PTT TE Shown with Optional Equipment FEATURES NFPA 99/110 Alarm Modules: Functionally designedto be compatible with all existing Caterpillar alarm modules Each module has eight LEDs: 4 amber for “pre-alarms,” 4 red for “faults” Can be remotely mounted up to 1000 feet (350 m) away from control panel Lamp test and acknowledgelsilence switches All inputs and outputs are protected against short circuits to (+/+) battery Reverse polarity protection Designed for operation from 15 to 45 VDC Environmentally sealed Custom Alarm Module (CAM), above, includes: in addition to the 8 switch inputs 1 Pre-defined labels so customer can ‘customize CAM for each individual application 1 Solf-aligning template is supplied for labels Two versions available: One is fully equipped (version 1); second version is for use with other Cat Alarm Modules - Horn, AcknowledgelSilence Switch, and Lamp Test Switch, are not included (version 2) Available as an alarm module mounted on EMCP Il or asa remote annunciator module available hy itealf or with other modules No limit on the number of modules used in an application Alarm Modules NFPA 99 Alarm Modul (Local or Remote) NFPA 110 Alarm Module (Local or Remote) Custom Alarm Module (CAM) (Local or Remote) The alarm modules are designed to meet and exceed the standards of the National Fire Protection Association (NFPA), Whether customer requirements are the NFPA 99, NFPA 110 (local or remote), or any application requiring local or remote annunciation of generator set or related parameters, Caterpillar has designed a match. If additional requirements are needed, the Custom Alarm Module (CAM) has been developed to be functionally compatible with all existing alarm modules to give customers, greater flexibility in the field. SPECIFICATIONS Dimensions 3-3/8" W x 10-5/8" H x 3-3/8" D 13.31 mm W x 41.85 mm H x 13.31 mm D EMI immunity IEC 801-2, IEC 801-3, IEC 801-4, EN 5082-2 EEC Certification 89/392/EEC Enclosure single-membrane front face with integral test light and alarm silence switches Horn output: 80 dB(A) nominal Humidity © to 100% relative humility Impervious to salt spray, fuel, oil and oil additives, coolant, spray cleaners, chlorinated solvents, hydrogen sulfide and methane gas, and dust Input and output protection ail inputs and outputs are protected against short circuits to (+/-) battery Input voltage (supply) 15 to 45 VDC Power requirements ‘maximum wattage: 6 watts (all LEDs and horn on) minimum wattage: 2.2 watts Reverse polarity, protected Shock, withstands 20 g Temperature range ‘operating: -40° C to +70° CI-40" F to +158 F storage: “55° C to +85° I-67" F to +185" F Vibration withstands 2.0 g @ 18 to 500 Hz Weight 2.50 Ibs. (1.14 kgs) CATERPILLAR ALARM MODULES PREDEFINED ALARM MODULES (LED COLOR/SIGNAL SOURCE) — Local Remote’ ‘unction NFPA 99 NFPA 110 NFPA 99 NFPA 110" High Gootant | Alarm | amber/data tink | _amoeridata ink 5 ‘amberldata link Temperature Shutdown? 5 5 realdata link redidata link Taw Contant Temperature | Alarm | _amberidata tink | amseridata tink | _amberidata tink | _amber/data link Low Oit ‘Alarm | _amberldata tink | _amoeridata tink 5 ‘amberldata link Pressure Shutdown? : : redldata ink reddat link Low Fuel Level_| Alarm | amber/switch input [amberiswitch input | amber/switch input | amber/switch input Not in Auto ‘Alarm | _redidata tink redita link E ‘amberidata link Low DC Vottage| Alarm | redlinternal source | rediinternal source 7 e Batt. Charger Malfunction Alarm E reaiswitch input _| amber/switch input : ‘Air Damper Closed Alarm : rediswiteh input : 2 ‘Generator on Load, Status E E amberlswiteh input e ‘Overcrank ‘Shutdown e e redidata link redidata link ‘Overspeed | Shutcown? Es Es redldata link edicata tink ‘Spare Faults ‘Alarm | 2rediswitch inputs - : 4red, 3 amber! ‘switch inputs ‘Data nk gral rom EMGP Rien iu poaroes egins cana Usea proman ow rut even spares “Lael indication provided by ECM ALARM MODULE Terminal Strip Connection Diagram ‘Serew Local Remote Gt 8 CJ [terminal FPA 20 NFPA 110 NFPA 99 NFPA 110 1 8 Be 8 Be Or °C] [wen Bae Batain Batain 3 we 3 Hom int Hom in Homint Hom int 4 Hom in2 Hom in? Hom in? Hom in2 Qt 11 GO] [Es [iroae ser rine) [mode Sette) | “Mode S076) [Mode So (WO) © | Mode Serio) | Mode Sei2 (61 | Mode Sei2 (No) _| Mode Sei2 6) Os Olt . . e . 