You are on page 1of 10

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 10

STREETLIGHT PHOTOMETRIC TEST REPORT

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

DATA OF LAMP PHOTOMETRIC DATA


MODEL 60W-Pilot Imax(cd/klm) 432.5  street_up(%) 0.5
NOMINAL POWER(W) 60 LOR(%) 87.2  street_down(%) 50.2
RATED VOLTAGE(V) TOTAL FLUX(lm/klm) 871.9  house_up(%) 0.3
NOMINAL FLUX(lm) 7806.01 MAXIMUM @(C, ) 45,48.0  house_down(%) 36.3
LAMPS INSIDE 1  up(%) 0.7 76 FLASHAREA(m2)
TEST VOLTAGE(V)  down(%) 86.5 SLI

INTENSITY DISTRIBUTION DIAGRAM MAX INTENSITY CONE SURFACE


IN C PLANS DISTRIBUTION DIAGRAM

C180 HOUSE SIDE


-/+180
C210 C150
-150 150

-120 120 C240 C120

-90 0 90 C270 0 C90


70
90
140
180
-60 210 60
UNIT:cd/klm C300 270 C60
280 C0/180,140.0
C90/270,76.0 360
-30 350 30
0 C330 450 C30
AVERAGE BEAM ANGLE(50%):108.0 DEG
C0
Max @  = 48.0DEG STREET SIDE

C Range: 0 - 360DEG  Range: 0 - 180DEG


C Interval: 45.0DEG  Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.362
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:10.864m [K=1.0000]
Test Date:2023-09-26 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 2 Of 10

STREETLIGHT ISOCANDELA DIAGRAM

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

180 170
160
Classification:
150

140
IES:Type II - Very Short
CIE:Narrow - Short
130 IES:Cut-off
CIE:Full cut-off
Max.At80:28.20cd/klm
120
Max.At90:1.577cd/klm
Max.80-90:28.20cd/klm
110
ISOCANDELA DIAGRAM
100 UNIT cd/klm

Imax=100% 432
270 285 300 315 330 345 C0 15 30 45 60 75 90
90 90% 389

80% 346
80 70% 303

60% 259
70
50% 216

60 40% 173

30% 130
50
20% 86
40
10% 43
30
5% 22
20
 10

C Range: 0 - 360DEG  Range: 0 - 180DEG


C Interval: 45.0DEG  Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.362
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:10.864m [K=1.0000]
Test Date:2023-09-26 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 3 Of 10

COEFFICIENT OF UTILIZATION CURVE


AND ISOLUX DIAGRAM

CU(%) STREETLIGHT COEFFICIENT OF UTILIZATION CURVE


100
TILT ANGLE
0.0(DEG)
90
5.0(DEG)
80 10.0(DEG)
15.0(DEG)
70 20.0(DEG)

60

50

40

30

20

10

0
2 1 0 1 2 3 4
HOUSE SIDE STREET SIDE RATIO OF DISTANCE TO MOUNTING HEIGHT

ROAD SURFACE ISOLUX DIAGRAM


ILLUMINANCE AT MH=10 m,Enadir = 2.21 lx/klm
TO CONVERT TO OTHER MH,MULTIPLY BY FACTOR IN THE TABLE.
HOUSE SIDE

1
HEIGHT FACTOR
5 m 4.000
0
6 m 2.778
7 m 2.041
1
D/MH

8 m 1.563
2 9 m 1.235
STREET SIDE

10 m 1.000
3 11 m 0.826
12 m 0.694
4-7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 13 m 0.592
RATIO OF DISTANCE TO MOUNTING HEIGHT 14 m 0.510
2 1.5 1.3 1 0.76 15 m 0.444
0.25 0.13 0.076 0.025 0.013
16 m 0.391

C Range: 0 - 360DEG  Range: 0 - 180DEG


C Interval: 45.0DEG  Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.362
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:10.864m [K=1.0000]
Test Date:2023-09-26 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 4 Of 10

