MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS

Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 2 of 22

REVISION LIST SECTION REV DATE


00 B0 16/11/2010 02/03/2011

DESCRIPTION OF AMENDMENT
ISSUED FOR APPROVAL ISSUED FOR ORDER

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 3 of 22

CONTENTS

1 2 3 4 5 6 7 8 9 10

GENERAL ................................................................................................................. 4 DEFINITION OF TERMS.......................................................................................... 4 SCOPE OF SUPPLY .................................................................................................. 4 GENERAL REQUIREMENT..................................................................................155 PRECEDENCE ........................................................................................................ 17 VENDOR DOCUMENT REQUIREMENT .............................................................. 17 PROCUREMENT PLAN.......................................................................................... 18 QUALITY REQUIREMENT.................................................................................... 18 SPARE REQUIREMENTS......................................................................................188 PERFORMANCE & WARRANTEE / GUARANTEE. ..........................................2020

11 SPECIAL REQUIREMENT.20Error! Bookmark not defined. 12 13 DEFECTS LIABILITY .........................................................................................2121 APPLICABLE DOCUMENTS ..............................................................................2121

Annexure -1 (Local Control Station Name plate details) Rev C0

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 4 of 22

GENERAL Petrovietnam Central Bio-fuel Joint Stock Company proposes to built the Dung Quat Biofuels Ethanol plant to supply high quality Bio-Ethanol to blend with gasoline for production. The plant is located in an area of 24 ha in Dung Quat Economic zone with other industrial projects including Dung Quat refinery . The Plant will be of high environmental standard, respecting all Vietnamese safety, Health standard and laws. Alfa laval India ltd (ALIL) through APTI is process Licensor. PTSC Quang Ngai Co. Ltd is nominated as an EPC contractor (hereinafter referred to as contractor) for Engineering, Procurement, Construction, and Commissioning for Dung Quat Bio-Ethanol plant project in Quang Ngai Province, S.R Vietnam (hereinafter called as Project). PTSC Quang Ngai Co. Ltd has appointed Aker Powergas Pvt. Ltd Pune as a Detailed Design & Engineering contractor for Balance of Plant (herein after referred as BOP)

DEFINITION OF TERMS OWNER: Petro Vietnam Central Biofuel Joint stock Company. CONTRACTOR: PTSC Quang Ngai Co. Ltd / Aker Powergas Pvt. Ltd Pune . PROJECT: Dung Quat Bio-Ethanol plant. VENDOR: Supplier of equipments and other accessories mentioned in this MR / Technical Specification. MR: Material Requisition APVL : Approved Project Vendor List

SCOPE OF SUPPLY This MR is for Balance of Plant (BOP) only Contractor is planning to procure Industrial and Flameproof Local control stations and Light Fittings. Technical details are described in following documents. 1) Specification for Flameproof and Industrial Local control Stations (LCS), doc. no. 8455001-007-SP-0013.

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 5 of 22

2) Specification for Industrial and flameproof Type Light fittings, doc. no. 8455001-007-SP-0016. . A) MTO FOR LOCAL CONTROL STATIONS (LCS) A.1) Industrial type LCS / Push Button Stations Sr. No 1 2 3 4 5 6 Type of PB Station (refer scheme) SAAO SACO SALO SAHO SABO SAVO Description of LCS/Push Button Station Type Industrial Start/Stop Push Button Station Industrial Start/Stop Push Button Station with Ammeter (refer annexure-1 for details of Ammeter) Industrial Start/Stop Push Button Station with Local - Remote selector switch Industrial Start/Stop Push Button Station with Local -Remote selector switch and Ammeter Industrial Stop Push Button Station Industrial Stop Push Button Station with Ammeter Cable size (C=Core) 4C x 2.5sqmm. cu. Arm. 6C x 2.5sqmm. cu. Arm 6C x 2.5sqmm. cu. Arm 10C x 2.5sqmm. cu. Arm 3C x 2.5sqmm. cu. Arm 4C x 2.5sqmm. cu. Arm Quantity (Nos.) 33 12 Unit Rate Unit Rate 18 Unit Rate

A.2) Flameproof type LCS / Push Button Stations Vendor to supply all Flameproof LCS with Atex/Baseefa certification
LCS type for Hazardous area shall be as below: a. For Zone 1 EEx d b. For Zone 2 EEx d OR EExde

Sr. No 1

Type of PB Station (refer scheme) F2AO

Description of LCS/Push Button Station Type Start/Stop Push Button Station suitable for Zone-2, IIA/IIB, Temp. class - T3 as per IEC. Start/Stop Push Button Station with Ammeter for Zone-2, IIA/IIB, Temp. class - T3 as per IEC. (refer annexure-1 for details of Ammeter)

Cable size (C=Core) 4C x 2.5sqmm. cu. Arm. 6C x 2.5sqmm. cu. Arm

Quantity (Nos.) 27

F2CO

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 6 of 22

F2LO

4 5 6

F2HO F2BO F2VO

Start/Stop Push Button Station with Local Remote selector switch for Zone-2, IIA/IIB, Temp. class - T3 as per IEC. Start/Stop Push Button Station with Local Remote selector switch and Ammeter for Zone-2, IIA/IIB, Temp. class - T3 as per IEC. Stop Push Button Station for Zone-2, IIA/IIB, Temp. class - T3 as per IEC. Stop Push Button Station with Ammeter for Zone-2, IIA/IIB, Temp. class - T3 as per IEC.

