RRKPL Pumping In case FR bypassed to RKPL is greater than 440 cu. m/hr., BTPL Pumps will act as a bottleneck. In case FR bypassed to RKPL is around 400-440 cu. m/hr., BTPL Pumps will aid in reducing RMDS discharge pressure by 10-15 kg/sq. cm. In such case, FR ex RMDS can reach up to 800 cu. m/hr. (approx. gain of 50 cu. m/hr.).
Case-2: BTPL Pumps are used for
pumping in RKPL ex BRS RMDS to BRS can achieve the maximum FR of 800 cu. m/hr.
FR ex BRS to RKPL can be 400-440 cu. m/hr.
Minimum 3 tanks will be blocked (one each for RBPL,
one for RKPL and the third for Bahadurgarh terminal).
Additional Information Required
Pump Performance Curves are provided for 2400 rpm. Pump Performance Curves for 3000 rpm are required. Differential Pressure is assumed as Total Discharge Pressure (as Maximum Discharge Pressure is not mentioned in the Data Sheet). Mechanical Seal is designed for a pressure of 51 kg/sq. cm. Hence, this does not pose any constraint. The above additional information will help in exploring scope for further flow enhancement.