In this issue of ZTE's Maintenance Experience, we continue to pass on various field reports and resolutions that are gathered by ZTE engineers and technicians around the world. The content presented in this issue is as below: One Special Document Six Maintenance Cases of ZTE's Data Products Have you examined your service polices and procedures lately? Are you confident that your people are using all the tools at their disposal? Are they trained to analyze each issue in a logical manner that provides for less downtime and maximum customer service? A close look at the cases reveals how to isolate suspected faulty or mis-configured equipment, and how to solve a problem step by step, etc. As success in commissioning and service is usually a mix of both discovery and analysis, we consider using this type of approach as an example of successful troubleshooting investigations. While corporate leaders maintain and grow plans for expansion, ZTE employees in all regions carry out with individual efforts towards internationalization of the company. Momentum continues to be built, in all levels, from office interns to veteran engineers, who work together to bring global focus into their daily work. If you would like to subscribe to this magazine (electronic version) or review additional articles and relevant technical materials concerning ZTE products, please visit the technical support website of ZTE Corporation (http://ensupport.zte.com.cn). If you have any ideas and suggestions or want to offer your contributions, you can contact us at any time via the following email: doc@zte.com.cn. Thank you for making ZTE a part of your telecom experience!

Maintenance Experience
Bimonthly for Data Products No.13 Issue 160, April 2009

Maintenance Experience Editorial Committee

Director: Qiu Weizhao Deputy Director: Chen Jianzhou Editors: Jiang Guobing, Zhang Shoukui, Wu Feng, Yuan Yufeng, Tang Hongxuan, Li Gangyi, Song Jianbo, Tian Jinhua, Wang Zhaozheng, Liu Wenjun, Wang Yapping, Lei Kun, Wang Tiancheng, Ge Jun, Yu Qing, Zhang Jiebin, Fang Xi Technical Senior Editors: Hu Jia, Bai Jianwen Executive Editor: Zhang Fan

Maintenance Experience Newsroom


Address: ZTE Plaza, Keji Road South, Hi-Tech

Maintenance Experience Editorial Committee ZTE Corporation April, 2009

Industrial Park, Nanshan District, Shenzhen, P.R.China Postal code: 518057 Contact: Song Chunping Tel: +86-755-26770600, 26771195 Fax: +86-755-26772236 Document Support Email: doc@zte.com.cn Technical Support Website: http://ensupport.zte. com.cn

Contents

NetNumen N31 Unified Management System......................................................................................... 02 SQL Server Installation Failure ................................................................................................................ 05 Member Switch in Cluster Displaying as CO ........................................................................................... 06 NE MAC Address Collision ...................................................................................................................... 07 Network Interruption Caused by MAC Address Offset ............................................................................ 09 Surfing Internet in MAN ........................................................................................................................... 12 Operational Failure through ACL ............................................................................................................. 15 Surfing Internet in MAN ........................................................................................................................... 17 Operational Failure through ACL ............................................................................................................. 20 Abnormal EBGP Neighborhood Establishment ....................................................................................... 21 Telnet with Slow Speed ........................................................................................................................... 24

April 2009

Issue 160

NetNumen N31 Unified Management System


Ye Dezhong, Lu yinghua / ZTE Corporation
Key words: NetNumen N31

NetNumen N31 Overview


At present, network techniques develop vigorously. More and more key applications and services are established on the base of data network. Therefore, it is very important to ensure that the network works normally and efficiently. Network operators, Internet service providers and enterprises must implement effective managements and plans to the network system to meet the growing requirements of users to the maximum extent. To establish, deploy and use the network quickly, as well as keep the network running conveniently, a data network management system with powerful functions, good extensibility and high performance is recommended. On the other hand, due to the fast changing market, declining product life cycle and increasing market launch press, network operators are facing intense competition. Therefore, requirement of effective network management system is needed in order to decrease operating cost and improve network quality. In addition, considering the increasing software development cost and demand for supporting different operating systems and hardware platforms, network operators have to find a technique that can help them to improve productivity greatly. In

the current situation, technique and demand keeps changing continually. It is important for most equipment manufacturers and software developers to make their product support different operating systems and hardware platforms. To meet the changing requirements of their users, equipment manufacturers must provide a network management system that can run in different platforms and support Web. ZTE holds the pulse of the times and develops NetNumen N31 Unified Management System. This is a high customization cross-platform network management system of carrier class. It is on the base of new Internet technique and it is designed according to rules from bottom to top. It can be used to manage all ZTE data products. It covers network element management, network management and service management.

NetNumen N31 Functions


NetNumen N31 has the following functions. 1.

Providing unified network management. NetNumen N31 can be used to manage all ZTE data products. NetNumen N31 covers Management levels of network element, network and service, providing perfect network management functions.

NetNumen N31 can be integrated with network management systems of NGN and ADSL to implement unified management.

Maintenance Experience

www.zte.com.cn

2.

Providing different management privileges

ability. When a server in the system is down, other servers can take over the tasks. This ensures that the services will not be intermitted.

and implementing management in different areas. Users can access the management system in different areas with different management privileges. 3.

Supporting different platforms and different NetNumen N31 uses J2EE architecture and it is developed in JAVA. Therefore it supports different platforms and operating systems such as UNIX, LINUX and WINDOWS.

NetNumen N31 provides good system management ability. Data information of NetNumen N31 management system can be monitored.

databases.

10. Providing good openness. NetNumen N31 supports standard SNMP and it provides CORBA interface, SNMP interface and TL1 interface. NetNumen N31 can be integrated with third party systems, providing convenience for offices to implement OSS system application. 11. Providing perfect after sale service. NetNumen N31 uses are provided with 247 after sale service of ZTE. The management functions of NetNumen N31 management system cover four layers of TMN management layers, including Network Element (NE) layer, NE management layer, network management layer and service management layer. The core is the function modules in network management layer. The structure of NetNumen N31 management system is shown in Figure 1.

NetNumen N31 supports databases such as MSSQL, SYBASE and ORACLE. Providing convenient extension and up-

4. grade.

NetNumen N31 uses modularization structure. It is with good extension and upgrade ability. 5.

Providing special management functions. Policy management Fast network automatic discovery Fault processing expert base Report processing Configuration management based on task Network statistics Supporting localization.

6.

NetNumen N31 supports Chinese and English. Users can select the language during the installation to implement localization management. 7. Complying with high standards NetNumen N31 complies with TMN series suggestions defined by ITU-T. NetNumen N31 also complies with a series of network management protocols defined in RFC and network management suggestions in TMF. 8.

Providing high security. NetNumen N31 provides perfect access privilege control. NetNumen N31 provides perfect security log records. Providing high reliability. NetNumen N31 supports local backup and remote recovery. NetNumen N31 is with good fault tolerance

9.