6C x 2.5sqmm. cu. Arm 10C x 2.5sqmm. cu. Arm 3C x 2.5sqmm. cu. Arm 4C x 2.5sqmm. cu. Arm

Unit Rate

Unit Rate Unit Rate Unit Rate

Notes to Vendor for Industrial and Flameproof LCS 1 Local control station quantity is based on inputs received from Mechanical / Package vendor. 2. Vendor shall provide cable glands and end plug for Local control station as mentioned in specification. Gland/end plug Gland sizes shall be as per cable sizes mentioned in above cable sizes 3. Refer Specification Scheme for wiring details. 4. Canopy shall be provided for all LCS as per specification. 5. Unit rate shall be furnished by Vendor. 6. Vendor to furnish detail catalogue of LCS.

A.3) Flameproof type Welding socket / Receptacle / Junction box Vendor to supply all Flameproof Welding socket / Receptacle / Junction box with Atex/ Baseefa certification. Sr. No Description Welding Receptacle - Flameproof Ex'd' type (Zone-2, Gas group IIA/IIB, Temp. class T3 as per IEC), 400V, 63A, 50Hz, TPN, IP65, 5 pin type Three phase 100mA ELMCB along with plug complete with interlocked isolators socket outlet heavy duty type complying with requirements of IEC 60309, suitable for mounting on walls / columns. Welding Receptacle shall have loop-in-loop-out facility (2nos. of cable ET entries & looping terminals) suitable for 4Cx25sq.mm Cu/XLPE/SWA/PVC cable. 2 nos FLP Cable glands for each socket shall be supplied by vendor also MS/FRP powder coated canopy (RAL 7032) shall be supplied. Single phase receptacle- Flameproof Ex'd' type (Zone-2, Gas group IIA/IIB, Temp. class T3 as per IEC), 230V, 16A, 50Hz, 3 pin type single phase 30mA DP ELMCB along with plug complete with interlocked isolators socket outlet heavy duty type complying with requirements of IEC 60309, suitable for mounting on Quantity (Nos.)

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 7 of 22

3.

walls / columns. Receptacle shall have loop-in-loop-out facility (2nos. of cable ET entries & looping terminals) suitable for 3Cx4sq.mm Cu/XLPE/SWA/PVC cable. 2 nos FLP Cable glands for each socket shall be supplied by vendor also MS/FRP powder coated canopy (RAL 7032) shall be supplied. 4 Way Lighting Junction Box - Increased safety type - Ex'e' type (Zone-2, Gas group IIA/IIB, Temp. class T3 as per IEC), suitable for 230V, 10A, 50Hz. 4 Way 3/4" with ET entry Increased safety Ex 'e' type single phase JB die cast aluminium/FRP material terminals suitable for 3C x2.5sqmm. Cu XLPE/SWA/PVC armoured cable and feasible to mount on structures / columns / wall, for lighting circuit distribution. (Vendor shall supply 3 cable glands and 1 no. end plug along with each JB) 4 Way Lighting Junction Box - Flameproof Ex'd' type (Zone-1, Gas group IIA/IIB, Temp. class T3 as per IEC), suitable for 230V, 10A, 50Hz. 4 Way 3/4" with ET entry Ex 'd' type single phase JB die cast aluminium/FRP material terminals suitable for 3C x2.5sqmm. Cu XLPE/SWA/PVC armoured cable and feasible to mount on structures / columns / wall, for lighting circuit distribution. . (Vendor shall supply 3 cable glands and 1 no. end plug along with each JB) 1 no. switch (DP MCB) in Flameproof enclosure - Ex'd' type (Zone-2, Gas group IIA/IIB, Temp. class T3 as per IEC), 230V, 16A, 50Hz, shall have loop-inloop-out facility (2nos. of cable ET entries & looping terminals) suitable for 3Cx2.5sq.mm Cu/XLPE/SWA/PVC cable. 2 nos FLP Cable glands for each socket shall be supplied by vendor also MS/FRP powder coated canopy (RAL 7032) shall be supplied. For lighting switch

14

Notes to Vendor 1. Vendor shall provide cable glands and end plug as mentioned. Gland/end plug Gland sizes shall be as per cable sizes mentioned above. 2. Vendor to furnish detail catalogue of LCS.

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 8 of 22

B) MTO FOR LIGHT FITTINGS B.1) Industrial type Light Fittings (Along with lamps) Sr. no. 1 Vendor Model No. Actual Qtys. Spare Qtys. Final Quantity

LIGHT FITTING DESCRIPTION Fluorescent Light Fitting 4x18 W, Recess mounted Fluorescent Light fitting, mirror optic and Anti glare luminaries suitable for FTL (T8), LxW (600mmx600m) 4x18 W, Recess mounted Fluorescent Light fitting , mirror optic and Anti glare luminaries and inbuilt battery pack (Ni- Cad) for 60min back up suitable for FTL (T8), LxW (600mmx600m) 4x18 W, Recess mounted Fluorescent Light fitting, mirror optic luminaries suitable for FTL (T8), LxW (600mmx600m) 4x18 W, Recess mounted Fluorescent Light fitting , mirror optic luminaries and inbuilt battery pack (Ni- Cad) for 60min back up suitable for FTL (T8), LxW (600mmx600m) 2 x 36 W, Industrial Fluorescent Light fitting with stove enameled reflector suitable for FTL (T8) (wall/Suspended mounting) 2 x 36 W,Industrial Fluorescent Light fitting with stove enameled reflector and inbuilt battery pack (Ni-cad) for 60min back up suitable for FTL (T8) (wall/Suspended mounting) 2 x 36 W, Industrial Fluorescent Light fitting with polycarbonate cover and reflector suitable for FTL (T8) (suitable for Suspended/wall mounting) suitable for FTL (T8) (suitable for Suspended/wall mounting) 2 x 36 W, Industrial Fluorescent Light fitting with polycarbonate cover ,inbuilt battery pack (Ni- cad) for 60min back up and reflector suitable for FTL (T8) (suitable for Suspended/wall mounting) 2 x 36 W, Industrial Fluorescent Light fitting with corrosion proof and reflector suitable for FTL (T8) (suitable for Suspended/wall mounting)

