VMs) Rec Media DVD Only
MSWS-19-STA2C Windows Server 2019 Standard - Additional 2 Cores
MSWS-19-STA2C-NS Windows Server 2019 Stan - Additional 2 Cores - No Cisco SVC
MSWS-19-DC16C Windows Server 2019 Data Center (16 Cores/Unlimited VMs)
MSWS-19-DC16C-NS Windows Server 2019 DC (16 Cores/Unlim VMs) - No Cisco SVC
MSWS-19-DC16C-RM Windows Server 2019 DC (16Cores/Unlim VM) Rec Media DVD Only
MSWS-19-DCA2C Windows Server 2019 Data Center - Additional 2 Cores
MSWS-19-DCA2C-NS Windows Server 2019 DC - Additional 2 Cores - No Cisco SVC
MSWS-19-ST16C Windows Server 2019 Standard (16 Cores/2 VMs)
MSWS-19-ST16C-NS Windows Server 2019 Standard (16 Cores/2 VMs) - No Cisco SVC
MSWS-19-ST16C-RM Windows Server 2019 Stan (16 Cores/2 VMs) Rec Media DVD Only
MSWS-19-STA2C Windows Server 2019 Standard - Additional 2 Cores
MSWS-19-STA2C-NS Windows Server 2019 Stan - Additional 2 Cores - No Cisco SVC
Red Hat
RHEL-2S2V-3A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 3-Yr Support Req
RHEL-2S2V-1A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 1-Yr Support Req
VMware
VMW-VSP-EPL-5A VMware vSphere 6 Ent Plus (1 CPU), 5-yr, Support Required
VMW-VSP-STD-1A VMware vSphere 6 Standard (1 CPU), 1-yr, Support Required
VMW-VSP-STD-3A VMware vSphere 6 Standard (1 CPU), 3-yr, Support Required
VMW-VSP-EPL-3A VMware vSphere 6 Ent Plus (1 CPU), 3-yr, Support Required
VMW-VSP-EPL-1A VMware vSphere 6 Ent Plus (1 CPU), 1-yr, Support Required
VMW-VSP-STD-5A VMware vSphere 6 Standard (1 CPU), 5-yr, Support Required
SLES SAP
SLES-SAP-2S2V-1S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 1-Yr SnS

72 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 34 Software (for 2-CPU servers) (continued)

PID Description Product ID (PID)


SLES-SAP-2SUV-1S SLES for SAP Apps (1-2 CPU, Unl VM); Priority 1-Yr SnS
SLES-SAP-2S2V-3S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 3-Yr SnS
SLES-SAP-2SUV-3S SLES for SAP Apps (1-2 CPU, Unl VM); Priority 3-Yr SnS
SLES-SAP-2S2V-5S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 5-Yr SnS
SLES-SAP-2SUV-5S SLES for SAP Apps (1-2 CPU, Unl VM); Priority 5-Yr SnS
SLES-SAP-2S2V-5A SLES for SAP Apps (1-2 CPU, 1-2 VM); 5-Yr Support Reqd
SLES-SAP-2SUV-3A SLES for SAP Apps (1-2 CPU, Unl VM); 3-Yr Support Reqd
SLES-SAP-2S2V-3A SLES for SAP Apps (1-2 CPU, 1-2 VM); 3-Yr Support Reqd
SLES-SAP-2SUV-5A SLES for SAP Apps (1-2 CPU, Unl VM); 5-Yr Support Reqd
SLES-SAP-2S2V-1A SLES for SAP Apps (1-2 CPU, 1-2 VM); 1-Yr Support Reqd
SLES-SAP-2SUV-1A SLES for SAP Apps (1-2 CPU, Unl VM); 1-Yr Support Reqd
SUSE
SLES-2S2V-1A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 1-Yr Support Req
SLES-2SUV-1A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); 1-Yr Support Req
SLES-2S2V-3A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 3-Yr Support Req
SLES-2SUV-3A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); 3-Yr Support Req
SLES-2S2V-5A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 5-Yr Support Req
SLES-2SUV-5A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); 5-Yr Support Req
SLES-2S2V-1S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 1-Yr SnS
SLES-2SUV-1S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); Prio 1-Yr SnS
SLES-2S2V-3S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 3-Yr SnS
SLES-2SUV-3S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); Prio 3-Yr SnS
SLES-2S2V-5S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 5-Yr SnS
SLES-2SUV-5S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM); Prio 5-Yr SnS
SLES-2S-HA-1S SUSE Linux High Availability Ext (1-2 CPU); 1yr SnS
SLES-2S-HA-3S SUSE Linux High Availability Ext (1-2 CPU); 3yr SnS
SLES-2S-HA-5S SUSE Linux High Availability Ext (1-2 CPU); 5yr SnS
SLES-2S-GC-1S SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Sns
SLES-2S-GC-3S SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr SnS
SLES-2S-GC-5S SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr SnS

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 73
CONFIGURING the SERVER

STEP 20 SELECT OPERATING SYSTEM MEDIA KIT


Select the optional operating system media listed in Table 35.

Table 35 OS Media

Product ID (PID) PID Description

RHEL-6 RHEL 6 Recovery Media Only (Multilingual)

SLES-11 SLES 11 media only (multilingual)

MSWS-08R2-STHV-RM Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media

MSWS-08R2-ENHV-RM Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media

MSWS-08R2-DCHV-RM Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media

MSWS-12-ST2S-RM Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media

MSWS-12-DC2S-RM Windows Server 2012 Datacenter(2 CPU/Unlimited VM) Rec Media

MSWS-12R2-ST2S-RM Windows Server 2012 R2 Standard (2 CPU/2 VMs) Recovery Media

MSWS-12R2-DC2S-RM Windows Server 2012 R2 Datacen(2 CPU/Unlimited VM) Rec Media

74 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 21 SELECT SERVICE and SUPPORT LEVEL


A variety of service options are available, as described in this section.

Unified Computing Warranty, No Contract

If you have noncritical implementations and choose to have no service contract, the following
coverage is supplied:

 Three-year parts coverage.


 Next business day (NBD) onsite parts replacement eight hours a day, five days a week.
 90-day software warranty on media.
 Ongoing downloads of BIOS, drivers, and firmware updates.
 UCSM updates for systems with Unified Computing System Manager. These updates include
minor enhancements and bug fixes that are designed to maintain the compliance of UCSM
with published specifications, release notes, and industry standards.

SMARTnet for UCS

For support of the entire Unified Computing System, Cisco offers the Cisco SMARTnet for UCS
Service. This service provides expert software and hardware support to help sustain
performance and high availability of the unified computing environment. Access to Cisco
Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world.

For UCS blade servers, there is Smart Call Home, which provides proactive, embedded
diagnostics and real-time alerts. For systems that include Unified Computing System Manager,
the support service includes downloads of UCSM upgrades. The Cisco SMARTnet for UCS Service
includes flexible hardware replacement options, including replacement in as little as two hours.
There is also access to Cisco's extensive online technical resources to help maintain optimal
efficiency and uptime of the unified computing environment. You can choose a desired service
listed in Table 36.

Table 36 Cisco SMARTnet for UCS Service

Product ID (PID) On Site? Description

CON-PREM-C240M4SX Yes ONSITE 24X7X2 UCS C240 M4 Server - SFF

CON-OSP-C240M4SX Yes ONSITE 24X7X4 UCS C240 M4 Server - SFF

CON-OSE-C240M4SX Yes ONSITE 8X5X4 UCS C240 M4 Server - SFF

CON-OS-C240M4SX Yes ONSITE 8X5XNBD UCS C240 M4 Server - SFF

CON-S2P-C240M4SX No SMARTNET 24X7X2 UCS C240 M4 Server - SFF

CON-SNTP-C240M4SX No SMARTNET 24X7X4 UCS C240 M4 Server - SFF

CON-SNTE-C240M4SX No SMARTNET 8X5X4 UCS C240 M4 Server - SFF

CON-SNT-C240M4SX No SMARTNET 8X5XNBD UCS C240 M4 Server - SFF

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 75
CONFIGURING the SERVER

SMARTnet for UCS Hardware Only Service

For faster parts replacement than is provided with the standard Cisco Unified Computing System
warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from
two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet
for UCS Hardware Only Service provides remote access any time to Cisco support professionals
who can determine if a return materials authorization (RMA) is required. You can choose a
service listed in Table 37.

Table 37 SMARTnet for UCS Hardware Only Service

Service On
Product ID (PID) Description
Level GSP Site?

CON-UCW7-C240M4SX UCW7 Yes UC PLUS 24X7X4OS UCS C240 M4 Server - SFF

CON-UCW5-C240M4SX UCW5 Yes UC PLUS 8X5XNBDOS UCS C240 M4 Server - SFF

Unified Computing Partner Support Service

Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is
designed for partners to deliver their own branded support and managed services to enterprise
customers. Cisco PSS provides partners with access to Cisco's support infrastructure and assets
to help them:

 Expand their service portfolios to support the most complex network environments
 Lower delivery costs
 Deliver services that increase customer loyalty

Partner Unified Computing Support Options enable eligible Cisco partners to develop and
consistently deliver high-value technical support that capitalizes on Cisco intellectual assets.
This helps partners to realize higher margins and expand their practice.

PSS is available to all Cisco PSS partners, but requires additional specializations and
requirements. For additional information, see the following URL:

www.cisco.com/go/partnerucssupport

The two Partner Unified Computing Support Options include:

 Partner Support Service for UCS


 Partner Support Service for UCS Hardware Only

76 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Partner Support Service for UCS provides hardware and software support, including triage
support for third party software, backed by Cisco technical resources and level three support.
See Table 38.

Table 38 Partner Support Service for UCS

Service
On
Product ID (PID) Level Description
Site?
GSP

CON-PSJ1-C240M4SX PSJ1 No UCS SUPP PSS 8X5XNBD UCS C240 M4 Server - SFF

CON-PSJ2-C240M4SX PSJ2 No UCS SUPP PSS 8X5X4 UCS C240 M4 Server - SFF

CON-PSJ3-C240M4SX PSJ3 No UCS SUPP PSS 24X7X4 UCS C240 M4 Server - SFF

CON-PSJ4-C240M4SX PSJ4 No UCS SUPP PSS 24X7X2 UCS C240 M4 Server - SFF

Partner Support Service for UCS Hardware Only provides customers with replacement parts in as
little as two hours. See Table 39.

