Professional Documents
Culture Documents
1 s2.0 S0308814623028054 Main
1 s2.0 S0308814623028054 Main
Food Chemistry
journal homepage: www.elsevier.com/locate/foodchem
A R T I C L E I N F O A B S T R A C T
1. Introduction euphoria, blurred vision, mental confusion, and lethargy with around
75 % of the potency of Δ9-THC (La Maida, Di Giorgi, Pichini, Busardò, &
Cannabinoid-infused edibles containing e.g. cannabidiol (CBD) and Huestis, 2022). It is therefore not surprising that Δ8-THC-infused edibles
recently Δ8-tetrahydrocannabinol (Δ8-THC), but lacking Δ9-tetrahy are pursued as a legal substitution of Δ9-THC by consumers (LoParco,
drocannabinol (Δ9-THC), are becoming increasingly popular for thera Rossheim, Walters, Zhou, Olsson, & Sussman, 2023).
peutic or recreational purposes (Leas, Nobles, Shi, & Hendrickson, 2022; Due to the negligible occurrence of natural Δ8-THC in cannabis
Peng & Shahidi, 2021). The U.S. Agriculture Improvement Act of 2018 (Gülck & Møller, 2020), Δ8-THC for consumption is typically produced
(2018 Farm Bill) legalized hemp and hemp-derived products containing by acid-catalyzed intramolecular cyclization of CBD (Duffy et al., 2022).
no more than 0.3 % of Δ9-THC on a dry weight basis (Congress, U.S., Δ8-THC-infused products are often marked as “hemp-derived” or “legal
2018). However, the 2018 Farm Bill does not regulate Δ8-THC, which high” products in different formulations, e.g., vape oils, gummies, and
possesses similar therapeutic and mild psychoactive effects as Δ9-THC chocolates, with attractive packaging and are easy to acquire in stores or
(Casajuana Kögel, López-Pelayo, Balcells-Olivero, Colom, & Gual, online. Some “home-kitchen” protocols for making Δ8-THC edibles from
2018). In 1995, Δ8-THC underwent its initial assessment as an anti CBD are also easily available on websites. However, there is no regula
emetic remedy in a trial involving eight children undergoing chemo tion or monitoring for producing Δ8-THC from CBD, and such acid-
therapy (Abrahamov, Abrahamov, & Mechoulam, 1995). Subsequently, induced intramolecular cyclization is normally versatile with not only
Δ8-THC was found to produce a dose-dependent response leading to Δ8-THC but also Δ9-THC and other cannabinoids formed. Subsequent
* Corresponding authors at: Key Laboratory of Phytochemical R&D of Hunan Province and Key Laboratory of Chemical Biology & Traditional Chinese Medicine
Research of Ministry of Education, Hunan Normal University, No.36, Lushan Road, 410081 Changsha, China (B. Chen); Laboratory of Organic Chemistry, Wage
ningen University, Stippeneng 4, 6708 WE Wageningen, The Netherlands (H. Zuilhof, G.IJ. Salentijn).
E-mail addresses: dr-chenpo@vip.sina.com (B. Chen), Han.Zuilhof@wur.nl (H. Zuilhof), Gert.Salentijn@wur.nl (G.IJ. Salentijn).
https://doi.org/10.1016/j.foodchem.2023.138187
Received 23 April 2023; Received in revised form 7 December 2023; Accepted 7 December 2023
Available online 14 December 2023
0308-8146/© 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
S. Huang et al. Food Chemistry 440 (2024) 138187
infusing into a food matrix would result in concomitant concerns about as well as their occurrence in cannabinoid-infused edibles (Δ8-THC
the safety and legal status of Δ8-THC edibles. We summarized 53 anal gummies). We thus aimed to first evaluate eight common synthetic
ysis reports of commercial Δ8-THC products reported by the US protocols using acid catalysis to convert CBD to Δ8-THC (including
Cannabis Council and the New Leafreport Research in 2021 (Council, U. methods suggested for ‘use at home’). Different chromatographic
S. C., 2021; Leafreport, 2022), and there were several issues concerning methods, that are based on different principles were expected to jointly
Δ8-THC products including (i) unknown ingredients, (ii) no content achieve improved separation and profiling of the cannabinoids from
label or incorrect Δ8-THC content, and (iii) illegal levels of Δ9-THC those mixtures: a) an RP-UHPLC-diode array detector (DAD)/high res
(>0.3 %, Supporting Information (SI), Figure S1). While the latter is olution mass spectrometer (HRMS) method; b) a GC-flame ionization
already worrisome, the presence of unknown compounds from the Δ8- detector (FID)/MS method; c) a silica-Ag(I) HPLC-DAD/MS method. For
THC producing process, without toxicity data, is potentially of even the silica-Ag(I) HPLC-DAD/MS method, we hypothesized that Ag(I) af
greater concern. Moreover, increasing hospitalizations induced by finity combined with the normal-phase separation mechanism could
consuming Δ8-THC edibles and other products further underlines the lead to improved separation of cannabinoids. Apart from that, Ag(I)
need to analyze the compositions after converting CBD to Δ8-THC adduct formation and unique MS/MS transitions were expected due to
(LoParco et al., 2023). selective affinities of Ag(I) towards olefins with different numbers and
Cannabinoids in edibles that should at least be analyzed are Δ9-THC, positions of C––C double bonds (Huang et al., 2021; Kaneti, de Smet,
tetrahydrocannabinolic acid (THCA), CBD, cannabidiolic acid (CBDA), Boom, Zuilhof, & Sudhölter, 2002; van Beek & Subrtova, 1995). If so,
and cannabinol (CBN) (AOAC, 2017; AOAC, 2022). Recent research characteristic fragments in the presence of Ag(I) could be used for more
expanded the analytical scope with Δ8-THC (Christinat, Savoy, & Mot reliable identification of isomeric cannabinoids.
tier, 2020; Pisciottano, Guadagnuolo, Soprano, Esposito, & Gallo, 2021;
Song, Meyer, Adejumo, Jovanovich, LeBlanc, & Provis, 2023). As 2. Materials and methods
mentioned earlier, most Δ8-THC found in the market is synthesized and
thus unavoidably accompanied by other THC isomers (Golombek, 2.1. Chemicals and reagents
Müller, Barthlott, Sproll, & Lachenmeier, 2020; Helander, Johansson,
Andersson, & Villén, 2022). Advanced analytical methods to analyze Δ8- Formic Acid (HPLC grade) and silver nitrate (Analytical grade) were
THC, Δ9-THC, and CBD in the presence of synthetic isomers have purchased from Fisher Scientific (Loughborough, Leicestershire, UK).