90

93

24

26

10

10

131

135

41

43

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 9 of 22

Sr. no. 10

LIGHT FITTING DESCRIPTION 2 x 36 W, Industrial Fluorescent Light fitting with corrosion proof and inbuilt battery pack (Ni-cad) for 60min back up and reflector suitable for FTL (T8) (suitable for Suspended/wall mounting) 2x36 W, Recess mounted Fluorescent Light fitting, mirror optic and anti glare luminaries suitable for FTL (T8), 2x36 W, Recess mounted Fluorescent Light fitting , mirror optic and anti glare luminaries and inbuilt battery pack (NiCad) for 60min back up suitable for FTL (T8) 2x36 W, Recess mounted Fluorescent Light fitting, mirror optic luminaries suitable for FTL (T8) 2x36 W, Recess mounted Fluorescent Light fitting , mirror optic luminaries and inbuilt battery pack (Ni- Cad) for 60min back up suitable for FTL (T8), Well Glass light fitting

Vendor Model No. *

Actual Qtys. Unit rate Unit rate Unit rate Unit rate Unit rate

Spare Qtys.

Final Quantity

Unit rate

11 12

Unit rate

Unit rate

13 14

* *

Unit rate Unit rate

1 2 3

Integral Well Glass light fitting with 70W Metal Halide lamp (E) IP65 (suitable for Suspended/bracket mounting) Integral Well Glass light fitting with 70W Metal Halide lamp (E) IP65 (suitable for Pole mounting) Integral Well Glass light fitting with 150W Metal Halide lamp (E) IP65 (suitable for Suspended mounting) High / Mid bay light fitting Integral 1x150W Metal Halide (E) with control gear box, enclosed Mid bay Luminaries with aluminum reflector, U hook for suspension mounting Integral 1x250W Metal Halide (E), with control gear box enclosed Mid bay Luminaries with aluminum reflector, U hook for suspension mounting Non - Integral 1x400W Metal Halide (E), enclosed high bay Luminaries wide beam with aluminum reflector, U hook for suspension mounting

* * *

101 98 Unit rate

4 4 -

105 102 Unit rate

32

36

13

14

Unit rate

Unit rate

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 10 of 22

Sr. no. 1

LIGHT FITTING DESCRIPTION Flood light Fitting Non - Integral Symmetric (wide) beam Flood light fitting with control gear box 1x250W MH lamp (E), Suitable for Bracket mounting, IP65 Non - Integral Symmetric (wide beam) Flood light fitting with control gear box 1x 400W MH lamp (E), Suitable for Bracket mounting, IP65 Other Light Fitting

Vendor Model No.

Actual Qtys.

Spare Qtys.

Final Quantity

Unit rate 2

4 (const. work)

Unit rate

Bulk head CFL / GLS Light Fitting with inbuilt battery pack (Ni-cad) for 60min back up. (Suitable for Suspended/wall mounting) IP-65 2x30 watt Aviation / AIR CRAFT WARNING light fitting with NEON lamp as per ICAO Regulations 6VA, 230V, Ni-Cad 60 min Battery Backup with lamp LED for EXIT SIGN 230V, 60W GLS Vessel lamp with switch 230V, 60W GLS Hand Lamp with wire mesh and 20 meters trailing cable and socket

Unit rate Unit rate 22 Unit rate Unit rate

Unit rate

2 3 4 5

* * * *

3 -

Unit rate 25 Unit rate Unit rate

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 11 of 22

B.2) Increased Safety type Light Fittings (Ex e) (Along with lamps) Vendor to supply all Increased safety Light fitting with Atex/Baseefa certification SUITABLE FOR ZONE -2, IIA/IIB, TEMP CLASS T3 SR No. 1 Vendor Model No. Actual Qtys. Spare Qtys. Final Quantity

LIGHT FITTING DESCRIPTION Increased safety Well Glass light fitting Integral Well Glass Increased safety Ex"e" light fitting for area classification Zone 2, Gas gr IIB,T3 with 70W Metal Halide lamp (E),IP-65 (suitable for Suspended/wall mounting) Integral Well Glass Increased safety Ex"e" light fitting for area classification Zone 2, Gas gr IIB,T3 with 70W Metal Halide lamp (E),IP-65 (suitable for Pole mounting) Integral Well Glass Increased safety Ex"e" light fitting for area classification Zone 2, Gas gr IIB,T3 with 150W Metal Halide lamp (E),IP-65 (suitable for Suspended/wall mounting) Increased safety High / Mid bay light fitting Increased safety Non - Integral 1x150W Metal Halide, Increased safety Ex"e" light fitting for area classification Zone 2, Gas gr IIB,T3, enclosed Mid bay Luminaries with aluminum reflector, U hook for suspension mounting Increased safety Non - Integral 1x250W Metal Halide, Increased safety Ex"e" light fitting for area classification Zone 2, Gas gr IIB,T3 enclosed Mid bay Luminaries with aluminum reflector, U hook for suspension mounting Increased safety Non - Integral 1x400W Metal Halide, Increased safety Ex"e" light fitting for area classification Zone 2, Gas gr IIB,T3 enclosed high bay Luminaries wide beam with aluminum reflector, U hook for suspension mounting Increased safety Other Light Fitting Increased safety Ex"e" light fitting for area classification Zone 2, Gas gr IIB,T3, Aviation / AIR CRAFT

Unit rate

Unit rate

61

65

Unit rate

Unit rate

Unit rate Unit rate

Unit rate

Unit rate

Unit rate

Unit rate

Unit rate

Unit rate

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 12 of 22

SR No.