Table 39 Partner Support Service for UCS (Hardware Only)

Service
On
Product ID (PID) Level Description
Site?
GSP

CON-PSW2-C240M4SX PSW2 No UCS W PL PSS 8X5X4 UCS C240 M4 Server - SFF

CON-PSW3-C240M4SX PSW3 No UCS W PL PSS 24X7X4 UCS C240 M4 Server - SFF

CON-PSW4-C240M4SX PSW4 No UCS W PL PSS 24X7X2 UCS C240 M4 Server - SFF

Unified Computing Combined Support Service

Combined Services makes it easier to purchase and manage required services under one
contract. SMARTnet services for UCS help increase the availability of your vital data center
infrastructure and realize the most value from your unified computing investment. The more
benefits you realize from the Cisco Unified Computing System (Cisco UCS), the more important
the technology becomes to your business. These services allow you to:

 Optimize the uptime, performance, and efficiency of your UCS


 Protect your vital business applications by rapidly identifying and addressing issues
 Strengthen in-house expertise through knowledge transfer and mentoring
 Improve operational efficiency by allowing UCS experts to augment your internal staff
resources
 Enhance business agility by diagnosing potential issues before they affect your operations

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 77
CONFIGURING the SERVER

You can choose a service listed in Table 40.

Table 40 UCS Computing Combined Support Service

Service
On
Product ID (PID) Level Description
Site?
GSP

CON-NCF2-C240M4SX NCF2 No CMB SPT SVC 24X7X2 UCS C240 M4 Server - SFF

CON-NCF2P-C240M4SX NCF2P Yes CMB SPT SVC 24X7X2OS UCS C240 M4 Server - SFF

CON-NCF4P-C240M4SX NCF4P Yes CMB SPT SVC 24X7X4OS UCS C240 M4 Server - SFF

CON-NCF4S-C240M4SX NCF4S Yes CMB SPT SVC 8X5X4OS UCS C240 M4 Server - SFF

CON-NCFCS-C240M4SX NCFCS Yes CMB SPT SVC 8X5XNBDOS UCS C240 M4 Server - SFF

CON-NCFE-C240M4SX NCFE No CMB SPT SVC 8X5X4 UCS C240 M4 Server - SFF

CON-NCFP-C240M4SX NCFP No CMB SPT SVC 24X7X4 UCS C240 M4 Server - SFF

CON-NCFT-C240M4SX NCFT No CMB SPT SVC 8X5XNBD UCS C240 M4 Server - SFF

Unified Computing Drive Retention Service

With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk
drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco
replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the
drive has been removed from the system listed, is no longer in service, and has been destroyed.

Sophisticated data recovery techniques have made classified, proprietary, and confidential
information vulnerable, even on malfunctioning disk drives. The UCDR service enables you to
retain your drives and ensures that the sensitive data on those drives is not compromised, which
reduces the risk of any potential liabilities. This service also enables you to comply with
regulatory, local, and federal requirements.

If your company has a need to control confidential, classified, sensitive, or proprietary data, you
might want to consider one of the Drive Retention Services listed in Table 41 on page 79.

NOTE: Cisco does not offer a certified drive destruction service as part of this
service.

78 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 41 Drive Retention Service Options

Service Service
Service Description Service Level Product ID (PID)
Program Name Level GSP

SMARTnet for UCS UCSD7 24x7x4 Onsite CON-UCSD7-C240M4SX


Service with Drive UCS DR
Retention UCSD5 8x5xNBD Onsite CON-UCSD5-C240M4SX

SMARTnet for UCS UCWD7 24x7x4 Onsite CON-UCWD7-C240M4SX


HW ONLY+Drive UCS HW+DR
Retention UCWD5 8x5xNBD Onsite CON-UCWD5-C240M4SX

For more service and support information, see the following URL:

http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.pdf

For a complete listing of available services for Cisco Unified Computing System, see this URL:

http://www.cisco.com/en/US/products/ps10312/serv_group_home.html

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 79
OPTIONAL STEP - ORDER RACK(s)

OPTIONAL STEP - ORDER RACK(s)


The optional R42612 rack is available from Cisco for the C-Series servers, including the C240 M4
SFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as
listed in Table 42. Racks are shipped separately from the C240 M4 SFF server.

Table 42 Racks and Rack Options

Product ID (PID) PID Description


RACK2-UCS Cisco R42612 expansion rack, no side panels. 

This type of rack is used for multiple-rack deployments.
RACK2-UCS2 Cisco R42612 static (standard) rack, with side panels. 

This type of rack is used for single-rack and end of row deployments.
Side panels are needed for racks at the ends of multiple-rack
deployments. For example, when configuring a row of 5 racks, order
1 standard rack plus 4 expansion racks. Apply the side panels from
the standard rack to the racks at each end of the row.
RACK-BLANK-001 Blanking panels (qty 12), 1U, plastic, toolless.

Recommended to ensure proper airflow. Fill all empty RU spaces in
the front of the rack. Because each blanking panel PID includes 12
panels, use the following calculation: 42RU - occupied RU = available
RU. Divide available RU by 12 to determine PID order quantity.
RACK-CBLMGT-001 Cable mgt D rings (qty 10), metal.

Use the D rings to bundle system cables to ensure proper airflow.
RACK-CBLMGT-003 Brush strip (qty 1), 1 U.

The brush strip promotes proper airflow while allowing cables to be
passed from the front to the rear of the rack.
RACK-CBLMGT-011 Cable mgt straps (qty 10), Velcro.

Use the Velcro straps to bundle system cables to ensure proper
airflow.
RACK-FASTEN-001 Mounting screws (qty 100), M6.

The rack ships with nuts and screws, but extras may be ordered.
RACK-FASTEN-002 Cage nuts (qty 50), M6.

The rack ships with nuts and screws, but extras may be ordered.
RACK2-JOIN-001 Rack joining kit.

Use the kit to connect adjacent racks within a row. Order 1 unit less
than the number of racks in the row.
RACK2-GRND-001 Cisco R42612 grounding kit

For more information about the R42612 rack, see RACKS, page 102.

80 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
OPTIONAL STEP - ORDER PDU

OPTIONAL STEP - ORDER PDU


An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers,
including the C240 M4 server. This PDU is available in a zero rack unit (RU) style or horizontal
PDU style (see Table 43).For more information about the PDU, see PDUs, page 104.

Table 43 Available PDUs

Product ID (PID) Description Plug Country

Zero-RU PDUs

RP208-30M1P-6-36 30 A, single-phase, L6-30P North America


vertical-mount PDU with 6 C19
and 36 C13 connectors

RP208-30M3P-6-30 30 A, three-phase, L15-30P North America


vertical-mount PDU with 6 C19
and 30 C13 connectors

RP208-60M3P-12-9 60 A, three-phase, IEC60309 North America


vertical-mount PDU with 12 C19 460P9
and 9 C13 connectors

RP230-32M1P-6-36 32 A, single-phase, IEC60309 International


button-mount (rear and sides) 332P6
PDU with 6 C19 and 36 C13
connectors

RP230-32M3P-12-12 32 A, single-phase, IEC60309 International


button-mount (rear and sides)
532P6
PDU with 12 C19 and 12 C13
connectors

Horizontal PDUs (occupy RU space)

RP208-30M1P-4-8 30 A, single-phase, L6-30P North America


(1 RU space) horizontal-mount PDU with 4 C19
and 8 C13 connectors

RP208-60M3P-12 48 A, three-phase, L15-30P North America


(2 RU spaces) horizontal-mount PDU with 12
C19 connectors

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 81
SUPPLEMENTAL MATERIAL

SUPPLEMENTAL MATERIAL
CHASSIS
An internal view of the C240 M4 chassis with the top cover removed is shown in Figure 9.

Figure 9 C240 M4 SFF With Top Cover Off

2 3 4 5 6

7
FAN 06 FAN 05 FAN 04 FAN 03 FAN 02 FAN 01

SD2
SD1
CPU 2
8

1 9
Riser 2

10
CPU 1

Riser 1
11

352948
17 16 15 14 13 12

1 Drives  10 PCIe riser 1 (PCIe slots 1, 2, 3*)


(hot-swappable, accessed through front panel)
*Slot 3 not present in all versions. See
Riser Card Configuration and Options,
page 93 for riser options and slot
specifications.

2 Fan modules (six, hot-swappable) 11 SATA boot drives (two sockets available
only on PCIe riser 1 option C)

3 DIMM sockets on motherboard  12 mLOM card socket on motherboard under


(up to 24 DIMMs) PCIe riser 1

4 CPUs and heatsinks (two) 13 Socket for embedded RAID interposer


board

5 Cisco SD card slots on motherboard (two) 14 Cisco modular RAID controller PCIe slot
(dedicated slot and bracket)

82 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

6 USB 3.0 slot on motherboard 15 RTC battery on motherboard

7 Power supplies 16 Embedded RAID header for RAID key


(hot-swappable, accessed through rear panel)

8 Trusted platform module (TPM) socket on 17 SuperCap power module (RAID backup)
motherboard, under PCIe riser 2 mounting location on air baffle 
(not shown)

9 PCIe riser 2 (PCIe slots 4, 5, 6)

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 83
Cisco C240 M4 2U Server System Block Diagram Rear Panel

84
USB USB
Four Options for Drive Backplane Thumbdrive
USB

Figure 10
UCSC-C240-M4S, 2U, 8-2.5" drives USB 3.0
VGA
1 SAS x4 SATA Serial
2 Cables to
3 modular X2 AHCI

X4 SAS
X4 SAS
RAID card or
Intel PCIe 2-port 1 GB-T

Connector
Connector
4
Wellsburg Gen2 Wellsburg PCH i350 NIC
SATA 1 GB-T
Block Diagram

5 connectors (6 Gb/s)
6 or PCIe
PCIe
7 Interposer* 1 GB-T
SUPPLEMENTAL MATERIAL

X4 SAS
X4 SAS
GbE switch

Connector
Connector
8
SAS x4
BMC (Mgmt)

UCSC-C240-M4S2, 2U, 16-2.5" drives SD controller


SAS x4
1 DMI2 (x4) SD 3.0
Gen2
Cables to A1A2 A3 SD1 SD2
modular
mLOM

X4 SAS
2

Connector
. . RAID card Chan A Module
. . connectors DMI2 (a variety of
B1B2 B3

24-port
. . or PCIe network cards can

SAS Expander
. . Interposer* Chan B PCIe x8 be installed here)

X4 SAS
Intel Gen 3

Connector
16
Network connectors

SAS x4 C1C2 C3 Xeon


PCIe x8
Chan C Haswell XP
(types vary with mLOM module)

. . . . . . . . . . . .

