Main Lightning Distribution Board
Main Lightning Distribution Board
B B
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
SHIPPING SECTION - 1 SHIPPING SECTION - 2 SHIPPING SECTION - 3 SHIPPING SECTION - 4 SHIPPING SECTION - 5 SHIPPING SECTION - 6
R Y B ON OFF TRIP R Y B ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP
V EM A VSS
V EM A ASS
A/M
SS
MF
160A TPN 160A TPN
A/M
SS
MF A/M
SS
MF
160A TPN 160A TPN
A/M
SS
MF A/M
SS
MF
160A TPN 160A TPN
A/M
SS
MF
300
VSS ASS MAIN D.G. D.G.
160A CONT. MCCB MCCB 160A CONT. 160A CONT. MCCB MCCB 160A CONT. 160A CONT. MCCB MCCB 160A CONT.
IN IN ON STARTER FUEL LLOP HTC BAT.
C C
(INSIDE) (INSIDE) (INSIDE) (INSIDE) (INSIDE) (INSIDE)
STARTER
ON
FUEL
ON
RESET
ON
START
P/B
AMF ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP
MF MF MF MF MF MF
A/M
SS
160A TPN 160A TPN
A/M
SS
A/M
SS
160A TPN 160A TPN
A/M
SS
A/M
SS
160A TPN 160A TPN
A/M
SS 300
160A CONT. MCCB MCCB 160A CONT. 160A CONT. MCCB MCCB 160A CONT. 160A CONT. MCCB MCCB 160A CONT.
(INSIDE) (INSIDE) (INSIDE) (INSIDE) (INSIDE) (INSIDE)
TNC TNC
SWITCH SWITCH ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP
MF MF MF MF MF MF
A/M
SS
160A TPN 160A TPN
A/M
SS
A/M
SS
160A TPN 160A TPN
A/M
SS
A/M
SS
160A TPN 160A TPN
A/M
SS 300
160A CONT. MCCB MCCB 160A CONT. 160A CONT. MCCB MCCB 160A CONT. 160A CONT. MCCB MCCB 160A CONT.
D ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP
D
MF MF MF MF MF MF
CABLE CABLE
A/M
SS
160A TPN 160A TPN
A/M
SS
A/M
SS
160A TPN 160A TPN
A/M
SS
A/M
SS
160A TPN 160A TPN
A/M
SS 300
ALLEY ALLEY 160A CONT. MCCB MCCB 160A CONT. 160A CONT. MCCB MCCB 160A CONT. 160A CONT. MCCB MCCB 160A CONT.
(INSIDE) (INSIDE) (INSIDE) (INSIDE) (INSIDE) (INSIDE)
2.5 KVA 2.5 KVA ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP ON OFF TRIP
415/110V 415/110V
MF MF MF MF MF MF
TRANS-
FORMER
TRANS-
FORMER
A/M
SS
160A TPN 160A TPN
A/M
SS
A/M
SS
160A TPN 160A TPN
A/M
SS
A/M
SS
160A TPN 160A TPN
A/M
SS 300
160A CONT. MCCB MCCB 160A CONT. 160A CONT. MCCB MCCB 160A CONT. 160A CONT. MCCB MCCB 160A CONT.
(INSIDE) (INSIDE) (INSIDE) (INSIDE) (INSIDE) (INSIDE)
200 200
E E E
75 75
800 800 350 500 300 500 350 350 500 300 500 350 350 500 300 500 350
E 800
E
7600 SIDE VIEW
BOTTOM VIEW
[Link] MINES /118205/CAP/4700124323
G G
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
B B
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
SHIPPING SECTION - 1 SHIPPING SECTION - 2 SHIPPING SECTION - 3 SHIPPING SECTION - 4 SHIPPING SECTION - 5 SHIPPING SECTION - 6
ACB
300
300
D D
300
300
200 200
E E E
75 75
800 800 350 500 300 500 350 350 500 300 500 350 350 500 300 500 350
E 800
E
7600 NOTES
SIDE VIEW
BOTTOM VIEW
[Link] MINES /118205/CAP/4700124323
G G
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
B B
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
SHIPPING SECTION - 6 SHIPPING SECTION - 5 SHIPPING SECTION - 4 SHIPPING SECTION - 3 SHIPPING SECTION - 2 SHIPPING SECTION - 1
ACB
300
300
D D
300
300
200 200
E E E
75 75
350 500 300 500 350 350 500 300 500 350 350 500 300 500 350 800 800
E 800
E
7600 SIDE VIEW
NOTES
REAR VIEW 1. SHEET THICKNESS ( CRCA)
a) BODY & LOAD BEARING MEMBERS : 2 mm
b) DOORS & NON LOAD BEARING MEMBERS : 1.6 mm
c) GLAND PLATE : 3 mm
2. CABLE ENTRY : - BOTTOM
3. MOUNTING : FLOOR
4. BUSBAR : - ALLUMINIUM PVC SLEEVED COLOUR CODED
COLOUR CODED(63401NP2)
