You are on page 1of 96

Section 6

Creating a BSS Configuration

NORTEL NETWORKS CONFIDENTIAL


Objectives

Upon completion of this section, you will be able to configure a


BSS and to define the main parameters of the objects.

You will be able to describe:


The object hierarchy for creation (deletion) and initialization
process
Inter-object relationship and the consequences on the
creation (deletion) or initialization process
Objects dictionary describing all the BSS equipment
The Managed Logical Objects

NORTEL NETWORKS CONFIDENTIAL 2


Contents
Object Hierarchy transcoderSoftware Object (Tcue3) GSM/Umts cell (re)selection
Order of Creation Tcu2G/Tcue3 supported by the Bsce3 3G cell searching parameters at OMC-R
Objects automatically created pcmCircuit Object (A interface) Radio Measurements
bscMdInterface Object Transcoder Matrix Paging
OMC-R Communication Equipment SignallingLink Object Handover
BSC Object xtp Object Call Queuing
Logical view of a Bsce3 equipment pcmCircuit Object (Agprs interface) Congestion - Directed Retry
Control Node: Permanent Data LapdLink Object Frequency Hopping
Interface & Transcoding Node Perm. Data PCU Object Power Control
Control Node: Dynamic Data Pcusn Object RadioLink Supervision
Interface & Transcoding Node D.D. pcmCircuit Object (Abis interface) Timers
Actions from a BSC object lapdLink Object (BCF - OML) adjacentCellReselection Object
BSC Board Provisioning lapdLink (Abis) Object (concentration powerControl Object
executableSoftware Object for Bsc2G) handoverControl Object
software-bsc lapdLink Object adjacentCellHandover Object
signallingLinkset & btsSiteManager Object frequencyHoppingSystem Object
signallingPoint Objects ConfigRef lapdLink Object
pcmCircuit Object (Ater interface) (TRX/DRX - OML and RSL)
software-btsSiteManager
lsaPcmList parameter (for Bsce3&Tcue3) transceiverEquipment Object
MultipleSite Object
software-transceiverEquipment
lapdLink Object (TCU) Bts Object
transceiver Object
Transcoder Object (Tcu2G) Cell Identity channel Object
transcoderBoard Object Technical Features transceiverZone Object
Software-transcoderBoard Cell Selection Access
Transcoder Object (Tcue3) Cell Reselection

NORTEL NETWORKS CONFIDENTIAL 3


Object Hierarchy (1)
Order of Object Creation/Deletion
bscMdInterface executable software

Bsc
BSC Hardware
configuration
automatically triggered bsc software

pcmCircuit (Agprs) pcmCircuit (Ater) signallingPoint


lapdLink lapdLink signallingLinkSet
DELETION
Pcu Transcoder
CREATION Pcusn transcoderBoard Transcoder
(only for Bsc2G) Software

TCU Hardware
transcoderBoard configuration
Software (only for Tcu2G) automatically triggered

pcmCircuit A

signallingLink Xtp
and in green character: ADD for a BSS with Bsce3 and Tcue3

NORTEL NETWORKS CONFIDENTIAL 4


Object Hierarchy (2)
Order of Object Creation/Deletion
Bsc (already created)

pcmCircuit (Abis)

lapdLink

btsSiteManager

btsSiteManager
CREATION Software DELETION

Bts

lapdLink
Transceiver
transceiverEquipment

transceiverEquipment Channel
Software
NORTEL NETWORKS CONFIDENTIAL 5
Order of Creation
for each BSC

bscMdInterface
Bsc for each site
softwarebsc pcmCircuit Abis
signallingPoint
signallingLinkSet
1 lapdLink (OML for the BCF)
btsSiteManager
pcmCircuit Ater
softwarebtsSiteManager
lapdLink (OML for the TCU) for each cell
multiple site
Transcoder (+ trans. software ) Bts
transcoderBoard (only for Tcu2G) handOverControl
2 powerControl
softwareTCB (only for Tcu2G)
pcmCircuit A adjacentCellHandOver
signallingLink
adjacentCellReselection
Xtp 3 frequencyHoppingSystem
pcmCircuit Agprs
Pcu
for each TRX/DRX
Pcusn
lapdLink (OML and RSL)
transceiverEquipment
4
softwaretransceiverEquipment
Transceiver

and in green character: ADD for a BSS with Bsce3 and Tcue3
Channel
transceiverZone for concentric cells
NORTEL NETWORKS CONFIDENTIAL 6
Objects automatically created (for
Bsce3 & Tcue3)
1- In case of a Bsce3 2- In case of a Tcue3
bsc Automatically
triggered transcoder

pcmCircuit software transcoder3gEqpt


bsc3Geqpt

modules
Lsa cem trm
cn in

iem

mms omu tmu atmSw 8krm atm cem Lsa

boards
mms iem

NORTEL NETWORKS CONFIDENTIAL 7


bscMdInterface Object
bscMdInterface [0..255]
Network protocol used [X25 network, IP network]
bscIPFirstAdr [IP Add]
bscIPSecondAdr [IP Add]
bscX.25PrefAdr [X.25 Add]
bscX.25SecAdr [X.25 Add]
portChosen [port0, port1, automatic choice]
bscUsedAdr [communication not established, X.25, IP]

bscUsedAdr [communication not established, X.25, IP]


portUsed [port0, port1]
Legend
availabilityStatus [{}, dependency, failed] Blue: Permanent Data

operationalState [enabled, disabled] Brown: Internal Data

Green: Dynamic Data


Create, Clone, Set, Set administrativeState, Delete, Display, Display all
Display port information, Display IP information, Display circular file state, Red: MAIN Actions
Close circular file, Open circular file, Clear circular file
Green data: for Bsce3

NORTEL NETWORKS CONFIDENTIAL 8


OMC-R Communication Equipment
(Direct Access)
OMC-R

BSC 2G Station

Chain A
0
SICX
SLS board X.25 (or IP)
board
Link 1 1
X.25 64 Station
kbits
or
Chain B 19.2 2
kbits IP
Netw.
SICX
SLS board X.25 (or IP) 3
board
Link 2 HSI Station

green character: BSS with Bsce3

NORTEL NETWORKS CONFIDENTIAL 9


OMC-R Communication Equipment (via MSC)
ONLY with a Bsc2G
OMC-R

Station
TS2
TS2
0
0
TCU 1
2
0 3 1
Station
0 pcm 64
TCU 1 X.25 kbits
2
BSC 2 MSC
1 3 pcm Switch

