C60HB202

miniature circuit breaker - C60HB - 2 poles - 2 A - B curve BSEN

Main
Circuit breaker application Range of product Device short name Poles description Number of protected poles Network type Trip unit technology Curve code Suitability for isolation Distribution C60 C60H 2P 2 AC DC Thermal-magnetic B
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Yes IEC 60947-2

Complementary
[In] rated current Network frequency [Ue] rated operational voltage Magnetic tripping limit Breaking capacity 2 A 30 C 50/60 Hz 12...440 V AC 50/60 Hz 3...5 x In 10 kA Icn EN 60898 230/400 V AC 50/60 Hz 10 kA Icu IEC 60947-2 440 V AC 50/60 Hz 15 kA Icu IEC 60947-2 400...415 V AC 50/60 Hz 25 kA Icu IEC 60947-2 125 V DC 2P 30 kA Icu IEC 60947-2 230...240 V AC 50/60 Hz 40 kA Icu IEC 60947-2 125 V DC 3P 50 kA Icu IEC 60947-2 250 V DC 4P 7.5 kA EN 60898 230/400 V AC 50/60 Hz 15 kA IEC 60947-2 230...240 V AC 50/60 Hz 5 kA IEC 60947-2 440 V AC 50/60 Hz 7.5 kA IEC 60947-2 400...415 V AC 50/60 Hz 3 IEC 60947-2 500 V AC 50/60 Hz IEC 60947-2 6 kV IEC 60947-2 Yes Toggle ON/OFF indication Fixed 35 mm symmetrical DIN rail NO 4 81 mm 36 mm 73 mm 0.24 kg 20000 cycles Tunnel type terminals 16 mm flexible Tunnel type terminals 25 mm rigid 2 N.m downside 2 N.m upside power circuit Separate block C60 accessories C60 auxiliary

[Ics] rated service breaking capacity

Limitation class [Ui] rated insulation voltage [Uimp] rated impulse withstand voltage Contact position indicator Control type Local signalling Mounting mode Mounting support Comb busbar distribution block compatibility 9 mm pitches Height Width Depth Product weight Mechanical durability Connections - terminals Tightening torque Earth-leakage protection Product compatibility

Mar 7, 2012

Environment
Standards Tropicalisation Relative humidity Operating altitude Ambient air temperature for operation Ambient air temperature for storage EN 60898 IEC 60947-2 2 IEC 60068-1 95 % 55 C 2000 m -25...60 C -40...70 C