800 5. PAINT : - SIEMENS GREY POWDER COATED
6. ALU. BUSBAR : - 125 X 10 X 3 - 3 NO. FOR PHASE
F 7. ALU. BUSBAR : - 125 X 10 X 2 - 1 NO. FOR NEUTRAL F
8. ALU. BUSBAR : - 50 X 10 X 1 - 1 NO. FOR EARTHING
9. ALL DOOR HAVING EARTHING BOLT
10. PROTECION CLAS WILL BE IP - 52.
7600
PANEL SIZE : - 7600 MM (W) X 2375 MM (H) X 800 MM (D)
BOTTOM VIEW
[Link] MINES /118205/CAP/4700124323
G G
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QTY : - 01 NO.
ALL THE INFORMATION CONTAINED IN THIS DOCUMENT IS CONFIDENTIAL AND COPYRIGHT THEREOF IS RESERVED
B TO AUX.
B
TO AUX. CONTROL
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
CONTROL
TO
TO TRAFO CONTROL
CONTROL
MPCB 2A MPCB 2A
R Y B R Y B
AMF
MPCB 2A MPCB 2A
MPCB
START START START START START START START START START START START START
STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP
A/M A/M A/M A/M A/M A/M A/M A/M A/M A/M A/M A/M
F
FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER
DESCRIPTION
KW / RATING
G CABLE SIZE
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QTY : - 01 NO.
ALL THE INFORMATION CONTAINED IN THIS DOCUMENT IS CONFIDENTIAL AND COPYRIGHT THEREOF IS RESERVED
B
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
C
25X3, 110V, 50 HZ, CU. BUS BAR TRAFO. CONTROL BUS
E START START START START START START START START START START START START
STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP
A/M A/M A/M A/M A/M A/M A/M A/M A/M A/M A/M A/M
FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER
QTY : - 01 NO.
ALL THE INFORMATION CONTAINED IN THIS DOCUMENT IS CONFIDENTIAL AND COPYRIGHT THEREOF IS RESERVED
B
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
START START START START START START START START START START START START
STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP
A/M A/M A/M A/M A/M A/M A/M A/M A/M A/M A/M A/M
FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER FEEDER
2A SP
A
MCB
M DRAWING NO. AS - 0029 A
N/L
QTY : - 01 NO.
PT-1 (415/230)V
ALL THE INFORMATION CONTAINED IN THIS DOCUMENT IS CONFIDENTIAL AND COPYRIGHT THEREOF IS RESERVED
2A 2A
MPCB MCB
B 1 2 B
2A
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
3 4
MCB V
S V (0 - 500V)
2A S
MCB
5 6
AUX
N/L SUPPLY
FROM
PT-5
C C
AUX
SUPPLY
FROM
PT-5 AUX
SUPPLY
FROM
PT-5
N B Y R P N
C.T.
S1 S1 S1 S2 S2
1250/5 A
CL 1,15 VA S2 A
A (0 - 1250A)
N C.T.
1250/5 A
CL 1,15 VA
S1
S2
S1 S1
EM S2 S2
S
S
C.T.
D 1250/5 A
CL 1,15 VA
S1
S2
S1 S1 S2 S2
D
E
PLC COM.
