Paramount OEN Relay
Paramount OEN Relay
system
LED Indicator Mechanical Flag Indicator
Marking Label Coil Voltage Marking
Isolation between coil and contact 5KV Solid Brass Round Pin
P3 is a Two & Three Pole Industrial Plug In Relay with all the In-built
Mechanical and Electronic Features.
Coil Terminals
(4, A1 +ve), (5, A2 -ve)
Standard 35mm m
DIN rail 38m Socket width 38mm
S8D & S11D is a Two Pole & Three Pole Touch protected Interface Socket.
C
Benefits
of the new
system
LED Indicator Mechanical Flag Indicator
Marking Label Coil Voltage Marking
Isolation between coil and contact 5KV Solid Brass Round Pin
P3 is a Two & Three Pole Industrial Plug In Relay with all the In-built
Mechanical and Electronic Features.
Coil Terminals
(4, A1 +ve), (5, A2 -ve)
m
Standard 35mm 38m Socket width 38mm
DIN rail
S8D & S11D is a Two Pole & Three Pole Touch protected Interface Socket.
P3-2
General Purpose 2 C/O Contacts
10 A 250V AC1 0.5 A 110V DC1
10 A 30V DC1 0.2 A 220V DC1
NC NO NC NO
2
Contacts
4 3 5 6
12 14 22 24 A1 (+) Materials : Standard AgNi
Optional 1 AgNi + Au 0.2 µ
COIL Optional 2 AgNi + Au 5.0 µ
Max. Switching Current 10A
11 21 A2 (-) Max. Peak Inrush Current (20 ms) 30A
1 8 7 Max. Switching Voltage 250 VAC
COM COM Switching Power range 0.3 VA (W) to 2500 VA
Max. Contact Resistance 20m Ω
Max. AC Load (Table 1) 2.5 KVA
Max. DC Load (See Table 2) -
Coils (Ohms ± @ 20ºC)
Pull-in Voltage <
- 0.8xUn
Graph 1 Electrical life, ops x 10 6 Drop-out Voltage ≥ 0.1xUn
Nominal Coil Power 2.5 VA (AC / 1.3 W (DC)
VAC Ohms VDC Ohms
6 3.15 6 33
12 13.3 12 115
24 52 24 480
48 240 48 1850
110 1120 110 9000
230 5600 220 29000
Insulation
Dielectric Strength (1 minute) : open contacts 1500 VAC
Between adjacent poles 2000 VAC
Between contacts and coil 2500 VAC
Graph 2 Max. DC load Insulation Resistance @ 500VDC Min. ≥ 200 MΩ
Isolation, IEC 61810-5 2.5 KV / 3
Specifications
Operate / Release & Bounce Time Max. for DC +3 / 3.5+ ms
Operate / Release & Bounce Time Max. for AC 9+8 / 12+16 ms
Mechanical Life ops. 10 Million AC, 20 Million DC relays
Electrical life at Nominal load ≥ 100,000 ops.