Figure 1. Structure of NetNumen N31 Management System

Data Products

April 2009

Issue 160

Network Modes
NetNumen N31 is a network management system on the base of data communication network. It can be used to maintain and manage different network devices located in different areas in complicated application situations. Therefore, centralized management mode is usually used, that is, a network management system manages a lot of devices locating in the managed network centrally. In centralized management mode, network management system comprises server and clients. There is only one server in the whole managed network. The server implements interactions with all managed devices. There are multiple clients. The clients connect the server and implement human-computer interactions with users. Clients do not connect devices directly. There are two modes to configure client, local terminal and remote terminal.
Figure 2. Remote Terminal Mode

When the system manages a cross-area network, the network is divided into multiple subnets (by zone or by device type). All devices in this network connect higher layer management system and implement management information interactions. Administrators in higher layer management center can monitor the whole network (including the subnets) running condition through local terminal. In lower layer management center, remote terminals connect the NMS server. Therefore, administrators can monitor the subnets locally. In lower layer management center, there is no server. There are management terminals. Management information interactions between management terminal and all devices in a subnet are implemented through the server in higher layer management center. Management privileges can be set on the server according to management area and contents. When administrators in lower layer management center log in to the server, they can only access subnets corresponding to their privileges. Administrators can monitor the subnet through graphics interactions and obtain different reports on management terminals. In management contents, it equals to MANAGER-AGENT mode. Through remote terminal mode, management privileges of subnets are assigned by higher layer management system, and data is maintained by higher layer management system. This ensures that higher layer management system can monitor the whole network in real time and it can obtain accurate and reliable data.

Local terminal mode

In this mode, the server and clients are in the same LAN. The clients implement centralized management in the whole network together with the server.

Remote terminal mode

In this mode, clients connect the server through WAN. The client may locate in remote device room. The managed network is divided into different management areas. Each client manages devices in local area. Clients do not connect devices directly. Management of different layers in centralized management mode can be implemented through remote terminals, as shown in Figure 2.

Maintenance Experience

www.zte.com.cn

SQL Server Installation Failure


Wang Xinlin / ZTE Corporation
Key words: SQL, installation failure

Malfunction Situation
When users install SQL, the system may usually prompt installation failure. The reason is that users have installed database before but the database files were not deleted completely.

Solution
To delete the database files completely, perform the following steps. 1. 2. 3.

Uninstall the database program through Add or Remove Programs in Control Panel. Delete the whole Microsoft SQL Server file manually. Click Start Run and input regedit to open Registry Editor, and then delete the followHKEY_CURRENT_USER\Software\Microsoft\Microsoft SQL Server HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Microsoft SQL Server HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\MSSQLServer Reboot the system. Install SQL again.

ing items.

4. 5.

Data Products

April 2009

Issue 160

Member Switch in Cluster Displaying as CO


Zhang Jintao / ZTE Corporation
Key words: cluster management, CO, C, ZTP, NetNumen N31

Malfunction Situation
ZXR10 2818S switches work as member switches in a cluster. As shown in Figure 1, switches are displayed as CO in NetNumen N31 network management platform. However, in normal situation, switches must be displayed as C. When switches are displayed as CO, there is no telnet option in the shortcut menu if users right-click the switches.

switch or an external member switch of the cluster.

An internal member switch of a cluster appears in both Device table and Group member table. An external member switch of a cluster appears only in Device table but not in Group member table.

Sometimes, users may find that a switch appears both in Device table and Group member table, but it is displayed as CO on network management server. The reason is that that switch worked as a member switch, the link between the member switch and the command switch was down and a moment later it was recovered, but states on the command switch was not refreshed. Users are recommended to implement topology collection to refresh the state on the command switch.

Figure 1. Member Switch in Cluster Displaying as CO

Malfunction Analysis
When the switch is displayed as C, it is an internal member switch of the cluster. When the switch is displayed as CO, it is an external member switch of the cluster. In a switch cluster, there are two important tables on the command switch, Device table and Group member table. Users can view the information in the two tables with show ztp device-list command and show group member command. The following rules are used to judge whether a switch is an internal member

Solution
To solve the problem, perform the following steps. 1. Delete the member switches on the command switch and then add the member switches again. This ensures that the state of member switches in Group member table is up and users can log in to member switches through command switch. 2. 3. Input ztp start command on command Right-click the command switch in topolswitch to collect topology information again. ogy management view and then select Update State in the shortcut menu. The member switches are displayed as C.

Maintenance Experience

www.zte.com.cn

NE MAC Address Collision


Zhou Hongwei / ZTE Corporation
Key words: NetNumenN31, MAC address collision

Malfunction Situation
There are two NEs (ZXR10 T64G) with the same name Miriyalguda in NetNumenN31 network management system. They are in different groups, as shown in Figure 1. address collision. Engineers logged into the two NEs and checked the MAC addresses. Engineers found that the MAC address were the same indeed. The MAC address was 00d0.d0c7.ffe1, as shown in Figure 2.

Figure 1. Same NEs

Malfunction Analysis
Engineers checked the information of the NEs. The NEs had the same information, including IP address. Engineers considered that it may be caused by MAC

Figure 2. MAC Address

Solution
The same MAC address on two NEs resulted in the MAC address collision in NetNumenN31 network management system. Therefore, it was

Data Products

April 2009

Issue 160

necessary to modify the MAC address in one of the NEs. To modify the MAC address on one NE through remote connection, engineers took the following steps. 1. Engineers defined an address

of the switch with the following command. ZXR10(config-increte)#mac-base-addr add master/slave mng <mac-address> { 1-4 } At present, four MAC address could be specified on administration interface. However, only one administration interface was needed on G series switches. Therefore it was necessary to configure one MAC address. It was not necessary to set the MAC address for administration interface according to the address segment range defined on service interface. After defining address segment range on administration interface, engineers input the following command. ZXR10(config-increte)#mac-base-addr enable master/slave After this command was configured, MAC address was distributed in new mode and it was saved in nvram of the switch. After the switch was rebooted, the new MAC address distribution mode would be loaded in memory and take effect. 3. Engineers saved the above configuration.

segment range on service interface of the switch with the following command. ZXR10(config-increte)#mac-base-addr add master / slave <mac-address> { 8 | 16 | 32 } 8, 16 and 32 were used to specify the MAC address range. If the MAC address range was set as 8, the last three bits of MAC address must be 0. If the MAC address range was set as 16, the last four bits of MAC address must be 0. If the MAC address range was set as 32, the last five bits of MAC address must be 0. After defining address segment range on service interface, engineers input the following command. ZXR10(config-increte)#mac-base-addr enable master/slave After this command was configured, MAC address was distributed in new mode and it was saved in nvram of the switch. After the switch was rebooted, the new MAC address distribution mode would be loaded in memory and take effect. 2. Engineers defined an address

It was not necessary to save the configuration manually. After the configuration, the above commands were saved in nvram of the switch automatically. They would take effect after the switch was rebooted. The above configuration also could be saved manually with the following command. ZXR10# write nvram

segment range on administration interface

Maintenance Experience

www.zte.com.cn

Network Interruption Caused by MAC Address Offset


Ye Wei / ZTE Corporation
Key words: network interruption, MAC address offset

Malfunction Situation
After the software version of T160G in a city is upgraded, services running on a DSLAM connected to this T160G were interrupted and it failed to access NMS of the DSLAM. T160G provides L2 transparent transmission for services of DSLAM. NMS of DSLAM and that of T160G were in the same network segment. The network topology is shown in Figure 1. T160G#show mac interface fei_3/43 Total MAC address : 96 Flags: vid -VLAN id,stc-static, per-permanent, toS-tostatic, srF-source filter,dsF-destination filter,time-day: hour:min:sec Frm-mac from where:0,drv:1,config:2,V PN:3,802.1X:4,micro:5,dhcp MAC_Address port vid stc per toS srF dsF Frm Time --------------------------------------------------------------------------------------0014.6c24.acf3 fei_3/43 123 0 0 0 0 0 0 0:01:06:30 0810.170c.551f fei_3/43 123 0 0 0 0 0 0 0:01:14:42 00e0.fc0e.4fe2 fei_3/43 6 0 0 0 0 0 0 0:01:05:40 3. Engineers viewed ARP information was normal. 2. Engineers viewed MAC entries of T160G and they found that MAC address learning was normal, as shown below.