N 15 3
B 18 22 (X7)
VMR
E Y
28
K9-1 E
R R A1
25 K9
N R Y B
PT-2 1250A A2
415/230 V FP ACB
50KA
COTROL 2A
16A
MPCB
R
TRANSFORMER MPCB-1
R
N
F R R Y B R
Y Y F
Y
B B
B
Y
N
N/L
N
TO UV COIL
MPCB-3
G G
AS PER
MIDC,HINGNA ROAD,NAGPUR
H 2 03/07/2023 COMMENTS
CLIENT JSW STEEL LTD. ODISHA MINES. APPROVED BY SHEET 3 H
AS PER
3 28/8/2023 MEETING APPROVED BY DRAWING NO. AS - 0029
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
B
R Y K11
ALL THE INFORMATION CONTAINED IN THIS DOCUMENT IS CONFIDENTIAL AND COPYRIGHT THEREOF IS RESERVED
16A DP
B R1
B
MCB A1 A2
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
R1 Y1
2A
PT-3 (415/230)V 2A
MCB
MPCB
1 2
V
3 4 Y1
S V (0 - 500V)
S PT-5
5 6 415/230 V
AUX
N/L SUPPLY
FROM
C E
PT-5 16A DP C
MCB
E B 18 25 (X10)
K10-R
VMR 28
Y
E E
25 R
R
A1
K10
N R Y B
PT-4 1250A A2
415/230 V FP ACB
50KA
COTROL 2A
MPCB
16A
TRANSFORMER R
F R
MPCB-2
N R Y B R
R F
Y
Y Y
B B
Y B
N
N/L
N
TO UV COIL
MPCB-4
G G
AS PER
MIDC,HINGNA ROAD,NAGPUR
H 2 03/07/2023
COMMENTS
CLIENT JSW STEEL LTD. ODISHA MINES. APPROVED BY SHEET 4 H
AS PER
3 28/8/2023 MEETING
APPROVED BY DRAWING NO. AS - 0029
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
CLOSING CIRCUIT FOR MAIN POWER ACB DRAWING NO. AS - 0029
QTY : - 01 NO.
ALL THE INFORMATION CONTAINED IN THIS DOCUMENT IS CONFIDENTIAL AND COPYRIGHT THEREOF IS RESERVED
16A 2A SP
B MPCB-3 MCB
230V AC B
MR1 SUPPLY
R FROM
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
FROM EB
CONTROL MN
I/C SUPPLY B MR1
BUS
B E/PB
NC
MR5
MR1 MR1 MR1 MR1 MR1 MR1 PHASE
C M-R1 C
K9
X1
FUTURE
INTERLOCKING
X2
I/C
MR5-A ACB NO L/SW
SPRING
M-R3 ACB NC K1
CHARGE
K1 ACB
MR5-A
D K1 D
AUX. A/M P1
CONT. S/S-1
NO
A M MN MR10 MR11 MR12 MR18 MR15 SPRING
MR6 MR7
CHARGE
MOTOR
M
M-R4
MR7
DG RL1 T
ACB N
NC C
MR8 MR8
E M-R5 E
D.G.
ACB
UV
NC
COIL MR9
ACB
ANTI
PUMPING
F F
MR6 MR16 K1 NEUTRAL
K3 K4
CLOSING
K2 COIL
ACB
MN MN MN MN MN MN MN MN MN
MN
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
MAIN POWER ACB TRIPPING CIRCUIT DRAWING NO. AS - 0029
DP 6A
MCB
FROM P MR1
QTY : - 01 NO.
CONTROL N MN MR1 MR1 MR1 MR1 MR1 MR1 MR1
BUS 181
13 T
X3 FUTURE
E/PB
ALL THE INFORMATION CONTAINED IN THIS DOCUMENT IS CONFIDENTIAL AND COPYRIGHT THEREOF IS RESERVED
14
184
C C
D D
MR14
E MAIN POWER E
ACB
NO
MR17
MN
G G
A A
CLOSING CIRCUIT FOR DG ACB
DRAWING NO. AS - 0029
QTY : - 01 NO.
ALL THE INFORMATION CONTAINED IN THIS DOCUMENT IS CONFIDENTIAL AND COPYRIGHT THEREOF IS RESERVED
16A 2A SP
B MPCB-4 MCB
230V AC
B
DR1
FROM DG R
FROM SUPPLY
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
CONTROL DN
I/C SUPPLY DR1
B BUS
B E/PB
NC
DR5
C D-R1 21
C
K10
X1 22 DR1 DR1 DR1 DR1 DR1 P
FUTURE
INTERLOCKING 41 41 MR1
X2 B1
DR5-A ACB NO I/C
K5 SPRING K5
D-R3 ACB NC NO NO L/SW
CHARGE
ACB
DR5-A
42 44 B2
D K5 A/M
DR10 DR11 DR12 DR18 DR15 P1 D
AUX. S/S-1
CONT. A M
NO SPRING
DR6 DR7 CHARGE
MOTOR
M
D-R4 DR7
T
RL2
MAIN POWER N
ACB C
NC DR8 DR8
E D-R5 EB
E
ACB
UV NC
COIL DR9
ACB
ANTI
PUMPING
DR1
CLOSING DN
K6
COIL
ACB
DN DN DN DN DN DN DN DN MN MN
DG TRIPPING CIRCUIT
A DRAWING NO. AS - 0029 A
DP 6A
FROM MCB QTY : - 01 NO.