Operating Frequency at nominal load 1200 / hour
Shock Resistance AK : > 10g
Vibration Resistance 5g 10…..150 Hz
Mounting Direction any
Storage -40°C to +85°C
Ambient Operating Temperature -40°C to +55°C (for AC relay)
Ambient Operating Temperature -40°C to +70°C (for DC relay)
Protection Standard IP 40
Dimensions in mm. Weight app. 80 g
35 Standard Types
AC : 6, 12, 24, 48, 110, 230
A1 14 F = Mechanical Flag Indicator P3-2-F …. VAC
2 3 P = LED Indicator P3-2-FP …. VAC
11 1 4 12 I = Lockable Push Button P3-2-FPI …. VAC
R = RC Circuit P3-2-FIR …. VAC
35
21 8 5 22
7 6 DC : 6, 12, 24, 48, 110 , 220
A2 24 F = Mechanical Flag Indicator P3-2-F …. VDC
P = LED P3-2-FP …. VDC
I = Lockable Push Button P3-2-FPI …. VDC
W = Free Wheeling Diode P3-2-FPIW …. VDC
Z = Polarity & Free Wheeling Diode P3-2-FPZI …. VDC
B = AC/DC Bridge Rectifer P3-2-FPIB …. VAD
52
48
51
Approvals
C US
9
13
P3-2A
General Purpose 2 NO Contacts
10 A 250V AC1 0.7 A 110V DC1
10 A 30V DC1 0.4 A 220V DC1
Contacts
Materials : Standard AgNi
Optional 1 AgNi + Au 0.2 µ
NO NO Optional 2 AgNi + Au 5.0 µ
3 6 2 Max. Switching Current 10A
14 24 A1 (+) Max. Peak Inrush Current (20 ms) 30A
Max. Switching Voltage 250 VAC
COIL Switching Power range 0.3 VA (W) to 2500 VA
Max. Contact Resistance 20m Ω
11 21 A2 (-) Max. AC Load (Table 1) 2.5 KVA
1 8 7 Max. DC Load (See Table 2) -
COM COM Coils (Ohms ± @ 20ºC)
Pull-in Voltage < 0.8xUn
-
Drop-out Voltage ≥ 0.1xUn
Graph 1 Electrical life, ops x 106 Nominal Coil Power 1.6 VA (AC / 1.3 W (DC)
VAC Ohms VDC Ohms
6 3.15 6 33
12 13.3 12 115
24 52 24 480
48 240 48 1850
110 1120 110 9000
230 5600 220 29000
Insulation
Dielectric Strength (1 minute) : open contacts 2000 VAC
Between adjacent poles 2000 VAC
Between contacts and coil 2500 VAC
Graph 2 Max. DC load Insulation Resistance @ 500VDC Min. 200 MΩ
Isolation, IEC 61810-5 2.5 KV / 3
Specifications
Operate / Release & Bounce Time Max. for DC 20+3 ms
Operate / Release & Bounce Time Max. for AC 20+8 ms
Mechanical Life ops. 10 Million AC, 20 Million DC relays
Electrical life at Nominal load ≥ 100,000 ops.
Operating Frequeny at nominal load 1200 / hour
Shock Resistance AK : > 10g
Vibration Resistance 5g 10…..150 Hz
Mounting Direction any
Storage -40°C to +85°C
Ambient Operating Temperature -40°C to +55°C (for AC relay)
Ambient Operating Temperature -40°C to +70°C (for DC relay)
Dimensions in mm. Protection Standard IP 40
Weight app. 80 g
35
Standard Types
A1 14
AC : 6, 12, 24, 48, 110, 230
2 3 F = Mechanical Flag Indicator P3-2A-F …. VAC
11 1 4 12 P = LED Indicator P3-2A-FP …. VAC
R = RC Circuit P3-2A-FR …. VAC
35
21 8 5 22
7 6
48
51
Approvals
C US
9
13
P3-X
General Purpose 1 NO + 1 NC Contacts
10 A 250V AC1 0.7 A 110V DC1
10 A 30V DC1 0.4 A 220V DC1
Contacts
Materials : Standard AgNi
Optional 1 AgNi + Au 0.2 µ
NC NO
2 Optional 2 AgNi + Au 5.0 µ
4 6 Max. Switching Current 10A
12 24 A1 (+) Max. Peak Inrush Current (20 ms) 30A
Max. Switching Voltage 250 VAC
COIL Switching Power range 0.3 VA (W) to 2500 VAz
Max. Contact Resistance 20m Ω
11 21 A2 (-) Max. AC Load (Table 1) 2.5 KVA
1 8 7 Max. DC Load (See Table 2) -
Coils (Ohms ± @ 20ºC)
COM COM Pull-in Voltage < 0.8xUn
-
Drop-out Voltage ≥ 0.1xUn
Graph 1 Electrical life, ops x 10 6
Nominal Coil Power 1.6 VA (AC / 1.3 W (DC)
VAC Ohms VDC Ohms
6 3.15 6 33
12 13.3 12 115
24 52 24 480
48 240 48 1850
110 1120 110 9000
230 5600 220 29000
Insulation
Dielectric Strength (1 minute) : open contacts 2000 VAC
Between adjacent poles 2000 VAC
Between contacts and coil 2500 VAC
Graph 2 Max. DC load Insulation Resistance @ 500VDC Min. 200 MΩ
Isolation, IEC 61810-5 2.5 KV / 3
Specifications
Operate / Release & Bounce Time Max. for DC 20+3 ms
Operate / Release & Bounce Time Max. for AC 20+8 ms
Mechanical Life ops. 10 Million AC, 20 Million DC relays
Electrical life at Nominal load ≥ 50 ,000 ops.
