SUMBAGUT, August2016

SUMBAGUT
Badspot & Bad event
CLUSTER -3

Sumbagut Summary Cluster-3

2G Cluster-3

Cluster

Cluster 3

2G NE

Start and End Point in Drive routes marked with different Color.

Badspot Cluster 3

3
7
4

8
5
6
9

Badspot-1
2G By CI
BIR228

BIR220

BIR352

Bad Rxlevel suspect overshoot site BIR352D and site BIR220D covering residential and have active alarm action:
propose audit site BIR352D, BIR220D and raise HCR

Badspot-2
2G By
CI

BIR228
2.1
k

Bad Rxlevel suspect site BIR228 over downtilt action: propose uptilt site BIR228

Badspot-3

BIR401

BIR148

Bad Rxlevel suspect no dominant site covering and site BIR401 over downtilt. Action audit for uptilt site BIR401

Badspot-4
2G By
CI

BIR148

1.47k
m

BIR338

Bad Rxlevel suspect site BIR338G no serving when drive test and site BIR148 overdowntilt action: propose audit site
BIR148

Badspot-5
BIR381

2G By
CI

BIR089

BIR253

BIR397

Bad Rxlevel suspect site BIR381 overshoot and site BIR089 no serving when drive test, site BIR397 over downtilt and site
BIR253 have blocking due to hilly contour. Action audit site BIR381 & BIR397

Badspot-6
BIR395

Bad Rxlevel suspect blocking hilly contour, power site BIR395 already max, action: propose newsite

Badspot-7
2G By
CI

BIR369

BIR118

LHK314

BIR233

Bad Rx level due to site BIR118D over downtilt action: propose uptilt site BIR118D

Badspot-8
BIR185

4.
5

km

LHK014

BIR094

Bad Rxlevel suspect site BIR185D sleeping cell sect F. Action: raise HCR & reazimuth site LHK014

Badspot-9
BIR236
BIR053

Bad Rx level suspect non GSM covered, site BIR053 state halted and nearest GSM cant cover due to blocking hilly.
Action: maximized power site BIR236

Event 2G (DROP, BLOCK and HANDOVER FAIL)

1
2

Report Generator

Bad event 1

Blocked call on site BIR228 suspect low rx level. Action: audit site BIR228

Bad event 2

Blocked call on site BIR052 suspect overshoot. Action: audit site BIR052