LIGHT FITTING DESCRIPTION WARNING light fitting with NEON lamp as per ICAO Regulations Increased safety Ex"e" light fitting for area classification Zone 2, Gas gr IIB,T3,6VA, 230V, 3 HR Battery Backup with lamp LED EXIT SIGN Increased safety Ex"e" light fitting for area classification Zone 2, Gas gr IIB,T3,230V, 60W GLS Vessel lamp with switch

Vendor Model No.

Actual Qtys.

Spare Qtys.

Final Quantity

Unit rate Unit rate

Unit rate

Unit rate

A.3) Flameproof type Light Fittings (Ex d) (Along with lamps) Vendor to supply all Increased safety Light fitting with Atex/Baseefa certification SUITABLE FOR ZONE-1, IIA/IIB, TEMP CLASS T3 Sr. No. Vendor Model No. Actual Qtys. Spare Qtys. Final Quantity

LIGHT FITTING DESCRIPTION

Flameproof Well Glass light fitting Integral Well Glass flame proof Ex"d" light fitting for area classification Zone 1, Gas gr IIB,T3 with 70W Metal Halide lamp (E),IP-65 (suitable for Suspended/bracket mounting) Integral Well Glass flame proof Ex"d" light fitting for area classification Zone 1, Gas gr IIB,T3 with 70W Metal Halide lamp (E),IP-65 (suitable for Pole mounting) Integral Well Glass flame proof Ex"d" light fitting for area classification Zone 1, Gas gr IIB,T3 with 150W Metal Halide lamp (E),IP-65 (suitable for Suspended mounting) Flameproof High / Mid bay light fitting Integral 1x150W Metal Halide (E), with control gear box, flame proof Ex"d" light fitting for area classification Zone 1, Gas gr IIB,T3, enclosed Mid bay Luminaries with aluminum reflector, U hook for suspension mounting

Unit rate

Unit rate

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 13 of 22

Sr. No. 2

LIGHT FITTING DESCRIPTION Non - Integral 1x250W Metal Halide (E), with control gear box, flame proof Ex"d" light fitting for area classification Zone 1, Gas gr IIB,T3enclosed Mid bay Luminaries with aluminum reflector, U hook for suspension mounting Non - Integral 1x400W Metal Halide (E), flame proof Ex"d" light fitting for area classification Zone 1, Gas gr IIB,T3enclosed High bay Luminaries with aluminum reflector, U hook for suspension mounting Flameproof safety Other Light Fitting flame proof Ex"d" light fitting for area classification Zone 1, Gas gr IIB,T3, IP65, Aviation / AIR CRAFT WARNING light fitting with NEON lamp as per ICAO Regulations flame proof Ex"d" light fitting for area classification Zone 1, Gas gr IIB,T3, IP65, 6VA, 230V, 3 HR Battery Backup with lamp LED EXIT SIGN flame proof Ex"d" light fitting for area classification Zone 1, Gas gr IIB,T3, IP65, 230V, 60W GLS Vessel lamp with switch

Vendor Model No. *

Actual Qtys. Unit rate

Spare Qtys.

Final Quantity

Unit rate

Unit rate

Unit rate

Unit rate

Unit rate

Unit rate Unit rate

Unit rate

Unit rate

B.4) Hazardous dust proof type Light Fittings (Along with lamps) (ZONE-20) Combustible Dust

(Not required)
SR No. SUITABLE FOR ZONE-20, COMBUSTIBLE DUST, TEMP CLASS T3 Vendor Actual Spare LIGHT FITTING DESCRIPTION Model Qtys. Qtys. No. Hazardous Dustproof Well Glass light fitting Integral Well Glass dustproof light fitting for area classification Zone20, T3 with 70W Metal Halide lamp (E),IP-65 (suitable for Suspended/bracket mounting) Integral Well Glass dustproof light fitting for area classification Zone20, T3 with 70W Metal Halide lamp Final Quantity

* *

Unit rate Unit rate

Unit rate

Unit rate

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 14 of 22

SR No. 3

LIGHT FITTING DESCRIPTION (E),IP-65 (suitable for Pole mounting) Integral Well Glass dustproof light fitting for area classification Zone20, T3 with 150W Metal Halide lamp (E),IP-65 (suitable for Suspended mounting) Hazardous Dustproof High / Mid bay light fitting Non - Integral 1x150W Metal Halide (E), with control gear box dustproof light fitting for area classification Zone20, T3 enclosed Mid bay Luminaries with aluminum reflector, U hook for suspension mounting Non - Integral 1x250W Metal Halide (E), with control gear box dustproof light fitting for area classification Zone20, T3 ,enclosed Mid bay Luminaries with aluminum reflector, U hook for suspension mounting Hazardous Dustproof Other Light Fitting Dustproof light fitting for area classification Zone20, T3 ,6VA, 230V, 3 HR Battery Backup with lamp LED EXIT SIGN

Vendor Model No.

Actual Qtys. Unit rate

Spare Qtys. -

Final Quantity Unit rate

Unit rate

Unit rate

Unit rate

Unit rate

Unit rate

Unit rate

Notes to Vendor for Industrial and Flameproof Light Fittings 1 Light fitting quantity is based on Lighting Layouts received from Piping / civil/ Package vendor. 2. Vendor shall provide cable glands and end plug of light fittings and control gear box as mentioned in specification. Cable glands/end plug sizes shall be 3core x 2.5 sq.mm. copper armoured cable. 3. Unit rate shall be furnished by Vendor. 4. All Light fittings hardwares like bolts, nut, washers etc. required for mounting shall be supplied by Vendor. 5. All light fittings shall be quoted along with lamps. 4. Vendor to furnish detail catalogue for each light fitting type.

