0% found this document useful (0 votes)
15 views2 pages

Analisis IBA

The document contains data from an IBA analysis performed on January 26, 2025, detailing various electrical parameters over a 600-second period. Key metrics include voltage, current, and operational status of TCR (Thyristor Controlled Reactor) with specific values for each signal. The analysis provides insights into the performance and operational state of the electrical system during the specified time frame.

Uploaded by

DARIO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
15 views2 pages

Analisis IBA

The document contains data from an IBA analysis performed on January 26, 2025, detailing various electrical parameters over a 600-second period. Key metrics include voltage, current, and operational status of TCR (Thyristor Controlled Reactor) with specific values for each signal. The analysis provides insights into the performance and operational state of the electrical system during the specified time frame.

Uploaded by

DARIO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

ibaAnalyzer D:\Data\Dat2_cont\250126\cont_2025-01-26_08.30.47.

dat IBA
12.5 I0 TCR Line SWG
I0 TCR Line Yard
10.0

7.5

5.0

2.5
sec
0

5.5 I0 Main Incomer 1


5.0 I0 Main Incomer 2
I0 Main Incomer 3
4.5 I0 Main Incomer 4
4.0 08:32:22.70 sec
3.5
3.0
2.5
2.0
1.5
1.0 sec
0.5

45 X1-AI01_TDC Q_TCR (Mvar)


40 08:32:23.19 sec
35
30
25
20
15
10
5 sec
0

TDC is ON (feeder) 08:32:23.37 sec


TCR is ON (operation) 08:32:23.67 sec
TCR alarm (general alarm)
TCR Fault trip

sec

24 Voltage rms U12 (kV)


Voltage rms U23 (kV)
22 Voltage rms U31 (kV)
20

18
sec
16

3000 Current TCR Delta Ph1-2 (A)


Current TCR Delta Ph2-3 (A)
2000 Current TCR Delta Ph3-1 (A)
1000
0
-1000
sec
-2000 08:32:22 08:32:23
08:32:22 08:32:23 08:32:24 08:32:25 08:32:26 08:32:27 08:32:28

1/2
ibaAnalyzer D:\Data\Dat2_cont\250126\cont_2025-01-26_08.30.47.dat IBA
File 0: D:\Data\Dat2_cont\250126\cont_2025-01-26_08.30.47.dat
Starttime: 26.01.2025 08:30:47
File time: 600.000 sec
Sampling time: 0.000 sec

SignalName X1 X2 Min Max Average Std dev Unit


1 I0 TCR Line SWG 08:32:22.66 08:32:23.51 0.824 2.321 1.4146 0.3762
2 I0 TCR Line Yard 08:32:22.66 08:32:23.51 2.747 13.596 8.5780 3.6383
3 I0 Main Incomer 1 08:32:22.66 08:32:23.51 1.609 5.801 2.7693 1.0357
4 I0 Main Incomer 2 08:32:22.66 08:32:23.51 1.030 1.969 1.3358 0.2560
5 I0 Main Incomer 3 08:32:22.66 08:32:23.51 0.759 1.327 0.9982 0.1389
6 I0 Main Incomer 4 08:32:22.66 08:32:23.51 1.391 3.609 2.1477 0.6029
7 X1-AI01_TDC Q_TCR 08:32:22.66 08:32:23.51 8.82 48.38 29.770 12.409 Mvar
8 TDC is ON (feeder) 08:32:22.66 08:32:23.51 0.00 1.00 0.847 0.361
9 TCR is ON (operation) 08:32:22.66 08:32:23.51 0.00 1.00 0.835 0.372
10 TCR alarm (general alarm) 08:32:22.66 08:32:23.51 0.00 0.00 0.000 0.000
11 TCR Fault trip 08:32:22.66 08:32:23.51 0.00 0.00 0.000 0.000
12 Voltage rms U12 08:32:22.66 08:32:23.51 16.23 23.16 19.587 2.927 kV
13 Voltage rms U23 08:32:22.66 08:32:23.51 15.72 23.18 19.248 3.285 kV
14 Voltage rms U31 08:32:22.66 08:32:23.51 17.65 23.23 20.474 2.285 kV
15 Current TCR Delta Ph1-2 08:32:22.66 08:32:23.51 -1708.88 1691.58 -2.468 746.141 A
16 Current TCR Delta Ph2-3 08:32:22.66 08:32:23.51 -1663.97 1725.36 3.254 741.943 A
17 Current TCR Delta Ph3-1 08:32:22.66 08:32:23.51 -1789.22 1723.44 3.665 673.372 A

2/2