DPN 100
0 3
TCU 1
2 HSI Station
2 3

Ater A

NORTEL NETWORKS CONFIDENTIAL 10


BSC Object (1)

bsc [1..255]
bscAlarmMask [3] [xxxxxxxx] (x = [0,1]) encryptionAlgorSupported [1] [none, gsmEncryptionV1 (A5/1)
bscArchitecture [0] [bsc6000, bsc12000, bsc30000] gsmEncryptionV2 (A5/2)]
bscCapacityReduction V14 [Int 0..9] HOSecondBestCellConfiguration [3] V9 [1..3]
bscGprsActivation [3] V12 [disabled, enabled] hoTraffic [3] V12 [disabled, enabled]
bscHopReconfUse [1] V8 [false, true] intraBscDirectedRetry [3] V9 [allowed, not allowed]
bscMdInterfaceRef [0..255] interBscDirectedRetry [3] V9 [allowed, not allowed]
bscMSAccessClassBarringFunction [3] V9 [mobileCountryCode] [1] [0..999]
[disabled, enabled] [mobileNetworkCode] [1] [0..999]
bscName (30 char max) modeModifyMandatory [3] V9 [used, not used]
bscType [0] [type1, type2, type3, type4, type5]
Er
multipleVocoders [1] V8 [false, true]
bssMapTchoke [1] [1..255] processorLoadSupConf [3] V8 [0..9 (V10, V11)
bssMapT1 [1] [2..300] 0 (V12)]
bssMapT4 [1] [5..600] radResSupBusytimer [3] V8 [1..18]
bssMapT7 [1] [2..120] radResSupervision [3] V8 [true, false]
bssMapT8 [1] [0..255] radResSupFreetimer [3] V8 [1..18]
bssMapT12 [1] [2..300] timeBetweenHOConfiguration [3] V9 [used, not used]
bssMapT13 [1] [2..300] uplinkMappingProcessingMode [3] V12 [disabled,enabled]
bssMapT19 [1] V8 [2..300] xSCBConfiguration [0] V8 [2..14]
bssMapT20 [1] V8 [2..300]

NORTEL NETWORKS CONFIDENTIAL 11


BSC Object (2)
activeChain [chainA,chainB] {active,passive} chain REM link state [Working, Degraded,
{active,passive} chain Dmux state Partially degraded, Not significant]
EQPD{0,1} converter [all working, one failed] {active,passive} chain Sic Board state [states of SICX, SICD
MPU fans [all working, one failed] and CCS7] [working, fault]
MPU converters [all working, one failed] {active,passive} chain sic channels state [working, fault]
RCB{0,1,2,3,4} [absent, present] {active,passive} chain sls board state [working, fault]
MPU fan power supply [all working, one failed] {active,passive} chain switching capacity [working, fault]
Control bay extractor [all working, one failed] {active,passive} chain tcu accessibility [working, fault]
Control bay extractor power supply [all working, one failed] {active,passive} chain ute board state [working, fault]
MPU converter other channel [all working, one failed] active rem link [rem link 0, rem link 1]
Right MPU converter [all working, one failed] aLAIntState [working, fault]
EQPD low rack converter [all working, one failed] availabilityStatus [{}, degraded, in test, dependency, failed,
SWD converter [all working, one failed] not installed]
EQPM converter [all working, one failed] bdaVersionNumber [0..254]
EQPT converter [all working, one failed] bscDateTime [dd/mm/yy hh:mm]
EQPD converter [all working, one failed] bscMdInterfaceVersionNumber [0..65535]
EQPI converter [all working, one failed] duplex link state [working, fault]
EQPD high rack converter [all working, one failed] operationalState [enabled, disabled]
EQPM EQPD fan [all working, one failed] synchronizing PCM [synchro mic 0, synchro mic 2, synchro mic
EQP fans [all working, one failed] 4, synchro mic 6, synchro internal clock]
{active,passive} chain state [nominal state, deteriorated xSCBNumber [0, 1]
state] xSCBUse [xSCB board state + list of concentrated lapd links ]
{active,passive} chain disk state [Working, Degraded, lcsType V14 [nss-based/bss-based]
Partially degraded, Not significant]
{active,passive} chain ECI board state [working, fault]

Create, Set, Set administrativeState, Set class 1 parameters, Delete, Display, Display all, Display D.D,
Audit BDA,Off line reset BDA, On line reset BDA, Build BDA, Synchronize bsc clock,
Suicide chain, Kill chain, display chain information, Bsc request, Bsc Reset, Load balancing required

NORTEL NETWORKS CONFIDENTIAL 12


BSC Object (3)

BSC Internal Data

auditState [inProgress, notInProgress]


bdaNewBscState V11[ready for on-line reset, running on-line reset, waiting for on-line
build, waiting for software change, waiting for Bda change, running software change,
running Bda change, waiting for end of probative phase]
bdaSelected V11 [running, new]
bdaState [built, not built, inconsistency]
buildState [inProgress, notInProgress]
enhancedTRAUFrameIndication V12 [notAvailable, available, active]
geographical coordinates V11
Deg Lat [0..90] deg
Min Lat [0..59] min
Hundredth of sec Lat [0..5999] th sec
Direction Lat [North, South]
Deg Lon [0..180] deg
Min Lon [0..59] min
Hundredth of sec Lon [0..5999] th sec
Direction Lon [East, West]

NORTEL NETWORKS CONFIDENTIAL 13


Logical view of a Bsce3 equipment

NORTEL NETWORKS CONFIDENTIAL 14


Control Node: Permanent Data

AdministrativeState [locked, unlocked, shutting down]


Position In Shelf [1 to 15]
Shelf Number [0 to 1]

Control Node
cnId [0 to 0]

OMU boards:
omuId [0 to 2147483646]

MMS boards
PrivateMmsOmuRef [0 to 2147483646]
mmsId [0 to 2147483646]
mmsUsage [Shared (0)/Private (1)]

TMU boards
tmuId [0 to 2147483646]

CCs boards
ccId [0 to 2147483646]

* = common to every board

NORTEL NETWORKS CONFIDENTIAL 15


Interface & Transcoding Nodes Perm. Data

AdministrativeState [locked, unlocked, shutting down]


Position In Shelf [1 to 15]
Shelf Number [0 to 1]

Interface Node Transcoding Node


inId [0 to 0] LapdLinkCallPLoad [0 to
65535]
Position In Shelf [1 to 15]
TRM boards
CEM boards trmId [0 to 2147483646]
CemId [0 to 2147483646]

