Testing Laboratories TOSHIBA Toshiba Transmission & Distribution Systems (India) Private Limited TEST REPORT 7 Te 707 ULR No: TC782724100000705F : QA/I&T/U10/RTR/2024/05/004 Dated 02.05.2024 Page No 1 Of 22 Test Report No & Issue Dat Discipline & Product Group Electrical Testing & Inductors and Transformers Transformer Testing laboratory, Unit 10 Name, address and location ofthe test__| Toshiba Transmission & Distribution Systems (India) Private laboratory Rudraram (V), Patancheru (M), Sanga Reddy (D)-502329 Telangana, India Ph: 08455-69222 Fax: 08455-69245 TO00KVA, 11000/433V, 3 Phase Liquid Immersed, CRGO Core, Description of item(s) tested Aluminium Wound Distribution Transformer. Identification of the item(s) 5230142 To 5230151 (10Nos.) van - ‘ Mis. Wilson Power Solutions Ltd., U-K- Name and contact information of the | Tele Phone No: +44 (0)113 271 7588 P.O.No & Date: P 32078, Dated: 26/10/2022 $ ONo. 8323C IEC-60076 Part-I & IEC-60076 Part-3 , Method used for testing Refer page no.2 for List of tests. Condition of the transformer(s) New. Date of Sampling of test sample(s) Not applicable Date of receipt of the test item(s) 04.02.2023 To 08.02.2023. Date(s) Of Test(s) ~ | 04.02.2023 To 08.02.2023. Sampling plan and method Not applicable Customer requirements, if any ‘NIL Additions to, deviations, or exclusions NIL from the method, if any Test(s) subcontracted with NIL No. of pages 22 (Twenty Two Pages Only). PREPARED BY REVIEWED & APPROVED BY CH.NAGABHUSHANAM J z Engineer, QA (I&T) Asst. Manager, QA (I&T) ‘AUTHORISED SIGNATORY Note: 1, The test results relates only to the item(s) tested 2. The test report shall not be reproduced except in full, without the written consent of Quality Manager - Toshiba Transmission & Distribution Systems (India) Private Limited 3. The results reported in this report are valid at the time of and under the stipulated conditions of Measurements. 4, The laboratory is responsible for all the information provided in the report, except information provided by the customer ULR Ne: Te782726100000705F ‘Test Report No & Date: QAIBT/UIORTRI202405I008 Dsted 02 05.2024 TOSHIBA Toshiba Transmission & Distribution Systems (India) Private Limited Rudraram (V), Patancheru (M), ‘Sanga Reddy (0) 602 329 Telangana, India Ph: 08456.692222 Fax: 08455-602245 List of Tests Conducted S.No. |Name of the Tests Conducted 1 Measurement of Insulation Resistance: IEC 60076-1 Cl 11.1.4(h) 2 Measurement of Voltage Ratio: IEC 60076-1 Cl 11.3 3 ‘Measurement of Winding Resistance: IEC 60076-1 Cl 11.2 4 Measurement of No Load Loss & No Load Current: IEC 60076-1 Cl 11.5 ° Measurement of Short-Circuit impedance and Load Loss: IEC 60076-1 Cl 11.4 6 \Induced Voltage Withstand test: IEC 60076-3 Cl 11.2 7 [Applied Voltage test: IEC 60076-3 Cl 10 8 Vector Group Verification : IEC 60076-1 Cl 11.3 Car Page No of 22 ULR No: Torezr2sson000705 Test Repor No Date: OMETIUTONRTRIZ02405N004 Dated 02.05 2024 TOSHIBA Rudraram (V), Patancheru (M), ‘Sanga Reddy (0) 602 329 