P DR1
CONTROL
N DN DR1 DR1 DR1 DR1 DR1 DR1 DR1
BUS 181 X3 FUTURE T
ALL THE INFORMATION CONTAINED IN THIS DOCUMENT IS CONFIDENTIAL AND COPYRIGHT THEREOF IS RESERVED
B E/PB MAIN 13 B
POWER INTER N
NO LSIG RL4 K10 X4
LOCK
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
ACB C
14
184 OFF
DR14 DR14 DR14 DR14 DR14 DR14 DR14
C C
D D
DR14
E E
DG
ACB
NO
DR17
F F
DG ACB
TRIPPING COIL
SHUNT TRIP
DN
G G
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
B B
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
1 2
24V A
DC V A/M
FROM 0 S/S-1 2
SMPS AUTO MANUAL
3 4
C C
3 3 3 3 3 3 3 4 3 4 3 3 3
PLC STOP
DO0 DO1 DO2 DO3 DO4 DO5 START DO6 DO7 DO8 DO9
AUX PB
PB
D SUPPLY D
0
5 6 7 8 9 10 11 12 13 14
0 0 0 0 0 0 0 0 0 0
G G
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
QTY : - 01 NO.
B B
3
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
3 3 3 3 3 3 3 3 3
X5 X7 X9 X15
DG ENG.
K4 K8 VMR K11 DG VMR
C
AMF C
X6 X8 X10 X16
15 16 17 18 21 22 23 24 25
D
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
M-11
X5 SPARE 20 M-14 21 MAIN POWER ACB ON FDBK TO MAIN PLC
X6 EMERGENCY TRIP
DG OFF
D-31 D-32
X7 MAIN POWER OV/UV OPRATED 23 24 DG OFF TO MAIN PLC
PLC O/P
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
N
FROM R DRAWING NO. AS - 0029
A MAIN A
Y
BUS B QTY : - 01 NO.
MAIN
MCCB
K1 2A SP
MCB
ALL THE INFORMATION CONTAINED IN THIS DOCUMENT IS CONFIDENTIAL AND COPYRIGHT THEREOF IS RESERVED
N B Y R
B B
R
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
A1
K2
A2
N
AUX
C SUPPLY
FROM
C
PT-5
N B Y R P N
C.T.
160/5 A S1 S1 S1 S2 S2
CL 1 10 VA S2
N C.T.
160/5 A
CL 1 10 VA
S1
S2
S1 S1
MF S2 S2
C.T.
160/5 A S1 S1 S1 S2 S2
D CL 1 10 VA S2 D
SP 2A
MCB
P P
E E
N N
N R Y B
K1 K1 Q1
Q1 TP
F MCCB L1 L2 L3 F
ON OFF TRIP
N P
G N R Y B G
FROM COTROL FROM BUSBAR
TRANSFORMER
SUPPLY
REV. DATE MODIFICATION MAIN LIGHTING DRAWN BY ANUSHRI SCALE IN MM
TITLE DISTRIBUTION BOARDS MANUFACTURED BY : - M/S RAHSAN ENGINEERING
1 04/06/2023 (METERING 3 DRAWING) WORKS : - 28A & 29B, MOHITE INDUSTRIAL ESTATE CHEKED BY SANDEEP DATE 03/07/2023
AS PER
MIDC,HINGNA ROAD,NAGPUR
H 2 03/07/2023 COMMENTS CLIENT JSW STEEL LTD. ODISHA MINES. APPROVED BY SHEET 11 H
3 AS PER
28/8/2023
MEETING APPROVED BY DRAWING NO. AS - 0029
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
R 1
FROM K2
ALL THE INFORMATION CONTAINED IN THIS DOCUMENT IS CONFIDENTIAL AND COPYRIGHT THEREOF IS RESERVED
B
CONTROL NL 1-1
B
BY M/S. RAHSAN ENGINEERING. AND SHALL NOT BE COPIED OR PRODUCED WITHOUT WRITTEN PERMISSION .
BUS
N AUTO MANUAL
1 1
2
3
C C
K1 Q1
ON OFF FROM STOP
PLANT PLC P/B
L2 L3
D D
START NO
P/B CONT.
MCCB ON
15 14
8 7
L1
MCCB OFF
F 6
16 14
5
F
A1
K3
A2
G
K1 ON OFF TRIP G
1 2 3 4 5 6 7 8