b) The amount measured in kilocalories that a kilogram of fuel produces when burned.
c) The amount of heat produced by one cubic meter of fuel when burned.
According to the provisions of D.S. N° 10/2012 of the Ministry of Health, the turbidity of water is measured in:
According to what is established in D.S. N° 10/2012 of the Minsal, equipment that uses steam is considered:
Required pressure for the process, which may be equal to or less than the maximum working pressure of a boiler,
b) Working pressure
c) Design pressure
d) Gauge pressure.
When the boiler is installed in a basement and does not have direct communication with the outside, it must:
a) To have more than one mechanical air injection system in the room
c) It is the vapor that is produced and is in contact with the liquid that generates it without surpassing the evaporation temperature.
It is the vapor that is produced and is in contact with the liquid that produces it, exceeding the evaporation temperature.
Heating boilers and thermal fluid boilers must have the following observation accessories:
d) Only b and c.
a) Direct connection to the boiler body or to the hot water or thermal fluid outlet network
b) It must be marked with a visible and indelible red line the maximum and minimum working pressure.
c) They must be capable of indicating, at least, one and a half times the maximum working pressure, ensuring that this
Anywhere.
d) The minimum operating temperature must be marked with an indelible red line.
b) Failure of safety accessories and excess pressure Low water level and excess pressure
According to what is established in the D.S. No. 10/2012 of the Minsal, heating boilers must undergo the following
a) External and internal review, hydrostatic test, safety valve test, steam accumulation test
b) External and internal inspection, hydrostatic test, safety valve test, steam accumulation test,
none of the above, review of the steam distribution network, components and accessories, and special tests
c) External and internal review, verification of the operation of the relief valve and the thermostats, inspection of
d) External and internal review, hydrostatic test, safety valve test, accumulation test
b) At the end of any repair, reinforcement, or transformation and before putting it into service.
The verification of the operation of the relief or safety valves must be carried out:
a) At the end of the installation and before putting it into service
b) At the end of any repair, strengthening, or transformation and before putting it into service
b) At the end of any repair, reinforcement, or transformation and before putting it into service
According to what is established in D.S. No. 10/2012 of Minsal, the reviews and tests of the conditions
d) a and b.
Heating boilers
According to the provisions established in D.S. No. 10/2012 of Minsal, heating boilers are defined as:
This is graduated in Kg/cm2, how much should the new instrument read?
3.35 Kg/cm2
5.27 Kg/cm2
c) 9.41 Kg/cm2
d) There is no difference.
If a steam generator was manufactured to operate at a maximum pressure of 8 Kg/cm2, as indicated by the
design characteristic plate, and it is required to work at 10 Kg/cm2, what would you do?
What would you do if for any reason the water level disappears from the level tube below the lower level?
c) I would immediately halt the operation of the boiler and request a review of the boiler.
Every steam boiler must be equipped with at least these observation accessories:
a) 2 water level indicators, 1 pressure gauge and 2 gas outlet temperature meters
b) 1 water level indicator, 2 pressure gauges, and 2 gas outlet temperature meters
c) 2 water level indicators, 1 or more pressure gauges and 1 exhaust gas temperature meter
The inspections and tests performed on steam generators are conducted by:
d) They are only carried out in the first three years of boiler operation.
If the inspection and testing certificate of the steam generator is expired, what should you do?
b) The melting of a metal to evacuate the excess heat from the boiler
b) Decrease the vapor temperature below that of the saturated vapor, without increasing the pressure
c) Raise the temperature of the steam above that of saturated steam by increasing the pressure
d) Raise the temperature of the steam above that of saturated steam without increasing the pressure.
The quality of the feed water to a steam generator, according to the current regulations on the subject,
regarding the content of dissolved salts it indicates that:
pH from 7 to 11
The pressure at which the hydrostatic test must be performed on a steam generator is:
d) At design pressure.
b) The presence of calcium and magnesium carbonates, oils and fats accompanying the feed water.
c) The acidity that the water inside the boiler has is pH-5
In relation to the temperature and pressure parameters of water vapor, it is correct to say that:
a) If the gauge pressure rises, the temperature of the water vapor decreases.
b) The boiling temperature of water is higher when the gauge pressure is higher.
c) The boiling point of water is 100°C and it is not affected by the pressure exerted on the liquid.
The autoclaves that generate their own steam must have the following observation accessories:
a) 1 or more pressure switches for each pressure body, 1 temperature gauge for the chamber
b) 1 or more pressure gauges for each pressure body, 1 temperature gauge for the steam chamber, and 1 water level indicator
c) 1 or more thermostats for each pressure body, 1 temperature gauge for the steam chamber, and 1 water level indicator
The steam network or circuit can forgo the use of the pressure gauge:
c) The steam network or circuit must have at least one pressure gauge.
d) The steam network or circuit must have a pressure gauge every two meters of distance.