(CPU 1) Gen 3 slot


D1D2 D3
UCSC-C240-M4SX, 2U, 24-2.5" drives Chan D
C240 M4 SFF Block Diagram (simplified)

SAS x4
1 PCIe Riser 1 (option 1)
QPI (9.6 GT) QPI (9.6 GT)
Cables to
E1 E2 E3 Slot 2 Front Panel

X4 SAS
2 Modular PCIe x16 Gen3

Connector
. . RAID card Chan E Slot 1
PCIe x8 Gen3
. . connectors

36-port
. . or PCIe F1 F2 F3

SAS Expander
. . Interposer* Chan F PCIe Riser 1 (option 2)
Intel

X4 SAS
Slot 3 X2 USB 2.0

Connector
24 Xeon PCIe x8 Gen3
SAS x4 G1G2 G3 Slot 2 1 VGA
Haswell XP PCIe x8 Gen3
Chan G Slot 1 1 Serial
*For PCIe drives in (CPU 2) PCIe x8 Gen3
slots 1 and 2 only
H1H2 H3
UCSC-C240-M4L, 2U, 12-3.5" drives
PCIe Riser 1 (option 3)
Chan H
SAS x4 SATA 1 SATA 2 KVM
X2 AHCI
1 Connector
SAS/SATA PCIe x16 Gen3 Slot 2
PCIe x8 Gen 3
PCIe x8 Gen3 Slot 1
PCIe x8 Gen 3

X4 SAS
2 Cables to

Connector
A simplified block diagram of the C240 M4 server is shown in Figure 10.

. . PCIe Interposer

X4 SAS
modular Modular

Connector
. . Gen3 (optional) PCIe Riser 2
RAID card

20-port
. . connectors (12 Gb/s) SAS/SATA RAID Card PCIe x8 Gen3 Slot 6

SAS Expander
. .

X4 SAS
X2 mini PCIe x16 Gen3 Slot 5

Connector
12 SAS HD
Slot 4

X4 SAS
SAS x4 PCIe x8 Gen3

Connector
PCIe x4 Gen3
PCIe x4 Gen3

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

CPUs and DIMMs

Physical Layout
Each CPU has four DIMM channels:

 CPU1 has channels A, B, C, and D


 CPU2 has channels E, F, G, and H

Each DIMM channel has three slots: slot 1, slot 2, and slot 3. The blue-colored DIMM slots are for slot 1, the
black-colored slots for slot 2, and the white slots for slot 3.

As an example, DIMM slots A1, B1, C1, and D1 belong to slot 1, while A2, B2, C2, and D2 belong to slot 2.

Figure 11 shows how slots and channels are physically laid out on the motherboard. The DIMM slots on the
right half of the motherboard (channels A, B, C, and D) are associated with CPU 1, while the DIMM slots on
the left half of the motherboard (channels E, F, G, and H) are associated with CPU 2. The slot 1 (blue) DIMM
slots are always located farther away from a CPU than the corresponding slot 2 (black) and slot 3 (white)
slots. Slot 1 slots (blue) are populated before slot 2 slots (black) and slot 3 (white) slots.

Figure 11 Physical Layout of CPU DIMM Channels and Slots

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 85
SUPPLEMENTAL MATERIAL

Memory Population Rules


When considering the memory configuration of your server, consider the following items:

 Each channel has three DIMM slots (for example, channel A = slots A1, A2, and A3).
— A channel can operate with one, two, or three DIMMs installed.
— If a channel has only one DIMM, populate slot 1 first (the blue slot).
 When both CPUs are installed, populate the DIMM slots of each CPU identically.
— Fill blue slots in the channels first: A1, E1, B1, F1, C1, G1, D1, H1
— Fill black slots in the channels second: A2, E2, B2, F2, C2, G2, D2, H2
— Fill white slots in the channels third: A3, E3, B3, F3, C3, G3, D3, H3
 Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized.
 Observe the DIMM mixing rules shown in Table 44

Table 44 DIMM Rules for C240 M4 Servers

DIMM Parameter DIMMs in the Same Channel DIMM in the Same Slot1

DIMM Capacity
RDIMM = 8, 16, or 32 GB DIMMs in the same channel (for For best performance, DIMMs in the
example, A1, A2, and A3) can have same slot (for example, A1, B1, C1,
LRDIMM = 32 or 64 GB
different capacities. D1) should have the same capacity.
TSV-RDIMM = 64 GB
 
Do not mix TSV-RDIMMS with Do not mix TSV-RDIMMS with LRDIMMs
LRDIMMs nor RDIMMs nor RDIMMs

DIMM Speed
2400-MHz DIMMs will run at the lowest speed DIMMs will run at the lowest speed of
of the CPU installed the CPU installed
2133-MHz

DIMM Type
TSV-RDIMMS, RDIMMs, or Do not mix DIMM types in a channel Do not mix DIMM types in a slot
LRDIMMs

1 DPC, 2 DPC, or 3 DPC


DIMMs per Channel (DPC)
See Table 8 on page 24 for 
valid LRDIMM and RDIMM 1 DPC, 2 DPC, and 3 DPC memory configurations

Notes . . .
1. Although different DIMM capacities can exist in the same slot, this will result in less than optimal performance.
For optimal performance, all DIMMs in the same slot should be identical.

86 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

DIMM Population Order


Populate the DIMMs for a CPU according to Table 45.

Table 45 DIMM Population Order per CPU

DIMMs per Populate  Populate 


CPU CPU 1 Slots CPU 2 Slots

1 A1 E1

2 A1, B1 E1, F1

3 A1, B1, C1 E1, F1, G1

4 A1, B1, C1, D1 E1, F1, G1, H1

8 A1, B1, C1, D1, E1, F1, G1, H1,


A2, B2, C2, D2 E2, F2, G2, H2

12 A1, B1, C1, D1, E1, F1, G1, H1,


A2, B2, C2, D2 E2, F2, G2, H2
A3, B3, C3, D3 E3, F3, G3, H3

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 87
SUPPLEMENTAL MATERIAL

Recommended Memory Configuration


This section explains the recommended DIMM population order rules for the C240 M4 server.
 All DIMMs must be DDR4 DIMMs.
 Do not mix:
— DIMMs with different clock rates in a channel
— RDIMMs and LRDIMMs
 There are blue, black, and white DIMM slots. Populate blue slots first.
 When DIMMs ranks are mixed in the same channel, always populate the highest rank DIMM in
the blue DIMM slot and lower rank DIMM(s) in the black and white DIMM slots.
Many memory configurations are possible. For best results, follow Table 46 when populating 2133-MHz
DIMMs for Intel Xeon E5-2600 v3 CPUs and Table 47 when populating 2400-MHz DIMMs for Intel Xeon E5-2600
v4 CPUs.

NOTE: These tables list only some recommended and suggested configurations.
There are numerous other possible configurations supported by Cisco. Cisco supports
all mixing and population configurations of the Cisco DIMMs as long as the mixing
does not violate the few fundamental rules noted in this document.

Table 46 Recommended Memory Configurations for Intel Xeon E5-2600 v3 CPUs (with 2133-MHz DIMMs)1

CPU 1 DIMMs CPU 2 DIMMs


Total
System Blue Slots Black Slots White Slots Blue Slots Black Slots White Slots DIMM Max Total
Slot 1 Slot 2 Slot 3 Slot 1 Slot 2 Slot 3 Speed
Memory DIMMs
(A1,B1, (A2,B2, (A3,B3, (E1,F1, (E2,F2, (E3,F3, (MHz)
Size
C1,D1) C2,D2) C3,D3) G1,H1) G2,H2) G3,H3)
64 GB 4x8 GB — — 4x8 GB — — 2133 8

128 GB 4x8 GB 4x8 GB — 4x8 GB 4x8 GB — 2133 16

4x16 GB — — 4x16 GB — — 2133 8

192 GB 4x8 GB 4x8 GB 4x8 GB 4x8 GB 4x8 GB 4x8 GB 1600 24

4x16 GB 4x8 GB — 4x16 GB 4x8 GB — 2133 16

256 GB 4x16 GB 4x16 GB — 4x16 GB 4x16 GB — 2133 16

4x32 GB — — 4x32 GB — — 2133 8

384 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 1866 24

512 GB 4x32 GB 4x32 GB — 4x32 GB 4x32 GB — 2133 16

4x64 GB — — 4x64 GB — — 2133 8

768 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 1866 24

1024 GB 4x64 GB 4x64 GB — 4x64 GB 4x64 GB — 2133 16

1536 GB 4x64 GB 4x64 GB 4x64 GB 4x64 GB 4x64 GB 4x64 GB 1600 24

88 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

Notes . . .
1. Rows marked in yellow indicate best performance.