LSA-RC boards
LsaRcId [0 to 2147483646]
Lsa Pcm List [0 to 167]
IEM boards
iemId [0 to 2147483646]
lsaRc Reference [0 to 2147483646]
Lsa Pcm List [0 to 167]

ATM-RM boards
AtmRmId [0 to 2147483646] * = common to every board
sw8k-RM boards
sw8kRmId [0 to 2147483646]

NORTEL NETWORKS CONFIDENTIAL 16


Control Node: Dynamic Data

OperationalState [enabled, disabled]


AvailabilityStatus [{}, degraded, in test, dependency, failed, not installed]
UpgradeStatus [{}, in progress, performed]

Control Node
OperationalState [enabled, disabled]
AvailabilityStatus [{}, degraded, in test, dependency, failed, not installed]
InterOmuEtherLinkOper [disabled/enabled]
Site, Unit, Floor, row position

OMU boards:
StandbyStatus [providing service, Hot Standby]
Port Ethernet Operational [enabled, disabled]
Port Ethernet Status [{}, dependency, failed]
Port 0 X25 Status [0 to 8]
Port 1 X25 Status [{}, dependency, failed]
X25Port 0,1 Operational [enabled, disabled]

TMU boards
numberOfEnabledHDLCPorts [0 to 65535]

* = common to every board

NORTEL NETWORKS CONFIDENTIAL 17


Interface & Transcoding Nodes Dynamic Data

Interface Node
OperationalState [enabled, disabled]
AvailabilityStatus [{}, degraded, in test,
dependency, failed, not installed] LSA-RC boards (I Node + T Node)
StandbyStatus [providing service, Hot
CEM boards (I Node + T Node) Standby]
OperationalState [enabled, disabled] OperationalState [enabled, disabled]
StandbyStatus [providing service, AvailabilityStatus
Hot Standby] Lapd Exists [True / False]
AvailabilityStatus
UpgradeStatus [{}, in progress, performed] IEM boards (I Node + T Node)
StandbyStatus [providing service, Hot
Standby]
ATM-RM boards OperationalState [enabled, disabled]
StandbyStatus [providing service, AvailabilityStatus
Hot Standby] UpgradeStatus [{}, in progress, performed]
OperationalState [enabled, disabled] CTU cable [true / false]
UpgradeStatus [{}, in progress, performed] numberOfEnabledHDLCPorts [0 to 65535]
AvailabilityStatus Lapd Exists [True / False]

sw8k-RM boards Transcoding Node


StandbyStatus [providing service, TRM boards
Hot Standby] OperationalState [enabled, disabled]
OperationalState [enabled, disabled] AvailabilityStatus
AvailabilityStatus UpgradeStatus [{}, in progress, performed]
UpgradeStatus [{}, in progress, performed]

NORTEL NETWORKS CONFIDENTIAL 18


Actions from a bsc object

Actions from
Pop-Up menu

NORTEL NETWORKS CONFIDENTIAL 19


BSC Board Provisioning (1)
Architecture BSC 12000 BSC 12000HC
Type 1 2 3 4 5 1 2 3 4 5
Control cabinet (multiply board numbers by 2 for the 2 chains)
CCS7 1 2 2 2 3 1 2 2 2 3
CPUM 1 1 1 1 1 1 1 1 1 1
CPUE 2 2 3 3 3 2 2 3 3 3
MMU 1 1 1 1 1 1 1 1 1 1
SICD8 1 2 3 4 5 1 2 3 4 5
SICX 1 1 1 1 1 1 1 1 1 1
SLS 1 1 1 1 1
SLS 2 1 1 1 1 1
SUP / SUP2 1 1 1 1 1 1 1 1 1 1
Equipment cabinet (multiply board numbers by 2 for the 2 chains)
ECI 1 1 1 1 1 1 1 1 1 1
MSW 2 2 2 2 2 2 2 2 2 2
RCB 1 2 3 4 5 1 2 3 4 5
SWC 1 1 1 1 1 1 1 1 1 1
SWE 2 2 2 2 2 2 2 2 2 2
Equipment cabinet (boards shared by the 2 chains)
ALA 1 1 1 1 1 1 1 1 1 1
TSCB 2 2 2 2 2 2 2 2 2 2
BSCB 0-12 0-12 0-12 0-12 0-12 0-12 0-12 0-12 0-12 0-12
DDTI (E1/T1) 24 24 24 24 24 24 24 24 24 24

NORTEL NETWORKS CONFIDENTIAL 20


BSC Board Provisioning (2)

The BSC type depends on the number of SICD Boards.

The XSCBConfiguration parameter indicates


the sum of TSCB boards and BSCB boards

XSCBConfiguration TSCB BSCB


2 2 0
4 2 2
6 2 4
8 2 6
10 2 8
12 2 10
14 2 12

NORTEL NETWORKS CONFIDENTIAL 21


executableSoftware Object (new from V14)

executableSoftware [0 to 255]

executableSoftwareId [0 to 255]
executableSoftwareName
softwareLabel
relatedSoftwares
ConfigRefList [0 to 150]
bscList [0 to 41]

NORTEL NETWORKS CONFIDENTIAL 22


software-bsc
Parameters involved

software [0..231-2]
sWVersionBackup [NNNabxynn]
sWVersionFallback [NNNabxynn]
sWVersionNew [NNNabxynn]
sWVersionRunning [NNNabxynn]

