P ( kN)

9000

y
fs=0 fs=0
x

(Pmax) (Pmax)

fs=0.5fy fs=0 fs=0 fs=0.5fy

fs=0.5fy fs=0.5fy
600 mm diam.

Code: ACI 318-14

Units: Metric

Run axis: About X-axis


1
Run option: Design
-700 700
Slenderness: Not considered
Mx ( kNm)
Column type: Structural

Bars: ASTM A615

Date: 10/23/21 (Pmin) (Pmin)


Time: 19:09:09 -3000

STRUCTUREPOINT - spColumn v6.00 (TM). Licensed to: Ruminsar, CV.Etama Maju Bersama. License ID: -XXXXX

File: untitled.col
Project: DPT Bored Pile SYA 88+140
Column: Engineer:
f'c = 25 MPa fy = 420 MPa Ag = 282743 mm^2 16 #7 bars
Ec = 23500 MPa Es = 200000 MPa As = 6194 mm^2 rho = 2.19%
fc = 21.25 MPa e_yt = 0.0021 mm/mm Xo = 0 mm Ix = 6.36e+009 mm^4
e_u = 0.003 mm/mm Yo = 0 mm Iy = 6.36e+009 mm^4
Beta1 = 0.85 Min clear spacing = 67 mm Clear cover = 60 mm
Confinement: Tied
phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65