Table 47 Recommended Memory Configurations for Intel Xeon E5-2600 v4 CPUs (with 2400-MHz DIMMs)1
CPU 1 DIMMs CPU 2 DIMMs
Total
System Blue Slots Black Slots White Slots Blue Slots Black Slots White Slots DIMM Max Total
Slot 1 Slot 2 Slot 3 Slot 1 Slot 2 Slot 3 Speed
Memory DIMMs
(A1,B1, (A2,B2, (A3,B3, (E1,F1, (E2,F2, (E3,F3, (MHz)
Size
C1,D1) C2,D2) C3,D3) G1,H1) G2,H2) G3,H3)
64 GB 4x8 GB — — 4x8 GB — — 2400 8

128 GB 4x8 GB 4x8 GB — 4x8 GB 4x8 GB — 2400 16

4x16 GB — — 4x16 GB — — 2400 8

192 GB 4x8 GB 4x8 GB 4x8 GB 4x8 GB 4x8 GB 4x8 GB 2133 24

4x16 GB 4x8 GB — 4x16 GB 4x8 GB — 2133 16

256 GB 4x16 GB 4x16 GB — 4x16 GB 4x16 GB — 2400 16

4x32 GB — — 4x32 GB — — 2400 8

320 GB 4x32 GB 4x8 GB — 4x32 GB 4x8 GB — 2133 16

384 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 2133 24

4x32GB 4x16GB — 4x32GB 4x16GB — 2133 16

512 GB 4x32 GB 4x32 GB — 4x32 GB 4x32 GB — 2400 16

4x64 GB — — 4x64 GB — — 2400 8

768 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 1866 24

1024 GB 4x64 GB 4x64 GB — 4x64 GB 4x64 GB — 2400 16

1536 GB 4x64 GB 4x64 GB 4x64 GB 4x64 GB 4x64 GB 4x64 GB 2133 24

Notes . . .
1. Rows marked in yellow indicate best performance.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 89
SUPPLEMENTAL MATERIAL

Additional DIMM Populations


The list in Table 48 is not a complete list of all supported DIMM populations, but highlights common
configuration options.

Table 48 Supported DIMM Configurations

Total
Total DIMMs CPU 1 Total DIMMs CPU 2
CPU 1 DIMMs CPU 2 DIMMs Capacity for
for CPU 1 Capacity for CPU 2 Capacity
2 CPUs
1 x 8 GB 1 8 GB 1 x 8 GB 1 8 GB 16 GB
2 x 8 GB 2 16 GB 2 x 8 GB 2 16 GB 32 GB
1 x 16 GB 1 16 GB 1 x 16 GB 1 16 GB 32 GB
4 x 8 GB 4 32 GB 4 x 8 GB 4 32 GB 64 GB
2 x 16 GB 2 32 GB 2 x 16 GB 2 32 GB 64 GB
1 x 32 GB 1 32 GB 1 x 32 GB 1 32 GB 64 GB
8 x 8 GB 8 64 GB 8 x 8 GB 8 64 GB 128 GB
4 x 16 GB 4 64 GB 4 x 16 GB 4 64 GB 128 GB
2 x 32 GB 2 64 GB 2 x 32 GB 2 64 GB 128 GB
12 x 8 GB 12 96 GB 12 x 8 GB 12 96 GB 192 GB
8 x 16 GB 8 128 GB 8 x 16 GB 8 128 GB 256 GB
4 x 32 GB 4 128 GB 4 x 32 GB 4 128 GB 256 GB
12 x 16 GB 12 192 GB 12 x 16 GB 12 192 GB 384 GB
8 x 32 GB 8 256 GB 8 x 32 GB 8 256 GB 512 GB
12 x 32 GB 12 384 GB 12 x 32 GB 12 384 GB 768 GB
12 x 64 GB 12 768 GB 12 x 64 GB 12 768 GB 1536 GB

90 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

RAID Details
The available disk drive support configurations are shown in this section.

NOTE: You can select a Cisco 12G Modular RAID controller or a Cisco 12 Gbps
Modular SAS HBA, but not both at the same time.

By default, the server comes with embedded software RAID.

To upgrade from the default, select one of these:

Cisco 12G SAS Modular RAID Controller (RAID Support)


 For a 24-drive or 16-drive backplane system, select one of the following:
— Cisco 12G SAS Modular RAID controller from Table 11 on page 31, or
— Cisco 9300-8E 12G SAS HBA from Table 11 on page 31, or
— One Cisco 12G SAS Modular RAID controller and one or two Cisco 9300-8E 12G SAS
HBAs from Table 11 on page 31.

Select an appropriate optional RAID configuration listed in Table 11 on page 31.

 For an 8-drive backplane system, select one of the following:


— Embedded software RAID 5 key upgrade option from Table 11 on page 31, or
— Cisco 12G SAS Modular RAID controller from Table 11 on page 31, or
— Cisco 9300-8E 12G SAS HBA from Table 11 on page 31
— One Cisco 12G SAS Modular RAID controller from Table 11 on page 31 and one or
two Cisco 9300-8E 12G SAS HBAs from Table 11 on page 31

Select an appropriate optional RAID configuration listed in Table 11 on page 31.

Cisco 12 Gbps SAS HBA (JBOD Only Support)


 Select one of the following:
— Cisco 12 Gbps Modular SAS HBA from Table 11 on page 31, and/or
— One or two Cisco 9300-8E 12G SAS HBAs from Table 11 on page 31, or

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 91
SUPPLEMENTAL MATERIAL

RAID Option ROM (OPROM) Settings


The server contains an Option ROM (OPROM) for the PCIe slots. The server has a finite amount of option
ROM with which it can boot up devices. Go into the BIOS and disable the OPROM on the PCIe slots not used
for booting so that resources are available for the slots that are used for booting. An example OPROM BIOS
screen is shown in Figure 12.

Figure 12 Example BIOS Screen for OPROM

92 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

Riser Card Configuration and Options


The three riser card 1 options are shown in Table 49. The number of PCIe card slots and connectors for
SATA boot drives depends on which option is selected for riser 1. The riser card 2 slot assignments are fixed
and are shown in Table 50 on page 94.

Table 49 Riser Card 1 Slot Options

Slot # Height Length Electrical Mechanical NCSI Physical


Riser Card 1 (option A, PID UCSC-PCI-1A-240M4)

Slot 2
Slot 1

3 No slot available
2 Full Full1 x16 x24 Yes2
1 Full 3/4 x8 x24 Yes2
Riser Card 1 (option B, PID UCSC-PCI-1B-240M4)3

Slot 3
Slot 2
Slot 1

3 Full Full x8 x16 No


2 Full Full x8 x24 Yes
1 Full 3/4 x8 x16 No
Riser Card 1 (option C, PID UCSC-PCI-1C-240M4)
SATA boot drive connectors (2)

Slot 2
Slot 1

3 No slot available4
2 Full Full x16 x24 Yes2
1 Full 3/4 x8 x24 Yes

Notes . . .
1. GPU capable slot
2. NCSI supported in only one slot at a time (default slot 2). If a GPU card is present in slot 2, NCSI support
automatically moves to slot 1.
3. No GPUs are supported on this riser. There is no GPU power connector in this version. Use riser version 1A for
GPU cards.
4. There is no PCIe connector in slot 3; instead, there are two connectors available for connecting SATA boot
drives.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 93
SUPPLEMENTAL MATERIAL

Table 50 Riser Card 2 Slots

Slot # Height Length Electrical Mechanical NCSI Physical

Riser Card 2

Slot 6
Slot 5
Slot 4

6 Full Full x8 x16 No

5 Full Full1 x16 x24 Yes2

4 Full 3/4 x8 x24 Yes2

Notes . . .
1. GPU capable slot
2. NCSI supported in only one slot at a time (default slot 5). If a GPU card is present in slot 5, NCSI support
automatically moves to slot 4.

94 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

Embedded SATA RAID: Two SATA Controllers


The embedded SATA RAID controller hub is split into two controllers, SATA and sSATA (secondary SATA).
These two controllers are seen as separate RAID controllers in the Cisco IMC interface and are configurable
separately.

 The first SATA controller controls drives 1–4; the secondary sSATA controller controls drives 5–8.
 When configuring RAID groups, you cannot create a group that spans more than four drives.
 The first SATA controller can control a RAID group of up to four drives, consisting only of
drives 1–4.
 The secondary sSATA controller can control a RAID group of up to four drives, consisting only
of drives 5–8. See Figure 13.

Figure 13 Embedded RAID Controller RAID Groups

HDD01 HDD02
HDD03 HDD04
HDD05 HDD06
HDD07 HDD08

SATA RAID Controller Hub

SATA sSATA

 Each controller is listed separately in the BIOS. You can select the boot order of the
controllers in the BIOS (use the Boot Options tab in the BIOS Setup Utility).

Note the following considerations:

 The default setting for this embedded controller hub is SATA RAID 0, 1, and 10 support for up to
eight SATA drives (in two groups of four drives).
 You can upgrade this to support to SATA RAID 0, 1, 10, and 5 support for up to eight SATA drives (in
two groups of four drives) by installing a RAID 5 key module on the motherboard.
 When you order the server with this embedded controller, the controller is enabled in the BIOS.
 You cannot downgrade from using a HW RAID controller card to using the SW RAID embedded
controller.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 95
SUPPLEMENTAL MATERIAL

To Create a RAID Group

(1) While the server is booting, wait for the prompt and press function key F2 as shown in
Figure 14.

Figure 14 Function Key F2 Prompt

In a few seconds, you will see the screen that allows you to set up a RAID group for the primary
SATA controller (see Figure 15).

Figure 15 Screen to Configure Primary SATA RAID Group

96 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

(2) Press Ctrl+M to start the RAID group creation process for the primary SATA controller (for
drives 1-4, as shown in Figure 13 on page 95). Or, do nothing and wait for the next screen,
which allows you to create a RAID group for the secondary SATA (sSATA) controller see
Figure 16).

Figure 16 Screen to Configure Secondary SATA (sSATA) RAID Group

(3) Press Ctrl+M to start the RAID group creation process for the secondary SATA (sSATA)
controller (for drives 5-8, as shown in Figure 13 on page 95).

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 97
SUPPLEMENTAL MATERIAL

Serial Port Details


The pinout details of the rear RJ-45 serial port connector are shown in Figure 17.

