400 My ( kNm)

Mx ( kNm)
550 mm diam. 1
-400 400
Code: ACI 318-08

Units: Metric

Run axis: Biaxial

Run option: Design

Slenderness: Not considered

Column type: Structural

Bars: User-defined

Date: 12/03/12

Time: 16:46:22

-400
P = 1668 kN

spColumn v4.50. Licensed to: Microsoft, Microsoft. License ID:

File: c:\users\sony\desktop\cambio.col
Project: LOSA DE FUNDACION
Column: B-2 Engineer: JHONNY
f'c = 21 MPa fy = 420 MPa Ag = 237583 mm^2 6 #25 bars
Ec = 21538 MPa Es = 218820 MPa As = 2946 mm^2 rho = 1.24%
fc = 17.85 MPa Xo = 0 mm Ix = 4.49e+009 mm^4
e_u = 0.003 mm/mm Yo = 0 mm Iy = 4.49e+009 mm^4
Beta1 = 0.85 Min clear spacing = 208 mm Clear cover = 30 mm
Confinement: Tied
phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65