You are on page 1of 56

Wireless 3900 Series Base

Station Hardware Installati


on
www.huawei.com

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Contents
1 Installation Scenarios and Exam
ple
2 Installation Technical key point

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page2

Installation scenarios
Typical

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Antenna Feeder System


Antenna

Jumper cable
Lightning protection ground clip

Feeder cable
Equipment room
Cable ladder
Jumper cable

BTS
Tower

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page 4

Equipment Room Inside


Air
conditioner
Cable
ladder
Equipment

PDF

alert
Battery
Lamp
PGND
Main-attached of
chamber inside

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page5

Products of the 3900 Series Base Statio


n

Outdoor Macro Base Station


Indoor Macro Base Station
Distributed Base Station
Mini Base Station

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page6

HUAWEI Main Base Station Description


Indoor
eNodeB
BTS3900

Outdoor eNodeB
BTS3900A

RFU

Multi-modal RRU
60W/4C
CDMA/WCDMA/LTE
GSM/UMTS/LTE

Distributed
eNodeB
DBS3900

RRU

BBU

Multi-modal BBU
2U 19-in rack mount
design
Use to 2G/3G/4G
operation

Huawei Fourth Generation Base Station

Three standardized modules shared by all Sites portfolio

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page 7

DBS3900 Overview

The DBS3900 consists of the BBU, RRUs and the other eq


uipments.
DBS3900

Antenna
system
Power
Transmissi
on

BBU

RRU

Environme
nt
Monitoring
etc.

Site supplementary equipments

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page8

BBU3900 Physical Structure


[fizikl]

WBBP/UBBP/LBBPUELP WMPT/UMPT
UPEU
FAN
BBU3900 consists of the following subsystems: baseband
subsystem, cabinet subsystem, transmission subsystem,
interconnection subsystem, main control subsystem, monitoring
subsystem, and clock subsystem.
Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Page 9

BBU3900
Configuration(normal)
BBU layout

In any scenario FAN UPEU UEIU boards are in the fixed slot

( )

(Max)
board type board name) (if integrant)
configuration order priority from left to right)

FAN

FAN

Yes

slot16

Power board

UPEU

Yes

slot19 slot18

monitoring)

EUIU

NO

slot18

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page10

BBU3900 Configuration(GBTS
scenario)

BBU typical configuration

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page11

BBU3900 Configuration(UMTS
scenario)

BBU typical configuration

Slot3 Slot2 UMTS CPRI WBBPd WBBPf UBBPd_U


Slot3 Slot2 UBBPd_U>WBBPf>WBBPd

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page12

BBU3900 Configuration(LTE
scenario)

BBU typical configuration

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page13

BBU3900 Configuration(Single RAN)

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page14

BBU3900 Configuration(Single RAN)

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page15

RRU Physical Structur


e
Indicator

[ndket]

CPRI
interface

Interconnect
interface
Power
connector
RET CONNECTOR
ANT Tx/Rx

PGND

ANT Rx

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Page 16

RRU3942

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page17

DBS3900 Typical Installation Scenarios


BBU and RRU centralized
installed in indoor IFS06
rack

BBU installed in indoor cabinets &


RRU mounted on outdoor pole
BBU installed in outdoor cabinets &
RRU mounted on tower

BBU installed on indoor wall &


RRU mounted on outdoor wall

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page18

Installation scenarios

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

BBU Installation scenarios


Outdoor Cabinet
Indoor in the Rack
Inside APM30H
cabinet

on the Wall
Indoor on the Wall

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Page 20

RRU Installation scenarios 1


The RRUs can be installed on the pole, on the wall and in
the L-Rack and so on

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Page 21

RRU Installation scenarios 2


Para el proyecto RAN 2015-2016, todas las RRU sern
Blade RRU, y sern instaladas en modo concentrado para
ahorrar pipes y espacio.

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Page 22

Cable de Energa de la RRU


Se deben usar terminales OT para la conexin de los equipos. En el extremo de
la RRU el blindaje del cable debe ser aterrizado al chasis del equipo, para lo
cual debe ser descubierto segn se muestra en la siguiente figura:

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page23

Solucin del Producto Proyecto RAN


2015 2016.

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page24

Reglas de conexiones de energ


a (Caso ms complejo)

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page25

Consumo de energa y Requerimi


ento de Breakers
Power Scenario
No.

Description

Scenario

Scenario_P1
Scenario_P2

3*RRU+1*BBU
6*RRU+1*BBU

Scenario_P3

9*RRU+1*BBU

Scenario_P4

12*RRU+1*BBU

850M
850M+1900M
850M+1900M+2
600M
850M+1900M+2
600M+700M

Typical Power(W)

Maximum
Power(W)

883.71
1723.37

1440.59
2722.18

2543.96

3772.6

3263.96

4732.6

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page26

RUTEO DE CABLES OPTICOS Y ELEC


TRICOS
La fijacin de cables y ductos a la escalerilla debe realizarse con abrazaderas
metlicas galvanizadas o de acero inoxidables. Est prohibido el uso de
amarras plsticas, ya que se vuelven quebradizas ante la exposicin prolongada a
la luz solar.
Los cables de fibra ptica y de alimentacin DC instalados en los feeder clamp en la
estructura vertical deben seguir la distribucin indicada en la figura siguiente. Los
feeder clamps slo deben ser utilizados en la torre, luego del conduit y corta gota (3
metros sobre el nivel de piso). En caso que la torre sea del tipo mono poste o
ventada no utilizar clamps en la parte superior de la torre (Plataforma, usar
amarra metlica).

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page27

RUTEO DE CABLES OPTICOS Y ELEC


TRICOS

NOTA: Para sitios colocalizados en infraestructura de CLARO, la subida de cables


DC y FO por una torre auto-soportada debe realizarse por las cantoneras. Est
prohibido utilizar la escalerilla de subida o perfiles que estn definidos como de
exclusividad de Claro.

