RESIDENTIAL DEVELOPMENT

AYINGBA, KOGI STATE

DECEMBER 2023

Architectural Drawings Arclits Studio


CONSTRUCTION DOCUMENT
30m

1343 TANK

3750
8
08
69

5021

4406

FUTURE DEVELOPMENT
MAIN BUILDING

34m

10583

13
9893
PARKING

02
9
ACCESS ROAD

18/12/2023 13:05:47
NOTE : APRN :
PROJECT Architectural Drawing
Date
- DO NOT SCALE DRAWING, USE FIGURED DIMENSIONS ONLY.
CLIENT DRAWING TITLE DECEMBER 2023
----
- ALL DIMENSIONS ARE GIVEN IN METRIC SYSTEM AND TO NEAREST MILLIMETER [mm]

Arclits Studio Matthew oko-oboh SITE PLAN


- ANY DISCREPANCY ON SITE SHOULD BE REFERRED TO THE ARCHITECT FOR
Design by IKECHUKWU ONEUGBU
CLARIFICATIONS BEFORE PROCEEDING WITH NEW WORKS.
- ARCHITECTURAL DRAWING ARE TO BE READ IN CONJUNCTION WITH RELEVANT
ENGINEERING DRAWINGS.
A001
- STANDARD OF CONSTRUCTION SHOULD CONFORM WITH ARCHITECTS AND Drawn by IKECHUKWU ONUEGBU

Akhigbe
ENGINEERING DRAWINGS.
- ALL CRITICAL CONSTRUCTION STAGES SHOULD BE APPROVED BY THE ARCHITECT.
Checked by DELE ODEDIRAN Scale 1 : 200
Email : arclits@gmail.com
1 2 3 4 5 6 7 8 9 10

855 275 2700 1020 1430 1450 1280 2637 613


230 1005 1200 1395 230 1610 150 1910 230 1195 1200 1290 230

A A

230

230 765 230


995

995
1665
1575
B B

2400

2400
BATH BATH

1000 555
3578 4 m² 5 m²

1595

1595
3685

3945
250 750

2015
1200
C C

1395 150

150
BEDROOM 3

4500
1395
1585

1585
15 m²

230 1170

1945

1200
2945
D D

230

230
2400 5135
BEDROOM 4

1550

1550
BATH

885 230 1285


1360

1360

1510

900
3 m² 21 m²

E E

230
150
1200 165
1550 1000 2070

1915
4620

4950
2

1200
A005

425

3440
3630

3630
1200 230 5750 230

1270
1200
BEDROOM 2

940
19 m²

230450

775
LIVING ROOM
F F

1200
45 m²

7675

7675
20708

20730
1730 3720

2055

1565
3485

3485
3255

3255

3255
LOBBY DINING
6 m² 11 m²

1200

1200
G G
1055 230

1500 4250

745 230 1200 230685


790

790
4620
H H

230 1200 230


230457
KITCHEN V.TOILET

3230
1430

1430
2980
1200

14 m² 1730 748 230 3 m²2430

I I
ANTE ROOM
1010

1010
230 745

3285
9 m² GREEN
J J

230

2300
6 m²
5195 230 2500

1568
2400
1547

1547
1317

1317
1500

BEDROOM 1

230

230
K 150 K
750 213

17 m²

BATH
4200
1200

ENTRANCE
4 m² 1955

1955
2170

2170
5 m²
3370 1595 2960 505
2710
1920
1500

L L

230
713

713
230

M M
230

230 1173 1200 998 230 1595 230


0 750 527 1223 230 2407 230

18/12/2023 13:05:51
855 275 2700 1020 1430 1450 1280 2637 613

13090

1 23 4 5 6 7 8 9 10
NOTE : APRN :
PROJECT 1
Architectural Drawing
Date
- DO NOT SCALE DRAWING, USE FIGURED DIMENSIONS ONLY.
CLIENT DRAWING TITLE January 2016
---- A005
- ALL DIMENSIONS ARE GIVEN IN METRIC SYSTEM AND TO NEAREST MILLIMETER [mm]