tion of T160G. They found that ARP information of peer DSLAM could be learned. IP address of DSLAM was 221.9.122.6, as shown below.
Figure 1. Network Topology Diagram

Malfunction Analysis
To find out the problem, engineers took the following steps. 1. Engineers viewed alarm log of T160G and they found that there was no problem. All informa-

T160G#show arp int vlan 6 Arp protect mac is disabled The count is 2 IPAddress Age(min) HardwareAddress VLAN InterfaceID SubInterface ----------------------------------------------------------------------------------------221.9.122.6 0 00e0.fc0e.4fe2 vlan6 6 fei_3/43 221.9.122.5 00d0.d0c0.5721 vlan6 N/A N/A

Data Products

April 2009

Issue 160

4.

Engineers viewed direct-connect-

5.

Engineers pinged to NMS address of

ed route 221.9.122.6. The entries in hardware forwarding table were correct, as shown below. T160G#sho ip forwarding hostrt np 3 221.9.122.6 Host routing table: Flags:Int-internal label,Ext-external label,Tr-trunk flag, Mf-mpls flag,Vpn-vpn id, Loc-location(SW--switch,NP--network processer) IpAddr/Mask Mod/Port Vlan/Tag Int/Ext DestMac Tr/Mf/Vpn/Loc ------------------------------------------------------------------------------------221.9.122.6/32 3/43 6/1 untagged 00e0.fc0e.4fe2 0/0/0/SW

DSLAM through T160G, as shown below. T160G#ping 221.9.122.6 sending 5,100-byte ICMP echos to 221.9.122.6, timeout is 2 seconds. ..... Success rate is 0 percent(0/5).

6.

Engineers viewed MAC address

learning on T160G interface connected to HW5200G. MAC address learning was normal, as shown below. T160G#sho mac int gei_2/4 Total MAC address : 27 Flags: vid-VLAN id,stc-static,per-permanent,toS-to-static, srF-source filter,dsF-destination filter,time-day:hour:min:sec Frm-mac from where:0,drv;1,config;2,VPN;3,802.1X;4,micro;5,dhcp MAC_Address port vid stc per toS srF dsF Frm Time ----------------------------------------------------------------------------------------------00e0.fc5d.09c0 gei_2/4 196 0 0 0 0 0 0 0:02:58:08 00e0.fc5d.09c0 00e0.fc5d.09c0 00e0.fc5d.09c0 00e0.fc5d.09c0 00e0.fc5d.09c0 00e0.fc5d.09c0 00e0.fc5d.09c0 00e0.fc5d.09c0 00e0.fc5d.09c0 00e0.fc5d.09c0 00e0.fc5d.09c0 00e0.fc5d.09c0 gei_2/4 gei_2/4 gei_2/4 gei_2/4 gei_2/4 gei_2/4 gei_2/4 gei_2/4 gei_2/4 gei_2/4 gei_2/4 gei_2/4 166 55 194 105 193 121 104 165 167 178 198 123 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0:03:00:40 0:12:31:08 0:00:18:13 0:09:32:49 0:12:39:22 0:12:39:25 0:12:39:25 0:12:39:25 0:12:39:24 0:12:39:26 0:12:39:26 0:12:39:26

10

Maintenance Experience

www.zte.com.cn

learnt MAC address was the old MAC adThe above fault information showed that MAC address learning on T160G was normal and few forwarding entries and ARP learning were also correct. While after upgrade, services and NMSs of the other DSLAM devices were normal. This indicated that it was not the problem of T160G. After the upgrade, fault occurred and the difference before and after upgrade was that MAC address of T160G offsets for one bit. It was supposed that IP address and MAC address of T160G were bound in DSLAM. dress of T160G. Due to software problem, MAC learning and address aging function of DSLAM got invalid. After rebooting DSLAM, services ran normally.

Experience Summary
After upgrade, MAC address of T160G changed and the faulty DSLAM happened to have problem in MAC learning (MAC address aging function and MAC learning got invalid), which brought interruption of services. After engineers reboot the DSLAM, MAC address learning function restored and services ran normally.

Solution
Engineers checked configuration of DSLAM. They found that MAC binding was not set and the

Data Products

11

April 2009

Issue 160

Surfing Internet in MAN


Ye Wei / ZTE Corporation
Key words: QinQ, VLAN, uplink port, customer port

Network Topology
DSLAM and switches are down-linked to 3952. SVLAN is configured on 3952. Transparent transmission is configured on T64G. Leased-line users, NM and other services are terminated on T64E. PPPOE dial-in users are terminated on BAS. Network topology is shown in Figure 1.

The range of inner vlan id for PPPOE dial-in user: for DSLAMs, 100 vlans are allocated to each device with id range to be 101-500; for switches, 40 vlans are allocated to each device with id range to be 501-2500.

Malfunction Situation
The speed of surfing internet at peak hours was slow. Delay in sending ping packet was high, and some packets were lost. At this peak time devices ran normally, and other operational functions of the devices was normal.

Malfunction Analysis
To find out the problem, engineers took the folFigure 1. Network Topology

lowing steps. 1. Engineers viewed system CPU utilization when the speed of surfing internet was slow to make sure whether CPU utilization was too high to influence running of system. The result was shown below.

The planning of VLAN is as follows:


Leased line: 3001-3500 Network management system: 99 The range of outer vlan id for PPPOE dial-in user: 100

12

Maintenance Experience

www.zte.com.cn

ZXR10#show processor M: Master processor S: Slave processor Peak CPU: CPU peak utility measured in 2 minutes PhyMem: Physical memory (megabyte) Panel MP(M) 1 CPU(5s) 20% CPU(30s) 19% CPU(2m) 18% Peak 40% CPU PhyMem 256 Buffer Memory 0% 35.902%

The above information showed that the CPU was normal. 2. Engineers viewed traffics on interface. Traffics on port may also influence the speed of surfing internet. If the traffics were too large, congestion would occur, and then the speed of surfing internet could also be slowed down. Interface traffic information is shown below. ZXR10#show interface fei_1/1 fei_1/1 is up, line protocol is up Description is none Keepalive set:10 sec The port is electric Duplex full Mdi type:auto VLAN mode is access, pvid 4094 BW 100000 Kbits Last clearing of "show interface" counters never 120 seconds input rate: 3403245 Bps, 3117 pps 120 seconds output rate: 1122389 Bps, 11912 pps Interface peak rate: input 8120382 Bps, output 12420382 Bps Interface utilization: input 29%, output 90% Input: Packets: 19028174612 Bytes: 24122478262892 Unicasts: 18709469101 Multicasts: 19281980 Broadcasts: 299188371 Undersize: 230911 Oversize: 3247 CRC-ERROR: 9 Dropped: 1091 Fragments: 0 Jabber: 1002 MacRxErr: 0