Telangana, India PPh: 08485-69222 Fax: 08455.692245 Toshiba Transmission & Distribution Systems (India) Private Limited \Tranformer SL.No 5230142 Rating 1000 kVA. Customer Mis. Wilson Power Solutions Ltd., U.K. Primary Voltage 11000 Volts Reterence Order po Noa Date P 32078, Dates 26/102022 Secondary Voltage ——409 Vals Sale OrderNo 02290 Primary Curent 52.496 Amps Hype oFcocting ONAN Secondary Curent 1228.4 Amps connection DetalStar Frequency so He Vector Group Dyntt Ret. Standard 5 ernest Haines Ont Wg +596 To - 5% ists of 2.5% Date Or rest o4.02.2028 |1.éeasurement of insulation Resistance Time HV - Earth (G Ohms) HV- LV (G Ohms) LV - Earth (G Ohms) 60 Sec 21.20 29.90 16.82 12. VOLTAGE RATIO TEST [Voltage Ratio with Actual Ratto rap wo] TBE activa | Murat | Waximumraio Ty Frese] v-Phase | W-Phase 1 | 50% 46.20 46.02 46.39 46.21 46.21 46.21 2 | 25% 45.10 44.92 45.28 45.11 45.11 45.11 3_ | Normal 44.00 43.82 44.18 44.00 44.00 44.00 4 | 25% 42.90 4273 43.07 42.90 4290 42.90 5 | 50% 41.80 4163 41.97 41.79 A179 4179 [s. WINDING RESISTANCE MEASUREMENT TEST Top Liquid Temp 28.8 °C H.V Winding resistance (Ohms) LV Winding resistance (mOhms) Tap No 1u-1V 1V-1W 1W-1U 2u-2n 2v-2n 2w-2n 3 0.6435 0.6468 0.6419 0.5889 0.8737 0.5608 HIV Winding Resistance per phase at 75 °C = 1.152 Q at Normal Tap LV Winding Resistance per phase at 75 °C 0.00068 © |4. NO LOAD LOSS & NO LOAD CURRENT MEASUREMENT TEST Measured / Calculated Values Guaranteed Values ‘Sage |coront | t2od |No-Load Loss ga) F68 No-Load Loss (He) |__| eurent [120% Rated votege | 433 | 1.0680| 0.0801 681 50.0 693 Watts (Max). Page No oF 22 UuR No: Terezr24so0000705F “ost Roper No & Ost: QAIETIVIURTRI2I245004 Dates 2.062024 Toshiba Transi ion & Distribution Systems (India) Private Limited TOSHIBA Rear (V, Patancher (M), Sanga Rey (0) 02 29, Telangana, nia Ze eh: nges 492052 rays Obs.60248 \Tranformer SL.No 5230142 Rating 1000 kVA 6. Loa Loss & mPEDANCE VOLTAGE MEASUREMENT TEST TopLiguistomp 256 0 Measured Values Calculated Values Guaranteed Values = [tea iessrea|icad toss atted] 9ar=t impedance | Coren | Tet \isateecorentaat7ec| rece | Load Loss % Impodance oo 0 lateo re taps] 52420 [52400] 5016 [ea200| 7411 | ar | 7600Watts (Max). | 475% -¥/-1EC Tol [p-AppLiep voLTace Test Voltage applied on HV. winding Keeping | Vollage applied on L.V. winding keeping FLV. LV. winging & body connacted fo earth for] winding & body connected to eath for 60 Remarks 60 seconds seconds 28 kV 3kV ‘Withstood [7. INDUCED VOLTAGE WITHSTAND TEST Voltage applied on L.V. winding at 150 Hz. keeping H.V. winding open for 40 seconds. Remarks 866 Volts Withstood VECTOR GROUP VERIFICATION TEST /ector group is tested and found to be Dyn-14 PREPARED BY REVIEWED & APPROVED BY CH.NAGABHUSHANAM G.SIDDAIAH Engineer, QA (IT) = Asst Manager, QA(&T) TOSHIBA-TTD! TOSHIBA-TTDI Page No 4 of 22 LR No: Tee2r24100000705F ‘Test Report Ne & Date aANaTIUTORTRI262405I004 Osted 0205-2004 Toshiba Transmission & TOSHIBA Rudraram (V), Patanchoru (M), ‘Sanga Reddy (D) -502 323 Ph: 08655-69222 Fax: 08455.692245 tribution Systems (India) Private Limited Telangana, India |Tranformer SL.No 5230143 Rating 1000 kVA Customer Ws. Wison Power Solitons Lid, UK Primary Voltage 11000 Vos Reference Order pono. Date P32078, Dated 261102022 Secondary Voltage 433 Vals Sale OrderNo — 8323C. Primary Current 52.486 Amps [Type Of Cooling ONAN Secondary Current 1333.4 Amps Connection Delta/Star Frequency 50 Hz Vecioreroup yn Ret stnders ——_‘(ECSONTE Pat 8 Pa [Tappings On HV Wdg + 5% To - 5% insteps of 2.5% Date Of Test 06.02.2023 }1.Measurement of insulation Resistance Time HV - Earth (G Ohms) HV - LV (G Ohms) LV - Earth (G Ohms) 60 Sec 19.30 31.10 19.60 b.voLtAce Rano rest Vato Rat with Aca Rate rap nol TEP8° Tactairaio | MMmUMaTO TMaximumra56 Ts Fase | v-Phase | W-Phase + | sox | #520 4602 4638 621 4622 w621 2 | 25% | 4510 wa92 1628 aan 1611 aa 3 [Nera | 4400 2a wa 7400 1400 4400 «| 25% | 280 a3 807 2.80 7290 #290 3 [0% [#180 a8 a97 a9 +80 78 b.wmon RESISTANCE MEASUREMENT TEST Tepumteny ma 0 H.V Winding resistance (Ohms) L.V Winding resistance (mOhms) Tap No wow | wew [wei | aan | av-an | aw-2n 3 oas2 | 06s | oes | ose | oars | osese FV Winding Resistance per phase at 75°C = 1159 Oat Normal Tap LV Winding Resistance per phase at 75 °C = 0.00068 Q J. No LOAD L085 & NOLOAD CURRENT MEASUREMENT TEST Measured /Galulated Values Guaranteed Values Taped [Rend] ene ve voltage | current | Load |No-Load Loss (W)| (Hz) No-Load Loss oo | “a | cer 100% Rated Voltage | 433 | 1.0908] 0.0818 689 50.00 f 693 Watts (Max)-—~ .) manson ‘ULR No. Tor827241 90000705 “eat Repor No & Ost: GAIBTIUTOIRTRI2024061004 Dated 02 052004 Toshiba Transmission & Distribution Systems (India) Private Limited TOSHIBA Rudraram (V), Patancheru (M), ‘Sanga Reddy (0) 502 329 Telangana, india ZS Ph; 08485-692222 Fax: 08455-69245 [Tranformer SL.No 5230143 Rating 1000 kVA. |s. LOAD LOSS & MPEDANCE VOLTAGE MEASUREMENT TEST Top Liquid Temp 258 °C Measured Values Calculated Values Guaranteed Values impedance [P0169 | p,q. |Measured|toad loss atrated] az at (epeianes | curent | F'0° |Lewsiowsfeurroma at 76°C | 76°08 | Load Loss. % impedance : “ w (ww __|atsoz Tap-3 | 519.70 | 52.520) 50.05 |6406.0] 7393 4.73 | 7600 Watts (Max). | 4.75 % #/- IEC Tol |e. APPLIED VOLTAGE TEST Voltage applied on HV. winding Keeping Voltage applied on LV. winding keeping FLV. LV. winding & body connected to earth for} winding & body connected to earth for 60 Remarks 60 seconds seconds, 28 kV 3 kV Withstood V7. INDUCED VOLTAGE WITHSTAND TEST Voltage applied on L.V. winding at 150 Hz. keeping H.V. winding open for 40 seconds, Remarks 866 Volts Withstood [b. VECTOR GROUP VERIFICATION TEST /ector group is tested and found to be Dyn-14 PREPARED B} REVIEWED & APPROVED BY CH.NAGABHUSHANAM GSIDDAIAH Engineer, QA (I&T) ‘Asst Manager, QA(I&T) TOSHIBA-TTDI TOSHIBA-TTDI PageNe 8 0F 22 LR No: Ta7ear24ra0000705F Test Ropar No & One: GATBTIUORTRI20240SI004 Dated 02.05 2004 Tos 1a Transmission & Distribution Systems (India) Private Limited TOSHIBA Rudraram (V), Patancheru (M), ‘Sanga Reddy (0) -502 329 Telangana, India Ph: 08455-69222 Fax: 08465-692245 ‘Tranformer SL.No 5230144 Rating 1000 kVA Customer Ms. Wiison Power Solutions Ltd, U.K. Primary Voltage 11000 Volts Reference Order po No. Date: P 22078, Dated: 26102022 Secondary Voltage «433 Vols Sale OrderNo 8929¢ Primary Current 52.486 Amps Type Of Cooling ONAN Secondary Current 1333.4 Amps Iconnection _Detta'Star Frequency 50 He Vector Group Dynt4 Ref. Standard iEc-e0076 (Part-1 & Part |Tappings On HV Wdg + 5% To - 5% insteps of 2.5% Date Of Test 06.02.2023 |{ Measurement of Insulation Resistance Time HV - Earth (G Onms) HV -LV (G Ohms) LV - Earth (G Ohms) 60 Sec 18.38 29.40 19.10 fz woutase Ramo Test tage Rati with Acta Ratio rap Neo] T9BB° Tactuat ato | MTIMUM rat [Maximum al 1 phase | v-Phase | W-Phase 1 | 50% | 4620 46.02 46.39 21 oa 2621 2 | 25% | asa0 “ae 45.28 aaa en an 3 | Nomar | 4400 6a ae 00 700 “01 + | 25% | 290 2273 607 #290 200 290 5s | 0% | neo a8 a7 a8 “79 “79 . WINONG RESISTANCE MEASUREMENT TEST TeptieiéTonp 288 °C H.V Winding resistance (Ohms) L.V Winding resistance (mOhms) Tap No wv [awe | aww | ava | avan | aw-2n 3 ossoe | ones | ose | ose | 0580: 08716 HV Winding Resistance per phase at 75 °C LV Winding Resistance per phase at 75 °C = 0.00070 0 1.159 Q at Normal Tap |4. NO LOAD LOSS & NO LOAD CURRENT MEASUREMENT TEST Measured / Calculated Values Guaranteed Values Tepe | No-oad] Yen Cote | eorat | oad |NoLond Lose m8 No-Load Loss ™) {A)_| current oe) 100% Rated Voltage | 433 | 1.0665] 0.0800 688 50.0 693 Watts (ua - Pege No Of 22 LULA Ne: To7az7241o0000705 Tos esos No ste QMITURTRDIZENSO Oa 2 5 250 Toshiba Transmission & Distribution Systems (India) Private Limited TOSHIBA Ruararam (),Patancher Sanga Reddy (0) 302 929 Tlangana, nia rons S022 ans OB45-602245 |Tranformer SL.No 5230144 Rating 1000 kVA 5. LOAD LOSS & IMPEDANCE VOLTAGE MEASUREMENT TEST Toplinidtenp 388 °C Measured Values Calculated Values Guaranteed Values Trmodanoe |*P167] oq esarc|load oes arated] zat Angatonce | ren | 08 lloavuss| euro & atc | 708 | Load Loss % impedance (A) wm ™) jat 50 Hz taps] sia67 [52.400] 50.10 Jeeaso] ras | 73 | 7600 Watts (Max). | 4.75% +/-IEC Tol J. APPLIED VOLTAGE TEST ‘atageapsfed on HV. wining Keping- | Votago ppvet on LV wir Keeping HV Living & os connected earn f| mg body comet see 6D Remarks eo secon seam 28 KV 3 Kv Withstood f.MDUCED VOLTAGE WITHSTAND TEST Vottage applied on LV. winding at 150 Ha. keeping H.V. winding open for 40 seconds Remarks 866 Vots Withstood VECTOR GROUP VERIFICATION TEST actor grou is tested and found o be Dyn-tt PREPARED BY REVIEWED & APPROVED BY CHNAGABHUSHANAM @SIDDAIA Engineer, QA (I&T) Asst Manager, QA(I&T) TOSHIBA-TTDI TOSHIBA-TTOI Page Now or 22 Tost Report No & Date: QANETIUIURTRI2O2NDEN4 Osted 0205-2024 ssion & Distribution Systems (India) Private Limited | [Tappings On HV Wag + 5 % To - 5% insteps of 2.5% Date Of Test TOSHIBA Rudraram (V), Patancheru (M), « ‘Sanga Reddy (0) -602 329 ae Telangana, india aos Ph: 08455-692222 Fax: 08455.692245 a [Tranformer SL.No 5230145 Rating 1000 kVA ‘Customer Mis. Wilson Power Solutions Ltd., UK. Primary Voltage 11000 Volts Reference Order No & Date: P.0NO& Date: P 32078, Dated: 26/10/2022 Secondary Voltage 433 Volts [Sale Order No 8323C Primary Current 52.486 Amps [Type Of Cooling ONAN Secondary Current 1333.4 Amps |Connection Delta/Star Frequency 50 Hz lvector Group Dyn? Ref. Standard IEC-60076 (Part-1 & Part 3) 06.02.2023 |1.Measurement of insulation Resistance Time HV - Earth (G Ohms) HV -LV(G Ohms) LV - Earth (G Ohms) e0See 7500 2680 2070 b.voLTAGe nano Test ate Ret wih Acta ati rap ne] T3PBP9° Tactuatraio | MTImumate [M@uTIM ICT phage | v-Phase | _W- Phase + | s0% | 4020 4602 4699 “21 wi “eat 2 | 25% | «0 um 1578 aan an aan 2 [Nema [4400 ae 1418 4401 aaa a0; «| 25% | 230 a7 a7 22.89 “289 72.80 3 | 0% | «130 H188 maT #80 HA a7 |3. WINDING RESISTANCE MEASUREMENT TEST z Top Liquid Temp = 26.5 °C H.V Winding resistance (Ohms) L.V Winding resistance (mOhms) Tep No we | ww | awe | auan | aan | aw-tn 3 osass | oem | oes | ose2a | ocaze | ososo AV Winding Resistance per hase at 75 C= 1156 0 at Normal Tap LV Winding Resistance per phase at 75 °C = 0.00069 Q kno LOAD 08s & NO LoAo Gurren MEASUREMENT TEST Measured / Calculated Values Guaranteed Values Stoo caren | Land |No-Load Loss ca] F8 No-Load Loss ™ 1A)_| current (Ha) 100% Rated Votage | 433 | 1.1476] 0.0861 687 50.0 Al 693 Watts (Max Page Nov of 22 y i oe ULR No: Tea2r2esoon90705F ‘Test Report No & Date QANBT/UTORTRI2024/08004 Dated 2 05.2004 Toshiba Transmission & Rudraram (V), Patancheru (M™), ‘Sanga Reddy (0) -502 329 Telangana, India Ph: 08465-69222 Fax: 08455.692245 TOSHIBA istribution Systems (India) Private ited (eS) [Tranformer SL.No 5230145 Rating 1000 kVA, '5. LOAD LOSS & IMPEDANCE VOLTAGE MEASUREMENT TEST Top Ligud Temp 268 °C Measured Values Calculated Values Guaranteed Values impedance [*?PIC3 | jgq_ Messure|Load loss at rated] zat Votage (vp | Stent | fuipy [boas loss| eurrent& at 76°C | 75°C & Load Loss ‘% Impedance “ wo, wy latsonz Tap-3| 519.68 |52.480/ 50.03 |64720) 7472, | 4.74 | 7600 Watts (Max). | 4.75% +/-IEC Tol. |e. APPLIED VoLTAGE TEST Voliage applied on HV. winding keeping | Voltage applied on L.V_ winding keeping A.V. LV. winding & body connected to earth for] winding & body connected to earth for 60 Remarks 60 seconds seconds 28 kV 3k ‘Withstood i7-INDUCED VOLTAGE WITHSTAND TEST Voltage applied on L.V. winding at 150 Hz, keeping H.V. winding open for 40 seconds. Remarks 866 Volts, Withstood [8. VECTOR GROUP VERIFICATION TEST /ector group is tested and found to be Dyn-14 PREPARED BY REVIEWED OVED BY CH.NAGABHUS! ANAM G.SIDDAIAH Engineer, QA (I&T) Asst Manager, QA(I&T) TOSHIBA-TTDI TOSHIBA-TTDI Page No 10 0F 22 LR No: Tovearessono00705F Test ReportNe & Date QANETAJTORTRIZ02405I004 Dated U2 05,2004 Toshiba Transmission & Distribution Systems (India) Private Limited & (SS) TOSHIBA Rudraram (V), Patanchoru(M), ‘Sanga