recently been published. These include a 2D high pressure liquid chro Acetonitrile (ACN, HPLC grade) and methanol (MeOH, HPLC grade)
matography (HPLC) system (C6 Phenyl column as the first dimension were obtained from VWR Chemicals (Gliwice, Poland). n-hexane (hex
and C18 as the second dimension) for analysis of Δ8-THC, Δ9-THC, CBD, ane, HPLC grade) was obtained from Honeywell Riedel-de Haën (Seelze,
Δ6a,10a-THC, and Δ10-THC in e-cigarettes (Chan-Hosokawa, Nguyen, Germany). Ethanol (EtOH, HPLC-grade) was purchased from Biosolve
Lattanzio, & Adams, 2022), and poroshell C18 column with complex Chimie SARL (57260 Dieuze, France). Methyl tert-butyl ether (MTBE)
multi-step gradient conditions for analysis of Δ8-THC, Δ9-THC, Δ6a,10a- was bought from Biosolve BV (Valkenswaard, the Netherlands). Deion
THC, Δ10-THC, and Δ9,11-THC (Reber, Karschner, Seither, Knittel, ized water was obtained from a Milli-QTM direct ultrapure water system
Dozier, & Walterscheid, 2022). All these methods rely on reversed-phase ((18.2 MΩ⋅cm, Milli-Q Integral 3 system, Millipore, USA). Δ9-THC
separations and multiple reaction monitoring (MRM) mass spectrometry standard was purified from cannabis flowers. Crystalline CBD was pur
(MS), with the same MS/MS transitions for different isomers. As a chased from CBDolie.nl. Δ8-THC and Δ8-isoTHC standards were isolated
consequence, multiple challenges remain to be addressed. First, due to from acid-treated CBD (Citti et al., 2019). The group of Prof. Passarella
their near-identical retention times, baseline separation between Δ8- (Marzullo et al., 2020) kindly provided Δ8-iso-THC (for comparison with
THC and Δ9-THC is only achieved by resorting to highly efficient HPLC our isolated standard Δ8-iso-THC) and Δ(4)8-iso-THC. According to NMR
systems such as ultra-high-pressure liquid chromatography (UHPLC), or and peak integrations at DAD 215 nm (SI, Figure S2-S3), the purity of
to the use of core–shell particles. Even then, isomers, e.g., Δ9,11-THC that these five standards was > 98 %. Normal gummies without cannabi
are coeluting with Δ9-THC, interfere with their analysis (Reber, noids were purchased from a local supermarket in Wageningen, the
Karschner, Seither, Knittel, Dozier, & Walterscheid, 2022). Second, the Netherlands, and labeled as N#1, N#2, and N#3. Δ8-THC gummies
lack of unique MRM transitions makes the identification of isomers were bought online and named as C#1 and C#2.
problematic. Thus, given their near-identical retention times and lack of
MS-based identification, a small variation in retention time can easily 2.2. RP-UHPLC-DAD/HRMS
lead to misassignments. Kiselak et al. (Kiselak, Koerber, & Verbeck,
2020) coupled reversed phase (RP)-HPLC-MS with ion mobility spec A 1290 Infinity UHPLC system (Agilent Technologies, Santa Clara,
trometry (IMS) to investigate formed cannabinoids when converting United States) equipped with a Zorbax Eclipse Plus C18 column (2.1 ×
CBD to Δ9-THC (or Δ8-THC) at home. Even though they identified 100 mm, 1.8 μm; Agilent Technologies) was used with DAD and coupled
multiple unnatural cannabinoids, the isomers Δ9-THC and Δ8-THC were to a Q-Exactive quadrupole orbitrap high-resolution mass spectrometer
just partially separated and had the same MS fragments and collisional (Thermo Fisher Scientific, San Jose, CA, USA) via an Electrospray
cross-section, hampering identification by IMS. Apart from that, two Ionization (ESI) interface. The mobile phase consisted of 5 mM formic
compounds eluting closely to Δ8-THC and Δ9-THC with identical MS acid in water (mobile phase A) and ACN (mobile phase B). The injection
fragments and collisional cross-sections as Δ8-THC and Δ9-THC could volume was 8 µL. Isocratic elution was applied with 58 % B at a flow rate
not be unambiguously identified. Ciolino et al. (Ciolino, Ranieri, of 0.50 mL⋅min− 1, unless otherwise specified. The resolution (Rs) of two
Brueggemeyer, Taylor, & Mohrhaus, 2021) identified Δ8-THC, Δ9-THC, peaks was calculated as follows:
Δ6a,10a-THC, Δ10-THC and Δ9,11-THC in commercial vaping liquids by
tR2 − tR1
GC–MS. However, all these THC isomers had to be silylated prior to Rs =
0.85 × (W 1,h/2 + W 2,h/2 )
separation, and no absolute quantification of Δ8-THC and Δ9-THC was
achieved. Thus, despite the attention given to synthetic THC isomers tR1, tR2: retention time of two adjacent peaks; W1, h/2, W2, h/2: peak
when analyzing Δ8-THC-related products, more efforts are needed in width at half-height of two adjacent peaks.
developing analytical methods and understanding product composi Positive ionization mode MS was used with a mass resolution of
tions, especially regarding the synthetic THC isomers, for both forensic 70,000 FWHM, a maximum injection time of 200 ms, a sheath gas flow
purposes and health considerations. rate of 36 (arbitrary units), and an auxilary gas flow rate of 18 (arbitrary
In the current paper, we therefore set out to improve the analysis of units). The capillary temperature was 320 ◦ C and the S-lens RF level was
cannabinoid isomers formed in the process of converting CBD to Δ8-THC 50 (arbitrary units). All full-scan measurements were performed with a
2
S. Huang et al. Food Chemistry 440 (2024) 138187
scan range of m/z 100.0–––1500.0. A normalized collision energy (NCE) (LOQ), the peak height was used. Blanks (MeOH for RP-UHPLC-DAD and
of 40 V was applied for MS/MS fragmentation. Thermo Scientific Xca GC-FID; MeOH blow-dried and redissolved in 1 % ACN in hexane (v/v%)
libur 2.2 software was used for data acquisition and processing. The for silica-Ag(I) HPLC-DAD) were injected and standard deviations (SD)
intensity of ions with m/z values within ± 5 ppm of the theoretical m/z of the signal at the respective retention times of the analytes were
was shown in the extracted ion chromatogram (EIC). determined. The LODs and LOQs were calculated as follows: LOD = 3 ×
SD of blank/slope of the calibration curve; LOQ = 10 × SD of blank/
2.3. GC-FID/MS slope of the calibration curve (Shrivastava & Gupta, 2011; Villela, Van
der Klift, Mattheussens, Derksen, Zuilhof, & Van Beek, 2011). Samples
An Agilent 5975C VL MSD GC–MS system (Agilent, Amstelveen, the with concentrations close to the calculated LODs were tested for
Netherlands) equipped with a HP-5MS capillary column (5 % phenyl confirmation.
methylpolysiloxane, 30 m × 0.25 mm i.d. and 0.25 µm film thickness,
Agilent J&W GC column, Amstelveen, the Netherlands) was used for GC- 2.6. Preparation of mixtures containing Δ8-THC by treatment of CBD
FID/MS analysis with a split ratio of 1:1 to the FID and MS detector. The with acid
injection temperature was 250 ℃ and the carrier gas was He at a linear
velocity of 29 cm⋅s− 1. For the fast analysis of Δ8-THC, Δ9-THC and CBD, Eight reported methods (see SI, Figure S5 and Table S1) for pro
the initial column temperature was 200 ℃, which was ramped with 10 ducing “Δ8-THC” samples from CBD were carried out with minor
℃⋅min− 1 to 275 ℃ and kept at this temperature for 5 min (total analysis modifications (Kiselak et al., 2020; Marzullo et al., 2020). In summary,
time is 12.5 min). For the analysis of the five isomers and samples, a two- different catalytic conditions were employed: p-toluenesulfonic acid
step gradient temperature program was used with an initial column with varying acid quantities and solvent types (Entries 1–4), boron tri
temperature of 200 ℃, ramped with 1 ℃⋅min− 1 to 222.5 ℃. Then, the fluoride diethyl etherate (BF3⋅OEt2) catalysis in acetonitrile (Entry 5),
column temperature was ramped to 250 ℃ with 5 ℃⋅min− 1 and kept at sulfuric acid in ethanol (Entry 6), acetic acid in ethanol (Entry 7), and
this temperature for 5 min (total analysis time of 33 min). 1 µL of sample hydrochloric acid in ethanol (Entry 8). After workup (quenched with
was injected with a split ratio of 1:10. The mass spectrometer was base solutions, washed with saturated aqueous NaHCO3 and NaCl so
operated in the 70 eV electron ionization (EI) mode, scanning from m/z lutions, dried with Na2SO4 and filtered through filter paper. All eight
35 to 500 at 4 spectra⋅s− 1. Actual measurements started 3.0 min after reaction solutions were filtered through 0.2 µm PTFE membrane syringe
injection to protect the filament of the mass spectrometer. filters (∅ 13 mm, Pall Corporation, Port Washington, NY, USA), and the
solvent was evaporated under N2 flow, followed by freeze-drying
2.4. Silica-Ag(I) HPLC-DAD/MS (FreeZone 2.5 L, Labconco, Kansas City, MO, USA) at − 84 ℃ during
more than 24 h. The reaction products obtained by each method were
A 1220 Infinity II liquid chromatography system (Agilent Technol dissolved in MeOH at 100 μg⋅mL− 1 unless otherwise stated for RP-
ogies) equipped with a Nucleosil Ag(I) phase column (100 × 4.6 mm, 3 UHPLC-DAD/MS and GC-FID/MS analysis. For silica-Ag(I) HPLC-DAD/
μm; custom packed at Agilent, Middelburg, the Netherlands) was used MS analysis, 100 μL of the methanolic solution was first blow-dried with
with DAD, or with a Linear Ion Trap mass spectrometer (ESI-LXQ, N2 and re-dissolved in 100 μL of 1 % ACN in hexane (v/v%).