Output: Packets: 142123550101 Bytes: 182329420262394 Unicasts: 56909126342 Multicasts: 729262387 Broadcasts: 84485161372 Collision: 0 LateCollision: 0 Total: 64B: 772661029 65-127B: 803872612 128-255B: 1292984228 256-511B: 2374859862 512-1023B: 63467072821 1024-1518B: 92427412536 The above information showed that traffics on customer port in outgoing direction were large and it caused congestion. Engineers viewed traffic information on other interfaces. They found that traffics in outgoing direction of other interfaces were also large. 3. Engineers viewed traffics on uplink interface, as shown below. ZXR10#show interface gei_2/1 gei_2/1 is up, line protocol is up Description is none Keepalive set:10 sec The port is electric Duplex full Mdi type:auto VLAN mode is access, pvid 4094 BW

Data Products

13

April 2009

Issue 160

1000000 Kbits Last clearing of "show interface" counters never 120 seconds input rate : 29123012 Bps, 29081 pps 120 seconds output rate: 14133829 Bps, 13909 pps Interface peak rate : input : 50234251 Bps, output 5292182 Bps Interface utilization: input 28%, output 19% The above information showed that traffics on uplink port were normal. 4. Engineers viewed alarm information. No abnormal alarm was presented and no MAC floating alarm occurred. Therefore, it was not loop that caused broadcast storm. 5. below. Engineers analyzed configuration on the device. QinQ configuration is shown

Port configuration is shown below. ZXR10(config)#show run interface fei_1/1 description TO-DS01 no negotiation auto switchport mode hybrid switchport hybrid native vlan 4094 switchport hybrid vlan 99 tag switchport hybrid vlan 100 untag switchport hybrid vlan 3001-3010 tag switchport qinq customer ZXR10(config)#show run interface fei_1/2 description TO-DS02 no negotiation auto switchport mode hybrid switchport hybrid native vlan 4094 switchport hybrid vlan 99 tag switchport hybrid vlan 100 untag switchport hybrid vlan 3011-3020 tag switchport qinq customer ZXR10(config)#show run interface fei_2/1 description to-T64G no negotiation auto hybrid-attribute fiber switchport mode hybrid switchport hybrid native vlan 1 Ovlan 100 100 100 100 100 100 Helpvlan switchport hybrid vlan 99 tag switchport hybrid vlan 101-150 tag switchport hybrid vlan 3001-3500 tag switchport hybrid vlan 501-2500 tag switchport hybrid vlan 4094 untag switchport qinq uplink

ZXR10(config)#show vlan qinq Session 1 2 3 4 5 6 Customer Uplink fei_1/1 fei_1/2 fei_1/3 fei_1/4 fei_1/5 fei_1/6 gei_2/1 gei_2/1 gei_2/1 gei_2/1 gei_2/1 gei_2/1 In_Vlan 101-200 201-300 301-400 401-500 501-540 541-580 -------------------------------------------------------------------

14

Maintenance Experience

www.zte.com.cn

With the above information results, engineers found that native VLAN on each port was Helpervlan 4094. Double-tagged services were implemented through VLAN QinQ. Therefore, MAC learning was in Helpervlan 4094, and the VLAN 100 would not learn MAC addresses. That is, packets in VLAN 100 were broadcasted to downstream devices. After asking the office personnel about services running, engineers knew that that there were a lot of double-tagged PPPOE services that were transparently transmitted. According to the plan, users were identified by inner tags and areas were identified by outer tags. Therefore, PPPoE service on ZXR10 3952 was

only allocated with one outer tag vlan 100, and all ports were in this vlan. From above information, downstream PPPOE traffics were broadcasted in VLAN 100. Since the uplink port was 1000M and the downstream traffics were great, but customer port was 100M, downstream broadcast traffics were congested. This made internet surfing slow.

Solution
Engineers set the outer tag VLAN id to native VLAN id on customer port. The problem was solved.

Operational Failure through ACL


Zhang Fan / ZTE Corporation
Key words: ACL, ping, protocol protection

Malfunction Situation
As shown in Figure 1, ACL was applied on interface Fei_1/1 of ZXR10 3928 switch to forbid PC to ping to 3928. The configuration failed but still PC could ping 3928 successfully.

Figure 1. Network Topology

Data Products

15

April 2009

Issue 160

Malfunction Analysis
Engineers checked configuration of ZXR10 3928 switch, as shown below. acl extend number 101 rule 1 deny icmp 10.40.184.0 0.0.3.255 any rule 2 permit ip any any ! int fei_1/1 protpcol-protect mode icmp disable switchport access vlan 1 ip access-group 101 0 in The command to apply ACL is shown below: ip access-group <acl-number> <profile-number> in In this command, parameter<profilenumber> is required. The value is 0 or 1. 0 indicates that protocol protection is enabled and 1 indicates protocol protection is disabled. Protocol protection is enabled by default on interface, that is, the default value of <profile-number> is 0. After protocol protection function was enabled, switch improved priority of ICMP packets through a set of special rules. These rules were placed ahead of ACL. ICMP was in protocol protection range. Protocol protected packet had a higher priority than ACL. As the value of parameter

<profile-number> on ZXR10 3928 switch was 0 by default, the command of disabling ICMP became invalid. As a result, PC could still ping to ZXR10 3928 switch successfully.

Solution
Engineers modified the configuration of ZXR10 3928 switch, as shown below. acl extend number 101 rule 1 deny icmp 10.40.184.0 0.0.3.255 any rule 2 permit ip any any ! int fei_1/1 protpcol-protect mode icmp disable switchport access vlan 1 ip access-group 101 1 in //Set the value of parameter profile-number to 1, that is, protocolprotect is disabled

Experience Summary
For downlink interface where SVLAN is enabled, the value of parameter <profile-number> must be 1. When protocol protection is enabled, the value of parameter <profile-number> must be 0. When a switch is used as L2 device, then value of parameter<profile-number> is allowed to be 1. However, in this situation, some control packets will fail to be received on the interface and some protocol calculations will be wrong. Therefore, set the value of parameter <profile-number> to 0.

16

Maintenance Experience

www.zte.com.cn

Surfing Internet in MAN


Ye Wei / ZTE Corporation
Key words: QinQ, VLAN, uplink port, customer port

Network Topology
DSLAM and switches are down-linked to 3952. SVLAN is configured on 3952. Transparent transmission is configured on T64G. Leased-line users, NM and other services are terminated on T64E. PPPOE dial-in users are terminated on BAS. Network topology is shown in Figure 1. some packets were lost. At this peak time devices ran normally, and other operational functions of the devices was normal.