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 15 of 22

C) SCOPE MATRIX FOR VENDOR & CONTRACTOR FOR BOP Site Testing and PreSupervision Commissioning commissioning during test installation Contractor Contractor Contractor

Supply Industrial and Flameproof Local Control Stations (LCS) Industrial and Flameproof Light Fittings Installation accessories as indicated in specifications

Installation

Vendor

Contractor

Vendor

Contractor

Contractor

Contractor

Contractor

Vendor

Contractor

Contractor

Contractor

Contractor

Note to PTSC Light fittings / Local control station MR for non-BOP areas will be issued separately by following agencies1. Main Process Plant - by Alfa Laval 2. Non Plant building - by PVE 3. Packages (Co-Gen/ Cassava/WWTP etc) - by respective Package Vendors 4. Local control station quantity for following packages by respective package vendor i.e. cooling tower, DM storage, Fresh water & fire water tank area, CO2 recovery area, Chiller unit building , compressor area and DDFS area however Light fitting quantity shall be by APG. 4
4.1 4.2 4.3

GENERAL REQUIREMENT Equipment design shall be as per latest edition of codes & standards as specified in the respective equipment specification. Equipment shall be designed such that it shall be easy to operate & maintain. Equipment qualification criteria shall be as follows; Offered equipment shall similar in all respect (i.e. all operating & design parameters requirement). When compared with at least 2 No of models design, Supplied, installed from same manufacturing plant as that of offered model; which are successfully operating for 2 or more years. In case of non proven manufacturer written approval from contractor/Owner shall be obtained. If improved safety benefits are offered, these may be included only with Contractors prior written approval.

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 16 of 22

4.4

Deviation if any for this specification or for standard mentioned in this specification any where shall be clearly specified along with the offer as Deviations from Specification. Compliance by vendor with provisions of this specification does not relieve him of his responsibility to furnish equipment and accessories of proper design to meet the specified service conditions and or local codes or standards governing health and safety. Any change in design data or unit specification resulting in capacity/performance modifications shall be done only after prior approval of the contractor/Owner. Equipment selected shall operate at specified operating conditions as specified in the respective specification & data sheet. The maximum allowable noise level shall be as per TCVN 5949 from the equipment in any direction. If this not possible necessary acoustic treatment shall be quoted separately. Where acoustic treatment is blocking individual equipment access, vendor should clearly indicate necessary instructions in operating and maintenance manual regarding use safety ear plugs and regarding indication of warning notice at appropriate places. All equipment shall be of good industrial quality such as to have a minimum life expectancy of 20 years assuming normal levels of care and maintenance. 6 months.

4.5

4.6 4.7 4.8

4.9

4.10 Equipment packing shall be suitable for marine environment outdoor storage for 4.11 Electrical and Instrument items shall be sealed in polythene envelopes. Desiccant

shall be enclosed within the envelope for motors, switchgear and control panels, etc. Warning labels shall indicate that desiccant is contained within.
4.12 As far as possible amount of dismantling shall be minimal for minimizing the

quantity of loose supply. All the ancillary equipments & spares shall be suitably tagged & shall be clearly mentioned in the Vendors shipment list.
4.13 Vendor to note that these specifications depict minimum requirements of the

required package. Hence, it is expected from the Vendor to submit to the Purchaser for agreement all calculations sheets and possible solutions that could give technical and/or economical improvement. Vendors are encouraged to suggest modifications which will improve system design and performance.
4.14 Vendor shall follow project specific documentation & numbering procedure as

attached.
4.15 Vendor list shall be followed as separate document prepared by Contractor.

Document description shall be Approved Project Vendor List (APVL).

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 17 of 22

PRECEDENCE In case of any conflict following document shall govern with order of precedence as follows; Local statutory laws & requirements. Equipment data sheet & specification. Purchase requisition. Applicable codes & standards.

VENDOR DOCUMENT REQUIREMENT Vendor to follow project specific numbering procedure and frames/templates for all vendor drawings.(The details will be furnished later for successful vendor). All drawings shall be in AUTOCAD2004. Vendor shall submit following documents/drawings as minimums during offer. 1) GA & foundation drawings of all the equipments. 2) Procurement plan for equipments & materials. (Showing the way how the vendor will proceed with this job, describes the country of origin of equipments & material for e.g. raw material). 3) All document as required by drawing data schedule. 4) Documentation as required by requisitioned, together with schedule of documents. 5) Proceed spare part list, including parts recommended by VENDOR for first ,second & third year of operation & maintenance such as frequency, duration, training if required after sales service (Vendor maintenance service). 6) Statement the preparation and supply of spare parts & interchangeablity register (SPIR) shall be part of the purchaser order for first, second & third year operating spares & maintenance such as frequency, duration, training if required after sales service (Vendor maintenance service or Owners trained operators) in accordance with SPIR system. 7) Project inspection requirement and material certificate requirements. 8) Operation and maintenance manual (5sets). 9) Quality assurance plan.

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 18 of 22

10) Non conformance with the specification shall be clear & listed separately. 11) Monthly progress report. 12) For Vendor data and document schedule, Please refer to Annexure of attached document. 7 PROCUREMENT PLAN Vendor to submit Procurement plan for Equipments mentioned in this MR. It has to satisfy with the requirement of the contract and schedule for procurement. 8 QUALITY REQUIREMENT The material used for making the equipments shall be brand new. No used / scrapped materials are to be used. Each raw materials used for this equipment shall have factory issued certificate. All bought out items shall have test certificates & from manufacturer. Equipment should have the name plate it comprises of Serial number, Tag no.and all technical details with punch year of manufacturing etc.

9
9.1

SPARE REQUIREMENTS
Installation , Pre-Commissioning, Commissioning and Start up Spares

The vendor shall be responsible for providing spares required to prepare the unit for start-up, and to safeguard the operation of the unit during storage, installation, precommissioning, commissioning and start-up periods in accordance with vendor recommendation and the applicable project specifications. The Vendor shall provide, with his bid, a list of the recommended installation, precommissioning, and start up spares for all materials under this Requisition including sub-order items for Purchasers evaluation. The Vendor shall develop such spare parts list in Purchasers format based on his final design and equipment selection and submit for Purchasers review during detail design.

