Health & Safety File
Health and Safety File
Education City Stadium Project
1, Residual Hazards
2. Hazardous Materials
Prepared for: Supreme Committee for Delivery & Legacy
Document Reference number: SC-CO5S-CAG-JPQ-HSF-AD-00003 Rev.00
Prepared by:
JPACIV
P.O. BOX 12729 - DOHA ~ STATE OF QATAR
Tel: +974-44675429, FAX: +974-44675433
E-mail: jandpdoh@[Link]
Please note!
UNCONTROLLED VERSION WHEN PRINTED OR SAVED LOCALLY
Refer to the Controlled Document in PM Portal for the latest version. Any suggestions/feedback on this document are to be emailed to gf stadium
@[Link]
Document Reference number: SC-CDS-CAG-IPQ:HSE-AD-00003 Rev.00
Page 1of8o€ >tiwi
tae #&STAD
Approval sheet
Document owner: Kypros Charitou, Project Director
Signature:
‘This document forms part of the Project Handover Record Inforjfatlon, and it will form part of the Final Project handover
document.
Revision history
Revision Date ‘Additions/modifcations
00 14/06/2020 This document isa live document
| Tile Signature Date
Prepared by Noble Ikpa Sr. HSE Officer \ se) s4/08s2020
Ihave prepared this document * ayers
having identified SC requirements. oy
Reviewed by |Adeshina Nurudeen H&S Manager 14/06/2020
| have prepared this document
having identified SC requirements.
Checked by Chris Christou MEP Engineering 14/06/2020
Ihave prepared this document | Manager
having identified SC requirements.
“Checked by Mary Sgouropoulow | cvilEngineer 14/06/2020
I have prepared this document
having identified SC requirements.
Document Reference number: SC-C0S-CAG-JPQ:HSF-AD-00003 Rev.00
Page 2of8 esKs
TETRA
NBN
Qos
UPS
wae
WLAN
Terrestrial Trunked Radio
Qatar National Broadband Company
Quality of Service
Uninterruptible Power Supply
Wireless Access Point
Wireless Local Area Network
Document Reference number: SC-COS-CAG-IPQ-HSF-AD-00003 Rev.00
Page 8of8Residual Hazards
‘The following table outlines the residual hazards which remain from the project works and how they have been dealt
with: (it will be filtered later as the design and the construction are moving ahead, and the final register will be sent part
of the final handover project document.
Hazard | Significant Residual Health and Safety References
Number Hazard, Recommendation/Remarks.
Tobe managed bythe
contactor in ecordonee with
the packoge.
ECS-01- | Flooding at the ‘© Prevent all residues and wastes Please Refer to the MST
001 lower level and the generated by concrete works from for AC Unit installation.
Basement. entering the storm-water system.
© Minimize the amount of waste SC-CO5-CAG-IPQ-MST-DR-
entering the storm-water system. | 00080 Rev.03
‘* Maintain and keep the pressurised
pipe wet systems free from
| damages and leakages.
‘* Monitoring the water quality using
BMS (Building monitoring system).
ECS-01- | Hot water © Unbalanced hydraulics resulted in| Please Refer to Testing
002 Circulation pump ‘temperature losses and increased and Commissioning of Hot
spillage at the Legionella risk. Water System.
* Secondary recirculation pumps can
lead to local flow inversions soit | SC-C05-CAG-JPQ-MST-PL-
3 should be constantly checked. 00229- REV-02.
project. * An investigative approach is
proposed to improve hot water
system hydraulics. - a
ECS-01- Drainage System in |» The drainage workers are at areal _ Please Refer to the MST
003 all the level which risk of being exposed to gases of like for installation & Testing,
emits poisonous Ammonia, Hydrogen sulphide, of HDPE Pipes and Fittings
sewer gases like Methane, Carbon monoxide, for Pressurised Drainage
HS. Sulphur dioxide. .
‘© The gas level should be tested System above Ground. SC-
before the maintenance work C0S-CAG-JPQ-MST-DR-
commence. 00098 - REV 1.
basement and all
areas of the stadiumECS-01-
004
ECS-01-
005
ECS-01-
006
ECS-01-
007
Bacteriological
spread from the
Circulating Pumps
Submersible,
Sewage, condensate,
Pit Sump & Surface
Over flow and
environmental
pollution.
Chlorine Oxide
system
contamination.
Water heater
chamber at the
basement. Severe
burns from scalding
water, electric shock
hazards, explosions,
and fire.
Estal arobust maintenance
programmed for the AHU units: All
mechanical and electrical
equipment needs regular proper
maintenance.
Have the AHU’s service by a
professional as per the period
specified by the design authority
This depends on the level of
contamination from dust, mould,
bacteria, insects and rodents.
Ensure that the sewage line is
constantly monitored to ensure that
the condensations are been
evacuated on regular bases.
The maintenance manual be
referred to as a guild for the change
s that will be made during this time.
Drain and flush the system as
advised by the design manual to
prevent the build-up of sediment,
All the installation should be
properly grounded with the correct
gauge of the copper wire.
Because most water heaters reside
in closets of the stadium, basements |
and garages, and are for the most
part hidden from our daily lives,
many aren’t as aware as they should
be of the maintenance and
precautions which are necessary for
safety.