Malfunction Analysis
To find out the problem, engineers took the following steps. 1. Engineers viewed system CPU utilization when the speed of surfing internet was slow to make sure whether CPU utilization was too high to influence running of system. The result was shown below. ZXR10#show processor

Figure 1. Network Topology

M: Master processor S: Slave processor Peak CPU: CPU peak utility measured in 2 minutes PhyMem: Physical memory (megabyte) Panel CPU(5s) CPU(30s) CPU(2m) MP(M) 1 20% 19% 18% Peak CPU PhyMem Buffer 40% 256 Memory 0% 35.902%

The planning of VLAN is as follows:


Leased line: 3001-3500 Network management system: 99 The range of outer vlan id for PPPOE dial-in user: 100 The range of inner vlan id for PPPOE dial-in user: for DSLAMs, 100 vlans are allocated to each device with id range to be 101-500; for switches, 40 vlans are allocated to each device with id range to be 501-2500.

The above information showed that the CPU was normal. 2. Engineers viewed traffics on interface. Traffics on port may also influence the speed of surfing internet. If the traffics were too large, congestion would occur, and then the speed of surfing internet could also be slowed down. Interface traffic information is shown below.

Malfunction Situation
The speed of surfing internet at peak hours was slow. Delay in sending ping packet was high, and

Data Products

17

April 2009

Issue 160

ZXR10#show interface fei_1/1 fei_1/1 is up, line protocol is up Description is none Keepalive set:10 sec The port is electric Duplex full Mdi type:auto VLAN mode is access, pvid 4094 BW 100000 Kbits Last clearing of "show interface" counters never 120 seconds input rate: 3403245 Bps, 3117 pps 120 seconds output rate: 1122389 Bps, 11912 pps Interface peak rate: input 8120382 Bps, output 12420382 Bps Interface utilization: input 29%, output 90% Input: Packets: 19028174612 Bytes: 24122478262892 Unicasts: 18709469101 Multicasts: 19281980 Broadcasts: 299188371 Undersize: 230911 Oversize: 3247 CRC-ERROR: 9 Dropped: 1091 Fragments: 0 Jabber: 1002 MacRxErr: 0 Output: Packets: 142123550101 Bytes: 182329420262394 Unicasts: 56909126342 Multicasts: 729262387 Broadcasts: 84485161372 Collision: 0 LateCollision: 0 Total: 64B: 772661029 65-127B: 803872612 128-255B: 1292984228 256-511B: 2374859862 512-1023B: 63467072821 1024-1518B: 92427412536

The above information showed that traffics on customer port in outgoing direction were large and it caused congestion. Engineers viewed traffic information on other interfaces. They found that traffics in outgoing direction of other interfaces were also large. 3. Engineers viewed traffics on uplink interface, as shown below. ZXR10#show interface gei_2/1 gei_2/1 is up, line protocol is up Description is none Keepalive set:10 sec The port is electric Duplex full Mdi type:auto VLAN mode is access, pvid 4094 BW 1000000 Kbits Last clearing of "show interface" counters never 120 seconds input rate : 29123012 Bps, 29081 pps 120 seconds output rate: 14133829 Bps, 13909 pps Interface peak rate : input : 50234251 Bps, output 5292182 Bps Interface utilization: input 28%, output 19% The above information showed that traffics on uplink port were normal. 4. Engineers viewed alarm information. No abnormal alarm was presented and no MAC floating alarm occurred. Therefore, it was not loop that caused broadcast storm. 5. Engineers analyzed configuration on the device. QinQ configuration is shown below. ZXR10(config)#show vlan qinq Session Customer Uplink In_Vlan Ovlan Helpvlan ---------------------------------------------------1 fei_1/1 gei_2/1 101-200 100 2 3 4 5 6 fei_1/2 gei_2/1 201-300 100 fei_1/3 gei_2/1 301-400 100 fei_1/4 gei_2/1 401-500 100 fei_1/5 gei_2/1 501-540 100 fei_1/6 gei_2/1 541-580 100

18

Maintenance Experience

www.zte.com.cn

Port configuration is shown below. ZXR10(config)#show run interface fei_1/1 description TO-DS01 no negotiation auto switchport mode hybrid switchport hybrid native vlan 4094 switchport hybrid vlan 99 tag switchport hybrid vlan 100 untag switchport hybrid vlan 3001-3010 tag switchport qinq customer ZXR10(config)#show run interface fei_1/2 description TO-DS02 no negotiation auto switchport mode hybrid switchport hybrid native vlan 4094 switchport hybrid vlan 99 tag switchport hybrid vlan 100 untag switchport hybrid vlan 3011-3020 tag switchport qinq customer ZXR10(config)#show run interface fei_2/1 description to-T64G no negotiation auto hybrid-attribute fiber switchport mode hybrid switchport hybrid native vlan 1 switchport hybrid vlan 99 tag switchport hybrid vlan 101-150 tag switchport hybrid vlan 3001-3500 tag switchport hybrid vlan 501-2500 tag switchport hybrid vlan 4094 untag switchport qinq uplink

With the above information results, engineers found that native VLAN on each port was Helpervlan 4094. Double-tagged services were implemented through VLAN QinQ. Therefore, MAC learning was in Helpervlan 4094, and the VLAN 100 would not learn MAC addresses. That is, packets in VLAN 100 were broadcasted to downstream devices. After asking the office personnel about services running, engineers knew that that there were a lot of double-tagged PPPOE services that were transparently transmitted. According to the plan, users were identified by inner tags and areas were identified by outer tags. Therefore, PPPoE service on ZXR10 3952 was only allocated with one outer tag vlan 100, and all ports were in this vlan. From above information, downstream PPPOE traffics were broadcasted in VLAN 100. Since the uplink port was 1000M and the downstream traffics were great, but customer port was 100M, downstream broadcast traffics were congested. This made internet surfing slow.

Solution
Engineers set the outer tag VLAN id to native VLAN id on customer port. The problem was solved.

Data Products

19

April 2009

Issue 160

Operational Failure through ACL


Zhang Fan / ZTE Corporation
Key words: ACL, ping, protocol protection

Malfunction Situation
As shown in Figure 1, ACL was applied on interface Fei_1/1 of ZXR10 3928 switch to forbid PC to ping to 3928. The configuration failed but still PC could ping 3928 successfully.

proved priority of ICMP packets through a set of special rules. These rules were placed ahead of ACL. ICMP was in protocol protection range. Protocol protected packet had a higher priority than ACL. As the value of parameter <profile-number> on ZXR10 3928 switch was 0 by default, the command of disabling ICMP became invalid. As a result, PC could still ping to ZXR10 3928 switch successfully.

Solution
Engineers modified the configuration of ZXR10 3928 switch, as shown below. acl extend number 101 rule 1 deny icmp 10.40.184.0 0.0.3.255 any rule 2 permit ip any any ! int fei_1/1 protpcol-protect mode icmp disable switchport access vlan 1 ip access-group 101 1 in //Set the value of parameter profile-number to 1, that is, protocolprotect is disabled

Figure 1. Network Topology

Malfunction Analysis
Engineers checked configuration of ZXR10 3928 switch, as shown below. acl extend number 101 rule 1 deny icmp 10.40.184.0 0.0.3.255 any rule 2 permit ip any any ! int fei_1/1 protpcol-protect mode icmp disable switchport access vlan 1 ip access-group 101 0 in The command to apply ACL is shown below: ip access-group <acl-number> <profile-number> in In this command, parameter<profile-number> is required. The value is 0 or 1. 0 indicates that protocol protection is enabled and 1 indicates protocol protection is disabled. Protocol protection is enabled by default on interface, that is, the default value of <profile-number> is 0. After protocol protection function was enabled, switch im-

Experience Summary
For downlink interface where SVLAN is enabled, the value of parameter <profile-number> must be 1. When protocol protection is enabled, the value of parameter <profile-number> must be 0. When a switch is used as L2 device, then value of parameter<profile-number> is allowed to be 1. However, in this situation, some control packets will fail to be received on the interface and some protocol calculations will be wrong. Therefore, set the value of parameter <profile-number> to 0.