Thermo Fisher Scientific) via a custom-built ESI interface. Isocratic
elution was applied with 1 % ACN in hexane (v/v%) as mobile phase at a
2.7. Gummy extraction
flow rate of 1.00 mL⋅min− 1. 5 µL of sample was injected. Since hexane
cannot be easily used for stable ESI (Zhang, Wang, Zhu, Cai, & Guo,
1.00 ± 0.06 g of normal gummy or Δ8-THC gummy was weighed in a
2014), post-column mixing with a solution of AgNO3 (2.5 × 10− 5 M) in
conical stopper flask and extracted with 200.00 mL of an MTBE/water
EtOH was used to assist ESI ionization and form silver adducts (see SI,
1/1 (v/v) solution by ice bath ultrasonication (Bandelin Sonorex, Ran
Protocol S1, Figure S4). Ionization was performed in positive mode
gendingen, Germany) for up to 40 min to fully dissolve the gummies.
with capillary voltage 49 V, tube lens 85 V, capillary temperature
After waiting 10 min for phase separation, the MTBE layer was filtered
350 ◦ C, and sheath gas flow rate of 15 (arbitrary units). All full-scan
over 0.2 µm PTFE membrane syringe filters and then used for subsequent
measurements were performed with a scan range of m/z
analysis.
100.0–2000.0. For all MS/MS fragmentation measurements, collision-
induced dissociation (CID) energies were determined as the energy at
which the target product ions had the highest abundance while the 2.8. Extraction recovery
precursor ion or ions had not yet disappeared completely. The isolation
width was set to include all desired precursor ions. For accurate mass Four aliquots (1.00 mL each) of 100 μg⋅mL− 1 CBD methanolic solu
measurements of Ag(I) adducts and relevant fragments, a previously tion were blow-dried. After that, one aliquot was redissolved in MTBE
published Ag(I)-paper spray ionization method was used, in combina and subjected to GC-FID/MS analysis. The remaining three aliquots were
tion with a Q-Exactive mass spectrometer (Huang et al., 2021). reconstituted with 1.00 mL of MTBE and 1.00 mL of water, followed by
hand-shaking of 10 min. After a waiting period of 10 min for phase
separation, 60 μL of the MTBE layer was taken for GC-FID/MS analysis.
2.5. Calibration curve construction and evaluation of LOD and LOQ
( / )
Extraction recovery(%) = Aafter extraction Awithout extraction × 100.
Stock solutions of Δ8-THC, Δ9-THC, and CBD were prepared in
MeOH at 1.00 mg⋅mL− 1. Mixed standard solutions of 333, 167, 100, A is the GC-FID peak area of a specific cannabinoid.
10.0, 5.00 μg⋅mL− 1 and 0.500 μg⋅mL− 1 were prepared in triplicate by Four aliquots (100 μL each) of methanolic solution consisting of 100
mixing stock solutions and serially diluting them with MeOH, and were μg⋅mL− 1 of Δ8-THC, Δ9-THC, Δ8-iso-THC, Δ(4)8-iso-THC, and CBD (five-
analyzed by RP-UHPLC-DAD and GC-FID. For silica-Ag(I) HPLC-DAD cannabinoid solution) went through the above procedure (volumes of
analysis, considering the incompatibility of the sample solvent with the 100 μL of MTBE and 100 μL of water) to evaluate the extraction recovery
mobile phase, 100 μL of the mixed standard solution was first blow-dried of each cannabinoid.
with N2 and re-dissolved in 100 μL of mobile phase in a 1.8 mL HPLC vial
with a micro-insert (200 μL, Fisher Scientific, Warsaw, Poland). Char 2.9. Matrix effects, accuracy, and precision
acteristic peak areas were plotted against the concentration to construct
calibration curves for external standard quantification. For the deter Matrix effects. Hundred μL of 100 μg⋅mL− 1 five-cannabinoid
mination of the limit of detection (LOD) and limit of quantification methanolic solution was blow-dried and redissolved in 100 μL of
3
S. Huang et al. Food Chemistry 440 (2024) 138187
normal gummy extract for GC-FID/MS and silica-Ag(I) HPLC-DAD account if used.
analysis. The characteristic peak area of each cannabinoid in spiked
normal gummy extract (sample type II) was compared with that in 3. Results and discussion
solvent (sample type I).
3.1. RP-UHPLC-DAD/HRMS for separation and identification of Δ8-
Matrix effect(%) = ((AII /AI ) − 1 ) × 100.
THC, Δ9-THC, and CBD standards
A is the peak area of GC-FID or silica-Ag(I) HPLC-DAD (215 nm) of a
specific cannabinoid. The ever-popular Δ9-THC and CBD and increasingly popular Δ8-THC
Accuracy and precision. Accuracy and precision of the method are isomers, but have a different pharmacology, toxicology, and legal
were evaluated at three concentration levels (weight percentage w/w%: status. Therefore, discrimination and characterization of these three
low (0.02 %), medium (0.1 %) and high (0.2 %)) in normal gummy N#2 cannabinoids are of great importance. Methods applying RP-HPLC
extract (n = 3 per concentration). 100 μL of 20, 100, 200 μg⋅mL− 1 five- coupled to ultraviolet (UV) detection or DAD have been most
cannabinoid methanolic solution was spiked in 1.00 mL of normal frequently used, as reviewed recently by La Maida et al. (La Maida, Di
gummy extract N#2 (0.01 times of the total gummy weight) and blow- Giorgi, Pichini, Busardò, & Huestis, 2022). Generally, long separation
dried. Subsequently, 100 μL of MeOH was added for GC-FID/MS analysis times (>20 min) with high flow rates (>1 mL/min) have been used to
and 100 μL of 1 % ACN in hexane (v/v%) was added for silica-Ag(I) achieve partial or baseline separation of Δ8-THC and Δ9-THC, since UV
HPLC-DAD analysis. The concentration of each cannabinoid was calcu absorption spectra show no differences for the three isomers. Very
lated by the established calibration curves. recently, a reversed-phase 2D-LC system (Chan-Hosokawa et al., 2022)
The weight percentage was expressed as: and a RP superficially porous column under a multi-step gradient elution
(Reber et al., 2022) achieved separation of Δ8-THC and Δ9-THC in 10
C×V
Weight percentage (%) = × 100 min with Rs 2.5 and 1.4, respectively. Subsequently, ESI-MS/MS (MRM
W
mode) with identical transitions was used for quantification.