Operating Frequeny at nominal load 1200 / hour
Shock Resistance AK : > 10g
Vibration Resistance 5g 10…..150 Hz
Mounting Direction any
Storage -40°C to +85°C
Ambient Operating Temperature -40°C to +55°C (for AC relay)
Ambient Operating Temperature -40°C to +70°C (for DC relay)
Dimensions in mm. Protection Standard IP 40
Weight app. 80 g
35
Standard Types
A1 14
AC : 6, 12, 24, 48, 110, 230
2 3 F = Mechanical Flag Indicator P3-X-F …. VAC
11 1 4 12 P = LED Indicator P3-X-FP …. VAC
35
8 5 22
R = RC Circuit P3-X-FR …. VAC
21
7 6
51
Approvals
C US
9
13
P3-Y
General Purpose 1 NO Double Break
10 A 250V AC1 7.0 A 110V DC1
10 A 30V DC1 1.2 A 220V DC1
Contacts
Materials : Standard AgNi
Optional 1 AgNi + Au 0.2 µ
NO NO Optional 2 AgNi + Au 5.0 µ
3 6 2 Max. Switching Current 10A
14 24 A1 (+) Max. Peak Inrush Current (20 ms) 30A
Max. Switching Voltage 250 VAC
COIL Switching Power range 0.3 VA (W) to 2500 VA
Max. Contact Resistance 20m Ω
A2 (-) Max. AC Load (Table 1) 2.5 KVA
Max. DC Load (See Table 2) -
COM 7
Coils (Ohms ± @ 20ºC)
Pull-in Voltage < 0.8 x Un
-
Drop-out Voltage ≥ 0.1 x Un
Graph 1 Electrical life, ops x 106 Nominal Coil Power 1.6 VA (AC / 1.3 W (DC)
VAC Ohms VDC Ohms
6 3.15 6 33
12 13.3 12 115
24 52 24 480
48 240 48 1850
110 1120 110 9000
230 5600 220 29000
Insulation
Dielectric Strength (1 minute) : open contacts 2000 VAC
Between adjacent poles 2000 VAC
Between contacts and coil 2500 VAC
Graph 2 Max. DC load Insulation Resistance @ 500VDC Min. 200 MΩ
Isolation, IEC 61810-5 2.5 KV / 3
Specifications
Operate / Release & Bounce Time Max. for DC 20+3 ms
Operate / Release & Bounce Time Max. for AC 20+8 ms
Mechanical Life ops. 10 Million AC, 20 Million DC relays
Electrical life at Nominal load ≥ 100,000 ops.
Operating Frequeny at nominal load 1200 / hour
Shock Resistance AK : > 10g
Vibration Resistance 5g 10…..150 Hz
Mounting Direction any
Storage -40°C to +85°C
Ambient Operating Temperature -40°C to +55°C (for AC relay)
Ambient Operating Temperature -40°C to +70°C (for DC relay)
Dimensions in mm. Protection Standard IP 40
Weight app. 80 g
35
Standard Types
A1 14
AC : 6, 12, 24, 48, 110, 230
2 3 F = Mechanical Flag Indicator P3-Y-F …. VAC
11 1 4 12 P = LED Indicator P3-Y-FP …. VAC
R = RC Circuit P3-Y-FR …. VAC
35
21 8 5 22
7 6
48
51
Approvals
C US
9
13
P3-2.....M
Magnetic Blow Out 2 C/O Contacts
10 A 250V AC1 5 A 220V DC1
10 A 30V DC1 3 A 220V DC13
Contacts
Materials : Standard AgNi
Optional 1 AgNi + Au 0.2 µ
NC NO NC NO Optional 2 AgNi + Au 5.0 µ
4 3 5 6 2 Max. Switching Current 10A
12 14 22 24 A1 (+) Max. Peak Inrush Current (20 ms) 30A
Magnet Max. Switching Voltage 250 VAC
COIL Switching Power range 0.3 VA (W) to 2500 VA