ZONAL FLUX DIAGRAM

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

 C0 C45 C90 C135 C180 C225 C270 C315   zone  total %lum,lamp

10 222.1 254.2 264.1 251.7 219.7 189.8 178.0 189.3 0- 10 21.05 21.05 2.41,2.1

20 227.6 290.9 295.4 281.7 221.1 164.0 145.3 163.4 10- 20 63.07 84.12 9.65,8.41

30 236.4 336.6 310.6 313.7 226.5 143.1 123.5 138.6 20- 30 104.6 188.7 21.6,18.9

40 239.4 397.5 314.9 359.0 231.6 123.2 107.9 117.8 30- 40 146.3 335.0 38.4,33.5

50 228.4 426.8 283.1 406.2 228.7 102.2 87.71 92.39 40- 50 183.1 518.1 59.4,51.8

60 188.4 263.1 160.7 355.4 211.7 73.93 57.95 60.05 50- 60 186.2 704.3 80.8,70.4

70 67.35 70.54 38.25 142.7 149.9 38.75 17.11 25.38 60- 70 117.2 821.5 94.2,82.1

80 7.520 9.033 6.943 28.20 27.16 13.50 7.913 4.293 70- 80 37.81 859.3 98.6,85.9

90 0.3742 0.1797 0.1667 1.539 1.577 0.5466 0.1622 0.3001 80- 90 5.272 864.6 99.2,86.5

100 0.7548 0.3344 0.2174 0.2437 0.4439 0.5165 0.4083 0.7869 90-100 0.3936 865.0 99.2,86.5

110 1.169 0.5537 0.3733 0.4148 0.8712 1.154 0.9395 1.418 100-110 0.6946 865.7 99.3,86.6

120 1.522 0.7908 0.5542 0.6300 1.270 1.731 1.527 1.861 110-120 1.047 866.7 99.4,86.7

130 1.761 1.021 0.7359 0.8365 1.595 2.045 1.987 2.100 120-130 1.236 867.9 99.5,86.8

140 1.858 1.228 0.9192 1.025 1.852 2.201 2.257 2.222 130-140 1.244 869.2 99.7,86.9

150 1.883 1.440 1.121 1.214 1.962 2.366 2.397 2.266 140-150 1.109 870.3 99.8,87

160 1.913 1.658 1.370 1.423 1.992 2.381 2.368 2.180 150-160 0.8669 871.2 99.9,87.1

170 1.959 1.875 1.660 1.643 2.004 2.237 2.208 2.038 160-170 0.5480 871.7 100,87.2

180 2.004 2.080 1.961 1.867 2.004 2.080 1.963 1.866 170-180 0.1873 871.9 100,87.2

DEG LUMINOUS INTENSITY:cd/klm UNIT:lm/klm

C Range: 0 - 360DEG  Range: 0 - 180DEG


C Interval: 45.0DEG  Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.362
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:10.864m [K=1.0000]
Test Date:2023-09-26 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 5 Of 10

ISOCANDELA DIAGRAM

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

90 10% 43.35
20% 86.71
80 30% 130.1
40% 173.4
70
50% 216.8
60% 260.1
60
70% 303.5
50 80% 346.8
90% 390.2
40

30

20
VERTICAL(DEG)

10

-10

-20

-30

-40

-50

-60

-70
Imax:433.5(H31.5,V-38.0)
-80 (At:C=45.0,Gamma=48.0)
UNIT: cd/klm
-90
-90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90
HORIZONTAL(DEG)

C Range: 0 - 360DEG  Range: 0 - 180DEG


C Interval: 45.0DEG  Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.362
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:10.864m [K=1.0000]
Test Date:2023-09-26 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 6 Of 10

Planar Illuminance Curve

Planar Illuminance Curve


E(lx/1000lm) MH = 10 m
3

C0/180

2.7 C90/270

2.4

2.1

1.8

1.5

1.2

0.9

0.6

0.3

0
-25 -20 -15 -10 -5 0 5 10 15 20 25
Distance(m)

C Range: 0 - 360DEG  Range: 0 - 180DEG


C Interval: 45.0DEG  Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.362
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:10.864m [K=1.0000]
Test Date:2023-09-26 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 7 Of 10

LCS REPORT

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

LUMINAIRE CLASSIFICATION SYSTEM(LCS) GRAPH


Uplight
350(lm)

280

210

140

100 70 100

90 90

80 80

60 60

Back Front
30 30

C Range: 0 - 360DEG  Range: 0 - 180DEG


C Interval: 45.0DEG  Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.362
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:10.864m [K=1.0000]
Test Date:2023-09-26 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 8 Of 10

BUG REPORT

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

IESNA Luminaire Flux Distribution Table:


Zone Lumens Luminaire %
FL - Front-Low(0-30) 118.36 13.6
FM - Front-Medium(30-60) 311.65 35.7
FH - Front-High(60-80) 69.798 8.0
FVH - Front-Very High(80-90) 1.7513 0.2
Total Forward Light 506.17 58.1