Arclits Studio Matthew oko-oboh GROUND FLOOR


- ANY DISCREPANCY ON SITE SHOULD BE REFERRED TO THE ARCHITECT FOR
Design by Onuegbu . I .
CLARIFICATIONS BEFORE PROCEEDING WITH NEW WORKS.
- ARCHITECTURAL DRAWING ARE TO BE READ IN CONJUNCTION WITH RELEVANT
ENGINEERING DRAWINGS.
A002
PLAN
- STANDARD OF CONSTRUCTION SHOULD CONFORM WITH ARCHITECTS AND Drawn by Onuegbu . I .

Akhigbe
ENGINEERING DRAWINGS.
- ALL CRITICAL CONSTRUCTION STAGES SHOULD BE APPROVED BY THE ARCHITECT.
Checked by ---- Scale 1 : 100
Email : arclits@gmail.com
1 23 4 5 6 7 8 9 10

2
A005

G
H

L
M

18/12/2023 13:05:51
1
A005

NOTE : APRN :
PROJECT Architectural Drawing
Date
- DO NOT SCALE DRAWING, USE FIGURED DIMENSIONS ONLY.
CLIENT DRAWING TITLE January, 2106
----
- ALL DIMENSIONS ARE GIVEN IN METRIC SYSTEM AND TO NEAREST MILLIMETER [mm]

Arclits Studio Matthew oko-oboh ROOF PLAN


- ANY DISCREPANCY ON SITE SHOULD BE REFERRED TO THE ARCHITECT FOR
Design by Onuegbu . I .
CLARIFICATIONS BEFORE PROCEEDING WITH NEW WORKS.
- ARCHITECTURAL DRAWING ARE TO BE READ IN CONJUNCTION WITH RELEVANT
ENGINEERING DRAWINGS.
A004
- STANDARD OF CONSTRUCTION SHOULD CONFORM WITH ARCHITECTS AND Drawn by Onuegbu . I .

Akhigbe
ENGINEERING DRAWINGS.
- ALL CRITICAL CONSTRUCTION STAGES SHOULD BE APPROVED BY THE ARCHITECT.
Checked by ---- Scale 1 : 100
Email : arclits@gmail.com
ROOF TOP
8494

4594
1728
8485

ROOF LEVEL

300
300

3900
6282

150

3300
3600

3020
2870
Ground Floor
300 75

300
300

18/12/2023 13:05:54
NOTE : APRN :
PROJECT Architectural Drawing
Date
- DO NOT SCALE DRAWING, USE FIGURED DIMENSIONS ONLY.
CLIENT DRAWING TITLE 02/04/16
----
- ALL DIMENSIONS ARE GIVEN IN METRIC SYSTEM AND TO NEAREST MILLIMETER [mm]

Arclits Studio Matthew oko-oboh APPROACH


- ANY DISCREPANCY ON SITE SHOULD BE REFERRED TO THE ARCHITECT FOR
Design by Onuegbu . I
CLARIFICATIONS BEFORE PROCEEDING WITH NEW WORKS.
- ARCHITECTURAL DRAWING ARE TO BE READ IN CONJUNCTION WITH RELEVANT
ENGINEERING DRAWINGS.
A007
ELEVATION
- STANDARD OF CONSTRUCTION SHOULD CONFORM WITH ARCHITECTS AND Drawn by Onuegbu . I .