Max. Contact Resistance 20m Ω
11 21 A2 (-) Max. AC Load (Table 1) 2.5 KVA
+ 1 8 7
COM COM Coils (Ohms ± @ 20ºC)
Pull-in Voltage <
- 0.8xUn
Drop-out Voltage ≥ 0.1xUn
Graph 1 Electrical life, ops x 10 6
Insulation
Dielectric Strength (1 minute) : open contacts 1500 VAC
Between adjacent poles 2000 VAC
Graph 2 Max. DC load Between contacts and coil 2500 VAC
Insulation Resistance @ 500VDC Min. 200 MΩ
10
Specifications
DC1 Operate / Release & Bounce Time Max. for DC 16+3 / 3.5+8 ms
1
L/R 40ms Operate / Release & Bounce Time Max. for AC 15+8 / 12+16 ms
Mechanical Life ops. 10 Million AC, 20 Million DC relays
Amps
A1 14 Coil:
Standard Types
3
24VDC
2
11 1 4 12
AC : 6, 12, 24, 48, 110, 230
M = Magnetic Blow Out
35
8 5 22
21 P = LED Indicator P3-2-PM …. VAC
7 6
R = RC Circuit P3-2-PRM …. VAC
A2 24
DC : 6, 12, 24, 48, 110 , 220
P = LED P3-2-PM …. VDC
W = Free Wheeling Diode P3-2-PWM …. VDC
Z = Polarity & Free Wheeling Diode P3-2-PZM …. VDC
B = AC/DC Bridge Rectifer P3-2-PBM …. VAD
52
48
51
Approvals
C US
9
13
P3-2A.....M
Magnetic Blow Out 2 NO Contacts
10 A 250V AC1 10 A 220V DC1
10 A 30V DC1 5 A 220V DC13
Contacts
Materials : Standard AgNi
Optional 1 AgNi + Au 0.2 µ
NO NO Optional 2 AgNi + Au 5.0 µ
3 6 2 Max. Switching Current 10A
14 24 A1 (+) Max. Peak Inrush Current (20 ms) 30A
Magnet Max. Switching Voltage 250 VAC
COIL Switching Power range 0.3 VA (W) to 2500 VA
Max. Contact Resistance 20m Ω
A2 (-) Max. AC Load (Table 1) 2.5 KVA
11 21
+ 1 8 7
Coils (Ohms ± @ 20ºC)
COM COM
Pull-in Voltage ≤ 0.8xUn
Drop-out Voltage ≥0.1xUn
Graph 1 Electrical life, ops x 10 6
Nominal Coil Power 1.6 VA (AC / 1.3 W (DC)
VAC Ohms VDC Ohms
6 3.15 6 33
12 13.3 12 115
24 52 24 480
48 240 48 1850
110 1120 110 9000
230 5600 220 29000
Insulation
Dielectric Strength (1 minute) : open contacts 2000 VAC
Between adjacent poles 2000 VAC
Between contacts and coil 2500 VAC
Graph 2 Max. DC load Insulation Resistance @ 500VDC Min. 200 MΩ
Isolation, IEC 61810-5 2.5 KV / 3
10
Specifications
Operate / Release & Bounce Time Max. for DC 20+3 ms
DC1 Operate / Release & Bounce Time Max. for AC 20+8 ms
1
L/R 40ms
Mechanical Life ops. 10 Million AC, 20 Million DC relays
Amps
Standard Types
A1 14 Coil:
2 3
24VDC
AC : 6, 12, 24, 48, 110, 230
11 1 4 12 M = Magnetic Blow Out
P = LED Indicator P3-2A-PM …. VAC
35
21 8 5 22
7 6 R = RC Circuit P3-2A-PRM …. VAC
A2 24 DC : 6, 12, 24, 48, 110 , 220
P = LED P3-2A-PM …. VDC
W = Free Wheeling Diode P3-2A-PWM …. VDC
Z = Polarity & Free Wheeling Diode P3-2A-PZM …. VDC
B = AC/DC Bridge Rectifer P3-2A-PBM …. VAD
52
48
51
Approvals
C US
9
13
P3-X.....M
Magnetic Blow Out 1 NO + 1NC Contacts
10 A 250V AC1 10 A 220V DC1
10 A 30V DC1 5 A 220V DC13
