Introduction
> Design for double storey house
Consist of designing :
1. Slab
2. Beam
3. Staircase
4. Column
5. Pad Footing
Slab Design
Ground floor Slab (GF-fs7)
Dimension = 1700mm x 1200mm
One-way slab
One short edge discontinue
Total Design Load = 8.9 KN/M
Key Plan
Msx1 = 0.53KNM
Msx2 = 0.713KNM
Effective depth =
85mm
Long Span
Msy1 = 0.39KNM
Msy2 = 0.474KNM
Effective depth =
85mm
Short
Med Span
= 0.713knm/m
Z = 0.95d
AS,Req =20.3mm
As,prov = 314mm
(10H-200)
As,min = 114.92 mm
As,Max = 5000mm
As,min < As,prov <
As, Max
OK!
Long
MedSpan
= 0.474knm/m
Z = 0.95d
AS,Req =13.49 mm
As,prov = 314mm
(10H-250)
As,min = 114.92 mm
As,Max = 5000mm
As,min < As,prov <
As,, Max
OK!
Shear Design
Short span
Vsx1 = 4.85KN
Vsx2 = 0 KN
Short span
Vsy1 = 3.85KN
Vsy2 = 2.56KN
Ved = 4.85 kn
K = 0.0036
VRd,c = 42.43
KN
Vmin = 42.07
KN
VRd,c > Ved
= 14.12
allowable = 3081.95
actual < l/d allowable
actual
Cracking
H = 125
Main bar = 375mm
< 400mm
Sec Bar = 437.5
mm < 450 mm
Safe from cracking
Detailing
Beam design
Pad Footing
Design
Data
Footing
size Estimation 1.6 m 1.6 m
Soil
pressure at ultimate load
= 90.51 kn/m
Soil pressure per meter length, 144.86 kn/m
Movement at level arm,=0.6 m
Maximum moment at the force of the
column
M = 26.08 knm
Main Reinforcement
Minimum
Vertical Shear
Design
Punching Shear
Critical
perimeter,
Critical area within perimeter = 2.16
Punching shear force, = 36.22 kn
Punching shear stress, = 0.024 N/
Shear force resistance, =0.43 N/
<
Max
Cracking
Fs
= 626.11 N /
Max bar spacing = 504.67 mm > 225
mm :fail!!
Change mainbar to 8H10 = 217.14
mm