The flow regulating valves and pressure reducing valves must be located:
a) In the steam circuit or network in the least accessible part so that it does not cause annoyance
The areas or rooms where the heating boilers are installed must have:
c) a and b
Owner's name
d) Only b and c.
c) a and b
The authorized professional must carry out the following reviews, which will be recorded in the Life book:
c) Operation of the feeding system and water level control from the feed tank
The location of the heating boilers and thermal fluid boilers must
c) a and b
c) Avoid steam losses, drain condensates, remove air and other non-condensable gases
b) The amount of heat measured in kilocalories that is produced by burning one kilogram of fuel
d) a and c.
According to the provisions established in D.S N° 10/2012 of Minsal, the turbidity of water is not measured in:
c) Acidity
d) a and c.
a) Heating boiler
b) Steam boiler of any size and pressure greater than 0.5 Kg/cm2
b) At the end of any repair, reinforcement, or transformation and before putting it into service
According to what is established in D.S. No. 10/2012 of Minsal, the reviews and tests of the conditions
d) a and b.
Heating boilers
According to the provisions established in D.S. No. 10/2012 of Minsal, heating boilers are defined as:
a) True
b) False.
If a manometer reads a pressure of 5 Kg/cm2 and it needs to be replaced with another one, but graduated in Lb/plg2,
a) True
b) False.
In each work shift, the operator will check the operation of all devices at least once.
water supply, the safety valves will be activated and purges will be carried out:
a) True
b) False.
The calorific power of a combustible material is understood as the amount of heat it is capable of releasing.
a) True
b) False.
The boiler bottom purges can be discharged directly into the sewer if they have a good
water treatment
a) True
b) False.
The regulatory tests that must be performed on the boiler are every 5 years.
a) True
b) False.
A boiler room is required when it has a heating surface greater than 5 m2 and 2.5 kg/cm2 of pressure.
of work
a) True
b) False.
Heat is transmitted from a source in three ways: conduction, convection, and radiation.
a) True
b) False.
a) True
b) False.
The steam condensate from the return can be used as feed water for the boiler at all times.
a) True
b) False.
a) True
b) False.
a) True
b) False.
The heating surface of a boiler is; the surface in contact with the combustion gases and fumes.
on one side, and with the water on the other, this surface measured by the side that is in contact with the gases and fumes:
a) True
b) False.
a) True
b) False.
The fuse plug is a safety accessory that must be present in all large water volume boilers.
a) True
b) False.
Autoclaves do not need safety requirements to operate, as they are low-pressure equipment.
a) True
b) False.
a) True
b) False.
The steam network or circuit does not require having a connection pipe with a shut-off valve that allows the
a) True
b) False.
The steam network does not need to be inspected by the on-duty operator.
a) True
b) False.
a) True
b) False.
Radiation is the transmission of energy from a hot body to a colder one through space, without
a) True
b) False.
The directions and direction of the flow of the hot fluid should be marked with a green arrow and the flow.
a) True
b) False.
Non-combustible material room must not be equipped with fire extinguishing system:
a) True
b) False.
The traps do not provide operation under back pressure.
a) True
b) False.
To check the conditions of the heating boilers, they must be subjected to the following
inspections and tests, hydraulic test, steam test, accumulation test, and special tests when
a) True
b) False.
Gage pressure or effective pressure is the one measured by the manometer and corresponds to the pressure exerted by the vapor.
a) True
b) False.
The chamber of a boiler is the space between the maximum and minimum water levels:
a) True
b) False.
a) True
b) False.
Corrosions and deposits contribute to breaks and deformations in the boiler plates.
a) True
b) False.
All fuel must be stored in exclusive areas within the boiler room:
a) True
b) False.
Hard water and low pH cause scaling and oxidation in the boiler plates.
a) True
b) False.
If using liquid fuels contained in containers smaller than 1m3, they must be in
exclusive venues:
a) True
b) False.
The tank containing the liquid fuel must be labeled and have a vent valve towards
a) True
b) False.
The vapors that concentrate at the top of the initially empty container are known as
a) True
b) False.
Every boiler must have an attached metal plate indicating the manufacturer's name, factory number,
year of manufacture heating surface, maximum working pressure, working pressure and number assigned by the SNS.
a) True
b) False.
The boilers that use liquid or gaseous fuels shall be equipped with seals or gates devices to
pressure reliefs in the home and an automatic device that eliminates the risk of explosion:
a) True
b) False.
To verify the safety conditions of the generators, they must be subjected to the following checks
and tests: hydraulic tests, accumulation test, and special tests when requested by the health authority:
a) True
b) False.
To ensure the operation of a steam generator, it must have at least the following
a) True
b) False.
Small volume water boilers are those in which water flows inside the tubes.
a) True
b) False.
Enthalpy is the energy transferred due to the effect of one body or two bodies:
a) True
b) False.
a) True
b) False.
The health service is responsible for verifying compliance with the boiler regulations.
a) True
b) False.
A boiler must have a life book and a daily book according to the boiler regulation.
a) True
b) False.
Regulatory tests and reviews must be notified to the health authority 72 hours in advance.
a) True
b) False.
The deadline for the submission of technical reports by the authorized professional is 15 business days.
a) True
b) False.
a) True
b) False.
The expansion pond has the same characteristics as the retention pond:
a) True
b) False.
a) True
b) False.