Contacts
Materials : Standard AgNi
Optional 1 AgNi + Au 0.2 µ
NC NO Optional 2 AgNi + Au 5.0 µ
4 6 2 Max. Switching Current 10A
A1 (+) Max. Peak Inrush Current (20 ms) 30A
12 24
Magnet Max. Switching Voltage 250 VAC
COIL Switching Power range 0.3 VA (W) to 2500 VA
Max. Contact Resistance 20m Ω
A2 (-) Max. AC Load (Table 1) 2.5 KVA
11 21
+ 1 8 7 Coils (Ohms ± @ 20ºC)
COM COM
Pull-in Voltage <
- 0.8 x Un
Drop-out Voltage ≥ 0.1 x Un
Graph 1 Electrical life, ops x 10 6
Nominal Coil Power 1.6 VA (AC / 1.3 W (DC)
VAC Ohms VDC Ohms
6 3.15 6 33
12 13.3 12 115
24 52 24 480
48 240 48 1850
110 1120 110 9000
230 5600 220 29000
Insulation
Dielectric Strength (1 minute) : open contacts 2000 VAC
Between adjacent poles 2000 VAC
Between contacts and coil 2500 VAC
Graph 2 Max. DC load Insulation Resistance @ 500VDC Min. 200 MΩ
Isolation, IEC 61810-5 2.5 KV / 3
10
Specifications
Operate / Release & Bounce Time Max. for DC 20+3 ms
Operate / Release & Bounce Time Max. for AC 20+8 ms
DC1
Mechanical Life ops. 10 Million AC, 20 Million DC relays
1
L/R 40ms
Electrical life at Nominal load ≥ 100,000 ops.
Amps
Standard Types
A1 14 Coil:
24VDC
2 3 AC : 6, 12, 24, 48, 110, 230
11 1 4 12
M = Magnetic Blow Out
P = LED Indicator P3-X-PM …. VAC
35
21 8 5 22
7 6 R = RC Circuit P3-X-PRM …. VAC
A2 24
DC : 6, 12, 24, 48, 110 , 220
P = LED P3-X-PM …. VDC
W = Free Wheeling Diode P3-X-PWM…. VDC
Z = Polarity & Free Wheeling Diode P3-X-PZM …. VDC
B = AC/DC Bridge Rectifer P3-X-PBM …. VAD
52
48
51
Approvals
C US
9
13
P3-Y.....M
Magnetic Blow Out 1 NO Double Break
10 A 250V AC1 10 A 220V DC1
10 A 30V DC1 7 A 220V DC13
Contacts
Materials : Standard AgNi
Optional 1 AgNi + Au 0.2 µ
NO + NO Optional 2 AgNi + Au 5.0 µ
3 6 2 Max. Switching Current 10A
14 24 A1 (+) Max. Peak Inrush Current (20 ms) 30A
Magnet Max. Switching Voltage 250 VAC
COIL Switching Power range 0.3 VA (W) to 2500 VAz
Max. Contact Resistance 20m Ω
A2 (-) Max. AC Load (Table 1) 2.5 KVA
COM 7
Coils (Ohms ± @ 20ºC)
Pull-in Voltage <
- 0.8 x Un
Drop-out Voltage ≥ 0.1 x Un
Graph 1 Electrical life, ops x 10 6
Nominal Coil Power 1.6 VA (AC / 1.3 W (DC)
VAC Ohms VDC Ohms
6 3.15 6 33
12 13.3 12 115
24 52 24 480
48 240 48 1850
110 1120 110 9000
230 5600 220 29000
Insulation
Dielectric Strength (1 minute) : open contacts 1500 VAC
Between adjacent poles 2000 VAC
Between contacts and coil 2500 VAC
Graph 2 Max. DC load Insulation Resistance @ 500VDC Min. 200 MΩ
Isolation, IEC 61810-5 2.5 KV / 3
10
Specifications
Operate / Release & Bounce Time Max. for DC 15+3 ms
Operate / Release & Bounce Time Max. for AC 16+8 ms
DC1
Mechanical Life ops. 10 Million AC, 20 Million DC relays
Electrical life at Nominal load ≥ 100,000 ops.