Reddy (0) 602 329 = Telangana, india S13 Ph: 08455-692222 Fax: 08455-69245 [Tranformer SL.No 5230146 Rating 1000 kVA, Icustomer Mis. Wilson Power Solutions Ltd., UK Primary Voltage 11000 Volts Reference Order he eae P.O.No & Date: P 32078, Dated: 26/10/2022 Secondary Voltage 433 Volts [Sale Order No 83230 Primary Current 52.486 Amps ‘Type Of Cooling ONAN Secondary Current 1333.4 Amps [Connection _—_Delta/Star Frequency 50 Hz Vector Group Dynt1 Ref. Standard 30 00078 Pant & Pant [Tappings On HV Wig + 5 % To ~5% insteps of 2.5% Date Of Test 07.02.2023 |1.Measurement of insulation Resistance HV-=Lv (6 Ohms) _ Time HY Earth (G Ohms) Ly - Earth (6 Ohms) 60 See W724 2770 240 (2. VOLTAGE RATIO TEST FE ie Voge Rato with Atul Ratio Tap no] T2PB9° Tactutrato | Mmmum alo TMaxinumrato [brace | y-phase | W-Phase 7 | 0% | 4620 46.02 46.39 1621 4621 62 2 | 20% | 4510 or 4528 “i aan att 3_| Nomar | 4400 ae 48 44.00 4400 44,00 «| 25% | «200 an 7307 208 289 2289 5 5.0% 41.80 41.63 41.97 41.79 4179 41.79 [ WINDING RESISTANCE MEASUREMENT TEST TeptimisTenp 24°C HV Winding resistance (Ohms) LV Winding resistance (Ohms) Tap No wv | weaw | aww | aun bv-2n Bw =n 3 cc 0.5656 HV Winding Resistance per phase at 75 °C 1.14 Q at Normal Tap LV Winding Resistance per phase at 75 °C = 0.00069 Q hk. NO LOAD LOSS & NO LOAD GURRENT MEASUREMENT TEST Measured / Calculated Values Guarantead Values Fd Nona] % No res voto | soren | tas |No-LoadLoss 8 No-Load Loss wr | “ta | coro 00% rates votace | 499 |1.1125[00804) 62a | soo 699 watts per Ae LR No: Torazr24ro000705F Test Report No & Date: OAIBTIUTORTRI2O2U08006 Dates 02.05.2024 Toshiba Transmission & Distribution Systems (India) Private Limited TOSHIBA Rudraram (V), Patancheru (M), Sanga Reddy (0) 602 328 Telangans, Ind Ph: 08455:692222 Fax: 08486-652245 \Tranformer SL.No 5230146 Rating 1000 kVA [LOAD LOSS & MPEDANCE VOLTAGE MEASUREMENT TEST ToptiadsTemp 281°C Measured Values Calculated Values Guaranteed Values impedance [*P2°9] freq [Moasucaltoed toss at ated] saz at Tepes [curent | [ee ltoceiss|curents at75°c | 75c&| Load Loss % Impedance a A i) wy) at 50 Hz Tap-3| 523.67 |52.490] 50.01 64550 7417 | 4.77 | 7600Watts (Max). | 4.75% +/-IEC Tol. |s APPLIED VOLTAGE TEST Voltage applied on HV. winding Keeping | Voltage applied on L V_ winding keeping FLV. L.V. winding & body connected to earth for! winding & body connected to earth for 60, Remarks 60 seconds seconds 28 KV 3k Withstood [7- INDUCED VOLTAGE WITHSTAND TEST Voltage applied on L.V. winding at 150 Hz. keeping H.V. winding open for 40 seconds. Remarks 866 Volts Withstood [8. VECTOR GROUP VERIFICATION TEST /ector group is tested and found to be Dyn-14 PREPARED BY REVIEWED & APPROVED. CH.NAGABHUSHANAM. G.SIDDAIAH Engineer, QA (IT) ‘Asst Manager, QA(I&T) TOSHIBA-TTDI TOSHIBA-TTDI Page No 1208 22 LR No: Torezr2et00000705F Test Report No & Date: QANETIUIORTR,2024I051004 Dated 02062024 Toshiba Transmission & Distribution Systems (India) Private Limited TOSHIBA Rudraram (V), Patancheru (M), Sanga Reddy (0) -802 329 Telangana, india Ph; 08455-s90082 Pax: 08456-602245 ITranformer SL.No 5230147 Rating 1000 kVA Icustomer Mis, Wilson Power Solutions Ltd, U.K. Primary Voltage 11000 Volts Reference Order beri P.ONo & Date: P 32078, Dated: 26/10/2022 Secondary Voltage 433 Volts [Sale Order No 83230 Primary Current 62,486 Amps ‘Type Of Cooling ONAN Secondary Current 1333.4 Amps [Connection _—_DeltavStar Frequency 50 Hz Vector Group Dyn 11 Ref. Standard Bn Pare & Part lTappings On HV Wag + 5 % To - 5% insteps of 2.5% Date Of Test 07.02.2023 |1.Measurement of insulation Resistance Time HV - Earth (G Ohms) HV- LV (6 Ohms) LV - Earth (G Ohms) 60 See 24.00 35.20 16.82 Iz voLTAGe RATIO TEST Vottage Ratio with Actual Ratio Hrap No] T@°P!°95 Tactuat ratio | Minimum ratio | Maximum ratio | 1 phase V-Phase W-Phase % value value 1 | 50% 46.20 46.02 46.39 4621 46.21 4624 2 | 25% 45.10 44.92 45.28 461 45.11 45.11 3_| Nomat | 4400 43.82 4448 4400 4401 4400 4 | 25% 42.80 278 43.07 42.90 42.80 42.90 s | 50% 41.80 41.63 4197 4179 4478 4178 I. WINDING RESISTANCE MEASUREMENT TEST TepLigudTemp 281°C H.V Winding resistance (Ohms) LV Winding resistance (mOhms) Tap No tu-1V 1v-1W 1W-1U 2u-2n 2v-2n 2w-2n 3 06483 0.6486 0.6482 0.5894 05722 0.5686 HV Winding Resistance per phase at 75 °C = 1.15 @ at Normal Tap LV Winging Resistance per phase at 75 °C = 0.00068 © Js. NO LOAD LOSS & NO LOAD CURRENT MEASUREMENT TEST Measured / Calculated Values Guaranteed Values, ‘Applied [No-Load] % No- ; volage | curent] toad |No-Load Loss wn} 2 No-Load Loss ™ (A)_| current 00% Rates Votage | 433 |1.0736|0.0805| 679 50.0 698 Wath (Max). Je LR No: Tvazr241o0000705F ‘est Report No & Oat: AAIRTIUIORTRIZOZADS004 Osted 2 05.2004 Toshiba Transmission & ibution Systems (India) Private Limited hi TOSHIBA Rudraram (V), Patancheru(M), (SS) Sanga Reddy (0) 502 328 = Telangana, india ZS Ph: 08465.682222 Fax: 08455-692245 \Tranformer SL.No 5230147 Rating 1000 kVA 5-LOAD LOSS & MPEDANCE VOLTAGE MEASUREMENT TEST TeptiausTonp 201 °c Measured Values Calculated Values Guaranteed Values impedance [P69 | oq MesucdLoad os arated) zat trpedance Vent | 100 longs fourrenta at76°C| 76-08 | Load Loss % impedance "se (A) wy (w) at 50 Hz Tap-3 | 516.97 [52.490] 49.95 |6410.0 ‘7374 472 7600 Watts (Max). 4.75 % +I- IEC Tol. |e. APPLIED VOLTAGE TEST Voltage applied on HV. winding keoping | Voltage applied on LV. winding keeping FLV. L.v.winding & body connected to earth for] winding & bedy connected to earth for 60 Remarks 60 seconds seconds 28 kV BkV Withstood [7. INDUCED VOLTAGE WITHSTAND TEST Voltage applied on L.V. winding at 150 Hz. keeping H.V. winding open for 40 seconds. Remarks 866 Volts, Withstood [8. VECTOR GROUP VERIFICATION TEST jector group is tested and found to be Dyn-14 PREPARED BY REVIEWED & APPROVED BY CH.NAGABHUSHANAM G.SIDDAIAH Engineer, QA (I&T) Asst Manager, QA(I&T) TOSHIBA-TTDI TOSHIBA-TTDI Page No 16 of 22 LR No: Toranr2stonnne7as6 Tost Report No & Date: GANET/UIORTRI2624N5I004 Dated 02.05.2004 | Toshiba Transmission & TOSHIBA ribution Rudraram (V), Patancheru (M), ‘Sanga Reddy (D) -502 329 Tolangana, Ph: 08485-69222 Fax: 08455602245 ‘Systems (India) Private Limited India ITranformer SL.No 5230148 Rating 1000 kVA. Icustomer Mis, Wi'son Power Solutions Lid, U.K Primary Voltage 11000 Volts Reference Order Neg Dates P.O.No& Date: P 32078, Dated: 26/10/2022 Secondary Voltage 433 Volts [Sale Order No 83230 Primary Current 52.486 Amps IType Of Cooling ONAN Secondary Current 1333.4 Amps Connection _Delta/Star Frequency 50 Hz lVector Group Dyn tt Ref. Standard oe Pant & Par lrappings OnHV Wag +5 % To - 5% insteps of 2.5% Date Of Test 07.02.2023 |1.Measurement of Insulation Resistance Time HV-- Earth (G Ohms) HV- LV (G Onms) LV - Earth (G Ohms) 60 Sec 7277 79.60 7014 lz. VOLTAGE RATIO TEST a i ; [Votage Ratio with Actual Ratio anno] TBO [aualano | Mum ale [WOAMUTaWO Ty. phase | v-Prave | _W:Phave 1 | 50% 46.20 46.02 46.39 46.21 46.21 46.27 2 | 28% 45.10 44.92 45.28 45.11 45.11 45.11 3 | Normal | 44.00 43.82 44.18 44.00 44.00 44,00 4 | 25% 42.90 42.73 4307 42.90 42.90 42.90 5 | 50% 41.80 41.63 4197 4179 an78 4179 Js. WINDING RESISTANCE MEASUREMENT TEST Toplimud Temp 281°C H.V Winding resistance (Ohms) LV Winding resistance (mOhms) Tap No qu-1v 1v-aw 1w-1U 2u-2n 2v-2n 2w-2n 3 0.6427 0.6431 oat 0.5980 0.5842 0.5638 HIV Winding Resistance per phase at 75 °C = 1.14 Q at Normal Tap LV Winding Resistance per phase at 75°C 0.00069 0 /s. NO LOAD LOSS & NO LOAD CURRENT MEASUREMENT TEST Measured / Calculated Values Guaranteed Values ‘elage | curent | Load |Nodosd oss cw] Fe No-Load Loss te) |). | caton 100% Rates votage | 433 |1.0882]0.0816] 674 50.0 693 Watts (Man. Page No 15 0F € ARE ULR No: Te782r24s0000070 oF Test Report No & Date GALIETIUTOARTRIZ024/05I004 Dated G2 052004 Toshiba Transmission & Distribution Systems (India) Private Limited TOSHIBA Rudraram (V), Patancheru (M), « ‘Sanga Reddy (0) -602 329 Telangana, india na Ph; 08455.692232 Fax: 08456.602245 |Tranformer SL.No 5230148 Rating 1000 kVA [5. LOAD LOSS & IMPEDANCE VOLTAGE MEASUREMENT TEST TopUguidTemp 201. °C Moasured Values Calculated Values Guaranteed Values ‘plied Wwcasuciiaad oss atratea] zat trpedance Pciren' | (00 londiss|eurenta at76°C| rece | Load Loss % Impedance st A) i] m at 50 Hz Tap-3| 517.87 |52510| 49.99 |6426.0 7384 4.72 7600 Watts (Max). 4.75 % +I-1EC Tol. |e. APPLIED VOLTAGE TEST Voltage applied on HV. winding Keeping | Voltage applied on LV. winding Keeping HLV, LV. winding & body connected to earth for} winding & body connected to earth for 60 Remarks 60 seconds seconds 28 kV 3kV Withstood [7-INDUCED VOLTAGE WITHSTAND TEST Voltage applied on L.V. winding at 150 Hz. keeping H.V. winding open for 40 seconds. Remarks 866 Volts Withstood |B. VECTOR GROUP VERIFICATION TEST /ector group is tested and found to be Dyn-14 PREPARED BY REVIEWED § APPROVED BY CH.NAGABHUSHANAM GSIDDAIAH Engineer, QA (I&T) Asst Manager, QA(I&T) TOSHIBA-TTDI TOSHIBA-TTDI Page No 16 0F 22

You might also like