Create, Display, Delete


Activate new version, Return to previous version
Download, Display markers

NORTEL NETWORKS CONFIDENTIAL 23


signallingLinkset & signallingPoint Objects
Parameters involved signallingPoint [0..231-2]
bscCapacityReduction V14 [Int 0..9]
bscQueueingOption [1] [not allowed,
signallinglinkSet [0..231-2] allowed (MSC driven),
errorCorrectionMethod [1] [basicRetr, prevCyclRetr] forced (O&M driven)]
bssSccpConnEst [1] [5..360 by step 5]
pointCode [1] [0..16383] bssSccpInactRx [1] [2..30]
networkIndicator [1] [nationalUse] bssSccpInactTx [1] [1..15]
bssSccpRelease [1] [1..20]
bssSccpSubSysTest [1] [5..60 by step 5]
sCCPRoutingIndicator V14 [international, national]
ccs7RemoteSubSystemNumber V14 [0.inf]
accessibilityState [reachable, congested, unRacheable] ccs7LocalSubSystemNumber V14[0.inf]
remoteSsuState [in service, outOfService] chosenChannelAssComp [1] [True, False]
chosenChannelCompL3Info [1] V8 [True, False]
chosenChannelHoPerf [1] V8 [True, False]
chosenChannelHoReq [1] V8 [True, False]
circuitGroupBlock [1] V8 [False]
Create, Set, Set class 1 parameters confusion [1] V8 [False]
cypherModeReject [1] V8 [True, False]
Delete, Display, Display all encrypAlgoAsscomp [1] V8 [True, False]
encrypAlgoCiphModComp [1] V8 [True, False]
encrypAlgoHoPerf [1] V8 [True, False]
encrypAlgoHoReq [1] V8 [True, False]
layer3MsgCyphModcomp [1] V8 (True, False]
networkIndicator [1] [nationalUse]
pointCode [1] [0..16383]
resetCircuitRepeat [1] V8 [False]
signallingPointType [noSTP]
speechMode [3] V8 [full rate, enhanced full rate]
Phase II Parameters speechVersionAsscomp [1] V12 [True, False]
speechVersionHoperf [1] V12 [True, False]
speechVersionHoreq [1] V12 [True, False]
speechVersionHorqd [1] V12 [True, False]
Create, Delete, Display Set, Set class 1 parameters unequippedCircuit [1] V8 [False]

NORTEL NETWORKS CONFIDENTIAL 24


pcmCircuit Object (Ater interface)
Parameters involved

pcmCircuit [0..47 /167 (for Bsce3)]


cRC [2] [used, not used]
pcmType [3] [pcmA, pcmAbis, pcmAter, pcmAgprs]

Create, Set, Set administrativeState, Delete, Display, Display all

Agprs interface
PCU pcmType = pcmAgprs
Site 1
A interface Ater interface

Trans- Abis interface


MSC coder
BSC
pcmType = pcmA pcmType = pcmAter
Site 2
pcmType = pcmAbis
NORTEL NETWORKS CONFIDENTIAL 25
lsaPcmList parameter (for Bsce3 & Tcue3)
pcmCircuit # 0

TCU e3 BSC e3
CTU CTU
LSA-RC #0 LSA-RC #0

CTU IEM IEM CTU


#1
IEM IEM
CTU CTU
#0

CTM 7
CTU #X, port 0 pcmCircuit # 0
CTM 7
CTU # Y, port 20

CTM 1
CTM 1

NORTEL NETWORKS CONFIDENTIAL 26


lapdLink Object (TCU)
Parameters involved
1 per Tcu2G
2 per Lsa-Rc
lapdLink [0.. 231-2]
associatedInterface V8 [aBis, aTer,Agprs]
lapdConcentration [enabled, disabled]
lapdTerminalNumber [0] [0..39]
sapi [RSL, OML]
teiLapdLink [0..127]

availabilityStatus [{}, dependency, failed]


operationalState [enabled, disabled]
pcmCircuitId [0..47]
timeSlotNumber [1..31] (E1) or [1..24] (T1) Create, Set, Delete, Display, Display all

Lapd Frame

Start Flag Address Control Information FCS Flag

NORTEL NETWORKS CONFIDENTIAL 27


lapdLink Object (TCU 2G)

TCU 0
SICD8
TCU 1

TCU 2
SICD Port LapdTerminalNumber

TCU 3
TSCB
BSC
12000

TCU 10

TCU 11

NORTEL NETWORKS CONFIDENTIAL 28


Transcoder Object (Tcu2G)
transcoder [0..13]
lapdLinkOMLRef [0] [0.. infinite] transcoderMatrix
pcmCircuitId [2] [0..47] [TCU switching configuration Ater-TS <-> A-TS]
teiTranscoder [2] (0..127] geographical coordinates V11
transcoderAlarmMask [3] [xx] (x=[0, 1]) Deg Lat [0..90] deg
version [2] V8 [1, 2] Min Lat [0..59] min
Hundredth of sec Lat [0..5999] th sec
Direction Lat [North, South]
Deg Lon [0..180] deg
alarmListConverter [working, failed] Min Lon [0..59] min
alarmListFan [working, failed] Hundredth of sec Lon [0..5999] th sec
Direction Lon [East, West]
alarmListFanBoard [working, failed]
alarmListVCOTension [working, failed]
availabilityStatus [{}, dependency, failed]
operationalState [enabled, disabled]
transcoderIntPcmState [working, fault]

Create, Set, Set administrativeState, Delete, Display,


Display all

NORTEL NETWORKS CONFIDENTIAL 29


transcoderBoard Object

Parameters involved

transcoderBoard [0..9] GSM 900/1800


[0..7] GSM 1900
algorithmUsed [2] V8
[algoId [full rate, enhanced full rate],
powerUplink [-15, 15] dB,
powerDownLink [-15, 15] dB]
data mode 14.4 kbit/s [2] V11
[disabled, enabled]
hardwareRef [2] [0..65535]

availabilityStatus [{}, dependency, failed]


operationalState [enabled, disabled]
transcoderBoardIntState [working, fault]

Create, Set, Set administrativeState, Delete, Display, Display all

NORTEL NETWORKS CONFIDENTIAL 30


Software-transcoderBoard

Parameters involved

software [0..231-2]
sWVersionBackup [NNNabxynn]
sWVersionFallback [NNNabxynn]
sWVersionNew [NNNabxynn]
sWVersionRunning [NNNabxynn]

Create, Display, Delete


Activate new version, Return to previous version
Download, Display markers

NORTEL NETWORKS CONFIDENTIAL 31


Transcoder Object (Tcue3)
OperationalState [enabled, disabled] transcoder [0..13]
AvailabilityStatus [{}, degraded, in test, dependency, transcoderArchitecture [tcu2G, tcu3G]
failed, not installed] transcoder3GEqptId V14 [0 to 0]
lapdLinkResources V14 [pcmRef [0 to 167]; lapdLinkCallPLoad [0 to 65535]
ts [1 to 31]; sapiType [RS /OML]; AdministrativeState [locked, unlocked, shutting down]
shelfNumber [0 to 1] coderPoolConfig:
positionInShelf [1 to 15] ] coderAlgo [fullRateCoder, enhancedFullRateCoder,
phase1DataCoder]
minimumCall
powerULI
powerDLI

Create, Display, Delete


Activate new version, Return to previous version
Download, Display markers

NORTEL NETWORKS CONFIDENTIAL 32


transcoderSoftware Object (Tcue3)

software
sWVersionBackup [NNNabxynn]
sWVersionFallback [NNNabxynn]
sWVersionNew [NNNabxynn]
sWVersionRunning [NNNabxynn]