1
L/R 40ms
Operating Frequency at nominal load 1200 / hour
Amps
Volts 50 100 150 200 Ambient Operating Temperature -40°C to +55°C (for AC relay)
Ambient Operating Temperature -40°C to +70°C (for DC relay)
Protection Standard IP 40
Dimensions in mm. Weight app. 80 g
35 Standard Types
A1 14
AC : 6, 12, 24, 48, 110, 230
Coil:
2 3
24VDC M = Magnetic Blow Out
11 1 4 12 P = LED Indicator P3-Y-PM …. VAC
R = RC Circuit P3-Y-PRM …. VAC
35
21 8 5 22
7 6
48
52
Approvals
C US
9
13
P3-2T
2C/O Bifurcated Contacts
6 A 250V AC1 0.5 A 110V DC1
6 A 30V DC1 0.2 A 220V DC1
Contacts
Materials : Standard AgNi
Optional 1 AgNi + Au 0.2 µ
NC NO NC NO Optional 2 AgNi + Au 5.0 µ
4 3 5 6 2 Max. Switching Current 6A
12 14 22 24 A1 (+) Max. Peak Inrush Current (20 ms) 30A
Max. Switching Voltage 250 VAC
COIL Switching Power range 0.3 VA (W) to 2500 VAzC
Max. Contact Resistance 20m Ω
11 21 A2 (-) Max. AC Load (Table 1) 2.5 KVA
1 8 7 Max. DC Load (See Table 2) -
COM COM Coils (Ohms ± @ 20ºC)
Pull-in Voltage ≤ 0.8xUn
≥ 0.1xUn
Graph 1 Electrical life, ops x 10 6 Drop-out Voltage
Nominal Coil Power 1.6 VA (AC / 1.3 W (DC)
VAC Ohms VDC Ohms
6 3.15 6 33
12 13.3 12 116
24 52 24 480
46 240 46 1850
110 1120 110 9000
230 5600 220 29000
Insulation
Dielectric Strength (1 minute) : open contacts 1500 VAC
Between adjacent poles 2000 VAC
Between contacts and coil 2500 VAC
Graph 2 Max. DC load Insulation Resistance @ 500VDC Min.
Isolation, IEC 61810-5
200 MΩ
2.5 KV / 3
Specifications
Operate / Release & Bounce Time Max. for DC 8+3 / 3.5+8 ms
Operate / Release & Bounce Time Max. for AC 9+8 / 12+16 ms
Mechanical Life ops. 10 Million AC, 20 Million DC relays
Electrical life at Nominal load ≥ 100,000 ops.
Operating Frequency at nominal load 1200 / hour
Shock Resistance AK : > 10g
Vibration Resistance 5g 10…..150 Hz
Mounting Direction any
Storage -40°C to +85°C
Ambient Operating Temperature -40°C to +55°C (for AC relay)
Ambient Operating Temperature -40°C to +70°C (for DC relay)
Protection Standard IP 40
Weight app. 80 g
Dimensions in mm.