20

Maintenance Experience

www.zte.com.cn

Abnormal EBGP Neighborhood Establishment


Xia Ying / ZTE Corporation
Key words: EBGP, neighbor

Network Topology
IBGP protocol runs between T1200-1 and T1200-2. EBGP runs between T1200-1 and T128-1. EBGP runs between T1200-2 and T128-2. IBGP protocol runs between T128-1 and T128-2. IBGP and OSPF run between 128 and T64. The network topology is shown in Figure 1. ip address 10.0.0.5 255.255.255.252 router bgp 4809 neighbor 3.3.3.3 remote-as 65514 // Designated EBGP neighbor neighbor 3.3.3.3 activate neighbor 3.3.3.3 update-source loopback1 neighbor 3.3.3.3 ebgp-multihop neighbor 10.0.0.2 remote-as 4809 // Designated IBGP neighbor neighbor 10.0.0.2 activate Configuration of T1200-2: interface loopback1 ip address 2.2.2.2 255.255.255.255 interface pos48_1/1 ip address 10.0.0.2 255.255.255.252
Figure 1. Network Topology

interface pos48_2/1 ip address 10.0.0.9 255.255.255.252 router bgp 4809 neighbor 4.4.4.4 remote-as 65514 // Designated EBGP neighbor neighbor 4.4.4.4 activate neighbor 4.4.4.4 update-source loopback1 neighbor 4.4.4.4 ebgp-multihop neighbor 10.0.0.1 remote-as 4809 // Designated IBGP neighbor neighbor 10.0.0.1 activate

Malfunction Situation
Device configurations are shown below. Configuration of T1200-1: interface loopback1 ip address 1.1.1.1 255.255.255.255 interface pos48_1/1 ip address 10.0.0.1 255.255.255.252 interface pos48_2/1

Data Products

21

April 2009

Issue 160

Configuration of T128-1: interface loopback1 ip address 3.3.3.3 255.255.255.255 interface pos48_1/1 ip address 10.0.0.6 255.255.255.252 interface gei_2/1 ip address 10.10.10.1 255.255.255.252 interface gei_3/1 ip address 10.10.10.5 255.255.255.252 router ospf 100 // Starting OSPF process network 3.3.3.3 0.0.0.0 area 0.0.0.0 network 10.10.10.0 0.0.0.3 area 0.0.0.0 network 10.10.10.4 0.0.0.3 area 0.0.0.0 router bgp 65514 neighbor 1.1.1.1 remote-as 4809 // Designated EBGP neighbor neighbor 1.1.1.1 activate neighbor 1.1.1.1 update-source loopback1 neighbor 1.1.1.1 ebgp-multihop neighbor 4.4.4.4 remote-as 65514 // Designated IBGP neighbor neighbor 4.4.4.4 activate neighbor 4.4.4.4 update-source loopback1 neighbor 5.5.5.5 remote-as 65514 neighbor 5.5.5.5 activate neighbor 5.5.5.5 update-source loopback1 Configuration of T128-2: interface loopback1 ip address 4.4.4.4 255.255.255.255 interface pos48_1/1 ip address 10.0.0.10 255.255.255.252 interface gei_2/1 ip address 10.10.10.2 255.255.255.252 interface gei_3/1 ip address 10.10.10.9 255.255.255.252 router ospf 100 //Starting OSPF Process

network 4.4.4.4 0.0.0.0 area 0.0.0.0 network 10.10.10.0 0.0.0.3 area 0.0.0.0 network 10.10.10.8 0.0.0.3 area 0.0.0.0 router bgp 65514 neighbor 2.2.2.2 remote-as 4809 // Designated EBGP neighbor neighbor 2.2.2.2 activate neighbor 2.2.2.2 update-source loopback1 neighbor 2.2.2.2 ebgp-multihop neighbor 3.3.3.3 remote-as 65514 // Designated IBGP neighbor neighbor 3.3.3.3 activate neighbor 3.3.3.3 update-source loopback1 neighbor 6.6.6.6 remote-as 65514 neighbor 6.6.6.6 activate neighbor 6.6.6.6 update-source loopback1 Configuration of T64E-1: interface loopback1 ip address 5.5.5.5 255.255.255.255 interface gei_1/1 ip address 10.10.10.6 255.255.255.252 router ospf 100 //Starting OSPF Process network 5.5.5.5 0.0.0.0 area 0.0.0.0 network 10.10.10.4 0.0.0.3 area 0.0.0.0 router bgp 65514 neighbor 3.3.3.3 remote-as 65514 // Designated IBGP neighbor neighbor 3.3.3.3 activate neighbor 3.3.3.3 update-source loopback1 EBGP connection can not be established between T128-1 and T1200-1.

Malfunction Analysis
To find out the problem, engineers took the following steps. 1. Engineers viewed BGP neighbor information on T128-1, as shown below.

22

Maintenance Experience

www.zte.com.cn

T128-1#show ip bgp summary Neighbor Ver As MsgRcvd MsgSend Up/Down(s) State 1.1.1.1 4 4809 0 0 0h Connect 4.4.4.4 4 65514 255152 255339 13w1d2h Established 5.5.5.5 4 65514 27912 273892 1w1d20h Established 2. Engineers pinged to the neighbor with

Solution
Engineers added static routes on T1200-1 and T128-1. The static route configuration added to T1200-1 is shown below. T1200_1(config)#ip route 3.3.3.3 255.255.255.255 10.0.0.6 The static route configuration added to T128-1 is shown below. T128_1(config)#ip route 1.1.1.1 255.255.255.255 10.0.0.5 Engineers viewed neighbor information on T128-1, as shown below. T128-1#show ip bgp summary Neighbor Ver 1.1.1.1 4.4.4.4 5.5.5.5 4 4 4 As 4809 65514 65514 MsgRcvd 2230 264329 299126 MsgSend Up/Down(s) State 2221 265436 283898 1h 13w1d3h 1w1d21h Established Established Established

which the connection was established normally on T128-1, as shown below. T128-1#ping 4.4.4.4 sending 5,100-byte ICMP echos to 4.4.4.4,timeout is 2 seconds. !!!!! Success rate is 100 percent(5/5),round-trip min/avg/max=0/8/20ms 3. Engineers pinged to the neighbor with

which the connection was established abnormally on T128-1, as shown below. T128-1#ping 1.1.1.1 sending 5,100-byte ICMP echos to 1.1.1.1,timeout is 2 seconds. ..... Success rate is 0 percent(0/5) 4. Engineers viewed network segment route

In the same way, engineers added static routes on T128-2 and T1200-2. Therefore, the neighbor relationship can be established normally.

on T128-1, as shown below. show ip route 1.1.1.1 IPv4 Routing Table: Dest Mask Gw Interface Owner pri metric BGP route protocol sent protocol packets based on TCP protocol 179. It could be determined that the links were established unsuccessfully, because IP router was not reachable. It was necessary to add static routes between T128 and T1200.