C: calculated concentration in extract (μg⋅mL− 1); V: volume of In the present study, Δ8-THC and Δ9-THC were, after optimization,
extraction (mL); W: total gummy weight (μg). also resolved (Rs = 1.8) by reversed-phase UHPLC (Fig. 1A, and SI,
Precision was calculated as the relative standard deviation (RSD%) Table S2 and Figure S6). When coupled to DAD and HRMS detectors, as
(n = 3). Accuracy was calculated as the relative deviation (%) of the expected, there was no selectivity in the UV absorption (SI, Figure S7),
calculated mean value of weight percentage from the respective refer nor in the high-resolution mass spectra in positive ionization mode
ence value. (Fig. 1B), as described in other references (Chan-Hosokawa et al., 2022;
Lin, Amaratunga, Reed, Huang, Lemberg, & Lemberg, 2022; Reber et al.,
2.8. Cannabinoid gummy analysis 2022). The attribution of compounds can thus only be made by com
parison of chromatographic retention times (RTs) with the standards.
Cannabinoid gummy C#1 and C#2 were extracted as described However, if the RT shifts slightly across samples due to e.g., column
above (n = 3). 1.00 mL of the MTBE layer was filtered and then sub degradation, sample overloading, variations of mobile phase, column
jected to the analysis by GC-FID/MS and silica-Ag(I) HPLC-DAD temperature, pressure, incorrect analysis might ensue (Wang et al.,
methods for quantification of Δ8-THC. For the quantification of other 2019). Moreover, any co-eluting matrix compound or isomer would be
cannabinoids, the filtrate of the MTBE layer was concentrated 20 times detrimental to the performance, due to many shared fragments between
by blow-drying and reconstitution before analysis. The percentage was those. Therefore, improved chromatographic separation and more
expressed as aforementioned with a concentrating factor taken into
Fig. 1. Δ8-THC, Δ9-THC, and CBD standards analyzed by (A) RP-UHPLC-DAD, (B) RP-UHPLC-HRMS/MS of [M + H]+, (C) GC-FID, (D) GC-EI-MS, (E) silica-Ag(I)
HPLC-DAD and (F) silica-Ag(I) HPLC-MS/MS of [M + Ag]+.
4
S. Huang et al. Food Chemistry 440 (2024) 138187
specific MS information are needed. 3.4. Resolving THC isomers by RP-UHPLC-DAD/HRMS, GC-FID/MS,
and silica-Ag(I) HPLC-DAD/MS
5
S. Huang et al. Food Chemistry 440 (2024) 138187
Fig. 2. Δ8-iso-THC, Δ(4)8-iso-THC, Δ8-THC, Δ9-THC, and CBD were analyzed by (A) RP-UHPLC-DAD, (B) RP-UHPLC-HRMS/MS of [M + H]+, (C) GC-FID, (D) GC-EI-
MS, (E) silica-Ag(I) HPLC-DAD and (F) silica-Ag(I) HPLC-MS/MS of [M + Ag]+.
propose a mechanism for the MS fragmentation of Δ8-THC in the pres hand, similar to Δ9-THC (Huang et al., 2021), [Δ8-THC + Ag]+ adducts
ence of Ag(I). The accurate mass of Δ8-THC Ag(I) adducts and their could lose AgH during the MS2 stage to form the fragment at m/z 313
fragments were determined by Ag(I) paper spray-HRMS and plausible stabilized by the aromatic ring with the phenolic group (path ②).
structures and their formation are presented in Fig. 3. The [Δ8-THC + However, since the C– –C double bond of Δ8-THC is between carbon
Ag]+ adduct loses AgH during the MS2 stage to form a tertiary carbo atoms 8 and 9 instead of 9 and 10, the fragment is less stable than that of
cation (path ①). This carbocation undergoes methyl migration and Δ9-THC. Additionally, the steric hindrance from the aromatic ring
rearrangement to form a new carbocation, stabilized by the lone pair on makes the H− loss from carbon atom 10 as AgH less favored compared
the oxygen. Afterward, a stable structure at m/z 245 was formed by the with path ①. Combined, for Δ8-THC, the signal at m/z 313 is less
retro-Diels–Alder rearrangement (Tureček & Hanuš, 1984). On the other abundant than the signal at m/z 245. These distinctive MS2 signals could
6
S. Huang et al. Food Chemistry 440 (2024) 138187
thus be used for further confirmation of Δ8-THC, Δ9-THC, and CBD, in additionally, Δ8-iso-THC was found. Compared with #1 and #2 (toluene
addition to assignments according to HPLC retention times of standards. as solvent), there was a trend of solvent selectivity, with toluene yielding
more Δ9-THC and DCM or hexane more Δ8-THC. When using BF3⋅OEt2
3.5. Investigation of acid-treated CBD mixtures by RP-UHPLC-DAD/ as a catalyst and performing the reaction at − 10 ℃ in ACN, Δ8-THC and
HRMS, GC-FID/MS, and silica-Ag(I) HPLC-DAD/MS Δ9-THC concentrations decreased, and instead, Δ8-iso-THC and Δ(4)8-
iso-THC dominated. In #6, #7 and #8, easily-accessible materials,
The increasing popularity of Δ8-THC products and the insufficient namely ethanol (solvent), and battery acid (37 % sulfuric acid), vinegar
analysis of their composition threaten consumer health and induce po (5.4 % acetic acid), or muriatic acid (30 % hydrochloric acid) were used,
tential legal issues. By following several common acid catalysis-based respectively, and the reactions were conducted at 70 ℃, which can be
protocols to produce Δ8-THC from CBD, a better understanding is ex performed with ease in a home kitchen. In #6, four THC isomers were
pected of the possible byproducts or impurities accompanying Δ8-THC. formed, predominately Δ8-iso-THC, and only a bit of CBD remained
Briefly, different acids, solvents, and conditions were used to treat CBD. unreacted. A similar profile was found for #8, except that no CBD was
Among those protocols, concerningly, some materials and procedures found and less Δ8-THC was detected. Contrary to #6, in #7, no THC
can be easily accessed and followed, and thus are described online for isomers were formed and mainly unreacted CBD was detected.