Create, Display, Delete


Activate new version, Return to previous version TCUe3 (TC3 ref)
Download, Display markers Software version value example

TC314001709

NORTEL NETWORKS CONFIDENTIAL 33


Tcu2G/Tcue3 supported by the Bsce3

Bsce3 Case

NORTEL NETWORKS CONFIDENTIAL 34


pcmCircuit Object (A interface)
availabilityStatus [{}, dependency, failed]
dDTIntState [working, fault]
operationalState [enabled, disabled]
Parameters involved

pcmCircuit [0..47 /167 (for Tcue3)]


cRC [2] [used, not used]
pcmType [3] [pcmA, pcmAbis, pcmAter, pcmAgprs]

Create, Set, Set administrativeState, Delete, Display, Display all

Site 1

A interface Ater Abis


interface interface

MSC Transcoder BSC

pcmType = pcmA pcmType = pcmAter


Site 2

pcmType = pcmAbis
NORTEL NETWORKS CONFIDENTIAL 35
Transcoder Matrix (only for a TCU2G)

TSATER PCMA TSPCMA


TSATER PCMA TSPCMA
1 / / / / / LAPD
1 / / / / / LAPD 2 0 1 2 3 4 SS7
2 0 1 2 3 4 3 0 5 6 7 8
SS7 4 0 9 10 11 12
3 0 5 6 7 8 5 0 13 14 15 16
4 0 9 10 11 12 6 0 17 18 19 20
5 0 13 14 15 16 7 0 21 22 23 24 TS
8 0 25 26 27 28 switching TS
6 0 17 18 19 20 9 0 29 30 31 PCM
7 0 21 22 23 24 1 1 matrix PCMA
10 1 2 3 4 5 Ater
8 1 1 2 3 4
11 1 6 7 8 9
9 1 5 6 7 8 12 1 10 11 12 13
10 1 9 10 11 12 13 1 14 15 16 17
11 1 13 14 15 16 14 1 18 19 20 21
15 1 22 23 24 25
12 1 17 18 19 20 16 1 26 27 28 29
13 1 21 22 23 24 17 1 30 31
14 2 1 2 3 4 2 1 2
18 2 3 4 5 6
15 2 5 6 7 8 19 2 7 8 9 10
16 2 9 10 11 12 20 2 11 12 13 14
17 2 13 14 15 16 21 2 15 16 17 18
22 2 19 20 21 22
18 2 17 18 19 20 23 2 23 24 25 26
19 2 21 22 23 24 24 2 27 28 29 30
20 3 1 2 3 4 25 2 31
2 1 2 3
21 3 5 6 7 8 26 3 4 5 6 7
22 3 9 10 11 12 27 3 8 9 10 11
23 3 13 14 15 16 28 3 12 13 14 15
24 3 17 18 19 20 29 3 16 17 18 19
30 3 20 21 22 23
/ 3 21 22 23 24 31 3 24 25 26 27
unused / 3 28 29 30 31

T1 E1
NORTEL NETWORKS CONFIDENTIAL 36
SignallingLink Object
Parameters involved

signallingLink [0..5]
pcmCircuitId [2] [0..inf]
signallingTerminalNumber [2] [0..5]
slc [2] [0..15]
timeSlotNumber [2] [1..31] (E1 PCM)
or [1..24] (T1 PCM)
transcoderId [2] [0..11]

availabilityStatus [{}, dependency, failed]


operationalState [enabled, disabled]
signallingLinkResState [inhibited, inhibitedLocal, inhibitedDistant, inhibitedLocalDistant, blocked]
s1kAssociatedTmuPortPosition V14 [tmuPos / hardwareSlotPositionNMC / portNumber]
s1kATerResource V14 [pcmRef [0 to 167] ts [1 to 31] ]

Create, Set, Set administrativeState, Delete, Display, Display all, Set inhibit

NORTEL NETWORKS CONFIDENTIAL 37


xtp Object

Parameters involved

xtp [0..1439]
cic [32*PcmNumber on MSCside +TsNumber]
pcmCircuitId [2] [0..3]
timeSlotNumber [1..31]
transcoderId [2] [0..11]

availabilityStatus [{}, dependency, failed]


occupationState [preempted, notPreemted]
operationalState [enabled, disabled]
usageState [idle, busy]

Create, Set, Set administrativeState, Delete, Display, Display all

NORTEL NETWORKS CONFIDENTIAL 38


xtp Object (case with a Tcu2G)
xtp26 xtp0 SS7
mscPcm 0 31 5 4 3 2 1 0 pcm 0
SS7 lapd
1 1 pcm 1 2 1 0
TCU0 0
2 1 pcm 2

3 31 30 29 28 27 1 pcm 3
xtp115
xtp116 SS7
4 5 4 3 2 1 0 pcm 0
5 SS7 lapd
pcm 1 2 1
6 pcm 2 TCU1 2
7 27 pcm 3 6 TCUs
xtp231 with SS7 links

xtp580 SS7
20 5 4 3 2 1 0 SS7 lapd
21 2 1 BSC
TCU5
22
23 27
12005
MSC xtp695
xtp696
24 5 4 3 2 1 0 lapd
25 1
26 TCU6
27 27
xtp815
6 TCUs
without SS7 links
44 5 4 3 2 1 0 lapd
45 1
46 TCU11
47 27
xtp1415

NORTEL NETWORKS CONFIDENTIAL 39


pcmCircuit Object (Agprs interface)
Parameters involved

pcmCircuit [0..47 /167 (for Bsce3)]


cRC [2] [used, not used]
pcmType [3] [pcmA, pcmAbis, pcmAter, pcmAgprs]

Create, Set, Set administrativeState, Delete, Display, Display all

Agprs interface
PCU
pcmType = pcmAgprs
Site 1
A interface Ater interface

Trans- Abis interface


MSC coder
BSC
pcmType = pcmA pcmType = pcmAter
Site 2
pcmType = pcmAbis
NORTEL NETWORKS CONFIDENTIAL 40
LapdLink Object

lapdLink [0.. 231-2]


associatedInterface V8 [aBis, aTer,Agprs]
lapdConcentration [enabled, disabled]
lapdTerminalNumber [0] [0..39]
sapi [RSL, OML]
teiLapdLink [0..127] PCU