Figure 17 Serial Port (Female RJ-45 Connector) Pinout

Serial Port (RJ-45 Female Connector)

Pin Signal
1 RTS (Request to Send)
2 DTR (Data Terminal Ready)
3 TxD (Transmit Data)
4 GND (Signal Ground)
5 GND (Signal Ground)
6 RxD (Receive Data)
7 DSR (Data Set Ready)
8 CTS (Clear to Send)

98 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

Upgrade and Servicing-Related Parts


This section lists the upgrade and servicing-related parts you may need during the life of your server. Some
of these parts are configured with every server, and some may be ordered when needed or may be ordered
and kept on hand as spares for future use. See Table 51.

Table 51 Upgrade and Servicing-related Parts for UCS C240 M4 SFF Server

Spare Product ID (PID) Description


UCSC-PCIF-01F= PCIe Full Height blanking panel for UCS C-Series Server1
UCSC-PCIF-C240M4= C240 M4 PCIe Riser Blanking Panel1
UCSC-PCI-2-C240M4= C240 M4 PCIe Riser 2 Assembly1
UCSC-PCI-1A-240M4= C240 M4 PCIe Riser 1 Assembly (x8 slot + GPU)1
UCSC-PCI-1B-240M4= C240 M4 PCIe Riser 1 Assembly (3 x8 slots)1
UCSC-PCI-1C-240M4= C240 M4 PCIe Riser 1 Assembly (SATA Boot + 2 PCIe slots)1
UCSC-IP-SSD-240M4= PCIe interposer board + cable for PCIe SSD (8 and 16 HDD backplane versions)1
UCSC-IPSSD-240M48= PCIe interposer board + cable for PCIe SSD (24 HD backplane version)1
UCSC-IP-PCH-240M4= Interposer board + cables for onboard PCH SATA 6G Embedded Software RAID1
UCSC-MLOM-BLK= MLOM Blanking Panel
UCS-240CBLMR8= C240 M4 (2) RAID controller cables for 8 HD backplane2
UCS-240CBLMR16= C240 M4 (2) RAID controller cables for 16 HD backplane2
UCS-240CBLMR24= C240 M4 (2) RAID controller cables for 24 HD backplane2
UCSC-HS-C240M4= Heat Sink for UCS C240 M4 Rack Server1
UCS-CPU-CVR-EP-M4= CPU load plate dust cover (for unpopulated CPU sockets)
UCSC-GPUCBL-240M4= C240 M4 GPU Power Cable (1 cable per GPU card)1
N20-MBLIBATT= Replacement Lithium Battery for Server Motherboard (CR2032)1
UCSC-FAN-C240M4= C240 M4 Fan Module (one)
UCSC-BAFF-C240M4= C240 M4 Air Baffle Replacement Kit
UCSC-PSU-BLKP240= Power Supply Blanking Panel for C240 M4 Servers1
UCSC-RAILB-M4= Tool-Less Ball Bearing Rail Kit for C220 M4 and C240 M4 rack servers
UCSC-CMAB-M4= Reversible CMA for C240 M4 ball bearing rail kit
UCS-SD-32G-S= 32 GB SD Card for UCS servers3
UCS-SD-64G-S= 64 GB SD Card for UCS servers2
UCS-USBFLSHB-16GB= UCS Servers 16 GB Flash USB Drive
N20-BKVM= KVM local IO cable for UCS servers console port
UCS-CPU-GREASE3= M4 Server CPU thermal grease syringe - needed for heatsink seal4
UCSX-HSCK= UCS Processor Heat Sink Cleaning Kit (when replacing a CPU)3
UCSC-MRAID-SC= SuperCap for Cisco 12G SAS Modular RAID, including all cables.
UCSC-IP-SSD-240M4= PCIe 8639 interposer board + cable for PCIe SSD (8&16 HD)

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 99
SUPPLEMENTAL MATERIAL

Table 51 Upgrade and Servicing-related Parts for UCS C240 M4 SFF Server

Spare Product ID (PID) Description


UCSC-IPSSD-240M4B= PCIe 8639 interposer board + cable for PCIe SSD (24 HD)
UCS-300WKIT-240M4= 300 Watt Cable, HS and Kit for UCS C240M4 Rack Server Includes two heat sinks
and two power cables
Notes . . .
1. This part is included/configured with your UCS server (in some cases, as determined by the configuration of
your server).
2. Required if ordering the RAID controller as a spare or to replace damaged cables
3. This SD card is blank.
4. This part should be ordered with the purchase of each optional or spare Intel Xeon E5-2600 v3 CPU processor
kit

Adding an Additional CPU (with CPU heat sink) or Replacing CPUs


All Cisco UCS two CPU socket-capable servers can be upgraded from having one to having two CPUs
configured or can also support replacement of the CPUs. You will need to order and install a heat sink when
adding any additional CPU to a server. Instructions for installing the new CPU or replacing CPUs and heat
sink can be found at the following link:

http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C240M4/install/C240M4.html

NOTE: Unlike previous generation servers, the C240 M4 has tool-less CPU sockets, so
no separate tools (such as “pick n place” tools) are required to add or replace CPUs.

See the section titled “Replacing CPUs and Heatsinks.”

Motherboard Lithium Battery


You can order a replacement motherboard battery. Installation instructions are found at this link:

http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C240M4/install/C240M4.html

See the section titled “Replacing the Motherboard RTC Battery.”

Thermal Grease (with syringe applicator) for CPU to Heatsink Seal


Thermal grease must be applied to the top of the CPU where it comes in contact with the heat sink (a
grease syringe also ships with each CPU spare option kit). Instructions for applying thermal grease are found
at:

http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C240M4/install/C240M4.html

See the section titled “Replacing CPUs and Heatsinks.”

100 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

CAUTION: Use only the thermal grease specified for this server
(UCS-CPU-GREASE3=). This thermal grease comes in a white-tipped
syringe and is to be used only in the C220 M4 and C240 M4 servers. Other
servers use thermal grease in a blue-tipped syringe (UCS-CPU-GREASE=). 

Thermal grease for other systems may have different thermal
conductivity properties and may cause overheating if used in the C220 M4
or C240 M4 servers. 

DO NOT use thermal grease available for purchase at any commercial
electronics store. If these instructions are not followed, the CPU may
overheat and be destroyed.

NOTE: When you purchase a spare CPU, the thermal grease with syringe applicator
is included.

Air Baffle Replacement Kit


Air baffles are designed to direct airflow through the server to maintain server temperature at a safe
operating level. These baffles must always remain installed during server operation. The Air Baffle
Replacement Kit includes the air baffles needed for one UCS C220 M4 server.

CPU Heat Sink Cleaning Kit


The cleaning kit is used to remove the existing thermal compound from the bottom of the heat sink during
a CPU replacement process. Instructions for cleaning are found at the following link:

http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M4/install/C220M4.html

See the section titled “Replacing CPUs and Heatsinks.”

NOTE: When you purchase a spare CPU, the CPU cleaning kit is included.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 101
SUPPLEMENTAL MATERIAL

RACKS
The Cisco R42612 rack (see Figure 18 on page 103) is certified for Cisco UCS installation at customer sites
and is suitable for the following equipment:

 Cisco UCS B-Series servers and fabric interconnects


 Cisco UCS C-Series and select Nexus switches

The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are
listed in Table 52.

Table 52 R42612 Specifications

Standard  Expansion 
Cisco R42612 Rack
(Static with side panels) (Static without Side Panels)

Dimensions  79.25 x 23.50 x 49.84 in. 79.25 x 23.50 x 49.84 in.


(H x W x D) (2013 x 597 x 1266 mm) (2013 x 597 x 1266 mm)

Dimensions  84.25 x 32 x 54.84 in. 84.25 x 32 x 54.84 in.(


(H x W x D) (2140 x 813 x 1393 mm) 2140 x 813 x 1393 mm)
with packaging

Distance from front 29.19 in. (741.5 mm) 29.19 in. (741.5 mm)
mounting rail to rear
mounting rail

Weight 339.51 lb (154 kg) 264.55 lb (120 kg)

Weight with 410.06 lb (186 kg) 335.10 lb (152 kg)


packaging

Side panels included Yes No

Equipment mounting 42 RU 42 RU
capacity

Static load capacity 2700 lb (1224.7 kg) 2700 lb (1224.7 kg)

Dynamic load N/A N/A


capacity

102 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

Figure 18 Cisco R42612 Rack

Front View Rear View

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 103
SUPPLEMENTAL MATERIAL

PDUs
Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection.

Cisco RP Series PDU models distribute power to up to 42 outlets. The architecture organizes power
distribution, simplifies cable management, and enables you to move, add, and change rack equipment
without an electrician.

With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one.
The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT
equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords.

The C-series severs accept the zero-rack-unit (0RU) or horizontal PDU. See Figure 19 for one example of a
zero rack unit PDU.

Figure 19 RP208-30M1P-6-36 PDU

1 = Ground

2 = 20 A circuit breakers

3 = IEC 60320 C13 outlets

4 = EC 60320 C19 outlets

5 = NEMA L6-30P plug

104 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

KVM CABLE
The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for
a monitor, and dual USB 2.0 ports for a keyboard and mouse. With this cable, you can create a direct
connection to the operating system and the BIOS running on the server.

The KVM cable ordering information is listed in Table 53.

