You are on page 1of 2

Calculation of Internal Stress in Reinforced Concrete

With the single bar for spread footing

Structure Unit Single The Character


Member Bar of Steel & Reinforce
Coloumn Data :
M kNm 24 fy =
Pu kN 280 fc' =
e m 0,09
b mm 400 σ ijin tanah =
h mm 400 ϒc =
lu m
Spread Footing Data :
B mm 2000
L mm 3000
h mm 200

p mm 40
φ stirrup mm 0
φ main mm 16
d = h - p - φ stir - 0,5.φ main mm 152
d' = p + φ stir + 0,5.φ main mm 48
d'/d = 0.315789
Loading Capacity Form :
Column = (b h lu) ϒc kN 0
Spread Footing = (B L h) ϒc kN 28.8
Total Load = Pu + Col + Spread Foot kN 308.8

Calculate Bearing Capacity :


σmax = (Pt/(B L)+(M/W)) kN/m2
σmin= (Pt/(B L)-(M/W)) kN/m2
W = 1/6 B (L^2) m3
The Character Unit
of Steel & Reinforce

400 mPa
20 mPa

95 kN/m^2
24 kN/m^2