home-making of Δ8-THC. These acid-treated CBD mixtures were then Except for the peaks identified by comparison with the five reference
analyzed by the developed methods in this study to investigate the cannabinoids, there are multiple additional peaks in each. Three of them
composition. Even though the optimized RP-UHPLC-DAD/MS method (initially named X1, X2, and X3) were isolated and RP-UHPLC-DAD/
properly resolved Δ8-THC, Δ9-THC, and CBD, it still cannot provide HRMS, GC-FID/MS, and silica-Ag(I) HPLC-DAD/MS (SI, Figure S14)
accurate identification of all compounds in the samples, as these (by the analysis were performed. RP-UHPLC could resolve them and X3 had the
other two methods) were shown to contain multiple THC isomers like same RT as CBD. The three isolated compounds also had the same UV
Δ8-isoTHC and Δ(4)8-iso-THC. Therefore, GC-FID/MS and silica-Ag(I) spectrum (SI, Figure S7), identical MS signal at m/z 315.2319 ([M +
HPLC-DAD/MS were used to investigate these acid-treated CBD H]+, C21H31O2) (SI, Figure S10), and MS2 fragments (SI, Figure S15) as
mixtures. Δ8-THC, Δ9-THC and CBD of m/z 315.2319. Apart from that, they all
First, the occurrence of Δ8-THC, Δ9-THC, CBD, Δ8-isoTHC and Δ(4)8- showed an extra signal in full scan MS at m/z 333.2408 (C21H33O3) (SI,
iso-THC was checked by comparing the respective retention times and Figure S10), which during fragmentation produced [M − 18]+, likely
mass spectra (SI, Figure S13) with those of the standards. As shown in resulting from the loss of H2O, at m/z 315.2319 (C21H31O2) (SI,
Fig. 4, the product profiles vary substantially from protocol to protocol. Figure S16). Separation by the GC method showed molecular ion at m/z
In mixtures #1 and #2, CBD was not fully consumed and the major 332 (SI, Figure S17) for all three, confirming a molecular weight of 332
product is Δ9-THC followed by Δ8-THC, and then a little Δ8-iso-THC. Da. Furthermore, the three compounds shared EI fragments at m/z 314
Increasing the amount of acid (molar ratio of acid to CBD from 0.1 to 2) and 231 with Δ8-THC, Δ9-THC and CBD, implying a similar chemical
increased the conversion of CBD. In mixtures #3 and #4, the main structure. On the silica-Ag(I) HPLC column, the three compounds
product is Δ8-THC accompanied by trace amounts of Δ9-THC. Δ(4)8-iso- showed similar retention time (7.57 min for X1, 7.89 min for X2, and
THC was also detected in these two mixtures. When applying hexane as 7.48 min for X3) and clear Ag(I) adduct signals at m/z 439/441 ([M +
solvent (#4), Δ(4)8-iso-THC signal was more pronounced, and Ag]+) and m/z 771/773 ([2 M + Ag]+) (SI, Figure S18), again
Fig. 4. Detection of Δ8-THC, Δ9-THC, CBD, Δ8-iso-THC, and Δ(4)8-iso-THC in acid-treated CBD mixtures by (A) GC-FID and (B) silica-Ag(I) HPLC-DAD (215 nm).
7
S. Huang et al. Food Chemistry 440 (2024) 138187
confirming a molecular weight of 332 Da for the three compounds. All Table 1
combined, the three compounds were expected to be hydrated forms of Percentage (w/w%, after solvent evaporation) of Δ8-THC, Δ9-THC and CBD in
Δ8-THC, Δ9-THC or CBD. Finally, by performing 700 MHz NMR analysis acid-treated CBD mixtures analyzed by silica-Ag(I) HPLC-DAD (215 nm) and GC-
(SI, Figure S19) and comparison with recently identified cannabinoids FID.
(Cheng, Xie, Chen, Wang, & Zhou, 2013; Radwan, Wanas, Gul, Ibrahim, Sample Δ8-THC (w/w%) Δ9-THC (w/w%) CBD (w/w%)
& ElSohly, 2023), the compounds were assigned as follows: X1 = 9β- GC- Ag-LC- GC- Ag-LC- GC- Ag-LC-
hydroxyhexahydrocannabinol; X2 = 9α-hydroxyhexahydrocannabinol; FID DAD FID DAD FID DAD
X3 = 8-hydroxy-isotetrahydrocannabinol. These compounds were #1 11 9.4 49 49 26 28
observed in mixtures #3, 4, 6, and 8 by the GC-FID method, and in (2.6 (2.1 %) (0.3 (2.6 %) (2.0 (2.4 %)
mixtures #1, 2, 3, 4, 5, 6, and 8 by the more sensitive RP-UHPLC-DAD %) %) %)
method (SI, Figure S20). These findings suggest that these com #2 26 25 48 49 6.9 8.6
(4.0 (3.9 %) (0.1 (3.0 %) (0.4 (5.2 %)
pounds, of which there is currently no toxicological knowledge, occur in
%) %) %)
many of these CBD reaction mixtures, which warrants further #3 78 89 1.6* 1.5* ND ND
investigation. (2.1 (4.0 %) (1.1 (11 %)
In addition to these five THC isomers and three hydrated THC iso %) %)
mers, several minor peaks (especially in the last three samples) can be #4 70 70 1.1* 1.1** ND ND
(1.8 (4.6 %) (5.6 (7.0 %)
observed, reflecting the complexity of the product mixtures obtained by %) %)
treating CBD with acids. There is little information regarding the toxicity #5 14 14 6.3 5.9 ND ND
and pharmacokinetics of Δ8-THC, and nothing about Δ8-iso-THC, Δ(4)8- (3.7 (6.7 %) (5.2 (5.7 %)
iso-THC. Since these eight samples were converted from CBD by both %) %)
#6 8.1 6.5 8.9 8.2 4.2 3.5
lab-based protocols and kitchen-based protocols, they reflect, to some
(0.5 (14.4 %) (1.2 (6.3 %) (0.2 (6.9 %)
extent, the uncertainties about the composition of existing Δ8-THC %) %) %)
products in the market, and point to potential risks for Δ8-THC #7 ND ND ND ND 48 53
consumers. (0.7 (12 %)
%)
#8 1.4 1.6* 5.0 4.8* ND ND
3.6. Quantification of Δ8-THC, Δ9-THC, CBD, Δ8-iso-THC, and Δ(4)8-iso- (1.1 (4.6 %) (2.5 (3.6 %)
THC by RP-UHPLC-DAD, GC-FID, and silica-Ag(I) HPLC-DAD %) %)
8
S. Huang et al. Food Chemistry 440 (2024) 138187
3.7. Analysis of cannabinoid-infused gummies and evaluation of accuracy and precision at three different spiking weight percentages
extraction recovery, matrix effects, accuracy, and precision 0.02 %, 0.1 %, and 0.2 % (low, medium, and high) were assessed. As
shown in Table S8 (SI), both methods showed acceptable accuracy (bias
Previous experiments were focused on analyzing acid-treated CBD from − 12 % to 19 %) (Scientific Working Group for Forensic Toxicology
mixtures to understand which cannabinoids might be present after the (SWGTOX) standard practices for method validation in forensic toxi
chemistry, prior to infusion into edibles. While complex due to presence cology, 2013) and good precision (RSD 0.26–6.1 %) for all investigated
of isomers, as alluded to, the analysis is not complicated in terms of the cannabinoids at different spiking weight percentages. The silica-Ag(I)
matrix, as a fairly clean solution is obtained. To further explore the HPLC-DAD method exhibited better accuracy than the GC-FID/MS
application potential of the developed methods, the composition of method in general (bias − 12–8.6 % vs 3.0–19 %).