Table 53 KVM Cable

Product ID (PID) PID Description

N20-BKVM= KVM cable for server console port

Figure 20 KVM Cable

1 Connector (to server front panel) 3 VGA connector (for a monitor)

2 DB-9 serial connector 4 Two-port USB 2.0 connector (for a mouse and
keyboard)

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 105
SUPPLEMENTAL MATERIAL

Motherboard USB and SD Ports, and RAID Card Backup Locations


The C240 M4 SFF motherboard has a general-purpose USB socket and two SD sockets, as shown in Figure 21.
The mounting locations for RAID card backup are also shown

Figure 21 Motherboard USB and SD Ports and RAID Backup Location

2 3 4 5 6

FAN 06 FAN 05 FAN 04 FAN 03 FAN 02 FAN 01

SD2
SD1
CPU 2
8

1 9
Riser 2

10
CPU 1

Riser 1
11

352948
17 16 15 14 13 12

1 Drives 10 PCIe riser 1 (PCIe slots 1, 2, 3*)


(hot-swappable, accessed through front *Slot 3 not present in all versions.
panel)
2 Fan modules (six, hot-swappable) 11 SuperCap RAID data cache power backup
unit mounting locations (two, on air baffle
not shown in this view)
3 DIMM sockets on motherboard (up to 24 12 SATA boot drives (two sockets available only
DIMMs) on PCIe riser 1 option C)
4 CPUs and heatsinks (two) 13 Socket for embedded RAID interposer board
5 Cisco SD card slots on motherboard (two) 14 Cisco modular RAID controller PCIe slot
(dedicated slot and bracket)
6 USB 3.0 slot on motherboard 15 RTC battery on motherboard
7 Power supplies (hot-swappable, accessed 16 Embedded RAID header for RAID key
through rear panel
8 Trusted platform module (TPM) socket on 17 SuperCap power module (RAID backup)
motherboard, under PCIe riser 2 mounting location on air baffle (not shown)
9 PCIe riser 2 (PCIe slots 4, 5, 6)

106 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

NEBS Compliance
When configured with choices from the specific set of components shown in Table 54, the UCS C240 M4 M4
server meets Network Equipment Building Standards (NEBS) Level 1 and Level 3 compliance. For specific
configuration rules, see the applicable sections of this document.

Table 54 C240 M4 M4 NEBS Compliant Components

Component
Description Product ID (PID)
Category

C240 M4 NEBS UCS C240M4 NEBS SFF 16 HDD, no expander, CPU, memory, UCSC-C240-M4SNEBS
HDD, PCIe cards, power supply, or rail kit

CPUs (up to two) 2.20 GHz E5-2699 v4/145W 22C/55MB Cache/DDR4 2400MHz UCS-CPU-E52699E

2.20 GHz E5-2658 v3/105W 12C/30MB Cache/DDR4 2133MHz UCS-CPU-E52658D

DIMMs (up to 24) 32GB DDR4-2400-MHz RDIMM/PC4-19200/dual rank/x4/1.2v UCS-MR-1X322RV-A

16GB DDR4-2400-MHz RDIMM/PC4-19200/single rank/x4/1.2v UCS-MR-1X161RV-A

8GB DDR4-2400-MHz RDIMM/PC4-19200/single rank/x4/1.2v UCS-MR-1X081RV-A

Internal RAID Cisco 12G SAS Modular RAID Controller UCSC-MRAID12G


Controller

Internal RAID Cisco 12Gbps SAS 1 GB FBWC Cache module (RAID 0/1/5/6) UCSC-MRAID12G-1GB
Controller Cache
Module (up to 1) Cisco 12Gbps SAS 2 GB FBWC Cache module (RAID 0/1/5/6) UCSC-MRAID12G-2GB

Cisco 12Gbps SAS 4 GB FBWC Cache module (RAID 0/1/5/6) UCSC-MRAID12G-4GB

External RAID Cisco 12G SAS HBA with 8 external ports UCSC-SAS9300-8E
Controller 
(up to one)

HDDs (up to 16) 1.2 TB 12G SAS 10K RPM SFF HDD UCS-HD12TB10K12G

1.8 TB 12G SAS 10K RPM SFF HDD (4K) UCS-HD18TB10KS4K

900GB 12G SAS 10K RPM SFF HDD UCS-HD900G10K12G

SSDs (up to 16) 1.6TB 2.5 inch Ent. Performance 12G SAS SSD(10X endurance) UCS-SD16TB12S4-EP

400GB 2.5 inch Ent Performance 12G SAS SSD (10X endurance) UCS-SD400G12S4-EP

960GB 2.5 inch Enterprise Value 6G SATA SSD UCS-SD960GBKS4-EV

SD and USB 64GB SD Card for UCS Servers UCS-SD-64G-S

32GB SD Card for UCS servers UCS-SD-32G-S

PCIe mLOM Cisco UCS VIC1227T VIC MLOM - Dual Port 10GBaseT UCSC-MLOM-C10T-02
Cards
Cisco UCS VIC1227 VIC MLOM - Dual Port 10Gb SFP+ UCSC-MLOM-CSC-02

Intel i350 MLOM NIC UCSC-MLOM-IRJ45

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 107
SUPPLEMENTAL MATERIAL

Table 54 C240 M4 M4 NEBS Compliant Components

Component
Description Product ID (PID)
Category

PCIe Cards Cisco VIC 1225 Dual Port 10Gb SFP+ CAN UCSC-PCIE-CSC-02

Cisco VIC 1225T Dual Port 10GBaseT CNA UCSC-PCIE-C10T-02

Intel i350 Quad Port 1Gb Adapter UCSC-PCIE-IRJ45

Intel X540 Dual Port 10GBase-T Adapter UCSC-PCIE-ITG

Intel X520 Dual Port 10Gb SFP+ Adapter N2XX-AIPCI01

Qlogic QLE8362 dual-port 10 GbE FCoE CNA UCSC-PCIE-Q8362

Emulex OCe14102-FX dual-port 10 GbE FCoE CNA UCSC-PCIE-E14102

Emulex OCe14102B-UX dual-port 10G SFP+ with iSCSI, FCoE UCSC-PCIE-E14102B


CNA

Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics UCSC-PCIE-E16002

Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA N2XX-AQPCI05

Power Supply 1200W V2 AC Power Supply for 2U C-Series Servers UCSC-PSU2V2-1200W

930W DC Power Supply for 2U Servers UCSC-PSU-930WDC

930W V2 DC Power Supply for 2U C-Series Servers UCSC-PSU2V2-930DC

Power Cables C-Series -48VDC PSU Power Cord, 3.5M, 3 Wire, 8AWG, 40A CAB-48DC-40A-8AWG

Power Cord - 250V, 10A - Brazil CAB-250V-10A-BR

AC Power Cord - 250V, 10A - PRC CAB-250V-10A-CN

AC Power Cord - 250V, 10A - Argentina CAB-250V-10A-AR

AC Power Cord - 250V, 10A , India CAB-250V-10A-ID

AC Power Cord - 250V, 10A - Israel CAB-250V-10A-IS

N5000 AC Power Cable, 10A, 250V, Australia, 2.5m CAB-9K10A-AU

N5000 AC Power Cable, 10A, 250V, Europe, 2.5m CAB-9K10A-EU

N5000 AC Power Cable, 10A, 250V, Italy, 2.5m CAB-9K10A-IT

N5000 AC Power Cable, 10A, 250V, Switzerland, 2.5m CAB-9K10A-SW

N5000 AC Power Cable, 10A, 250V, United Kingdom, 2.5m CAB-9K10A-UK

N5000 Power Cord, 125VAC 15A NEMA 5-15 Plug, North CAB-9K12A-NA
America, 2.5m

AC Power Cord, NEMA L6-20 - C13, 2M/6.5ft CAB-AC-L620-C13

CABASY,WIRE,JUMPER CORD,PWR,2 Meter,C13/C14,10A/250V CAB-C13-C14-2M

108 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

Table 54 C240 M4 M4 NEBS Compliant Components

Component
Description Product ID (PID)
Category

Power Cord C13-C14, 2M/6.5ft Japan PSE mark CAB-C13-C14-2M-JP

Power cord, C13 to C14 (recessed receptacle), 10A CAB-C13-C14-AC

Cabinet Jumper Power Cord, 250 VAC 10A, C14-C13 CAB-C13-CBN


Connectors

Japan, 90-125VAC 12A NEMA 5-15 Plug, 2.4m CAB-JPN-3PIN

N5000 AC Power Cable, 6A, 250V, North America, 2.5m CAB-N5K6A-NA

No power cord option R2XX-DMYMPWRCORD

Rail Kit Ball Bearing Rail Kit for C220 M4 and C240 M4 Rack Servers UCSC-RAILB-M4

KVM Cable KVM local IO cable for UCS servers console port N20-BKVM

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 109
END OF SALE (EOS) COMPONENTS

END OF SALE (EOS) COMPONENTS


Table 55 lists the PIDS that are no longer orderable but still supported. A platform with a supported PID is
still recognized by the Cisco Technical Assistance Center (TAC) as a valid configuration.

Table 55 EOS Components

PID Description

GPUs
UCSC-GPU-VGXK2 NVIDIA GRID K2

110 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS
Dimensions and Weight

Table 56 UCS C240 M4 Dimensions and Weight

Parameter Value

Height 3.43 in. (8.70 cm)

Width (including slam latches) 17.65 in.(44.8 cm)


Including handles:
18.96 in (48.2 cm)

Depth 29.0 in. (73.8 cm)


Including handles:
30.18 in (76.6 cm)

Front Clearance 3 in. (76 mm)

Side Clearance 1 in. (25 mm)

Rear Clearance 6 in. (152 mm)

Weight1

Maximum
(24 HDD model with 24 HDDs, 2 CPUs, 24 DIMMs, 2 1200 W power supplies) 62.7 lbs (28.4 kg)
(16 HDD model with 16 HDDs, 2 CPUs, 24 DIMMs, 2 1200 W power supplies) 58.9 lbs (27.7 kg)
(8 HDD model with 8 HDDs, 2 CPUs, 24 DIMMs, 2 1200 W power supplies) 52.9 lbs (24.0 kg)

Minimum
(24 HDD model with 1 HDD, 1 CPU, 1 DIMM, 1 1200 W power supply) 40.1 lbs (18.2 kg)
(16 HDD model with 1 HDD, 1 CPU, 1 DIMM, 1 1200 W power supply) 40.7 lbs (18.5 kg)
(8 HDD model with 1 HDD, 1 CPU, 1 DIMM, 1 1200 W power supply) 39.2 lbs (17.8 kg)

Bare
(24 HDD model with 0 HDD, 0 CPU, 0 DIMM, 1 1200 W power supply) 37.9 lbs (17.2 kg)
(16 HDD model with 0 HDD, 0 CPU, 0 DIMM, 1 1200 W power supply) 38.5 lbs (17.5 kg)
(8 HDD model with 0 HDD, 0 CPU, 0 DIMM, 1 1200 W power supply) 37.0 lbs (16.8 kg)

Notes . . .
1. Weight includes inner rail, which is attached to the server. Weight does not include outer rail, which is attached
to the rack.