Experience Summary
To configure EBGP interconnection and establish neighborhood by loopback address, the static route configuration can not be neglected. Additionally, the command neighbor <ip-address> ebgp-multihop is necessary to establish EBGP with loopback addresses.

Data Products

23

April 2009

Issue 160

Telnet with Slow Speed


Xin Chang / ZTE Corporation
Key words: telnet, slow speed

Network Topology
Network topology is shown in Figure 1. OSPF protocol is enabled between T160G and T64G.

Malfunction Description
Users could telnet T160G-1 remotely and everything went smoothly. When users telnet T64G in another HMS node from T160G-1, the response speed was quite slow and no reaction showed after users input username and password. But it was successful to ping T64G from T160-1. In addition, there was no user service fault.
Figure 1. Network Topology

ZXR10 T160G and T64G are used in an IPTV bearer network of a carrier. IPTV program source of this carrier is provided by TV station through GE leased line. It is planned to draw two gigabit links from TV station to two sets of T160G in central node and at present only one gigabit link is drawn to T160G-1. CX part of IPTV platform needs to receive program source of TV station directly. At present, GW of CX is the VRRP virtual address of T160G and multicast flow of TV station is imported to CX through T160G. After receiving SMG program source, CX translates and processes the program source and sends it out in mode of multicast (source IP and multicast IP address is translated to local address). Central MD&ME receives multicast flow sent from CX through two sets of T160G in central node, and edge HMS system receives the flow from T160G by edge T64G. Programs watched by users are provided by MD&ME in different places.

Malfunction Analysis
To find out the problem, engineers took the following steps. 1. The speed of Telnet being slow may be because the main board CUP of T64G was high or CPU of line card where interconnected interface locates was high. After accessing T64G, engineers executed command show processor to view CPU utilizations of the main board and line interface cards, as shown below. T64G-1#show processor M: Master processor S: Slave processor Peak CPU: CPU peak utility measured in 2 minutes PhyMem: Physical memory (megabyte) Panel CPU(5s) CPU(30s) CPU(2m) Peak 23% 8% 12% 11% 12% 23% 8% 12% 11% 12% 58% 13% 18% 33% 34% CPU 512 512 256 256 128 PhyMem Memory 38.106% 19.578% 37.700% 37.674% 54.977% MP(M)1 23% MP(S)2 8% NP(M)1 12% NP(M)2 11% NP(M)4 12%

24

Maintenance Experience

www.zte.com.cn

CPU 5s of master MP is 23%, which was in normal range (in case CPU 5s exceeds 40%, it indicates there is something wrong. 30% is normal when there are large service traffics). By analyzing CPU, the previous judgments were wrong. It was necessary to find out the problem from other aspects. 2. It may be the problem of T160G-1 itself, for example, CPU of the main board was high or corresponding line interface card CPU was high, which led to that message queue was completely occupied by other packets transmitted to CPU and therefore telnet packets were dropped. Engineers executed command show processor on T160G-1 to view CPU utilizations of the main board and line interface cards, as shown below. T160G-1#show processor M: Master processor S: Slave processor Peak CPU: CPU peak utility measured in 2 minutes PhyMem: Physical memory (megabyte) Panel CPU(5s)CPU(30s) CPU(2m) Peak 35% 8% 37% 12% 15% 15% 15% 23% 13% 36% 8% 38% 13% 16% 15% 15% 23% 13% 43% 12% 39% 17% 19% 15% 19% 27% 14% CPU 512 512 256 256 128 128 128 128 128 PhyMem Memory 38.164% 19.578% 36.105% 36.105% 54.055% 54.055% 54.055% 54.056% 50.971% MP(M)1 37% MP(S)2 8% NP(M)1 37% NP(M)2 13% NP(M)3 15% NP(M)4 14% NP(M)5 14% NP(M)6 23% NP(M)7 14%

telned to T64G through T160G-2. The response speed was normal. Engineers checked CPU of line interface card 1 on T160G-2, it was normal. It could be assumed that the fault was related to high CPU utilization of line interface card 1 on T160G-1. 3. The reason for line interface card 1 CPU being high was that there were large numbers of packets being up-sent to line interface card CPU. They may be protocol packets or ordinary packets. When engineers executed command show logging alarm, it was found that there was no alarm for receiving a large number of protocol packets. Therefore, the packets may not be protocol packets. It was assumed that it was service packets that flooded CPU. Engineers executed command capture npc 1 readspeed 20 on T160G-1 to capture packets to line card 1. The result was shown below. T160G-1(config)#capture npc 1 readspeed 20 IP Packet on NPC: 1 DST_IP 10.0.9.123 10.0.9.123 10.0.9.123 10.0.9.123 10.0.9.123 233.20.204.4 233.20.204.4 10.0.9.123 10.0.9.123 233.20.204.4 233.20.204.4 PDST_IP 10.0.9.123 SRC_IP 10.107.25.122 10.113.35.122 10.137.26.69 10.133.0.122 10.119.45.123 ovid 9 100 9 9 9 9 ivid NULL NULL NULL NULL NULL NULL NULL NULL NULL NULL NULL NULL ivid NULL NULL ivid NULL NULL TTL 61 7 61 61 61 61 7 7 61 61 7 7 TTL 61 7 TTL 61 61 PRO 6 17 6 6 6 6 17 17 6 6 17 17 PRO 6 17 PRO 6 6 DIR RX RX RX RX RX RX RX RX RX RX RX RX DIR RX RX DIR RX RX Port 4 12 2 1 1 2 12 12 6 5 12 12 Port 2 12 Port 1 2

233.18.204.166 124.108.15.105

124.108.15.100 100 124.108.15.100 100 10.146.22.61 10.124.122.77 9 9

CPU of master main board was fairly high and CPU utilization of line interface card 1 was particularly higher than those of other line interface cards. All edge nodes T64G were connected to line interface card 1 of T160G-1, except for T160G-2 (connected to line interface cards 3 and 4). If CPU utilization of line interface card 1 was too high, the peed of accessing all T64G switches (except for T160G-2) would be slow. Engineers validated this assumption, it was correct. To perform further validation, engineers connected all edge nodes T64G to line interface card 1 of T160G-2, and then

124.108.15.100 100 124.108.15.100 100 SRC_IP 10.115.5.123 ovid 9

IP Packet on NPC: 1

233.20.204.17 124.108.15.100 100 IP Packet on NPC: 1 DST_IP 10.0.9.123 10.0.9.123 SRC_IP 10.113.36.110 ovid 9 10.129.140.120 9