cannabinoid-infused edibles was assessed. An extraction and analysis Analysis of Δ8-THC gummies. Finally, two Δ8-THC gummies were
protocol was developed for infused gummies, and extraction recovery, analyzed by the developed methods (SI, Figure S28) and weight per
matrix effects, accuracy, and precision were evaluated. centages of five isomeric cannabinoids were compared with the declared
Extraction recovery. Neutral cannabinoids are relatively non-polar information in the certificate of analysis (Table 2). The results obtained
and are well-soluble in e.g., ethanol, hexane, and MTBE (López-Olmos, by the two developed methods nicely corresponded. For sample C#1,
García-Valverde, Hidalgo, Ferrerio-Vera, & Sánchez de Medina, 2022). Δ8-THC (0.63 % by silica-Ag(I) HPLC-DAD and 0.68 % by GC-FID in this
Major components of gummies (gelatin, starch, sugars, flavors, and study vs 0.65 % as declared), Δ9-THC (0.015 % by silica-Ag(I) HPLC-
colorants), are well-soluble in water (Burey, Bhandari, Rutgers, Halley, DAD and 0.014 % by GC-FID in this study vs < 0.050 % as declared) and
& Torley, 2009). Therefore, a liquid–liquid extraction (LLE) with MTBE CBD (not detected in all cases) results matched well with the declared
and water (1/1, v/v) was applied considering the higher polarity and contents. However, for sample #2, a lower content of Δ8-THC (2.8 % by
lower toxicity of MTBE compared with hexane, as well as lower polarity silica-Ag(I) HPLC-DAD and 2.9 % by GC-FID in this study vs 3.1 % as
than ethanol to exclude co-extracting of flavors and colorants (López- declared) and higher content of Δ9-THC (0.099 % by silica-Ag(I) HPLC-
Olmos, García-Valverde, Hidalgo, Ferrerio-Vera, & Sánchez de Medina, DAD and 0.086 % by GC-FID in this study vs < 0.074 % as declared) were
2022). Three normal gummies and two Δ8-THC gummies were dissolved detected by the developed methods in this study, whereas the declared
during ice-bath sonication for 20–40 min. After phase-separation, a CBD content matches with our results (not detected in this study vs <
colorless, clear, and transparent MTBE layer was obtained(SI, 0.0010 % as declared). Moreover, Δ8-iso-THC and Δ(4)8-iso-THC, about
Figure S24). To evaluate the partitioning of cannabinoids between which no information is provided in the certificate of analysis, were
MTBE and water phases, CBD was first used as a representative canna found in both tested samples. C#1 only contained a small amount of Δ(4)
8
binoid and showed an extraction recovery of 101 ± 0.3 % with a total -iso-THC (0.031 % by silica-Ag(I) HPLC-DAD and 0.033 % by GC-FID)
volume of extraction solvent of 2.00 mL, as determined by GC-FID. Af and no Δ8-iso-THC but C#2 contained higher amounts of Δ(4)8-iso-THC
terwards, the five cannabinoid mixtures were also tested in the same (0.13 % by silica-Ag(I) HPLC-DAD and 0.12 % by GC-FID) and Δ8-iso-
way with a smaller volume of extraction solvent (200 µL), and the THC(0.0072 % by silica-Ag(I) HPLC-DAD and 0.0069 % by GC-FID). On
extraction recovery for different cannabinoid varied from 100 ± 17 % to the one hand, the presence of Δ(4)8-iso-THC and Δ8-iso-THC could partly
101 ± 16 % (SI, Table S5). Despite the large relative standard deviation explain the overestimation of Δ8-THC in the certificate of analysis
(RSD 15–17 %), which can be attributed to the small extraction volume (reversed-phase HPLC-UV method was used). Crucially, such analysis
as it was not observed during the CBD extraction with 2 mL, all tested highlights the necessity of methods to distinguish between THC isomers,
cannabinoids show approximately 100 % extraction recovery. such as demonstrated in this work. Moreover, it demonstrates the
Matrix effects. Next, matrix effects of the gummies on the two importance of providing qualitative and quantitative information to
analytical methods were evaluated. Considering the unclear composi consumers, especially due to the fact that intoxication cases induced by
tional information of commercial Δ8-THC gummies, as well as the di consuming Δ8-THC gummies have already been reported (Akpunonu
versity of gummies in terms of composition, texture, and solubility (SI, et al., 2021).
Table S6), three varieties of normal gummies without cannabinoids
were tested. For the GC-FID/MS method, the extractions of three normal 4. Conclusions
gummies showed minor peaks, which were all distinct from peaks of the
tested cannabinoids (SI, Figure S25). Matrix effects for the five canna Three methods based on RP-UHPLC-DAD/HRMS, silica-Ag(I) HPLC-
binoids varied from − 2.6 % to 14 % (SI, Table S7). For the silica-Ag(I) DAD/MS, and GC-FID/MS have been developed for the analysis of Δ8-
HPLC-DAD method, extractions of all three normal gummies exhibited a THC related products with special emphasis on THC isomers. RP-
clean background (SI, Figure S26), possibly due to the reconstitution UHPLC-DAD/MS provides sufficient separation of Δ8-THC, Δ9-THC,
step by a different solvent (mobile phase, 1 % ACN in hexane (v/v%)) and CBD and is the most sensitive method. However, this method cannot
with different polarity from the extraction solvent MTBE, which pro resolve Δ8-THC from the interferences Δ(4)8-iso-THC and Δ8-iso-THC in
vided further selectivity. At the same time, the additional blow-drying “Δ8-THC” samples and gives identical MS/HRMS spectra for all five
and reconstitution potentially introduced experimental errors, espe isomers. GC-FID/MS separated the five isomers with a two-step gradient
cially due to the small sample volume (100 µL). Therefore, even though temperature program in 33 min, and all isomers showed different EI
theoretically the silica-Ag(I) HPLC-DAD method should have limited spectra that thus allows identification. With an analysis time of 40 min,
matrix effects with the three tested normal gummies, deviations of − 9.6 silica-Ag(I) HPLC-DAD/MS also achieved sufficient separation of the
% to 11 % were observed for different cannabinoids (SI, Table S7), five isomers. Importantly, unique Ag(I) adduct fragmentation mass
although this can likely be improved when larger sample volumes are spectra for Δ8-THC, Δ9-THC, CBD, Δ8-iso-THC, and Δ(4)8-iso-THC were
used. In summary, the two developed methods showed acceptable ma obtained, which cannot be achieved by HRMS with protonated adducts.
trix effects (Scientific Working Group for Forensic Toxicology The GC-FID/MS method is faster and more robust in the analysis of
(SWGTOX) standard practices for method validation in forensic toxi cannabinoid mixtures, such as “Δ8-THC” products, while silica-Ag(I)
cology, 2013) with signal suppression < 10 % and signal enhancement HPLC-DAD/MS provides an orthogonal method and distinct ESI
< 14 % for five cannabinoids in three tested normal gummies. spectra towards THC isomers. By analyzing eight of such “Δ8-THC”
Accuracy and precision. Furthermore, accuracy and precision were samples from lab-based and kitchen-based syntheses starting from CBD,
evaluated by spiking standards into normal gummy #2, which was most potential issues are revealed with regard to Δ8-THC edibles and other
similar in texture and solubility to the tested commercial Δ8-THC products in the market, including various amounts of Δ8-THC (0–89 %),
gummies. Five-point calibration curves of Δ8-THC, Δ9-THC, CBD, Δ(4)8- illegal levels of Δ9-THC of up to nearly 50 %, and the presence of other
iso-THC, and Δ8-iso-THC were established (SI, Figure S27) and known THC isomers and hydrated THC isomers. Subsequently,
9
S. Huang et al. Food Chemistry 440 (2024) 138187
information
information
Declared*
cannabinoid isomers compared to the GC-FID/MS method. Finally, two
commercial Δ8-THC gummies were analyzed, and both Δ8-iso-THC and
No
No
Δ(4)8-iso-THC were observed. The existence of such, typically unspeci
fied, THC isomers tends to result in overestimated Δ8-THC content, as
evidenced by the certificate of analysis in which a reversed-phase HPLC-
(2.6 %)
(6.8 %)
Ag-LC-
0.031
DAD UV method (with limited resolution towards Δ8-THC, Δ8-iso-THC and
0.13
Percentage (w/w%) of Δ8-THC, Δ9-THC, Δ8-isoTHC, Δ(4)8-iso-THC in Δ8-THC gummies analyzed by silica-Ag(I) HPLC-DAD (215 nm) and GC-FID and compared with claimed information.