Standard Types
35
AC : 6, 12, 24, 48, 110, 230
T = Twin Contact
A1 14
F = Mechanical Flag Indicator P3-2T-F …. VAC
2 3
11
P = LED Indicator P3-2T-FP …. VAC
1 4 12
I = Lockable Push Button P3-2T-FPI …. VAC
R = RC Circuit P3-2T-FIR …. VAC
35
21 8 5 22
7 6 DC : 6, 12, 24, 48, 110 , 220
A2 24 F = Mechanical Flag Indicator P3-2T-F …. VDC
P = LED P3-2T-FP …. VDC
I = Lockable Push Button P3-2T-FPI …. VDC
W = Free Wheeling Diode P3-2T-FPWI …. VDC
Z = Polarity & Free Wheeling Diode P3-2T-FPZI …. VDC
B = AC/DC Bridge Rectifer P3-2T-FPIB …. VAD
52
48
51
C US
13
P3-2.....H
Long Life Relay 2C/O Contacts
10 A 250V AC1 0.5 A 110VDC1
10 A 30V DC1 0.2 A 220VDC1
Contacts
Materials : Standard AgNi
Optional 1 AgNi + Au 0.2 µ
NC NO NC NO Optional 2 AgNi + Au 5.0 µ
4 3 5 6 2 Max. Switching Current 10A
12 14 22 24 A1 (+) Max. Peak Inrush Current (20 ms) 30A
Max. Switching Voltage 250 VAC
COIL Switching Power range 0.3 VA (W) to 2500 VAz
Max. Contact Resistance 20m Ω
11 21 A2 (-) Max. AC Load (Table 1) 2.5 KVA
1 8 Max. DC Load (See Table 2) -
7
COM COM Coils (Ohms ± @ 20ºC)
Pull-in Voltage ≤ 0.8xUn
Drop-out Voltage ≥ 0.1xUn
Graph 1 Electrical life, ops x 10 6
Nominal Coil Power 1.6 VA (AC / 1.3 W (DC)
6 3.15 6 33
12 13.3 12 115
24 52 24 480
48 240 48 1850
110 1120 110 9000
230 5600 220 29000
Insulation
Dielectric Strength (1 minute) : open contacts 1500 VAC
Between adjacent poles 2000 VAC
Between contacts and coil 2500 VAC
Graph 2 Max. DC load Insulation Resistance @ 500VDC Min. 200 MΩ
Isolation, IEC 61810-5 2.5 KV / 3
Specifications
Operate / Release & Bounce Time Max. for DC 8+3 / 3.5+8 ms
Operate / Release & Bounce Time Max. for AC 9+8 / 12+16 ms
Mechanical Life ops. 10 Million AC, 20 Million DC relays
Electrical life at Nominal load ≥ 700,000 ops.
Operating Frequeny at nominal load 1200 / hour
Shock Resistance AK : > 10g
Vibration Resistance 5g 10…..150 Hz
Mounting Direction any
Storage -40°C to +85°C
Ambient Operating Temperature -40°C to +55°C (for AC relay)
Ambient Operating Temperature -40°C to +70°C (for DC relay)
Protection Standard IP 40
Weight app. 80 g
Dimensions in mm.
35
Standard Types
AC : 6, 12, 24, 48, 110, 230
H = Long Life Relay
A1 14
F = Mechanical Flag Indicator P3-2-F-H …. VAC
2 3
11
P = LED Indicator P3-2-FP-H …. VAC
1 4 12
I = Lockable Push Button P3-2-FPI-H …. VAC
R = RC Circuit P3-2-FIR-H …. VAC
35
21 8 5 22
7 6 DC : 6, 12, 24, 48, 110 , 220
A2 24 F = Mechanical Flag Indicator P3-2-F-H …. VDC
P = LED P3-2-FP-H …. VDC
I = Lockable Push Button P3-2-FPI-H …. VDC
W = Free Wheeling Diode P3-2-FPWI-H …. VDC
Z = Polarity & Free Wheeling Diode P3-2-FPZI-H …. VDC
B = AC/DC Bridge Rectifer P3-2-FPIB-H …. VAD
52
48
51
C US
P3-2.....E
6Amps Relays - 2C/O Contacts
6A 250V AC1 0.5 A 110V DC1
6A 30V DC1 0.2 A 220V DC1
Contacts
Materials : Standard AgNi
NC NO NC NO Optional 1 AgNi + Au 0.2 µ
4 3 5 6 2 Optional 2 AgNi + Au 5.0 µ
Max. Switching Current 6A
12 14 22 24 A1 (+) Max. Peak Inrush Current (20 ms) 30A
Max. Switching Voltage 250 VAC
COIL Switching Power range 0.3 VA (W) to 2500 VA
Max. Contact Resistance 20m Ω
11 21 A2 (-)
Max. AC Load (Table 1) 2.5 KVA
1 8 7 Max. DC Load (See Table 2) -
COM COM Coils (Ohms ± @ 20ºC)
Pull-in Voltage ≤ 0.8xUn
Graph 1 Electrical life, ops x 106 Drop-out Voltage ≥ 0.1xUn
Nominal Coil Power 1.6 VA (AC / 1.3 W (DC)
VAC Ohms VDC Ohms
6 3.15 6 33
12 13.3 12 115
24 52 24 480
48 240 48 1850
110 1120 110 9000
230 5600 220 29000
Insulation
Dielectric Strength (1 minute) : open contacts 1500 VAC
Between adjacent poles 2000 VAC
Between contacts and coil 2500 VAC
Graph 2 Max. DC load Insulation Resistance @ 500VDC Min. 200 MΩ
Isolation, IEC 61810-5 2.5 KV / 3
Specifications
Operate / Release & Bounce Time Max. for DC 8+3 / 3.5+8 ms
Operate / Release & Bounce Time Max. for AC 9+8 / 12+16 ms
Mechanical Life ops. 10 Million AC, 20 Million DC relays
Electrical life at Nominal load ≥ 100,000 ops.