Data Products

25

April 2009

Issue 160

10.0.9.123

10.119.97.39

NULL NULL NULL NULL NULL NULL NULL NULL NULL NULL

61 7 7 7 7 7 61 7 61 7

6 17 17 17 17 17 6 17 6 17

RX RX RX RX RX RX RX RX RX RX

2 12 12 12 12 12 2 12 4 12

is made clear, it can be known that which line card corresponds to which slot uniquely. In usual cases, there could not be many multicast service packets up-sent to line interface card CPU. Therefore, it was assumed that there was something wrong with multicast routing table. 4. According to the above analysis result, engineers executed command show ip mroute to view multicast routing table. Group 233.18.204.166 was one of the multicast group addresses of CPU captured packets. Take it for example here for analysis. T160G-1(config)#show ip mroute group 223.18.204.166 IP Multicast Routing Table Flags:D-Dense,S-Sparse,C-Connected,L-Local,P-Pruned, R-RP-bit set,F-Register flag,T-SPT-bit set,J-Join SPT, M-MSDP created entry,N-No Used,U-Up Send, A-Advertised via MSDP,X-Proxy Join Timer Running, *-Assert flag Statistic:Receive packet count/Send packet count Timers:Uptime/Expires Interface state:Interface,Next-Hop or VCD,State/Mode (*,233.18.204.166),1d1h/00:03:34,RP 124.108.8.3, 150295/150295,flags:SC Incoming interface: vlan100, RPF nbr 10.0.100.1 Outgoing interface list: vlan40, Forward/Sparse, 1d1h/00:03:29 C By executing command show ip mroute group 233.18.204.166 repeatedly, It was found that only (*, g) entry was in this multicast table, and there was no (s, g) entry. Packet sending/receiving count of (*,g) entry (150295/150295) increased continuously. Multicast data flow were forwarded according to (*, g) entry and packets forwarded according to (*, g) entry were be up-sent to CPU for processing, which led to high CPU. Note: Packets forwarded according to (s,g) entry are processed by hardware directly. 5. Engineers continued to analyze the reason why entry (s, g) was unavailable in multicast routing table.

233.20.204.32 124.108.15.102 100 233.20.204.32 124.108.15.102 100 233.20.204.32 124.108.15.102 100 233.20.204.32 124.108.15.102 100 233.20.204.32 124.108.15.102 100 10.0.9.123 233.20.204.4 10.0.9.123 233.20.204.4 10.115.66.108 10.127.3.12 9 9 124.108.15.100 100 124.108.15.100 100

Engineers analyzed the result of packet capture (take one packet for example), as shown below. IP Packet on NPC: 1 DST_IP SRC_IP ovid ivid NULL TTL PRO 7 17 DIR Port RX 12 233.20.204.17 124.108.15.100 100

The following parameters were concerned.

DST_IP, SRC_IP: Destination IP and source IP of a packet; all packets captured by command capture must be up-sent to line card CPU. Large number of multicast service packets (with destination address beginning with 233) and a few unicast packets (with destination address to be 10.0.9.123) are found in CPU packet capture on slot 1.

Ovid: Outer VLAN tag of the packet. It can be seen that it is fixed that all multicast packets are up-sent to CPU through vlan100 and all unicast packets are sent to CPU through vlan9.

TTL: TTL value of the packet. It is normal as long as the value is not 1. DIR: Direction of the packet, in receiving direction or sending direction. For receiving direction, it is RX, indicating the packet is up-sent to CPU and for sending direction, it is TX, indicating the packet is sent out from CPU

Port: The physical interface to receive (send) a packet. As slot number has been specified in command, so as long the physical interface

26

Maintenance Experience

www.zte.com.cn

In normal cases, entry (s,g) could generate as long as multicast data flow was available and DR knew IP address of multicast source and RPT was switched to SPT. If (s,g) entry faied to be generated, users could execute command show ip rpf to view whether RPF check is passed. When an interface on the switch receives multicast packet sent from a multicast source. if the path from switch to this multicast source actually passes through this interface according to the routing table of this switch, RPF check is passed. Engineers continued to analyze the result of CPU packet capture, as shown below. T160G-1#show ip rpf 124.108.15.105 RPF information: RPF interface vlan501 RPF neighbor 61.154.120.201 (isnt neighbor) RPF metric preference 1 RPF metric value 0 RPF type : unicast Engineers analyzed the result of reverse path check. Outgoing interface to multicast source 124.108.15.105 was 61.154.120.201 (line interface card 7, vlan 501, default route); with CPU packet capture it was found that packets whose multicast group address was 233.18.204.166 were forwarded from interface 12 of line interface card 1. Therefore, RPF check is not passed and entry (s,g) could not be generated. 6. card. i. ii. Configure ACL to filter these multicast Configure a static route to enable the route packets. to 124.108.15.105 pass through interface 12 of line card 1 and thus RPF check is passed. Since the group 233.18.204.166 was used for forwarding multicast service, static route was configured here so that RPF check could pass. Configuration of static route was shown below. With the above analysis, there were two ways to decrease CPU utilization of line interface

ip route 124.108.15.0 255.255.255.0 10.0.100.1 After static route was configured, engineers performed RPF check. The information was shown below. T160G-1#show ip rpf 124.108.15.105 RPF information: RPF interface vlan100 pimsm RPF neighbor 10.0.100.1 (is neighbor) RPF metric preference 1 RPF metric value 0 RPF type : unicast According to the RPF check, it was found that the interface belonged to vlan100, where there was only one interface gei_1/12 and it was neighbor. RPF check was passed. By executing command show ip mroute, it was found that (s,g) entry was generated and data flow could be forwarded according to (s, g) entry rather than according to (*.g). T160G-1#show ip mroute group 233.18.204.166 IP Multicast Routing Table Flags:D-Dense,S-Sparse,CConnected,L-Local,P-Pruned, R-RP-bit set,F-Register flag,T-SPT-bit set,J-Join SPT, M-MSDP created entry,N-No Used,UUp Send, A-Advertised via MSDP,X-Proxy Join Timer Running, *-Assert flag Statistic:Receive packet count/Send packet count Timers:Uptime/Expires Interface state:Interface,Next-Hop or VCD,State/Mode

Data Products

27

April 2009

Issue 160

(*, 233.18.204.166), 1d2h/00:02:48, RP 124.108.8.3, 150385/150385, flags: SC Incoming interface: vlan100, RPF nbr 10.0.100.1 Outgoing interface list: vlan40, Forward/Sparse, 1d2h/00:02:43 C (124.108.15.105, 233.18.204.166), 00:44:39/00:02:48 , 6340/6340 , flags: CJT Incoming interface: vlan100, RPF nbr 10.0.100.1 Outgoing interface list: vlan40, Forward/Sparse, 00:44:39/00:02:43 C By executing command show ip mroute group repeatedly to compare packet sending/receiving counts, it was verified that data flow were forwarded according to (s,g)

entry rather than according to (*.g). Engineers executed command show processor to view CPU utilization of line interface card and it was found that it increased rather than decreases. It was normal for T160G-1 to telnet the other T64Gs connected to it.

Experience Summary
In normal cases, as for each group, there were two entries available in multicast routing table, (s,g) and (*,g). Both are indispensable. If either of the two entries does not exist or it is abnormal, it is necessary to analyze the reason. Packets forwarded according to (s,g) are processed by hardware and packets forwarded according to (*,g) are processed by software. In normal cases, when device receives multicast data flow for the first time, the device forwards it according to (*,g) and it will implement SPT changeover immediately to generate (s,g) entry, and then forward the multicast data flow by hardware.