Please Refer to the MST
for Method Statement for
Testing and
Commissioning of Air
Handling Units (AHU)
‘SC-CO5-CAG-JPQ-MST-ME-
00155 Rev 01.
Please Refer to the MST
for Method Statement for
Testing and
Commissioning of
Submersible Foul & Storm
Drainage Pumps.
SC-CO5-CAG-JPQ-MST-ME-
00169 REV 01
Please Refer to the MST
Method Statement for
Installation of Ground
Water Drainage.
‘SC-CO5-CAG-JPQ-MST-ME-
00029 Rev 02
Please Refer to the MST
for Testing and
Commissioning of Low
Capacity Electric
Immersion Water Heaters
(Stand Alone)
SC-CO5-CAG-JPQ-MST-PL-
00201 RevoECS-01-
008
ECS-01-
009
ECS-01-
010
‘Turf pitch,
Environmental
pollution. Inhalation
hazard.
Fall from height
Access/Egress to the
roof.
| Gantry hand rail
gaps,
Pitch cooling system should be Please Refer to the MST
closed during the fertilization and for Method Statement for
fumigation activities of the pitch Fertilization and
area. ‘eanil inflow of Maintenance of Turt
Proper cleaning to avoid inflow of cory — prea 1 & A.
contaminated water into the
drainage system. SC-CO5-CAG-JPQ-MST-PH-
00275 REV 01.
Ensure that all the safety measures | Ref. Chapter 8 of the
are duly followed and Referto the —_ Health & Safety file.
manual for cleaning of the stadium
and the use of full body harness well
anchored, to avoid the fall from
height.
‘Always ensure that the proper Ref. Chapter 8 of the
design to bridge the joint gap of the Health & Safety file.
gantry hand rail is in place.
Strictly follow the safety file
document when accessing the
gantry.Hazardous Materials
All Control of Substances Hazardous to Health (COSHH) assessments and Material Safety Data Sheets (MSDS) are
to be provided.
‘The hazardous materials that are considered applicable to the works on the ECS project and which form part of the
final fabric of the Stadium building are included in the Control of Substances Hazardous to Health (COSHH) register.
Further details for the materials, MDS and detailed COSHH assessments, please refer to the Operation and
Maintenance Manuals, which will be submitted part of the final project handover document of the ECS Stadium
Project,
The following table outlines the hazardous materials used with the construction of this building and the necessary
‘measures that need to be taken for the safe maintenance and/or removal:
Serial] Material | Level Location Hazard Control
No. measure and
location of
| _ information
[01 | Epoxy Floor | Storedat | Floors © Causes serious eye irritation. IRefer to Safety
coating the evel 2 ata Sheets in
of the © Causes skin irritation. (AS-AR-O0266
stadium (Hempel)
facility. © May cause an allergic skin reaction.
02 | TurfFertilizer | Stored at | Pitch Harmful if swallowed. | Refer to Safety
| the level 2 Data Sheets in
| ofthe COSHH
stadium * Causes eye irritation. 0928/2020
facility.
© May cause cancer.
03 | Primer Paint | Storedat | AllFloors| * Flammable liquid and vapor. | Refer to Safety
the level 2 Runoff to sewer may create fire or| Data
of the explosion hazard,
stadium Sheets in MAS-
facility. $S-00205
© Inafire or if heated, « pressure
increase will occur, and the
container may burst with the risk of
(lotun)
Page 1 of[04 | Epoxy Floor | Stored at | Floors © Danger of serious damage to| Refer to Safety
the level 2 health by prolonged exposure| Sheets in MAS-
| coating ofthe through inhalation, irritating to| AR-00327
| stadium eyes and skin. (lotun)
| ‘facility. * May cause sensitization by skin
contact.
© Toxic to aquatic organisms, may
cause long- term adverse effects in
the aquatic environment.
© Ina fire or if heated, a pressure
inerease will occur, and the
container may burst.
05 | Decorative | Stored at | Walls & ‘© May cause an allergic skin reaction | Refer to Safety
the level 2 Data sheets in
Painting ofthe | Ceiling ‘MAS-PD- 00458
i © Causes serious eye damage
stadium (otun)
facility
© May cause sensitization by skin
contact
© Ina fire or if heated, a pressure
increase will occur, and the
container may burst
"06 | Decorative | Storedat | Walls & ‘Avoid inhalation, contact with skin| Refer to Safety
| thelevel2 | and eyes and do not swallow Data Sheets in
Painting ofthe | Ceiling ‘MAS-PD- 00298
stadium # Toke precautions against possible | (empel)
facility. risk of fire or explosions as well as
protection of the environment |
07 intumescent | Stored at | Structural | Flammable liquid and vapor. | Refer to Safety
; the level 2 ‘© Runoff to sewer may create fire or | Data Sheets in
Painting | of the | Steelwork explosion hazard. MAS-PD- 00261
stadium © Inafire or if heated, a pressure | (Hempel)
facility. increase will occur, and the |
container may burst with the risk of
a subsequent explosion.
08 Diesel Plant Highly flammable substance. Refer to Safety
house Environmental contamination. Data Sheets in
Explosion hazard. ‘MAS-PD- 00272
(Wogood)