Akhigbe
ENGINEERING DRAWINGS.
- ALL CRITICAL CONSTRUCTION STAGES SHOULD BE APPROVED BY THE ARCHITECT.
Checked by ---- Scale 1 : 75
Email : arclits@gmail.com
10 9 8 7 6 5 4 32 1

ROOF TOP
8494

4594
3214

1728
8485

ROOF LEVEL

300
3900

3300
Ground Floor

300
300

18/12/2023 13:05:58
NOTE : APRN :
PROJECT Architectural Drawing
Date
- DO NOT SCALE DRAWING, USE FIGURED DIMENSIONS ONLY.
CLIENT DRAWING TITLE January, 2016
----
- ALL DIMENSIONS ARE GIVEN IN METRIC SYSTEM AND TO NEAREST MILLIMETER [mm]

Arclits Studio Matthew oko-oboh REAR ELEVATION


- ANY DISCREPANCY ON SITE SHOULD BE REFERRED TO THE ARCHITECT FOR
Design by Onuegbu . I .
CLARIFICATIONS BEFORE PROCEEDING WITH NEW WORKS.
- ARCHITECTURAL DRAWING ARE TO BE READ IN CONJUNCTION WITH RELEVANT
ENGINEERING DRAWINGS.
A008
- STANDARD OF CONSTRUCTION SHOULD CONFORM WITH ARCHITECTS AND Drawn by Onuegbu . I .

Akhigbe
ENGINEERING DRAWINGS.
- ALL CRITICAL CONSTRUCTION STAGES SHOULD BE APPROVED BY THE ARCHITECT.
Checked by ---- Scale 1 : 75
Email : arclits@gmail.com
A B C D E F G H I J K L M

ROOF TOP
8494

4594
ROOF LEVEL

300
3900

900

3300
3600

2400
Ground Floor

300
300

18/12/2023 13:06:01
NOTE : APRN :
PROJECT Architectural Drawing
Date
- DO NOT SCALE DRAWING, USE FIGURED DIMENSIONS ONLY.
CLIENT DRAWING TITLE 02/18/15
----
- ALL DIMENSIONS ARE GIVEN IN METRIC SYSTEM AND TO NEAREST MILLIMETER [mm]

Arclits Studio Matthew oko-oboh LEFT ELEVATION


- ANY DISCREPANCY ON SITE SHOULD BE REFERRED TO THE ARCHITECT FOR
Design by Designer
CLARIFICATIONS BEFORE PROCEEDING WITH NEW WORKS.
- ARCHITECTURAL DRAWING ARE TO BE READ IN CONJUNCTION WITH RELEVANT
ENGINEERING DRAWINGS.
A009
- STANDARD OF CONSTRUCTION SHOULD CONFORM WITH ARCHITECTS AND Drawn by Arc. Ikechukwu Onuegbu

Akhigbe
ENGINEERING DRAWINGS.
- ALL CRITICAL CONSTRUCTION STAGES SHOULD BE APPROVED BY THE ARCHITECT.
Checked by ---- Scale 1 : 75
Email : arclits@gmail.com
M L K J I H G F E D C B A

ROOF TOP
8494

4594
2707

ROOF LEVEL
150 430

300
3900

730
150

3300
2645
3020

2870

2870
Ground Floor
300

300
300

18/12/2023 13:06:05
NOTE : APRN :
PROJECT Architectural Drawing
Date
- DO NOT SCALE DRAWING, USE FIGURED DIMENSIONS ONLY.
CLIENT DRAWING TITLE 02/18/15
----
- ALL DIMENSIONS ARE GIVEN IN METRIC SYSTEM AND TO NEAREST MILLIMETER [mm]

Arclits Studio Matthew oko-oboh RIGHT ELEVATION


- ANY DISCREPANCY ON SITE SHOULD BE REFERRED TO THE ARCHITECT FOR
Design by Designer
CLARIFICATIONS BEFORE PROCEEDING WITH NEW WORKS.
- ARCHITECTURAL DRAWING ARE TO BE READ IN CONJUNCTION WITH RELEVANT
ENGINEERING DRAWINGS.
A010
- STANDARD OF CONSTRUCTION SHOULD CONFORM WITH ARCHITECTS AND Drawn by Arc. Ikechukwu Onuegbu

Akhigbe
ENGINEERING DRAWINGS.
- ALL CRITICAL CONSTRUCTION STAGES SHOULD BE APPROVED BY THE ARCHITECT.
Checked by ---- Scale 1 : 75
Email : arclits@gmail.com