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 111
TECHNICAL SPECIFICATIONS

Power Specifications
The server is available with the following types of power supplies:

 650 W (AC)
 930 W (DC)
 1200 W (AC)
 1400 W (AC)

The general power specifications for the C240 M4 SFF server are listed as follows:

 650 W (AC) power supply (see Table 57).


 930 W (DC) power supply (see Table 58).
 930 W V2 (DC) power supply (see Table 59)
 1200 W V2 (AC) power supply (see Table 60 on page 114)
 1400 W V2 (AC) power supply (see Table 61 on page 115)

Table 57 UCS C240 M4 SFF Power Specifications (650 W AC power supply)

Description Specification

AC input voltage range Voltage Range 100-127 VAC, 200-240 VAC nominal 
(range: 90-140 VAC, 180-264 VAC)

AC input frequency 50 to 60 Hz nominal (range: 47 to 63 Hz)

Maximum AC input current 7.6 Amps maximum at 100 VAC


3.65 Amps maximum at 208 VAC

Maximum Input VA 760 VA at 100 VAC

Maximum output power for each 650 W


power supply

Maximum AC inrush current 35 A (sub cycle duration)

Maximum hold up time 12 ms @ 650 W

Power supply output voltage 12 VDC

Power supply standby voltage 12 VDC

Power supply efficiency Climate Savers Platinum Efficiency (80Plus Platinum Certified)

Form factor RSP1

Input connector IEC320 C14

112 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS

Table 58 UCS C240 M4 SFF Power Specifications (930 W DC power supply)

Description Specification

AC input voltage Voltage Range: -48 to -60 VDC nominal


(range: -40 to -60 VDC)

Max DC Input current 23A at -48 VDC

Maximum Input Power 1104 W at -48VDC

Maximum output power per power 930W


supply

Maximum inrush current 35 A (sub cycle duration)

Maximum hold up time 4ms @ 930 W

Power supply output voltage 12 VDC

Power supply standby voltage 12 VDC

Efficiency rating > 92% at 50% Load

Form Factor RSP1

Input connector 3-pos euro terminal block spring cage connection connector. Plug
PID UCSC-CONN-930WDC=

Table 59 UCS C240 M4 SFF Power Specifications (930 W DC V2 power supply)

Description Specification

AC input voltage Voltage Range: -48 to -60 VDC nominal 


(range: -40 to -60 VDC)

Max DC Input current 23 A at -48 VDC

Maximum Input Power 1104 W at -48 VDC

Maximum output power per power 930 W


supply

Maximum inrush current 35 A (sub cycle duration)

Maximum hold up time 4 ms @ 930 W

Power supply output voltage 12 VDC

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 113
TECHNICAL SPECIFICATIONS

Table 59 UCS C240 M4 SFF Power Specifications (930 W DC V2 power supply) (continued)

Description Specification

Power supply standby voltage 12 VDC

Efficiency rating > 92% at 50% Load

Form Factor RSP1

Input connector 3 wire Connector (Molex MINIFIT SR. R/A )

Table 60 UCS C240 M4 SFF Power Specifications (1200 W V2 AC power supply)

Description Specification

AC input voltage Voltage Range 100-127 VAC, 200-240 VAC nominal 


(range: 90-140 VAC, 180-264 VAC)

AC input frequency 50 to 60 Hz nominal 


(range: 47 to 63 Hz)

Max AC Input current 11 A at 100 VAC


7 A at 200 VAC

Maximum Input VA 1400 V\A @230VAC

Maximum output power per power 800 W at 100 - 120 VAC


supply 1200 W at 200 - 240 VAC
36 W on 12V DC Standby

Maximum inrush current 30 A (sub cycle duration)

Maximum hold up time 12 ms @ 1200 W

Power supply output voltage 12 VDC

Power supply standby voltage 12 VDC

Efficiency rating Climate Savers Platinum Efficiency (80Plus Platinum Certified)

Form Factor RSP1 (C-Series 2U and 4U Server)

Input connector IEC320 C14

114 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS

Table 61 UCS C240 M4 SFF Power Specifications (1400 W V2 AC power supply)

Description Specification

AC input voltage Voltage Range 200-240 VAC nominal 


(range:180-264 VAC)

AC input frequency 50 to 60 Hz nominal 


(range: 47 to 63 Hz)

Max AC Input current 8.5 A at 200 VAC

Maximum Input VA 1630 VA @230 VAC

Maximum output power per power 1400 W at 200-240 VAC


supply 36 W on 12V DC Standby

Maximum inrush current 30 A (sub cycle duration)

Maximum hold up time 12 ms @ 1400 W

Power supply output voltage 12 VDC

Power supply standby voltage 12 VDC

Efficiency rating Climate Savers Platinum Efficiency (80Plus Platinum Certified)

Form Factor RSP1 (C-Series 2U and 4U Server)

Input connector IEC320 C14

For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:

http://ucspowercalc.cisco.com

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 115
TECHNICAL SPECIFICATIONS

Environmental Specifications
The power specifications for the C240 M4 server are listed in Table 62.

Table 62 UCS C240 M4 SFF Environmental Specifications

Parameter Minimum

Temperature operating 41 to 95° F (5 to 35° C)


derate the maximum temperature by 1°C per every 
1000 ft. (305 m) of altitude above sea level

Temperature nonoperating –40 to 149°F (–40 to 65° C)

Humidity (RH) operating 10 to 90%, non-condensing at 82° F (28° C)

Humidity (RH) nonoperating 5 to 93% at 82° F (28° C)

Altitude operating 0 to 3,000 m (0 to 10,000 ft.)

Altitude nonoperating 0 to 12,192 m (0 to 40,000 ft.)

Sound Power level, Measure 5.8


A-weighted per ISO7779 LWAd (Bels)
Operation at 73°F (23°C)

Sound Pressure level, Measure 43


A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)

116 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS

Compliance Requirements
The regulatory compliance requirements for C-Series servers are listed in Table 63.

Table 63 UCS C-Series Regulatory Compliance Requirements

Parameter Description

Regulatory Compliance Products should comply with CE Markings per directives


2004/108/EC and 2006/95/EC

Safety UL 60950-1 Second Edition


CAN/CSA-C22.2 No. 60950-1 Second Edition
EN 60950-1 Second Edition
IEC 60950-1 Second Edition
AS/NZS 60950-1
GB4943 2001

EMC - Emissions 47CFR Part 15 (CFR 47) Class A 


AS/NZS CISPR22 Class A 
CISPR22 Class A
EN55022 Class A 
ICES003 Class A 
VCCI Class A 
EN61000-3-2
EN61000-3-3
KN22 Class A 
CNS13438 Class A

EMC - Immunity EN55024


CISPR24
EN300386
KN24

117 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
Discontinued EOL Products

Discontinued EOL Products


Below is the list of parts were previously available for this product and are no longer sold. Please refer to
the EOL Bulletin Links via the Table 64 below to determine if still supported.

Table 64 EOL Products

EOS option PID Description EOL bulletin link


MEMORY
UCS-ML-1X324RU-A 32GB DDR4-2133-MHz http://www.cisco.com/c/en/us/products/collater
LRDIMM/PC4-17000/quad rank/x4/1.2v al/servers-unified-computing/ucs-b-series-blade-s
ervers/eos-eol-notice-c51-739140.html
UCS-ML-1X324RV-A 32GB DDR4-2400-MHz https://www.cisco.com/c/en/us/products/collate
LRDIMM/PC4-19200/quad rank/x4/1.2v ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-ML-1X644RV-A 64GB DDR4-2400-MHz https://www.cisco.com/c/en/us/products/collate
LRDIMM/PC4-19200/quad rank/x4/1.2v ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-MR-1X081RU-A 8GB DDR4-2133-MHz http://www.cisco.com/c/en/us/products/collater
RDIMM/PC4-17000/single rank/x4/1.2v al/servers-unified-computing/ucs-b-series-blade-s
ervers/eos-eol-notice-c51-739140.html
UCS-MR-1X081RU-A 8GB DDR4-2133-MHz http://www.cisco.com/c/en/us/products/collater
RDIMM/PC4-17000/single rank/x4/1.2v al/servers-unified-computing/ucs-b-series-blade-s
ervers/eos-eol-notice-c51-739140.html
UCS-MR-1X081RV-A 8GB DDR4-2400-MHz https://www.cisco.com/c/en/us/products/collate
RDIMM/PC4-19200/single rank/x4/1.2v ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-MR-1X161RV-A 16GB DDR4-2400-MHz https://www.cisco.com/c/en/us/products/collate
RDIMM/PC4-19200/single rank/x4/1.2v ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-MR-1X162RU-A 16GB DDR4-2133-MHz http://www.cisco.com/c/en/us/products/collater
RDIMM/PC4-17000/dual rank/x4/1.2v al/servers-unified-computing/ucs-b-series-blade-s
ervers/eos-eol-notice-c51-739140.html
UCS-MR-1X162RU-A 16GB DDR4-2133-MHz http://www.cisco.com/c/en/us/products/collater
RDIMM/PC4-17000/dual rank/x4/1.2v al/servers-unified-computing/ucs-b-series-blade-s
ervers/eos-eol-notice-c51-739140.html
UCS-MR-1X162RV-A 16GB DDR4-2400-MHz https://www.cisco.com/c/en/us/products/collate
RDIMM/PC4-19200/dual rank/x4/1.2v ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-MR-1X322RU-A 32GB DDR4-2133-MHz http://www.cisco.com/c/en/us/products/collater
RDIMM/PC4-17000/dual rank/x4/1.2v al/servers-unified-computing/ucs-b-series-blade-s
ervers/eos-eol-notice-c51-739140.html
UCS-MR-1X322RVA-S 32GB DDR4-2400-MHz https://www.cisco.com/c/en/us/products/collate
RDIMM/PC4-19200/dual rank/x4/1.2v ral/servers-unified-computing/ucs-c-series-rack-se
Samsung rvers/eos-eol-notice-c51-741234.html
UCS-MR-1X648RU-A 64GB DDR4-2133-MHz https://www.cisco.com/c/en/us/products/collate
TSV-RDIMM/PC4-17000/octal ral/servers-unified-computing/ucs-c-series-rack-se
rank/x4/1.2v rvers/eos-eol-notice-c51-741234.html
DRIVES