Agprs Interface

BSC

availabilityStatus [{}, dependency, failed]


operationalState [enabled, disabled]
pcmCircuitId [0..47]
timeSlotNumber [1..31] (E1) or [1..24] (T1) Create, Set, Delete, Display, Display all

NORTEL NETWORKS CONFIDENTIAL 41


PCU Object
Pcu [0..231-2]
bscPcuPcmRefList [2] V12 [1 to 12 values of pcmLink numbers] PCU
Dynamic AgprsAllowed V14 [enabled/disabled]
gprsPcuCrossConnectList [2] V12 PcmCircuit #
nbrTch [0..31]
pcmNbr [0..47]
pcuLapdEqtRefList [2] V12 [0 to 12 values of lapdlinknumbers]

GPRS TS

BSC

NORTEL NETWORKS CONFIDENTIAL 42


Pcusn Object
Pcuscn [0..255]
pcuSNNAme V12 (30 char max)
bscRefList [3] V12 [1 to12 values of bsc instances]
muxNumber [3] V12 [noMux, oneMux, twoMux]
flowControlMaxrate V12 [1001 to 9999] ms
flowControlMaxDelay V14 [5 to 6000] s

NORTEL NETWORKS CONFIDENTIAL 43


pcmCircuit Object (Abis interface)
Parameters involved

pcmCircuit [0..47/167 (for Bsce3)]


cRC [2] [used, not used]
pcmType [3] [pcmA, pcmAbis, pcmAter,pcmAgprs]

availabilityStatus [{}, dependency, failed]


dDTIntState [working, fault]
operationalState [enabled, disabled]

Create, Set, Set administrativeState, Delete, Display, Display all


Site 1

A interface Ater Abis


interface interface

MSC Transcoder BSC

pcmType = pcmA pcmType = pcmAter


Site 2

pcmType = pcmAbis
NORTEL NETWORKS CONFIDENTIAL 44
lapdLink Object (BCF - OML)
Parameters involved

lapdLink [0.. 231-2]


associatedInterface V8 [aBis, aTer,Agprs]
lapdConcentration [enabled, disabled]
lapdTerminalNumber [0] [0..39]
sapi [RSL, OML]
teiLapdLink [0..127]

availabilityStatus [{}, dependency, failed]


operationalState [enabled, disabled]
pcmCircuitId [0..47]
timeSlotNumber [1..31] (E1) or [1..24] (T1)

Create, Set, Delete, Display, Display all

NORTEL NETWORKS CONFIDENTIAL 45


lapdLink (Abis) Object (concentration
for a Bsc2G)

SICD8 Site 1

site 1 site 2 BSCB Concentration


signaling enabled
Site 2

site 3 Concentration
signaling Site 3 disabled

BSC 12000

NORTEL NETWORKS CONFIDENTIAL 46


lapdLink Object (concentration for Bsc2G)

BSCB
SITE 1
SICD8 SITE 2
SITE 3
SITE 4

SITE 5
SITE 6
SITE 7
SITE 8

SITE 9
SITE 10
SITE 11
SITE 12

SITE 13
SITE 14
SICD Port = SITE 15
LapdTerminalNumber SITE 16

BSC 12000

NORTEL NETWORKS CONFIDENTIAL 47


lapdLink Object (1)

Site lapd
signaling Site OML BCF

D
OML RSL TRX 0
BSC S
RdV TS = tei + 1 C

OML RSL TRX 7


tei

NORTEL NETWORKS CONFIDENTIAL 48


lapdLink Object (2)

SICD8

15 TEIs
per Port

64 TRXs per board

Bsce3 case: NO MORE than 8 TRXs with


the SAME value for LapdTerminalNumber

NORTEL NETWORKS CONFIDENTIAL 49


btsSiteManager Object (1)

btsSiteManager [0..146] pcmTimeSlotNumber [2] V8 [1..31]


Attenuation [2] V9 [0..14] dB radioSiteMask [2] xx..xx (x = [0,1])
bscSitePcmList [2] [pcmCircuitBsc [0..47/167], redundantPcmPresence [2] [true/false]
pcmCircuitBtsSiteManager [0..5]] siteGsmFctList [2] list of at most 14 GSM functions
btsDescription V10 [char] siteName [30 char max]
configRef [2] [V8] [YYY] (Y= [0..9], [A..V]) smoke detector [2] V9
cpueNumber [0] V12 [noValue, 0, 1] [present/absent]
external alarm configuration [2] V9 teiBtsSiteManager [2] [0..13] S12000
xxxxx...xxxxx (x = [0,1]) (48 bits) [0..158] other Sites
external battery cabinet [2] V9 [present / absent] transparentSiteAttrib2 V14 [0129] character
hardwareRef [2] [0..65535] TFH or RWM [2] V9 [present/absent]
lapdLinkOMLRef [2] [0.. infinite] unmasked users alarms [2] V9 [all masked, Base 1,
lightning protection [2] V9 [present/absent] Base 1 to 2, ..]
maxNbOfCells [2] [1..maxCellPerSite] VSWR meter [2] V9 [present / absent]

availabilityStatus [{}, dependency, failed]


cpueOccurence [0 to 2] btsDescription V10 [chain of characters]
operationalState [enabled, disabled] geographical coordinates V11
redundantPcmNumber [0..47] Deg Lat [0..90] deg
Min Lat [0..59] min
Hundredth of sec Lat [0..5999] th sec
Direction Lat [North, South]
Create, Set, Set administrativeState, Delete, Display, Display all,
Deg Lon [0..180] deg
Display hardware configuration, Display data configuration,
Use btsSiteManager battery Min Lon [0..59] min
Hundredth of sec Lon [0..5999] th sec
Direction Lon [East, West]

NORTEL NETWORKS CONFIDENTIAL 50


btsSiteManager Object (2)

RadioSiteMask
O2 S22

BSC SITE1 SITE2


PCM PCM
not used

radioSiteMask: 1 1 1 1 0 0 0 0 0 0 0 0 0 0 ......... 0 0 0 0 0
31 30 29 28 27 26 25 24 23 22 21 20 19 18 2 1 0
SITE 1 (tei=0)

radioSiteMask: 0 0 0 0 1 1 1 1 1 1 1 1 0 0 ......... 0 0 0 0 0
SITE 2 (tei=1) 31 30 29 28 27 26 25 24 23 22 21 20 19 18 2 1 0

primary lapd
channels
SITE 1 and SITE 2

NORTEL NETWORKS CONFIDENTIAL 51


btsSiteManager Object (3)

btsSiteManager 0 btsSiteManager 1
BSC bscSitePcmList 3~0 bscSitePcmList 3~0
5~1 5~1
3
0 1 0 1
PcmCircuit instance 2 3 2 3
on Bsc side
4 5 4 5
5 tei (BCF) = 0 tei (BCF) = 1

