Engineering Design Summary

Company PT. KUDA - KUDA TOTAL PRIMA Truss ID T1


Client Susteran System GalvaSteel
Job No G 24A114 Design Code AS/NZS 4600:2005-S
Dwg No. [Link] Wind Speed W30
Print Date 03-12-2024 Roof Load METALTILE
Overall Status Passed Truss Spacing 1300
Overall Capacity 46% BC Restraint 1400
TC Restraint 385

Materials Used Z75/08, C65/08,


Reactions Up (L>R) 1410,1019,
Reactions Dn (L>R) 3889,3646,

Load Case Results

Load Case 1 1.0G 14% Load Case 9 1.2G + 1.5P 45%


Load Case 2 Ws 18% Load Case 10 1.2G + 1.5P 38%
Load Case 3 1.2G + 1.5Q 30% Load Case 11 1.2G + 1.5P 37%
Load Case 4 0.9G + Wu 12% Load Case 12 1.2G + 1.5P 36%
Load Case 5 1.2G + Wd 29% Load Case 13 1.2G + 1.5P 36%
Load Case 6 1.2G + 1.5P 43% Load Case 14 1.2G + 1.5P 38%
Load Case 7 1.2G + 1.5P 46% Load Case 15 1.2G + 1.5P 23%
Load Case 8 1.2G + 1.5P 46%