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 118
Discontinued EOL Products

Table 64 EOL Products

EOS option PID Description EOL bulletin link


HDD
A03-D300GA2 ^300GB 6Gb SAS 10K RPM SFF HDD/hot http://www.cisco.com/c/en/us/products/collater
plug/drive sled mounted al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-737249.html
A03-D600GA2 ^600GB 6Gb SAS 10K RPM SFF HDD/hot http://www.cisco.com/c/en/us/products/collater
plug/drive sled mounted al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-737249.html
UCS-HD12T10KS2-E 1.2 TB 6G SAS 10K rpm SFF HDD https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-735827.html
A03-D1TBSATA ^1TB 6Gb SATA 7.2K RPM SFF HDD/hot http://www.cisco.com/c/en/us/products/collater
plug/drive sled mounted al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-737249.html
UCS-HD1T7K12G 1 TB 12G SAS 7.2K RPM SFF HDD https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-HD1T7K6GA 1 TB 6G SATA 7.2K RPM SFF HDD https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-HD1T7KS2-E ^1TB SAS 7.2K RPM 2.5 inch HDD/hot http://www.cisco.com/c/en/us/products/collater
plug/drive sled mounted al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-737249.html
UCS-HD2T7K12G 2 TB 12G SAS 7.2K RPM SFF HDD https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-HD300G10K9 300GB 12G SAS 10K RPM SFF HDD (SED) https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-740779.html
UCS-HD450G15K12G 450GB 12G SAS 15K RPM SFF HDD https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-740779.html
UCS-HD450G15KS2-E 450GB SAS 15K RPM SFF HDD http://www.cisco.com/c/en/us/products/collater
al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-736502.html
UCS-HD600G10KS4K 600GB 12G SAS 10K RPM SFF HDD (4K) https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-740779.html
UCS-HD600G15KS2-E 600GB SAS 15K RPM SFF HDD http://www.cisco.com/c/en/us/products/collater
al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-736502.html
UCS-HD900G10K12G 900GB 12G SAS 10K RPM SFF HDD https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-740779.html
UCS-HDD300GI2F105 300GB 6Gb SAS 15K RPM SFF HDD/hot http://www.cisco.com/c/en/us/products/collater
plug/drive sled mounted al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-736502.html

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 119
Discontinued EOL Products

Table 64 EOL Products

EOS option PID Description EOL bulletin link


UCS-HDD900GI2F106 ^900GB 6Gb SAS 10K RPM SFF HDD/hot http://www.cisco.com/c/en/us/products/collater
plug/drive sled mounted al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-737249.html
Enterprise Performance
UCS-SD16T12S2-EP 1.6TB2.5 inch Enterprise Performance http://www.cisco.com/c/en/us/products/collater
12G SAS SSD al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-736502.html
UCS-SD16TB12S3-EP 1.6TB 2.5 inch Ent. Performance 6GSATA https://www.cisco.com/c/en/us/products/collate
SSD(3X endurance) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-739513.html
UCS-SD16TBEK9 1.6TB Enterprise performance SAS SSD https://www.cisco.com/c/en/us/products/collate
(10XFWPD, SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-740779.html
UCS-SD16TBHK9 ^1.6TB Enterprise performance SAS SSD https://www.cisco.com/c/en/us/products/collate
(10X FWPD, SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-SD200G0KS2-EP 200GB 2.5 inch Enterprise Performance https://www.cisco.com/c/en/us/products/collate
SAS SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-735827.html
UCS-SD200G12S3-EP 200GB 2.5 inch Enterprise performance https://www.cisco.com/c/en/us/products/collate
6G SATA SSD(3 FWPD) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-739513.html
UCS-SD600GBE3K9 600GB Enterprise performance SSD (3X) https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-SD800G0KS2-EP 800GB 2.5 inch Enterprise Performance https://www.cisco.com/c/en/us/products/collate
SAS SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-735827.html
UCS-SD800G12S3-EP 800GB 2.5 inch Enterprise performance https://www.cisco.com/c/en/us/products/collate
6G SATA SSD(3 FWPD) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-739513.html
UCS-SD800GBEK9 800GB Enterprise perforamnce SAS SSD https://www.cisco.com/c/en/us/products/collate
(10X FWPD, SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-740779.html
UCS-SD800GBHK9 ^800GB Enterprise performance SAS SSD https://www.cisco.com/c/en/us/products/collate
(10X FWPD, SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-SD32TSASS3-EP 3.2TB 2.5 inch Enterprise performance https://www.cisco.com/c/en/us/products/collate
12G SAS SSD(3X DWPD) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-SD400G0KS2-EP 400GB 2.5 inch Enterprise Performance https://www.cisco.com/c/en/us/products/collate
SAS SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-735827.html
UCS-SD400G12S2-EP 400GB 2.5 inch Enterprise performance http://www.cisco.com/c/en/us/products/collater
12G SAS SSD al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-736502.html

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 120
Discontinued EOL Products

Table 64 EOL Products

EOS option PID Description EOL bulletin link


UCS-SD400GBEK9 400GB Enterprise performance SAS SSD https://www.cisco.com/c/en/us/products/collate
(10X FWPD, SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-740779.html
UCS-SD400GBHK9 ^400GB Enterprise performance SAS SSD https://www.cisco.com/c/en/us/products/collate
(10X FWPD, SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-SD400GSAS3-EP 400GB 2.5 inch Enterprise performance https://www.cisco.com/c/en/us/products/collate
12G SAS SSD(3X DWPD) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-SD480G12S3-EP 480GB 2.5 inch Ent. Performance https://www.cisco.com/c/en/us/products/collate
6GSATA SSD(3X endurance) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-739513.html
Enterprise Value
UCS-SD120G0KS2-EV 120 GB 2.5 inch Enterprise Value 6G http://www.cisco.com/c/en/us/products/collater
SATA SSD al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-736502.html
UCS-SD120GBE1K9 120GB Enterprise Value SATA SSD (1X https://www.cisco.com/c/en/us/products/collate
DWPD) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-SD120GBKS4-EV 120 GB 2.5 inch Enterprise Value 6G https://www.cisco.com/c/en/us/products/collate
SATA SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-740779.html
UCS-SD150GBKS4-EV 150 GB 2.5 inch Enterprise Value 6G https://www.cisco.com/c/en/us/products/collate
SATA SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-740779.html
UCS-SD16TBKS4-EV 1.6TB 2.5 inch Enterprise Value 6G SATA https://www.cisco.com/c/en/us/products/collate
SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-740779.html
UCS-SD240G0KS2-EV 240GB 2.5 inch Enterprise Value 6G SATA http://www.cisco.com/c/en/us/products/collater
SSD al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-736502.html
UCS-SD240GBKS4-EV 240GB 2.5 inch Enterprise Value 6G SATA https://www.cisco.com/c/en/us/products/collate
SSD ral/servers-unified-computing/ucs-b-series-blade-s
ervers/eos-eol-notice-c51-742066.html
UCS-SD240GBM1K9 240GB Enterprise Value SSD (SATA) (1X https://www.cisco.com/c/en/us/products/collate
FWPD, SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-SD38TBM1K9 3.8TB Enterprise Value SSD (SATA) (1X https://www.cisco.com/c/en/us/products/collate
FWPD, SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-SD480G0KS2-EV 480 GB 2.5 inch Enterprise Value 6G http://www.cisco.com/c/en/us/products/collater
SATA SSD al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-736502.html
UCS-SD480GBE1K9 480GB Enterprise Value SSD (SATA) https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html

121 Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
Discontinued EOL Products

Table 64 EOL Products

EOS option PID Description EOL bulletin link


UCS-SD480GBKS4-EV 480 GB 2.5 inch Enterprise Value 6G https://www.cisco.com/c/en/us/products/collate
SATA SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-740779.html
UCS-SD960G0KS2-EV 960 GB 2.5 inch Enterprise Value 6G http://www.cisco.com/c/en/us/products/collater
SATA SSD al/servers-unified-computing/ucs-c-series-rack-ser
vers/eos-eol-notice-c51-736502.html
UCS-SD960GBE1K9 960GB Enterprise value SSD (SATA) https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-SD960GBM1K9 960GB Enterprise Value SSD (SATA) (1X https://www.cisco.com/c/en/us/products/collate
FWPD, SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCS-SD960GIKS4-EV 960GB 2.5 inch Enterprise Value 6G https://www.cisco.com/c/en/us/products/collate
SATA SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-740779.html
NVMe
UCS-SDHPCIE16TB 1.6TB 2.5 in NVMe based PCIeSSD https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-739513.html
UCS-SDHPCIE800GB 800GB 2.5 in NVMe based PCIeSSD https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-739513.html
UCSC-F-H19001 UCS Rack PCIe/NVMe Storage 1900GB https://www.cisco.com/c/en/us/products/collate
HGST SN150 Read Intensive ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-739513.html
UCSC-F-H38001 UCS Rack PCIe/NVMe Storage 3800GB https://www.cisco.com/c/en/us/products/collate
HGST SN150 Read Intensive ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-739513.html
UCSC-NVMEM4-H1600 Cisco 2.5in U.2 1.6TB HGST SN200 https://www.cisco.com/c/en/us/products/collate
NVMe. High Endurance SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html
UCSC-NVMEM4-H800 Cisco 2.5in U.2 800GB HGST SN200 https://www.cisco.com/c/en/us/products/collate
NVMe. High Endurance SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/eos-eol-notice-c51-741234.html

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) 122

You might also like