DDTI no.X pcmCircuit Bsc DTI no.X pcmCircuit


= 2X or 2X + 1 BtsSiteManager = X

NORTEL NETWORKS CONFIDENTIAL 52


ConfigRef

Example of a EFT name


for a S12000

NORTEL NETWORKS CONFIDENTIAL 53


software-btsSiteManager

Parameters involved

software [0..231-2]
sWVersionBackup [NNNabxynn]
sWVersionFallback [NNNabxynn]
sWVersionNew [NNNabxynn]
sWVersionRunning [NNNabxynn]

Create, Display, Delete


Activate new version, Return to previous version
Download, Display markers

NORTEL NETWORKS CONFIDENTIAL 54


MultipleSite Object

Two Sites Grouped in a Multiple Site

multiple site [0..146]


BSC btsSiteManagerList [2] [0..146]
radioSiteName [3] [30 char max]

NORTEL NETWORKS CONFIDENTIAL 55


BTS Object Part of parameters of bts
object

Access, Identity,Power, Radio Measures, Frequency

? ?
?
? ?
? ?
NORTEL NETWORKS CONFIDENTIAL 56
Cell Identity
bts [0..5]
baseColourCode [2] [0..7]
bCCHFrequency [2] [0..1023] F1
cellAllocation [2] [0..1023] BSIC 1
cellIdentity [2] (0..65535] F1
BSIC 0
cellName (30 Char max)
locationAreaCode [2] [0..65535]
mobileNetworkCode [2] [0..999]
mobileCountryCode [2] [0..999]
networkColourCode [2] [0..7]
standardIndicator [2] V9 [[gsm / extended gsm / dcs1800 F1
/ pcs1900 / R gsm / gsmdcs /dcsgsm / BSIC 2
gsm 850 / gsm850pcs / pcsgsm850]

BSIC

NCC BCC

3 bits 3 bits

CGI MCC MNC LAC Cell Id

3 dig 2 dig

IMSI MCC MNC MSIN


TS 0 1 2 3 4 5 6 7
15 digits or less

NORTEL NETWORKS CONFIDENTIAL 57


Technical Features
amrAdaptationSet V14 [0 to 3]
btsWithCavity [2] V12 [false, true] dtxMode [3] [msMayUseDtx, msShallUseDtx,
callClearing [3] [2..35] km if extended cell = false msShallNotUseDtx]
[2..120] km if extended cell = true emergencyCallRestricted [3] [restricted, not restricted]
cellDtxDownlink [3] (enabled, disabled] error concealment unit [2] V10 [not used, used]
extended cell [2] V9 [false, true]
cellType [3] [normalType, umbrellaType, microType] iMSIAttachDetach [2] [allowed, not allowed]
concentric cell [2] V9 [monozone, concentric, dualband, dualcoupling] interferer cancel algo usage [2] V10 [0..100] %
data non transparent mode [3] V11 [dataN2,dataN3] minNbOfTDMA [2] (0..16]
data transparent mode [3] V11 [data1, data2, data4, data8, data16, pcmErrorCorrection [2] V12 [0,1]
data32, data14_4] rxLevRxQualDistributionActivation V14 [0 to 128] Int
Data14.1OnNoHoppingTs [3] V12 [disabled, enabled] rxQualThresholdDistribution V14 [inferiorTo02 /
diversity [2] [enabled, disabled] between02and04 / between04and08 /between08and16/
nbOfFramesForFER V14 [0inf] between16and32 / between32and64 /
hrCellLoadEnd V14 [0 to 100] between64and128 / superiorTo128]
hrCellLOadStart V14 [0 to 100] smsCB [3] [used, unused]
hramrPriority V14 [0 to 2] speechMode [3] V8 [full rate, enhanced full rate]
transparentTeiAttrib2 V14 [0 to 27 character]

NORTEL NETWORKS CONFIDENTIAL 58


Cell Selection Access (1)

cellBarred [3] [barred, not barred]


cellBarQualify [3] V8 [false, true]
maxNumberRetransmission [3] [1,2,4,7]
notAllowedAccessClasses [3] [list of classes]
numberOfSlotsSpreadTrans [3] [3..12, 14, 16, 20, 25, 32, 50]
rndAccTimAdvThreshold [3] V8 [2..35] km if extended cell = false
[2..120] km if extended cell = true
rxLevAccessMin [3] [<-110, >-48]

Power in dBm

- 48

- 110
-106 dBm

-94 dBm

NORTEL NETWORKS CONFIDENTIAL 59


Cell Selection Access (2)
cellBarred [3] [barred, not barred]
cellBarQualify [3] V8 [false, true]
maxNumberRetransmission [3] [1,2,4,7]
notAllowedAccessClasses [3] [list of classes]
numberOfSlotsSpreadTrans [3] [3..12, 14, 16, 20, 25, 32, 50]
rndAccTimAdvThreshold [3] V8 [2..35] km if extended cell = false
[2..120] km if extended cell = true
rxLevAccessMin [3] [<-110, >-48]

Phase 2 mobiles Phase 1 mobiles

cellBarQualify cellBarred Cell Selection Reselection


Priority Priority
false no normal
false yes barred
true no low normal
true yes low normal

NORTEL NETWORKS CONFIDENTIAL 60


Cell Reselection
cellReselectHysteresis [3] [0..14] (step 2)
cellReselectOffset [3] V8 [0..126] (step 2)
cellReselInd [3] V8 [False, True]
penaltyTime [3] V8 [20..640] s (step 20)
temporaryOffset [3] V8 [0..70] step 10 dB

time

Cell Selection Priorities for cell types

if T< PenaltyTime then C2 = C1 + cellReselectOffset - TemporaryOffset


if T> PenaltyTime then C2 = C1 + cellReselectOffset
NORTEL NETWORKS CONFIDENTIAL 61
GSM/UMTS cell (re)selection (from V14)