6 on @ _[Stdowtuetteven| Stow fucttevel) | St(owivelleve) | S1(NO) 3 S2(NO) S2(NO) S2INO) S28) 8 7 “4 8S 10 'S3 (Spare) _| $3 (batt chgmifunct) | $3 (gen on load) 'S3 (NC) n S4(Spare) _ | St (ir damper closed) [53 (bat chgmitunc)| $4 (NG) 12 [ker Tet Lave Tent Tan Test Lane 13 | AawSitence ‘RcxSilence | ‘ckiSitence | _AckSilence 14 [Horm Output Horn Ouipat Horn Output | Horn Output ALARM MODULES CATERPILLAR’ CUSTOM ALARM MODULE (CAM) Terminal Strip Connection Points cana 1 8 4 Be — — z NC 5 0 3 LED 5 (red) 4 LED 6 (red) Aeon 5 LED 7 (red) 6 LEDS (red) 7 8. aM 8 LED 7 (amber a LED 2 (amber) ae 70 LED 3 (amber = n LED 4 (amnben Uw 12 Lamp Test 13 ‘AckiSilence 7 4 4 Horn Output CAM ANNUNCIATOR PRE-PRINTED LABELS: } Label Size | Sin Y <—_to-= itn Tounctive [ruGameT ]encwe penareo] sacnue Towcoounr | Revore lencon Tan cootanr FauComesenr | kietiwe — |auFHoFoR™ [poMonune — [emernrone | EMenctucy — forcarce | eemenaTune wanawe | Aitube wasnine | Stas foren TEMVOLTAGE | Low cooLaN_|EncINe GENERATOR [aca cootanT | Rewore Tow COOLANT | HGR EXAUST waren | LEVECWaRWIc | SHUTDOWm | ONLINE ‘ewwenature |ewencency — |UEVEL eas re Stor Wenn ‘icne ox | Lowruet [ence ox —[ARSRUTOFF | GENERATOR | euenceney —|LOW STARTING | wicHEXXAUST pressure | LEVEL Waewn| pressure — |Oaweer [ONLOAD | StaRr Japressure | Gas remo Warning SHUTDOWN Sturoown JACKET WATER | BATT. CHARGER [ENGINE 1nCKET [LOADFACTOR | LOWGOOLAWT | ARSHUTOOWN JwGH FUEL | HIGH IGHT wrcirewe | FAULTWARWING| WareR EWP. | ATI00% TepeRavure | DAMPER eve EXHAUST GAS JACKET WATER | MARNEGEAR [oversreeD | AFTERCOOLER [LOW OL EPSSUPPLYING [OVERGRANK | HGHLEFT WaRwing | WARNING “een ‘OVERSPEED [ARNE GEAR — [GRanicaSE BACKUP Tow sare —[ Gevenavor —[OveRsree> Low ow Warwnc” | Ourmess.- [pressure |ectreaoy —|Voutace- | Powe PressUR Waren | SurToow AREY | wurerion —[arrencooten tow ou TEMOTE TAT [uicrearveny —Jovemunoen | RUPTURE festmcnow | oesiso — | Fewerarune | eves Siiroown ' [Wourace'"” (Wottage™” | SxSintEaK warning sHuTbown SmuST | ENGHEAT | ARSHUTOT | IGCOOLANT | AROAWPER [NEUTRAL [OVERVOLTAGE | ENGINE ‘Eatperxrure_ | Yoos nb Nevrenarone [loses Coren stor warning | FACTOR WARNING ‘OUFILTER | ENGINE SPEED PENGWENOTIN [ARMWEr ———[spaREFAULT | GROUND JUNDERVOLTAGE | UniTy Brresthna | ktovesonew | AUTO estat waen [SHUTDOWN | FAULT Power TUELATER | ENGINE TRANSMISSION | ENGNE DAG | EMERGENCY —[FIGHLOW Devenentia. | Overcrank |owteme | ACTVE S10° earrer’ ‘GRANACASE | STARTER MOTOR) TRANSISSION [OL PRESSURE | BAGNOSNE | LOW FUEL EVEL Templet pressure | tetavacine | ouewess. "| Wamwinc [aut av TAN warning swan Layout “AFTERCOOLER | SYSTEN WOT ENGINE DEBATE ENGINE TNOTE TOW FIELIEVEL Guide WARNING Area ENGINE OL ENGRE Sramrer | ENGNE PEaMaTe ‘oRCUT facrrew — | beeateo —ewonced —fuwninc Sto Breaker Waring chose. CATERPILLAR ALARM MODULES ANNUNCIATION CAPABILITIES Local with EMCP NFPA 99 EMCP I or Control Panel NFPA 110 con or cAM + Complete Flexibility Available ‘Alarm module and synchronizing module Alarm module and CAM CAM and synchronizing module Two CAMs + Up to 24 lights of local annunciation with 8 standard and up to 16 predefined or custom lights Remote Mounted (surface or flush mount box) NFPA 99 or NFPA 99 NFPA 110 oa or or CAM CAM Total of 16 LEDS Total of 6 LEDs + Remote Annunciator Flexibility Can be added in 8 or 16 light modules + Surface or flush mount box ALARM MODULES CATERPILLAR ALARM MODULE CUSTOM ALARM MODULE (CAM) CATERPILLAR’ ALARM MODULES EIGHT-LIGHT REMOTE MODULE. Materials and specifications are subject change without nate. “Tho ternational Systom of Units (i wsod inthis publication, Lesixe239 1© 1996 caerpitar ne Printed in US.A rights reserve

You might also like