Δ(4)8-isoTHC
in the certificate of analysis was found for one of the two gummies. In
0.033
0.12
short, the developed silica-Ag(I) HPLC-DAD/MS method and GC-FID/
(2.3
(1.9
GC-
FID
%)
%)
MS method showed good applicability in the analysis of cannabinoid
products. From a food science perspective, attention should be paid to
cannabinoid isomers when analyzing cannabinoid products, considering
their common existence, varied health effects and legal status. More
information
information
Declared*
No
curate and complete information. From the analysis of real food prod
ucts in this work, it is clear that such analytical methods are needed to
provide a more complete overview of their cannabinoid profile. More
(3.7 %)
0.0072
Ag-LC-
over, such methods could lay the foundation for future investigations
DAD
ND
(2.6 %)
GC-FID
0.0069
ND
ND
ND
GC-
FID
ND
ND
Data availability
(4.7 %)
(3.1 %)
Ag-LC-
0.015
0.099
DAD
Acknowledgements
Δ9-THC
0.014
0.086
(4.4
(3.4
GC-
FID
%)
%)
The authors thank prof. Daniele Passarella group from the Diparti
mento di Chimica, Università degli Studi di Milano, Milano, Italy for
kindly providing Δ8-iso-THC and Δ(4)8-iso-THC, dr. Muthusamy Sub
Declared*
3.1
(1.4 %)
Ag-LC-
DAD
0.63
2.8
(1.3
GC-
FID
2.9
%)
%)
C#2
10
S. Huang et al. Food Chemistry 440 (2024) 138187
DAD/MS; synthesis of acid-treated CBD mixtures and analysis of these Helander, A., Johansson, M., Andersson, A., & Villén, T. (2022). Analytical and medico-
legal problems linked to the presence of delta-8-tetrahydrocannabinol (delta-8-
samples by RP-UHPLC-DAD/MS, GC-FID/MS, and silica-Ag(I) HPLC-
THC): Results from urine drug testing in Sweden. Drug testing and analysis, 14(2),
DAD/MS; analysis of 9β-hydroxyhexahydrocannabinol, 9α-hydrox 371–376.
yhexahydrocannabinol, and 8-hydroxy-iso-tetrahydrocannabinol by RP- Huang, S., Claassen, F. W., van Beek, T. A., Chen, B., Zeng, J., Zuilhof, H., &
UHPLC-DAD/MS, GC-FID/MS, silica-Ag(I) HPLC-DAD/MS, and NMR; Salentijn, G. I. (2021). Rapid distinction and semiquantitative analysis of THC and
CBD by silver-impregnated paper spray mass spectrometry. Analytical chemistry, 93
calibration curves of Δ8-THC, Δ9-THC, and CBD; content of Δ8-THC, Δ9- (8), 3794–3802.
THC, and CBD in acid-treated CBD mixtures analyzed by silica-Ag(I) Huang, S., Qiu, R., Fang, Z., Min, K., Van Beek, T. A., Ma, M., Chen, B., Zuilhof, H., &
HPLC-DAD and GC-FID; analysis of gummies and evaluation of extrac Salentijn, G. I. (2022). Semiquantitative Screening of THC Analogues by Silica Gel
TLC with an Ag (I) Retention Zone and Chromogenic Smartphone Detection.
tion recovery, matrix effects, accuracy, and precision of silica-Ag(I) Analytical Chemistry, 94(40), 13710–13718.
HPLC-DAD and GC-FID. Supplementary data to this article can be Kaneti, J., de Smet, L. C., Boom, R., Zuilhof, H., & Sudhölter, E. J. (2002). Computational
found online at https://doi.org/10.1016/j.foodchem.2023.138187. probes into the basis of silver ion chromatography. II. Silver (I)− olefin complexes.
The Journal of Physical Chemistry A, 106(46), 11197-11204.
Kiselak, T. D., Koerber, R., & Verbeck, G. F. (2020). Synthetic route sourcing of illicit at
References home cannabidiol (CBD) isomerization to psychoactive cannabinoids using ion
mobility-coupled-LC–MS/MS. Forensic science international, 308, Article 110173.
La Maida, N., Di Giorgi, A., Pichini, S., Busardò, F. P., & Huestis, M. A. (2022). Recent
Adlof, R. O. (1997). Normal-phase separation effects with lipids on a silver ion high-
challenges and trends in forensic analysis: Δ9-THC isomers pharmacology,
performance liquid chromatography column. Journal of Chromatography A, 764(2),
toxicology and analysis. Journal of Pharmaceutical and Biomedical Analysis, 220,
337–340.
Article 114987.
AOAC. (2017). AOAC SMPR® 2017.019 Standard Method Performance Requirements
Lachenmeier, D. W., Habel, S., Fischer, B., Herbi, F., Zerbe, Y., Bock, V., … Sproll, C.
(SMPRs®) for Quantitation of Cannabinoids in Edible Chocolate. Retrieved from:
(2022). Are adverse effects of cannabidiol (CBD) products caused by
https://www.aoac.org/wp-content/uploads/2020/11/SMPR202017_019.pdf
tetrahydrocannabinol (THC) contamination? F1000Research, 8, 1394.
Accessed April 21, 2023.
Leas, E. C., Nobles, A. L., Shi, Y., & Hendrickson, E. (2022). Public interest in Δ8-
Abrahamov, A., Abrahamov, A., & Mechoulam, R. (1995). An efficient new cannabinoid
Tetrahydrocannabinol (delta-8-THC) increased in US states that restricted Δ9-
antiemetic in pediatric oncology. Life Sciences, 56(23), 2097–2102.
Tetrahydrocannabinol (delta-9-THC) use. International Journal of Drug Policy, 101,
Akpunonu, P., Baum, R. A., Reckers, A., Davidson, B., Ellison, R., Riley, M., … Gerona, R.
Article 103557.
(2021). Sedation and acute encephalopathy in a pediatric patient following ingestion
Lin, L., Amaratunga, P., Reed, J., Huang, P., Lemberg, B. L., & Lemberg, D. (2022).
of delta-8-tetrahydrocannabinol gummies. The American Journal of Case Reports, 22,
Quantitation of Δ8-THC, Δ9-THC, cannabidiol and 10 other cannabinoids and
e933481–e933488.
metabolites in oral fluid by HPLC–MS-MS. Journal of Analytical Toxicology, 46(1),
Burey, P., Bhandari, B., Rutgers, R., Halley, P., & Torley, P. (2009). Confectionery gels: A
76–88.
review on formulation, rheological and structural aspects. International Journal of
LoParco, C. R., Rossheim, M. E., Walters, S. T., Zhou, Z., Olsson, S., & Sussman, S. Y.
Food Properties, 12(1), 176–210.
(2023). Delta-8 tetrahydrocannabinol: A scoping review and commentary. Addiction,
Casajuana Kögel, C., López-Pelayo, H., Balcells-Olivero, M. M., Colom, J., & Gual, A.
1–18.
(2018). Psychoactive constituents of cannabis and their clinical implications: A
López-Olmos, C., García-Valverde, M. T., Hidalgo, J., Ferrerio-Vera, C., & Sánchez de
systematic review. Adicciones, 30(2), 140–151.
Medina, V. (2022). Comprehensive comparison of industrial cannabinoid extraction
Chan-Hosokawa, A., Nguyen, L., Lattanzio, N., & Adams, W. R. (2022). Emergence of
techniques: Evaluation of the most relevant patents and studies at pilot scale.
Delta-8 Tetrahydrocannabinol in DUID Investigation Casework: Method
Frontiers in Natural Products, 1, 1043147.
Development, Validation and Application. Journal of Analytical Toxicology, 46(1),
Marzullo, P., Foschi, F., Coppini, D. A., Fanchini, F., Magnani, L., Rusconi, S., …
1–9.
Passarella, D. (2020). Cannabidiol as the Substrate in Acid-Catalyzed Intramolecular
Christinat, N., Savoy, M.-C., & Mottier, P. (2020). Development, validation and
Cyclization. Journal of Natural Products, 83(10), 2894–2901.
application of a LC-MS/MS method for quantification of 15 cannabinoids in food.