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 19 of 22

As failures and replacements are more frequent during this portion of the Project, Vendor shall ensure recommending sufficient spares for progressing site work without delay. If parts other than recommended are damaged or shortages on recommended spares occur under normal site working condition, vendor shall provide such parts immediately on demand by the fastest means (i.e. airway shipment) without impact to the Purchaser. (Normal site working condition is defined as the condition that Purchasers personnel execute site work in accordance with the instructions by Vendor manual and / or the instructions by Vendors personnel for on-site supervision). These spares shall be supplied together with the main equipment items to which they relate as part of the scope of supply of the Vendor, in a separate box.
9.2

Two (2) Year Operation Spares

The vendor shall be responsible for providing two (2) year operation spares in accordance with vendor recommendation and Technical Specifications for Owners consideration as an option along with his bid. The vendor shall provide, with his bid, a priced list of the two (2) year operation spares for all materials under this Requisition including sub-order items for Purchasers evaluation. The vendor shall develop such spare parts list in Purchasers format based on his final design and equipment selection and submit for Purchasers review during detail design. These spares shall be supplied together with the main equipment items to which they relate as part of the scope of supply of the Vendor, in a separate box.
9.3

Capital Spares

The vendor shall be responsible for providing insurance spares in accordance with vendor recommendations and Technical specifications for Owner consideration as an option. Priced list shall be submitted with his bid. The capital spare parts shall include the followings, as a minimum. These spares shall be supplied together with the main equipment items to which they relate as part of the scope of supply of the vendor, in a separate box.
9.4

Special Tools

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 20 of 22

The vendor shall be responsible for providing special tools required for the maintenance or installation of the equipment. Special tools are defined as any tool, which is manufactured specifically for use on Vendors equipment or material and is required for installation, operation and maintenance of any items furnished by the vendor. These spares shall be supplied together with the main equipment items to which they relate as part of the scope of supply of the Vendor, in a separate box.
9.5

Consumables

The vendor shall be responsible for providing commissioning and start-up consumables (i.e. chemicals, papers, etc.) other than grease and lube/flushing oil, if any. Grease and lube / flushing oil are Purchaser supply. The vendor shall develop consumables list for Purchasers review during detail design. These consumables shall be supplied together with the main equipment items to which they relate as part of the scope of supply of the vendor, in a separate box. 10 PERFORMANCE & WARRANTEE / GUARANTEE. Package & its accessories shall be guaranteed for performance of the all equipments within package operating at specified conditions & rating for a period of 24 months from date of acceptance certificate. The equipment and its accessories shall be guaranteed against faulty design defective or wrong selection materials or poor workmanship or failure from normal use during the guarantee period. Vendor shall make necessary and desirable alternation repairs and replacement free of charge to the purchaser in the event of failure of the equipment.

11 SPECIAL REQUIREMENT
11.1 No prototype or unproven equipment or equipment built to unknown

manufacturing standards shall be incorporated. In this respect, proven shall mean a minimum of two (2) separate systems or installations successfully operating for two (2) or more years. In cases of doubt, the approval of CONTRACTOR shall be obtained in writing and contractors decision shall be final. If improved safety benefits are offered, these may be included only with Contractors prior written approval.

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 21 of 22

11.2 The design shall lead to simplicity of operation and maintenance. 11.3 The design of equipment and the selection of construction materials shall be such

as to accommodate all pressures, temperatures, stresses, corrosive conditions etc, which may occur during construction, PRECOMMISSIONING, COMMISSIONING, and normal operations and as a result of extreme operating conditions.

12

DEFECTS LIABILITY

The defect liability period for replaced and / or repaired parts of the plant shall expire thirty five (35) months from the date of the initial acceptance certificate.

13 Sr.no. I 1 2 3 4 5 6 7 8 9. II 1 2 3 4 5

APPLICABLE DOCUMENTS Document description General Project Procedure Document Numbering Procedure Procurement Procedure Project Quality assurance plan Quality assurance manual Packing, Marking & Shipping Instructions Non-conformance with Project Specification Document control procedure Vendor document numbering procedure Final Vendor data and manufacturer data record book Project Standards & Specification Specification for Industrial and Flameproof Local control station Specification for Industrial Type Light fittings Protective Finishes For Electrical Equipment For Outdoor Use Requirements for Spare Parts Training Specification Document no. 8455001-000-PP-0004 8455001-000-PP-0002 8455001-000-PP-0008 8455001-000-PP-0011 8455001-000-PP-0096 8455001-000-PP-0051 8455001-000-PP-0097 8455001-000-PP-0112 8455001-000-PP-0111 Rev 08 04 02 00 00 02 00 00 00

8455001-007-SP-0013 8455001-007-SP-0016 8455001-007-SP-0003 8455001-2000-GI-M0001 8455001-000-SP-0002

B0 B0 01 02 B0

MATERIAL REQUISITION FOR INDUSTRIAL AND FLAMEPROOF LOCAL CONTROL STATIONS (LCS) AND LIGHT FITTINGS
Project No 8455001 Discipline Code/ Area No. 3000 Doc. Classification Code RQ Sequence No. E0006 Rev. B0 Page 22 of 22

Instrument/Electrical Interface specification

8455001-005-SP-0024

00

III 1

Applicable Codes & Standards Electrical Engineering standards

8455001-007-SP-0001

B0 B0

Hazardous area classification Drawing IV 8455001-3000-79-R0001 Note Vendor to follow latest revision of the document.

