INTRODUCTION

WHAT IS STAAD :STRUCTURE ANALYSIS


AND DESIGN

ABOUT STAAD
PRO.V8i

DESIGN SUPPORTS OVER 70


INTERNATIONAL CODES
AND
2O U.S CODE IN SEVEN
LANGUAGE

STAAD PRO.
VERSIONS
OLDER VERSION
STAAD III
CALLED
FOR WINDOW AND USED BY LOWA STATE
UNIVERSITY FOR EDUCATIONAL PURPOSE
FOR CIVIL ENGG & STRUCTURE ENGG

COMMERCIAL VERSION OF STAAD PRO. V8i


IT SUPPORTS SEVERAL STEEL & CONCRETE,
TIMBER DESIGN CODE

ABOUT STAAD.pro v8i


THE i IN THE NEW VERSION V8i
STANDS FOR :INTERACTIVE,INCREDIBLE, INTRINSIC,
INTEROPERABLE .
BENTLEY CALLS V8i THE MOST
COMPREHENSIVE AND SIGNIFICANT
RELEASE IN THE HISTORY .

BASIC STEP FOR ANALYSIS &


DESIGN
1.
2.
3.
4.
5.
6.
7.
8.
9.

MODEL GENERATION
SECTION PROPERTIES
MATERIAL PROPERTIES
MEMBER SPECIFICATION
SUPPORTS
LOADS
ANALYSIS
POST PROCESSING
DESIGN

STAAD.pro SCREEN
ORGANISATION
SCREEN HAS FIVE MAJOR ELEMENT:1.
2.
3.
4.
5.

MENU BAR
TOOL BAR
PAGE CONTROL
MAIN WINDOW
DATA AREA

MANUAL CALCULATION
FOR BEAM
ASSUME A TRIAL CROSS SECTION
We have simple beam supported on two
wall. 230 mm thick 5m apart.Live Load 10
kn/m . Take fe = 415, fck =25 concrete
b = 230 mm
D = span /10
i.e= 5000/10 = 500mm
Self weight =25x.23x.5 = 2.875 kn/m

FACTORED LOAD
1.5(DL+LL)
1.5(2.875+5+10) =26.8125 kn/m =Wu
FACTORED MOMENT
Mu = 83.789
For fe 415 Mu lim = 0.1389fck bd^2
R lim = Mu lim / bd^2
R lim= 3.4725 mpa
d = sqrt(Mu/R lim b)
323.98= 325mm

Assume dia of primary bar = 20mm


dia of secondary bar = 8mm
Clear cover =30mm
D = 325+30 +8+20/2=373= 375mm
Based on new D value,d = 327
.

AREA OF STEEL
R=Mu/bd^2
83.789x10^6/(230x327^2) = 3.4069 Mpa
Pt/100 =Ast/bd
Ast/bd =fck/2fy*(1-sqrt(1-(4.598xR)/fck))
=1.71x10-2
Ast = 1.71x10^-2x230x327 = 881mm^2

Design Performed by Staad


pro.
Column
Group

CG1

Columns

Floor-Level

Column
size
(mm)

Axial Load
(kN)

Mx
(kN-m)

My
(kN-m)

Concrete
Grade

Main Steel
Grade

Stirrup
Steel
Grade

Main Steel
(mm)

Stirrup
Steel
(mm)

Ast Req
(mm)

Ast Prov
(mm)

Ast Perct

Load
Combinatio
n

C1

Column Detail
Floor1Report:
SPACEFRAME STRUCTURE
300 x
As Per IS 456 : 2000

M20

#8 @
Fe500 Fe415 #16 - 6
135
250

M20

#8 @
Fe500 Fe415 #16 - 6
135
250

Floor3
300 x
99.45 51.76 17.86 M20
Default 450
Level

#8 @
Fe500 Fe415 #16 - 6
793
250

Default 450
Level

242.04 0.91

0.66

Floor2
300 x
212.86 15.39 6.82
Default 450
Level

1206

1.50
DL +
0.894
1.50
LL

1206

1.50
DL +
0.894
1.50
LL

1206

1.50
DL +
0.894
1.50
LL

Design of Foundation
As the Code 456 for Concrete Says

MANUAL CHECK FOR


FOUNDATION
These Part of Building is much Harder part of
Building
We Normally analyses the By Taking:Horizontal Moment
Vertical Moment
From portal method we can easily analyse
these type of footing

Another Reqd Data for


Check

Mu lim > Mu
Ast > Ast Reqd
Check for Shear & pt of Steel

Performed Design By Staad Pro.