+ GENERAL
101 Te
1.02 Operating Temp. Lint
103 Oferaing Press Lint
1 06 compe asset
108 Sar seven see
106 teureng
1.07 Wet
4108 Ob
2 BODY
203 Noreen
204 Process corn, swe
205 Presue ata
206 Faceto eve denon
207 Bornttype
208 meta Soy bonnet
2-11 Moi Doksrts
212 Poet como
219 Ober
2 TRIM
01 Type
304 Sion tae
308 Seatiatage class
208 Fw cot eae a)
5.1 Meta sr raueg eat)
212 Meta cape
313 Mat sor
244 Hardee
1o00 weg)
Nore 12
24 vonr
By ronda
ine redo 6 vendor
byron
yen
4 vente
egal lane
am
IeAgrsoa0t
By vans
Digs 226.1
ay ver
yes
ANgS Gr BT /AI96 Ge. 24
x vente
fount Percent (186)
2p vontr
(asst (ranemun)
Byvenda
By vendor
2y vans:
agiess 27%
rapes 274 cr
yvonr
Dagon 88 22%
xo
4 HYDRAULIC/PNEUMATIC ACTUATOR
401 Sipoy metus
|402 Sip free mevnominan
4403 Correction sutyroun
1404 Daphooripstn see
4105 Motos, dephcarpton
5 ELECTRICAL ACTUATOR
501 Cabe arn egal
52 Cable erty sgnalponer
5 ences petacion
S04 Ec ceteaton
50 te sional
Ce Supp) vatagetiageney
507 Conmnpton
mom ee)
went
By vend
Na
Na
Na
ACTUATOR (GENERAL)
801 Tips
{805 Dirensionsoe
{806 Gorrecton acuaertoy
807 Gon acta stom
08 Quek crest
1819 Met cath
14 Meta sping
16 Mooi, Dota
2.16 Potetne coins
1 POSITIONER
ro pe
702 Mentacer wera
703 Mertaconer|
7.04 Meo, house
708 Prete costing
7.0 Oaput ai
70 tputinpedance
1 cate ty
710 Enesuepoeton
711 Ec catenin
712 puta
114 Bypase
78 Supiyprecere
171 Sippy orecten ntype
7 Gage
718 Ober
2 MISCELLANEOUS
fot ive eee
2.07 Fier ear
08 Viner
‘9 PROCESS CONDITIONS
201 Temperate
‘302 Inet resire
200 Outlet Presa
208 Li Fw Rat
1205 Ges i Rate
208 Vicon
son sew
18.09 Flan Coat
231 Presa Drop
1832 cheep
845 hove
wae)
rae)
toh
toh
wae)
ow
syne
Lures Ofer
‘yvencor
‘ysencor
By vero:
‘ate
ates
ry
Dipiecss 22% cr
bapiecss 22% cr
Byvenior
Nel atees
ir
‘ay vendor
By vendor
‘Aun
By vendor
Pas
Ela
4°20ma HART)
pve Bye
pve ove
pve by veeGENERAL NOTES:
41-All Contial Valves shall be stable for area cassiied as indicated inthe dala sheet. Contol valves shell meet the
INMETRO ordinance 179 of 100512010 marke and present and certficates required. Exia for fied postioner shall be
‘provided,
2 -AllConttol Valves shall be delivered with two identification plates. One tag plats and one name plate in 316SS according
{oitom @ of TR2212.
3 Supplier shall define the appropriate diameter. Calculation sheet must be incded in the proposal
4 Every electic or electronic component subject to fungus or salt humidity shal be topicalized, which means to be coated
‘wih povyurethane cr equivalent. in crder to inibt these agents.
‘5 Pressure gauges supplied along with fiters and elecropneumatc pesitoners shall have their casing in 3168S or in
themmofix pheroic polymeric. Movement and incicator shall also be in 3168S. The connections materal shal be in
31088.
66 The electronneumatic postioner snail be smar type. 4420 mA wih HART protocd, alphanumenc display, power SUDPAY of
24.Vec, wo wites, weather and explosion proot
7 - Pressure regulator with fiter gages and electro preuratic positioner skal be supplied already installed inthe valve, with
pneumatic compression fitings ans tubing in siairtess steel 3768S. The tubing walls mus! be 6.35mm (1/4") OD x 0.88mm
(0.035) thick,
8 items shall be supped as speotted by the individual data sheets. Allens shal be sultable for @ humid sat laden
‘environment.
8 -AllContiol Valves shall be according o TR-0088, iter 6 of TR-2092 and TR-2212.
10.- Several applications require calculations as represented in the conte valves specification sheet Each contral valve
having several sizing cases shall be evaluated by the Vander and recommendations submited regarding metfication,
‘any, fr all cases,
11--Allelectrical cables entries shal be threaded M20 x 1,5 mm.
12 - All actuatorto-valve mounting brackeis shal be designed wih sufficient stengih to support tne actuator.
‘whatever the mounting positen
13 - Materials shall be in compliance wih NACE NIRO17S.
14 All requirements in these data sheet shall be according TR 2000 Spec (attachment)
15 - Material balance documents
PE-WF-30-8-MB-00002-001 - Heat mass balance (Phase I case 1)
PE-WF-30-8.MIB-00003-001 - Heat mass balance (Phase Il case 2)
16-ALT 4 case refere to Burner init at 2.7 bar(g). ALT 2 case refers to Burner inlet at 36 ber(g) Reference:
PE-WF-33-5-CA-20301-001.
17 Inform valve ‘ature open flowrate fo:
32.PV.301 142 @ 360 kPa(g) backpressure
22:PV-901 182 @ 260 kPa(g) backpressure
38-PV-9041A2 @ 80 KPalg) backpressure
8S-PV-904 102 @ £0 KPalg) backpressure
18 - Valve sizing calcuations shall be according 10 IEC 60534-2, ISA 75.01 or similar.
10.-Valves shat be cerifid for Zone 1, Gas Group IB, T3 as mrimum,
20 Al fitorregulatore chal be provided wth an integral roliaf valve and micron fiter.to BY ELEC. es &
iO Oo} pk INSTRUMENT
eo IK
BILL OF MATERIAL FOR ONE INSTALLATION
(TEM | QTY DESCRIPTION
2425 1_|1/2” FNPT 2-WAY BALL VA, 2200#, 316SS SWAGELOK No. SS-63-TF8
4101 | 20° |1/2” PIPE, SCH 40S, SEAMLESS, 316SS, PLAIN END
4251 1 1/2” FNPT HEX COUPLING, 316SS, TBE
so43 | 1 [1/2” TUBE x 1/2” NPT MALE CONN., 316L SS
so44 | 1 [1/2” TUBE x 1/4” NPT MALE CONN., 316L SS
$687 | 20’ |1/2” 0.0. x .065” WALL TUBING, 316L SS, SEAMLESS