Uninterruptible Power Supplies: John Liguori Consulting Engineer Msee, Pe
Uninterruptible Power Supplies: John Liguori Consulting Engineer Msee, Pe
JOHN LIGUORI
CONSULTING ENGINEER
MSEE, PE
INTRODUCTION
POWER DISTURBANCES
UNINTERRUPTIBLE POWER SUPPLIES
GENERAL DISCUSSION
SUMMARY
REFERENCES
QUESTIONS
INTRODUCTION
PURPOSE
WHAT IS AN UNINTERRUPTIBLE POWER SUPPLY?
WHY USE A UPS?
PURPOSE
POWER DISTURBANCES
CAUSES
TYPES
DURATION
RESULTING PROBLEMS
COMMENTS
WHAT THE POWER UTILITY CAN DO
WHAT THE ORIGINAL EQUIPMENT MANUFACTURER (OEM)
CAN DO
WHAT YOU CAN DO
PROTECTIVE DEVICES
INTERRUPTION
SAG, UNDER VOLTAGE
SURGE, OVER VOLTAGE
VOLTAGE FLUCTUATION
FREQUENCY VARIATION
SPIKES / TRANSIENTS
IMPULSIVE
OSCILLATORY
WAVEFORM DISTORTION
DC OFFSET
HARMONICS
INTERHARMONICS
NOTCHING
NOISE
VOLTAGE IMBALANCE
10
INSTANTANEOUS
MOMENTARY
TEMPORARY
SUSTAINED
11
DISRUPTIVE
EQUIPMENT DOES NOT OPERATE AS INTENDED
DISSIPATIVE
EQUIPMENT EXPERIENCES REPEATED STRESSES THAT LEAD TO FAILURE
LATER FOR NO APPARENT REASON
DESTRUCTIVE
EQUIPMENT FAILS AT THE INSTANT THE DISTURBANCE OCCURS
12
DATA ERRORS
DATA LOSS
BLOWN FUSES
TRIPPED BREAKERS
INTERFERENCE WITH CONTROL OF LOADS
OVERLOADED NEUTRAL CONDUCTORS
MOTORS
HEATING
SPEED VARIATION
STALLING
AUDIBLE NOISE
VIBRATION
TRANSFORMERS
HEATING
AUDIBLE NOISE
VIBRATION
13
14
15
16
SURGE PROTECTORS
LINE FILTERS
ISOLATION TRANSFORMER
VOLTAGE REGULATING LINE CONDITIONER
UPS
17
LINE FILTERS
FILTERS OUT HARMONICS, TRANSIENTS AND NOISE
ISOLATION TRANSFORMER
ELIMINATES DC OFFSET AND NOISE
POWER DISTURBANCES
AND
PROTECTIVE DEVICES
19
UPS
ARCHITECTURES
WAVEFORMS
INVERTER TECHNOLOGY
COMPONENTS
SWITCHOVER TIME
ADVANTAGES / DIS-ADVANTAGES
SIZING
BATTERY SAFETY
20
UPS ARCHITECTURES
LINE INTERACTIVE
ON-LINE
21
BLOCK DIAGRAM
LINE INTERACTIVE UPS
AUTOMATIC
SWITCH
AC SUPPLY
BATTERY
CHARGER
CRITICAL
LOAD
(AC)
INVERTER
DC TO AC
BATTERY
AC FAIL
22
BLOCK DIAGRAM
ON-LINE UPS
AUTOMATIC
SWITCH
AC SUPPLY
CONVERTER
AC TO DC
INVERTER
DC TO AC
CRITICAL
LOAD
(AC)
BATTERY
INVERTER FAIL
23
BLOCK DIAGRAM
LAPTOP COMPUTER POWER SUPPLY
CRITICAL
LOAD
AC SUPPLY
CONVERTER
AC TO DC
CONVERTER
DC TO DC
(DC)
BATTERY
24
UPS WAVEFORMS
TRUE SINEWAVE
MODIFIED SINEWAVE
SQUARE WAVE
25
UPS WAVEFORMS
26
27
BLOCK DIAGRAM
PWM INVERTER
DC POWER
HIGH
FREQUENCY
GENERATOR
PULSE WIDTH
MODULATOR
BASE /
GATE
DRIVE
COMPARISON
AMPLIFIER
TRANSISTOR
BRIDGE
TRANSFORMER
FILTER
CRITICAL
LOAD
(AC)
REFERENCE
SINEWAVE
GENERATOR
28
BLOCK DIAGRAM
LINEAR AMPLIFER INVERTER
DC POWER
SINEWAVE
OSCILLATOR
TRANSFORMER
CRITICAL
LOAD
(AC)
OSCILLATOR
AMPLIFIER
COMPARISON
AMPLIFIER
POWER
AMPLIFIER
29
BLOCK DIAGRAM
RESONANT INVERTER
DC POWER
SQUARE
WAVE
GENERATOR
SWITCH
DRIVE
TRANSISTOR
SWITCHES
TRANSFORMER
LC RESONANT
TANK FILTER
CRITICAL
LOAD
(AC)
(OR FERRORESONANT)
30
UPS COMPONENTS
CONVERTER - AC TO DC
SPD - PROTECTS AGAINST SPIKES AND TRANSIENTS
BATTERY
STORED ENERGY DEVICE - PROTECTS AGAINST INTERRUPTIONS
INVERTER DC TO AC
WAVEFORM SYNTHESIS PROTECTS AGAINST DC OFFSET AND
INTERHARMONICS
FILTER PROTECTS AGAINST HARMONICS, NOTCHING AND NOISE
VOLTAGE REGULATOR PROTECTS AGAINST SAGS, SURGES AND
FLUCTUATIONS
31
SWITCHOVER TIME
2 4 ms
32
ON-LINE ADVANTAGES
ZERO SWITCHOVER TIME FROM MAIN LINE TO BATTERY POWER
ALWAYS ISOLATED FROM POWER DISTURBANCES ON THE MAIN LINE
33
TOTAL UPS LOAD MUST NOT EXCEED THE UPS VOLT AMP (VA)
RATING
TOTAL UPS LOAD MUST NOT EXCEED THE UPS WATT (W)
RATING
OVERSIZE / DERATE TO ADD LIFE
RUNTIME CHARTS
34
35
BATTERY SAFETY
MAINTENANCE
INSPECT PERIODICALLY
REPLACE AS NEEDED
RISKS
ACID
ELECTRIC SHOCK
BURN
FLYING, MOLTEN METAL (EYES)
INJURIES RESULTING FROM CARRYING HEAVY BATTERY PACKS
DISPOSAL
DISPOSE OF PROPERLY
RECYCLE WHENEVER POSSIBLE
36
GENERAL DISCUSSION
37
UPS FAILURE
38
39
MISCELLANEOUS
40
SUMMARY
THINGS TO CONSIDER WHEN SPECIFYING A UPS
POWER QUALITY
ARCHITECTURE - LINE INTERACTIVE OR ON-LINE
WAVEFORM - SQUARE, MODIFIED SINE, TRUE SINE
IMMUNITY TO DISTURBANCES OTHER THAN OUTAGE
INITIAL COST
MAINTENANCE COST
WARRANTY
41
REFERENCES
42
QUESTIONS
43