You are on page 1of 4

LUMIOS Tunnel Entrance Photometer

LUMIOS

LUMIOS Tunnel Entrance Photometer


FEATURES BENEFITS

The LUMIOS uses a specially designed, highly light-sensitive photocell, filtered to provide a spectral response close to that of the average human eye, to react to changes in light levels at the entrance and exit to, as well as within, the tunnel environment. This reaction is virtually instantaneous. The light receptor measures the average luminance within an acceptance angle subtending 20, (as recommended by Commission Internationale de lEclairage (C.I.E.) Publication 88, 1990). The measurements are converted into an output signal of 4-20 mA (directly proportional to the luminance measurement) for hard wire connection and signal transmission to a host controller.
Safe stopping distance

SYSTEM COMPONENTS

APPLICATIONS OPERATION

Measurement of luminance, or brightness, created by natural light at the tunnel entrance / exit CIE Approved measurement technology Silicon photo diode, V filtered to provide a spectral response close to that of the average human eye Heated external enclosure with IP66 protection rating Operating temperature of -30 C to +70 C to ensure stable readings across all prevailing ambient temperature conditions Supplied complete with PC based utility software for set-up and control of the instrument

Designed specifically for monitoring tunnel portals Rugged design to withstand extremes of weather conditions Simple installation and mounting Optional wash-wipe facility to minimise maintenance requirements Flexible integration options
LUMIOS

The LUMIOS measures the level of luminance, or brightness, created by natural light at the tunnel entrance and/or exit to ensure that the visual perception of drivers will be maintained, both day and night, by avoiding sudden variations in lighting levels and potential black hole effect when entering and exiting a tunnel.
Tunnel Entrance

Mounted on a pole or gantry on the approach to the tunnel entrance

4-20mA Relay contacts Serial comms

20

LUMIOS sensor PC based utility software package for set-up and control of the instrument Optional adjustable wall or post / pole mounting brackets Optional wash-wipe facility

LUMIOS Tunnel Entrance Photometer

TECHNICAL SPECIFICATION INTERFACE OPTIONS PHYSICAL


Accuracy Voltage Parameter Measuring Principle Measurement Reading Measuring Angle Measuring Range Serial Comms Analogue Outputs Digital Relay Contacts

MEASUREMENT PERFORMANCE POWER REQUIREMENTS


Comment Luminance Silicon photo diode, V filtered 20 (degrees) 0 10,000 cd /m2 (user selectable) +/-3%

90 - 265 VAC / 50 60 Hz 6 10 W (incl. heater and wiper; excl. washer)

Nominal Current Consumption

ModBus RTU (RS485) 4.0 20.0 mA (isolated) 2 A @ 240 VAC or 3 A @ 60 VDC

Ambient Operating Temperature Operating Humidity Ingress Protection Materials Dimensions Weight

-30 - +70 C 0 100 % IP66 for external use Powder coated steel (stainless steel option available) 460 x 157 x 168 mm (measuring head) 4.5 kg (without optional wiper)

Call: +44 (0)1280 850563 E-mail: sales@tunnelsensors.com Visit: www.tunnelsensors.com

Tunnel Sensors A network of local distributors worldwide

Australasia Europe Far East Middle East South Africa North America South America

For further information about our product range please call +44 (0)1280 850563 or e-mail sales@tunnelsensors.com and a member of our team will be happy to help.
Tunnel Sensors Limited Furlong House Crowfield Brackley Northamptonshire NN13 5TW United Kingdom Telephone: +44 (0)1280 850563 Facsimile: +44 (0)1280 850568 E-mail: sales@tunnelsensors.com Visit: www.tunnelsensors.com

ISO 9001 Registered Firm


Certificate No. GB2002756

International Accreditation Board Registration No. 0044/1