REPORT
Uppgjord Prepared Datum Date Rev
1 (2)
Dokument nr Document no
2002-06-28
Ert datum Your date
TF 02:075
Tillhr reference File/reference
Reference levels expressed as power density (W/m , rms) Frequency 0.4 2 GHz 2 300 GHz
* f = frequency in MHz
Reference levels expressed as power density (W/m , rms) Occupational exposure 22.5 45 50 General public exposure 4.5 9 10
ICNIRP, Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz), International Commission on Non-Ionizing Radiation Protection (ICNIRP), Health Physics, vol. 74, pp 494-522, April 1998.
INTERNAL LIMITED
Dokument - Document Blad - Sheet
REPORT
Datum Date Rev
2(2)
Dokumentnr Document no
2002-06-28
TF- 02:075
where Slim is the reference level expressed as power density (W/m2 ), P (W) is the total rms power fed to the antenna (sum of all transmitter channels minus feeder and combiner losses) and G is the numerical far-field antenna gain, which is given by the far-field radiation pattern received from the antenna manufacturer.
Example. Calculation of compliance distance in front of an antenna The compliance distance for the general public in front of an antenna should be determined. The directional antenna is operating in the 1800 MHz frequency band and has an antenna gain of 7dBi. The antenna has an output power of 3 W. The ICNIRP general public reference level at 900 MHz is 4.5 W/m2. The numerical antenna gain is about 5 [10lg(5) 7dBi]. The compliance distance in the main lobe is:
d lim =
35 4 4.5
= 0.5 m