ANNEXURE -1

Local Control Station name plate details. Refer Annexure-1 (Revision C0) for LCS MTO tag Plate

Aker Powergas Pvt. Ltd., Pune INDUSTRIAL LOCAL CONTROL STATION


EDMA Ver 1.3

Page : 2 of 6

Project No.: Project : Client :

8455001 DUNG QUAT BIO-FUELS ETHANOL PLANT PTSC Quang Ngai Co. Ltd.

Annexure -1 Document No.: Rev No.: C0 , Rev Date: 28/02/2011 ORDER Issued For:

SAAO : MOTOR INDUSTRIAL LOCAL START / STOP PUSH BUTTON Equipment Number PC-2003A PC-2003B PC-7305A PC-7305B PC-7302A PC-7302B PC-9011 PC-6107 AG-9004 PC-8202A PC-8202B AG-8301 PC-7901 PC-7902 PC-7903 PC-7904 PC-7906 PC-7907 PC-7101A PC-7101D PC-7101B PC-7101C PC-2001 PC-8116B PC-8116A Z-8101A Z-8102A FA-8104A Z-8201 SPARE SPARE SPARE SPARE Description on Name plate JOCKEY PUMP-1 JOCKEY PUMP-2 POTABLE WATER PUMP POTABLE WATER PUMP DMW TRANSFER PUMP DMW TRANSFER PUMP CAUSTIC TRANSFER PUMP BIO ETHANOL PIT EVACUATION PUMP CAUSTIC TANK AGITATOR MOTOR CHILLED WATER PUMPS -II CHILLED WATER PUMPS -II THIN SLOP TANK AGITATOR MOTOR EFFLUENT TRANSFER PUMP-I EFFLUENT TRANSFER PUMP-II EFFLUENT TRANSFER PUMP-III EFFLUENT TRANSFER PUMP-IV SEWAGE WATER PUMP-1 SEWAGE WATER PUMP-II COOLING WATER PUMP-1 COOLING WATER PUMP-4 COOLING WATER PUMP-2 COOLING WATER PUMP-3 FIRE FIGHTING SYSTEM MOTOR BOILER FEED WATER PUMP BOILER FEED WATER PUMP STG - PA FAN MOTOR STG - SA FAN MOTOR STG - ID FAN MOTOR PROCESS WATER CHILLER MOTOR Board No. 01-EMCC-03-01 01-EMCC-03-01 01-MCC-03-01 01-MCC-03-01 01-MCC-03-01 01-MCC-03-01 02-MCC-03-06 02-MCC-03-05 02-MCC-03-06 02-MCC-03-06 02-MCC-03-06 02-MCC-03-06 02-MCC-03-06 02-MCC-03-06 02-MCC-03-06 02-MCC-03-06 02-MCC-03-06 02-MCC-03-05 01-SMV-02-01 01-SMV-02-01 01-SMV-02-01 01-SMV-02-01 01-SMV-02-01 01-SMV-02-01 01-SMV-02-01 01-SMV-02-01 01-SMV-02-01 01-SMV-02-01 02-SMV-02-01 kW Rating 15 15 3.7 3.7 3.7 3.7 0.25 18.5 0.75 11 11 15 5.5 5.5 5.5 5.5 4 5.5 425 425 425 425 480 315 315 355 200 355 250 Remarks

Aker Powergas Pvt. Ltd., Pune INDUSTRIAL LOCAL CONTROL STATION


EDMA Ver 1.3

Page : 3 of 6

Project No.: Project : Client :

8455001 DUNG QUAT BIO-FUELS ETHANOL PLANT PTSC Quang Ngai Co. Ltd.

Document No.: Annexure -1 Rev No.: C0 , Rev Date: 28/02/2011 ORDER Issued For:

SACO : INDUSTRIAL LOCAL START / STOP PUSHBUTTON WITH AMMETER Equipment Number PC-8201A PC-8201B PC-8301A PC-8301B Z-7101-1 Description on Name plate CHILLED WATER PUMPS -I CHILLED WATER PUMPS -I THIN SLOP TRANSFER PUMP (BY ALIL) THIN SLOP TRANSFER PUMP (BY ALIL) COOLING TOWER FAN-1 (START/STOP LCS) COOLING TOWER FAN-2 (START/STOP LCS) COOLING TOWER FAN-3 (START/STOP LCS) COOLING TOWER FAN-4 (START/STOP LCS) PROCESS WATER TRANSFER PUMP PROCESS WATER TRANSFER PUMP Ammeter CT Ratio Board No. 02-MCC-03-06 02-MCC-03-06 02-MCC-03-06 02-MCC-03-06 01-PCC-03-01 kW Rating 37 37 55 55 110 Remarks

75/1 75/1 150/1 150/1 250/1 250/1 250/1 250/1 250/1 250/1 150/1 250/1

Z-7101-2

01-PCC-03-01

110

Z-7101-3

01-PCC-03-01

110

Z-7101-4 PC-7301A PC-7301B SPARE SPARE

01-PCC-03-01 01-PCC-03-01 01-PCC-03-01

110 110 110

Aker Powergas Pvt. Ltd., Pune FIELD DEVICE LIST


EDMA Ver 1.3

Page : 4 of 6

Project No.: Project : Client :

8455001 DUNG QUAT BIO-FUELS ETHANOL PLANT PTSC Quang Ngai Co. Ltd.

Annexure -1 Document No.: Rev No.: C0 , Rev Date: 28/02/2011 ORDER Issued For:

