Debugging Explanation
Debugging the OMP Board
Debugging Explanation
Debugging Explanation
Debugging the OMP Board
Prerequisite
Boot parameters and examples
Parameter Example
MAC address of the OMP 00.208.208.161.00.X(X stands for the office ID)
Office ID 1
Debugging the OMP Board
1. Click Start > Programs > Accessories > Communications
> HyperTerminal.
2. Input new connection name and then click OK button.
Debugging the OMP Board
3. Select serial port and then click OK button.
Debugging the OMP Board
4. Click on Restore Defaults button and then click OK button.
Debugging the OMP Board
5. Press any key from keyboard to stop auto-boot when the
HyperTerminal window appears.
Debugging the OMP Board
6. Enter password 3gplat to login.
Debugging the OMP Board
7. Enter 1 for configuring MP parameters.
Debugging the OMP Board
8. Enter 1 for configuring OMP IP address, Mac address.
Debugging the OMP Board
9. Enter 2 to configure OMC IP address, and login to FTP server
to get version files from OMC server.
Debugging the OMP Board
10. Enter OMP boot file name: ompcfgX.ini (X stands for ID of
the managed element where OMP is located).
Debugging the OMP Board
11. Enter 3 to select OMP boot type and then enter 0 to boot
OMP from OMC.
Debugging the OMP Board
12. Enter 4 and then enter 1 to set bureau number similar to
office ID.
Debugging the OMP Board
13. Enter 5 and then enter 0 to start auto-boot.