Operating Frequeny at nominal load 1200 / hour
Shock Resistance AK : > 10g
Vibration Resistance 5g 10…..150 Hz
Mounting Direction any
Storage -40°C to +85°C
Ambient Operating Temperature -40°C to +55°C (for AC relay)
Ambient Operating Temperature -40°C to +70°C (for DC relay)
Protection Standard IP 40
Weight app. 80 g
Dimensions in mm.
Standard Types
35
AC : 6, 12, 24, 48, 110, 230
E = 6 Amps Relay
A1 14
F = Mechanical Flag Indicator P3-2-F-E …. VAC
2 3
11
P = LED Indicator P3-2-FP-E …. VAC
1 4 12
I = Lockable Push Button P3-2-FPI-E …. VAC
R = RC Circuit P3-2-FIR-E …. VAC
35
21 8 5 22
7 6
DC : 6, 12, 24, 48, 110 , 220
A2 24 F = Mechanical Flag Indicator P3-2-F-E …. VDC
P = LED P3-2-FP-E …. VDC
I = Lockable Push Button P3-2-FPI-E …. VDC
W = Free Wheeling Diode P3-2-FPWI-E …. VDC
Z = Polarity & Free Wheeling Diode P3-2-FPZI-E …. VDC
B = AC/DC Bridge Rectifer P3-2-FPIB-E …. VAD
52
48
51
35
24
A2
6
7
5
11 S8D 21
22
30
38
12
1
4
A1
3
2
14
Ø8.25
Ø3.20
59
63
Approvals
C US
S8D-YA Only
38 mm
WIDE
35
24
A2
6
7
11 S8D 21
30
38
1
A1
3
2
14
Ø8.25
Ø3.20
59
63
Approvals
C US
S8D-X Only
38 mm
WIDE
35
A2
7
5
11 S8D 21
22
38
30
1
A1
3
2
14
Ø8.25
Ø3.20
59
63
Approvals
C US
S8LD Only
38 mm
WIDE
Other Aspects
24 DIN Rail / Panel Mountable
Ø2.4 35 EN / DIN Sequential Numbering according to
Ø3.2 EN 60947 & IEC 61810
Integrated Relay Hold Down Clip
24
A2
6
21
5
8
38
S8-LD
12
11
4
1
A1
14
2
3
Ø6.0
53
57
Accessories
S8LD-B1
S8LD-B1
Dimensions in mm.
43.2
Approvals
S8LD-B1 C US
S8LD-YA Only
38 mm
WIDE
Other Aspects
4
21
2
A2
6
7
21
8
38
S8-LD-YA
11
1
A1
14
2
3
Ø6
53
57
S8LD-B1
S8LD-B1
43.2
Approvals
S8LD-B1 C US
S8LD-X Only
38 mm
WIDE
Other Aspects
2
2.2
38
S8-LD-X
11
1
A1
14
2
3
Ø6
53
57
S8LD-B1
S8LD-B1
43.2
Approvals
S8LD-B1 C US
Ordering Information
P3
1 2 3 4 5 6 7
6. Contact Material
Blank : AgNi
1. : AgNi + Au 0.2 µ (only for Twin contacts)
3. Contact Type 2. : AgNi + Au 5.0 µ (only for Twin contacts)
Blank : Single
T : Twin Contact
A. For Current coil please specify AC/DC coil current in place of coil voltage
B. Standard Frequency is 50 Hz for AC coil, for other frequency please specify frequency after coil voltage