SAB0 : INDUSTRIAL EMERGENCY LOCAL STOP PUSHBUTTON Equipment Number 02-TRN-02-06 02-TRN-02-05 02-TRN-02-04 02-TRN-02-03 02-TRN-02-02 02-TRN-02-01 01-TRN-02-01 01-TRN-02-02 01-CAP-02-01 01-CAP-02-02 01-TRN-01-02 01-TRN-01-01 Z-7101-1 Description on Name plate DISTRIBUTION TRANSFORMER DISTRIBUTION TRANSFORMER DISTRIBUTION TRANSFORMER DISTRIBUTION TRANSFORMER DISTRIBUTION TRANSFORMER DISTRIBUTION TRANSFORMER DISTRIBUTION TRANSFORMER DISTRIBUTION TRANSFORMER MV CAPACITOR PANEL MV CAPACITOR PANEL POWER TRANSFORMER (8MVA) POWER TRANSFORMER (8MVA) COOLING TOWER FAN-1 (EM. STOP LCS TO BE WIRED FROM START/STOP LCS) COOLING TOWER FAN-2 (EM. STOP LCS TO BE WIRED FROM START/STOP LCS) COOLING TOWER FAN-3 (EM. STOP LCS TO BE WIRED FROM START/STOP LCS) COOLING TOWER FAN-4 (EM. STOP LCS TO BE WIRED FROM START/STOP LCS) Board No. 02-SMV-02-01 02-SMV-02-01 02-SMV-02-01 02-SMV-02-01 02-SMV-02-01 02-SMV-02-01 01-SMV-02-01 01-SMV-02-01 01-SMV-02-01 01-SMV-02-01 01-SMV-02-01 01-SMV-02-01 01-PCC-03-01 kVA Rating 1600 1600 2500 2500 2500 2500 2000 2000 500 1000 8000 8000 110 kW Remarks

Z-7101-2

01-PCC-03-01

110 kW

Z-7101-3

01-PCC-03-01

110 kW

Z-7101-4 SPARE SPARE

01-PCC-03-01

110 kW

Aker Powergas Pvt. Ltd., Pune FIELD DEVICE LIST


EDMA Ver 1.3

Page : 5 of 6

Project No.: Project : Client :

8455001 Document No.: Annexure -1 DUNG QUAT BIO-FUELS ETHANOL PLANT Rev No.: C0 , Rev Date: 28/02/2011 ORDER PTSC Quang Ngai Co. Ltd. Issued For: F2AO : MV MOTOR FLP LOCAL START / STOP PUSH BUTTON

Equipment Number PC-6108 PC-6109 PC-9010 PC-9012 PC-7905 PC-9001 PC-9005 PC-9006 PC-9003 PC-9009 PC-6102A PC-6102B PC-6106 PC-6103A PC-6103B PC-7201A PC-7201B SPARE CABLE PC-2101A HM-8503C HM-8503A HM-8503B PC-2101B SPARE SPARE SPARE SPARE

Description on Name plate BIO ETHANOL PIT EVACUATION PUMP DENATURANT DOSING PUMP AQ.NH3 BUND EVACUTION PUMP CAUSTIC BUND EVACUATION PUMP EFFLUENT TRANSFER PUMP-V H2SO4 TRANSFER PUMP H2SO4 UNLOADING PUMP H2SO4 BUND EVACUATION PUMP AQ.NH3 TRANSFER PUMP AQ.NH3 UNLOADING PUMP

Board No. 02-MCC-03-05 02-MCC-03-05 02-MCC-03-05 02-MCC-03-06 02-MCC-03-05 02-MCC-03-05 02-MCC-03-05 02-MCC-03-05 02-MCC-03-05 02-MCC-03-05

kW Rating 7.5 1.1 1.1 1.1 5.5 2.2 3.7 1.1 0.25 1.1 5.5 5.5 2.2 2.2 2.2 5.5 5.5 1.1 185 250 250 250 185

Remarks

OFFSPEC-BIO-ETHANOL TRANSFER PUMP 02-MCC-03-05 OFFSPEC-BIO-ETHANOL TRANSFER PUMP 02-MCC-03-05 DENATURANT UNLOADING PUMP DENATURANT DOSING PUMP DENATURANT DOSING PUMP LP CONDENSATE TRANSFER PUMP LP CONDENSATE TRANSFER PUMP SPARE CABLE SLURRY MIX PUMP A CASSAVA HAMMER MILL-3 CASSAVA HAMMER MILL-1 CASSAVA HAMMER MILL-2 SLURRY MIX PUMP B 02-MCC-03-05 02-MCC-03-06 02-MCC-03-06 02-MCC-03-06 02-MCC-03-06 02-MCC-03-05 02-SMV-02-01 02-SMV-02-01 02-SMV-02-01 02-SMV-02-01 02-SMV-02-01

Aker Powergas Pvt. Ltd., Pune FIELD DEVICE LIST


EDMA Ver 1.3

Page : 6 of 6 Document No.: Annexure -1 Rev No.: C0 , Rev Date: 28/02/2011 ORDER Issued For:

Project No.: Project : Client :

8455001 DUNG QUAT BIO-FUELS ETHANOL PLANT PTSC Quang Ngai Co. Ltd.

F2CO : FLAMEPROOF LOCAL START / STOP PUSHBUTTON WITH AMMETER Equipment Number PC-6104A PC-6104B PC-8302A PC-8302B PC-6101A PC-6101B SPARE Description on Name plate COMMERCIAL BIO-ETHANOL TRANSFER PUMP COMMERCIAL BIO-ETHANOL TRANSFER PUMP WHOLE STILLAGE TRANSFER PUMP (BY ALIL) WHOLE STILLAGE TRANSFER PUMP (BY ALIL) BIO-ETHANOL TRANSFER PUMP BIO-ETHANOL TRANSFER PUMP Ammeter CT Ratio Board No. 02-MCC-03-05 02-MCC-03-05 02-MCC-03-06 02-MCC-03-06 02-MCC-03-06 02-MCC-03-06 kW Rating 30 30 37 37 30 30 Remarks

75/1 75/1 75/1 75/1 75/1 75/1 75/1

You might also like