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page28

RUTEO DE CABLES OPTICOS Y ELEC


TRICOS

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page29

Connection Practice

Connection
Practice

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page30

Power On a Base Station

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page31

Contents

2 Installation Referenced Technical p


oint

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page32

Technical point - Assemble the


antenna

Assemble the
support
Install the upper
support on the
antenna.
Install the lower
support on the
antenna.

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Technical point - Assemble the


antenna
Adjust the down-tilt of the antenna by referring to the scales on

the upper support or by using the inclinometer.

Antennas should be in the 45-degree protected area of lightning


rod.

Adjust the tilt of the inclinometer according to the requirement in


the engineering design

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Antenna M-Tilt and E-Tilt Adjustm


entAdjust the E-Tilt

Note:
Adjust the E-Tilt for each sector according to the planning.
Take the Photo for each sector after adjustment.

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page 35

Technical pointinstall the


antenna
on the tower
There need lifting rope and traction rope, to prevent the feeder hitting

from tower

Feeder connector should be wrapped to protect it

Do not tightly
secure the
screws on the
upper and
lower ,
convenient
azimuth
adjustment of
the antenna.
And also avoid
the antenna
drop from the
pole.
Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Antenna Mechanical Down Tilt Adjustment


Adjust the M-Tilt
Note:
Adjust the M-Tilt
for each Antenna
according to the
planning.
Take the Photo for
each Antenna after
adjustment.

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page 37

Technical point - Lift the RRU and


the holding pole
1

When lifting the RRU to the tower, avoid collision of the RRU
with the tower

When lift the RRU, bind the whole RRU but not only the handle

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

of the RRU

Technical point - Lift the Fibers


Lifting
rope

Pulley

Tensile
rope

Steering
rope
Lifting
rope

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page39

Steering
rope

Technical point - Lift the Power


Cables
Pulley

Lifting
rope
Steering
rope

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page40

Attentions for the cabinet installatio


n

When cabinets installed


side by side, the space
should be within 3 mm
offset between the two
cabinets, and within 5
mm offset parallel in
front.

The base and the


cabinet must be screwed
each other tightly, and
the steady.

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Technical point --Lay and bind t


he Cables

Lay and bind the Cables

Use the cable tie with white color indoor


and black color outdoor.

The distant between two cable tie is


between 20cm to 40cm (less than 25cm

[p:pn
in perpendicular direction), and the
tie
should be in the same direction. dkjl]

Smoothly cut the redundancy of the


cable tie

Power cable:

[rdndnsi:]

The space between a power cable/ground


cable and a signaling cable outside the
good
cabinet should be more
than 3 cm
Without
appearan
fixed
straight
cross
ce

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Technical point Make Waterproof Con


nector
Step1
Connect
jumpers
to RRU,
tighten
the
connecto
rs;
wrapped
spirally
insulatio
n tape in
one
layers

Step2
The
waterproof
tape is
wrapped
spirally
upwards,
downwards
, and then
upwards
again in
three
layers

Step3

Step4

The
insulatio
n tape is
wrapped
spirally
upwards,
downwar
ds, and
then
upwards
again in
three
layers

Tightly
Seal the
two ends
of the
waterproo
f
connector
when
finish
wrapping

NOTE: For every two insulation tape layers, the tape on the upper
layer overlaps about half the width of the tape on the lower layer

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Technical point Waterproof Bend

When make a waterproof bend, the radius of the curve


should be more 20 times than the diameter of the jumper .

The jumper should be wrap tightly on the pole with the


ties.

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Technical pointColor Ring cable

Both side of the cable need to have the cable, If the

customer no specified label, according to our standard.


Example for the color ring
The colors of from sector0 to sector5

Sector Fiber
1
2
3

Power
Cable

Jumper
Main

Diversity

Red
One ring Two ring One ring
color
Yellow
One ring Two ring One ring
color
Blue
One ring Two ring One ring
color

The main ANT connect to ANT port A with two


ring
The diversity ANT connect to ANT port B with
one ring

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Technical point - Color Ring cable

Make the feeder or jumper color rings for 3


sectors
Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Technical point - Color Ring cable

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Power, CPRI Ground and Jumper Labels

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Power, CPRI Ground and Jumper Labels

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Power, CPRI Ground and Jumper Labels

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.

Power, CPRI Ground and Jumper Labels

1
me
tro

Sali
da
1
1
me me
tro SHEL
tro
TER

RA
CK
19

1
m
etr
o

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page51

1 MI
m NIetr SH
o ELT
ER

Leftover FO Cables

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page52

Escalerilla gabinete-ESA. Proteccin de


cables.

El ingreso de conduits o cualquier orificio debe quedar sellado con sikaflex 11,
descartar la espuma. Los conduit que ingresan al gabinete deben incluir un terminal
de conduit metalico.

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page53

Escalerilla gabinete-ESA. Proteccin de


cables.

Los cables DC y FO deben protegerse mediante conduit corrugado desde la


salida del Gabiente , gabinete de energa o Shelter existente hasta una altura de
3 mts sobre el nivel de la escalerilla en la llegada a la ESA. Debe instalarse 2
canalizaciones conduit de 2 cada una, una para FO y otra para energa DC.
La fijacin de los conduit debe ser con abrazadera metlica galvanizada o de
acero inoxidable, se permitir la utilizacin de amarra plstica solo en el caso
que la escalerilla sea con tapa y este quede correctamente instalada.
Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.
Page54

Escalerilla gabinete-ESA. Proteccin de


cables.

Copyright 2014 Huawei Technologies Co., Ltd. All rights reserved.


Page55

Thank you
www.huawei.com

You might also like