Meehan-Atrash, J., & Rahman, I. (2021). Novel Δ8-tetrahydrocannabinol vaporizers
Food Chemistry, 318, Article 126469.
contain unlabeled adulterants, unintended byproducts of chemical synthesis, and
Ciolino, L. A., Ranieri, T. L., Brueggemeyer, J. L., Taylor, A. M., & Mohrhaus, A. S.
heavy metals. Chemical research in toxicology, 35(1), 73–76.
(2021). EVALI vaping liquids part 1: GC-MS cannabinoids profiles and identification
Peng, H., & Shahidi, F. (2021). Cannabis and Cannabis Edibles: A Review. Journal of
of unnatural THC isomers. Frontiers in Chemistry, 9, Article 746479.
Agricultural and Food Chemistry, 69(6), 1751–1774.
Czégény, Z., Nagy, G., Babinszki, B., Bajtel, Á., Sebestyén, Z., Kiss, T., … Csupor, D.
Pisciottano, I. D. M., Guadagnuolo, G., Soprano, V., Esposito, M., & Gallo, P. (2021).
(2021). CBD, a precursor of THC in e-cigarettes. Scientific Reports, 11(1), 8951.
A survey of Δ9-THC and relevant cannabinoids in products from the Italian market: A
AOAC. (2022). AOAC SMPR 2022.001; Quantitation of cannabinoids in beverages.
study by LC–MS/MS of food, beverages and feed. Food Chemistry, 346, Article
Retrieved from: https://www.aoac.org/wp-content/uploads/2022/11/SMPR-2022
128898.
_001.pdf Accessed December 20, 2023.
Reber, J. D., Karschner, E. L., Seither, J. Z., Knittel, J. L., Dozier, K. V., &
Congress, U. S. (2018). Agriculture Improvement Act of 2018. Retrieved from: htt
Walterscheid, J. P. (2022). An Enhanced LC–MS-MS Technique for Distinguishing
ps://www.congress.gov/115/plaws/publ334/PLAW-115publ334.pdf Accessed April
Δ8- and Δ9-Tetrahydrocannabinol Isomers in Blood and Urine Specimens. Journal of
21, 2023.
Analytical Toxicology, 46(4), 343–349.
Council, U. S. C. (2021). The unregulated distribution and sale of consumer products
Radwan, M. M., Wanas, A. S., Gul, W., Ibrahim, E. A., & ElSohly, M. A. (2023). Isolation
marketed as delta-8 THC. Retrieved from: https://irp.cdn-website.com/6531d7ca/fi
and Characterization of Impurities in Commercially Marketed Δ8-THC Products.
les/uploaded/USCC%20Delta-8%20Kit.pdf Accessed April 21, 2023.
Journal of Natural Products, 86(4), 822–829.
Citti, C., Linciano, P., Forni, F., Vandelli, M. A., Gigli, G., Laganà, A., & Cannazza, G.
Shrivastava, A., & Gupta, V. B. (2011). Methods for the determination of limit of
(2019). Analysis of impurities of cannabidiol from hemp. Isolation, characterization
detection and limit of quantitation of the analytical methods. Chronicles of Young
and synthesis of cannabidibutol, the novel cannabidiol butyl analog. Journal of
Scientists, 2(1), 21–25.
Pharmaceutical and Biomedical Analysis, 175, Article 112752.
Song, L., Meyer, G., Adejumo, E., Jovanovich, E., LeBlanc, L., & Provis, J. (2023).
Cheng, L.-J., Xie, J.-H., Chen, Y., Wang, L.-X., & Zhou, Q.-L. (2013). Enantioselective
Potency testing of up to sixteen cannabinoids in hemp-infused edibles using liquid
Total Synthesis of (− )-Δ8-THC and (− )-Δ9-THC via Catalytic Asymmetric
chromatography diode array detector with optional confirmation of identity by
Hydrogenation and SNAr Cyclization. Organic Letters, 15(4), 764–767.
electrospray ionization time-of-flight mass spectrometry. Food Chemistry, 417,
Cuadros-Rodríguez, L., Bagur-González, M. G., Sánchez-Viñas, M., González-Casado, A.,
Article 135819.
& Gómez-Sáez, A. M. (2007). Principles of analytical calibration/quantification for
Scientific Working Group for Forensic Toxicology (SWGTOX) standard practices for
the separation sciences. Journal of Chromatography A, 1158(1), 33–46.
method validation in forensic toxicology. (2013). Journal of Analytical Toxicology, 37
Duffy, B. C., Li, L., Lu, S., Dittmar, M. A., Delaney-Baldwin, E., Durocher, L. A., &
(7), 452-474.
Spink, D. C. (2022). Chemotyping of Δ8-THC-Containing e-Liquids Analyzed during
Tsujikawa, K., Okada, Y., Segawa, H., Yamamuro, T., Kuwayama, K., Kanamori, T., &
the 2019–2020 New York State EVALI Investigation. Journal of Analytical Toxicology,
Iwata, Y. T. (2022). Thermal decomposition of CBD to Δ9-THC during GC-MS
46(7), 743–749.
analysis: A potential cause of Δ9-THC misidentification. Forensic science international,
Gaoni, Y., & Mechoulam, R. (1968). The ISO-Tetrahydrocannabinols. Israel Journal of
337, Article 111366.
Chemistry, 6(5), 679–690.
Tureček, F., & Hanuš, V. (1984). Retro-Diels-Alder reaction in mass spectrometry. Mass
Gertsch, J. (2018). Analytical and Pharmacological Challenges in Cannabis Research.
Spectrometry Reviews, 3(1), 85–152.
Planta Med, 84(04), 213.
van Beek, T. A., & Subrtova, D. (1995). Factors involved in the high pressure liquid
Golombek, P., Müller, M., Barthlott, I., Sproll, C., & Lachenmeier, D. W. (2020).
chromatographic separation of alkenes by means of argentation chromatography on
Conversion of Cannabidiol (CBD) into Psychotropic Cannabinoids Including
ion exchangers: Overview of theory and new practical developments. Phytochemical
Tetrahydrocannabinol (THC): A Controversy in the Scientific Literature. Toxics, 8(2),
Analysis, 6(1), 1–19.
41.
Villela, A., Van der Klift, E. J., Mattheussens, E. S., Derksen, G. C., Zuilhof, H., & Van
Gülck, T., & Møller, B. L. (2020). Phytocannabinoids: Origins and biosynthesis. Trends in
Beek, T. A. (2011). Fast chromatographic separation for the quantitation of the main
plant science, 25(10), 985–1004.
flavone dyes in Reseda luteola (weld). Journal of Chromatography A, 1218(47),
Gleb, O. (2022). New leafreport research reveals more than 50% of delta-8 THC hemp-
8544–8550.
derived products tested had illegal levels of delta-9 THC. Retrieved from: https://
Wang, Y., Ma, L., Zhang, M., Chen, M., Li, P., He, C., … Wan, J.-B. (2019). A simple
www.leafreport.com/education/delta-8-thc-products-market-report-11339 Accessed
method for peak alignment using relative retention time related to an inherent peak
April 21, 2023.
11
S. Huang et al. Food Chemistry 440 (2024) 138187
in liquid chromatography-mass spectrometry-based metabolomics. Journal of Zhang, X., Geng, Z., & Wang, Y. (2011). Density functional theory study of the
chromatographic science, 57(1), 9–16. mechanism of the acid-catalyzed decarboxylation of pyrrole-2-carboxylic acid and
Zhang, J.-T., Wang, H.-Y., Zhu, W., Cai, T.-T., & Guo, Y.-L. (2014). Solvent-assisted mesitoic acid. Science China Chemistry, 54(5), 762–768.
electrospray ionization for direct analysis of various compounds (complex) from
low/nonpolar solvents and eluents. Analytical chemistry, 86(18), 8937–8942.
12