BL - Back-Low(0-30) 70.31 8.1


BM - Back-Medium(30-60) 203.95 23.4
BH - Back-High(60-80) 85.233 9.8
BVH - Back-Very High(80-90) 3.5207 0.4
Total Back Light 365.73 41.9

UL - Uplight-Low(90-100) 0.39365 0.0


UH - Uplight-High(100-180) 6.9321 0.8
Total Up Light 7.3258 0.8

BUG(Back,Up,Glare) Rating B0-U1-G0

Zone Downward Upward Total


Lumens Lumens Lumens
House Side 363.01 2.7195 365.73
Street Side 501.56 4.6062 506.17

C Range: 0 - 360DEG  Range: 0 - 180DEG


C Interval: 45.0DEG  Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.362
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:10.864m [K=1.0000]
Test Date:2023-09-26 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 9 Of 10

ROAD ISOCANDELA REPORT

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

ROAD SURFACE ISOCANDELA DIAGRAM

V.Short

1MH

Short

2.25MH

Medium

3.75MH

Long

Type I Type II Type III Type IV


6MH
1MH 1MH 1.75MH 2.75MH
Pavement Road
70% 50% 20% 5% 2.5%

C Range: 0 - 360DEG  Range: 0 - 180DEG


C Interval: 45.0DEG  Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.362
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:10.864m [K=1.0000]
Test Date:2023-09-26 Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 10 Of 10

LUMINOUS DISTRIBUTION INTENSITY DATA

NAME: TYPE: WEIGHT:

SPEC.: DIM.: SERIAL No.:

MFR.: SUR.: Shielding Angle:

Table--1 UNIT: cd/klm


C(DEG)
 (DEG) 0 45 90 135 180 225 270 315
0 220 220 220 220 220 220 220 220
5 220 237 243 236 220 205 198 204
10 222 254 264 252 220 190 178 189
15 225 272 282 267 220 176 161 176
20 228 291 295 282 221 164 145 163
25 232 312 305 296 223 153 133 150
30 236 337 311 314 226 143 124 139
35 240 365 315 335 230 133 116 128
40 239 398 315 359 232 123 108 118
45 236 427 305 385 231 113 97.8 106
50 228 427 283 406 229 102 87.7 92.4
55 216 371 237 404 223 89.1 75.6 77.6
60 188 263 161 355 212 73.9 57.9 60.1
65 138 144 79.8 256 191 56.7 38.3 41.1
70 67.4 70.5 38.3 143 150 38.8 17.1 25.4
75 24.4 30.3 16.0 67.9 79.8 24.6 9.95 14.5
80 7.52 9.03 6.94 28.2 27.2 13.5 7.91 4.29
85 0.93 2.07 2.71 7.90 8.93 3.63 3.77 0.66
90 0.37 0.18 0.17 1.54 1.58 0.55 0.16 0.30
95 0.55 0.25 0.16 0.18 0.28 0.29 0.24 0.50
100 0.75 0.33 0.22 0.24 0.44 0.52 0.41 0.79
105 0.97 0.44 0.29 0.32 0.65 0.82 0.65 1.11
110 1.17 0.55 0.37 0.41 0.87 1.15 0.94 1.42
115 1.36 0.67 0.46 0.52 1.08 1.48 1.24 1.67
120 1.52 0.79 0.55 0.63 1.27 1.73 1.53 1.86
125 1.65 0.91 0.65 0.74 1.44 1.91 1.78 2.00
130 1.76 1.02 0.74 0.84 1.59 2.05 1.99 2.10
135 1.83 1.12 0.83 0.93 1.73 2.14 2.14 2.16
140 1.86 1.23 0.92 1.02 1.85 2.20 2.26 2.22
145 1.87 1.33 1.02 1.12 1.93 2.28 2.34 2.26
150 1.88 1.44 1.12 1.21 1.96 2.37 2.40 2.27
155 1.90 1.54 1.24 1.32 1.98 2.40 2.40 2.23
160 1.91 1.66 1.37 1.42 1.99 2.38 2.37 2.18
165 1.94 1.77 1.51 1.53 2.01 2.32 2.31 2.11
170 1.96 1.88 1.66 1.64 2.00 2.24 2.21 2.04
175 1.98 1.98 1.81 1.76 2.00 2.17 2.09 1.95
180 2.00 2.08 1.96 1.87 2.00 2.08 1.96 1.87

C Range: 0 - 360DEG  Range: 0 - 180DEG


C Interval: 45.0DEG  Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.362
Temperature:25.3DEG Humidity:65.0%
Operators: Test Distance:10.864m [K=1.0000]
Test Date:2023-09-26 Remarks:

You might also like