1
GSM/GPRS
cell

iBTS
2
Multi mode UMTS
mobile

1 GSM to UMTS mobility


2 UMTS to GSM mobility
NORTEL NETWORKS CONFIDENTIAL 62
3G cell searching parameters at OMC-R (1/2)
BCCH
T7 T0 3G cell

Information
System
Qsearch_I
FDD_ARFCN
FDD_Qmin
FDD_Qoffset

Db iBTS

Qsearch_I

Multimode in
idle GSM MS

BTS

GSM/GPRS cells time

NORTEL NETWORKS CONFIDENTIAL 63


3G cell searching parameters at OMC-R (2/2)
BCCH
3G cell
T7 T0

Qsearch_I
FDD_ARFCN iBTS
FDD_Qmin
FDD_Qoffset
Db FDD_Qmin
CPICH Ec/No

time

Db FDD_Qoffset + RLA_Cserving
5 seconds
CPICH_RSCP
time

NORTEL NETWORKS CONFIDENTIAL 64


Radio Measurements
abisSpy [3] [not in progress, in progress]
bsMsmtProcessingMode [2] [prePocessedMeasurementReporting (BTS),
basicMeasurementReporting (BSC)]
cellDeletionCount [3] [0..31]
early classmark sending [ 3] V10 [Not Allowed, Allowed]
measurementProcAlgorithm [2] V12 [L1MV1, L1MV2]
multi band reporting [3] V10 [the six strongest cells, the strongest cell out band,
the two strongest cells out band,
the three strongest cells out band]
periodCCCHLoadIndication [3] [9.2]
plmnPermitted [3] [xxxxxxxx] (x=[0,1])
rACHLoadAveragingSlots [3] V8 [0..65535]
runCallClear [3] [1..31] 900 MHz
runHandOver [3] [1..31]
runPwrControl [3] [1..31]
unknownNCellWarning [3] [enabled, disabled] 1800 MHz

NCC 4
NCC 1

NCC 2
NCC 3

NORTEL NETWORKS CONFIDENTIAL 65


Paging
delayBetweenRetrans [2] V8 [0..22]
nbOfRepeat [2] V8 [0..22]
noOfBlocksForAccessGrant [2] [0..7]
noOfMultiframesBetweenPaging [2] [2..9]
pagingOnCell [3] V9 [disabled, enabled]
retransDuration [2] V8 [0..22] HLR/
AuC

MSC BSC

Call Setup VLR

LA 1

PSTN
LA 2

NORTEL NETWORKS CONFIDENTIAL 66


Handover
bts time between HO configuration [3] V9 [0,1]
hoMarginBeg [3] V11 [-63, 63] dB
hoTraffic [3] V12 [disabled, enabled]
selfAdaptActivation V14 [true/false]
t3103 [3] [2..255]

1 BSC

Congested

4 6

3
5

NORTEL NETWORKS CONFIDENTIAL 67


Call Queuing
allocPriorityTable [3] [0..7]
allocPriorityThreshold [3] [0..231-2]
allocPriorityTimers [3] [0..231-2]
allocWaitThreshold [3] [0..231-2]
allOtherCasesPriority [3] [0. .17]
answerPagingPriority [3] [0..17]
assignRequestPriority [3] [0..17]
callReestablishmentPriority [3] [0..17]
directedRetryPrio V12 [0..17]
emergencyCallPriority [3] [0..17]
interCellHOExtPriority [3] [0..17]
interCellHOIntPriority [3] [0..17]
intraCellHOIntPriority [3] [0.17]
intraCellQueueing [3] [enabled, disabled] Congested
otherServicesPriority [3] [0..17]

NORTEL NETWORKS CONFIDENTIAL 68


Congestion - Directed Retry

accessClassCongestion V9 [3] [list of classes]


adjacent cell umbrella ref V9 [3] [0..31]
btsMSAccessClassBarringFunction [3] V9 [disabled, enabled]
directedRetryModeUsed [3] V9 [bsc, bts]
interBscDirectedRetryFromCell [3] V9 [allowed, not allowed]
intraBscDirectedRetryFromCell [3] V9 [allowed, not allowed]
numberOfTCHFreeBeforeCongestion [3] V9 [0..128]
numberOfTCHFreeToEndCongestion [3] V9 [ 0..128]
numberOfTCHQueuedBeforeCongestion [3] V9 [0..127]
numberOfTCHQueuedToEndCongestion [3] V9 [0..127]
thresholdCCCHLoadIndication [3] [104] BSC 2
BSC 1

Congested

BCCH Reserved

TS 0 1 2 3 4 5 6 7

NORTEL NETWORKS CONFIDENTIAL 69


Frequency Hopping
btsHopReconfRestart [2] V8 [false, true]
btsIsHopping [2] [nohopping,hopping,hoppingWithCarrierFilling,
noHoppingWithCarrierFilling]
btsThresholdHopReconf [2] V8 [1..64]

frequency

F3

F2

F1

F0
time
0 1 2 3 4 5 6 7
TDMA frame 577 s
NORTEL NETWORKS CONFIDENTIAL 70
Power Control
msTxPwrMax [3]
[5..43] (2) dBm (GSM 900 / GSM 900-GSM 1800/ GSM 850 / GSM 850GSM 1900)
[0..36] (2) dBm (GSM 1800 / GSM 1800-GSM 900)
[5..43] dBm (E-GSM / GSM-R)
[0..33] (2) dBm (GSM 1900 / 1900850)
msTxPwrMax2ndBand [3] V12
[0..36 by step 2] dBm for gsmdcs dualband cell
[5..43 by step 2] dBm for dcsgsm and gsm1900850 dualband cell
[0..33] (2) dBm for gsm1900850 dualband cell
msTxPwrMaxCCH [3]
[5..43] (2) dBm (GSM 900 / GSM 900-GSM 1800 / GSM 850 / gsm850-1900)
[0..36] (2) dBm (GSM 1800 / GSM 1800-GSM 900)
[5..43] dBm (E-GSM / GSM-R)
[0..33] (2) dBm (GSM 1900 / 1900850)
new power control algorithm [3] V9 [step by step, one shot,
enhanced one shot]
powerControlIndicator [3] [include BCCH measurements, do not include BCCH measurements]
gsmtoUmtsCellReselection V14 [composed of : UMTS search min level, UMTS reselection offset
UMTS Access min level, UMTS reselection ARFCN belonging to the bts object]
frPowerControlTargetMode V14 [12.2 / 10.2 / 6.7 / 5.9 / 4.75]
hrPowerControlTargetMode V14 [[12.2 / 10.2 / 6.7 / 5.9 / 4.75]

NORTEL NETWORKS CONFIDENTIAL 71


RadioLink Supervision
callReestablishment [3] [allowed, not allowed]
radioLinkTimeOut [3] [4..64]
radResSupervision [3] V8 [False, True]
rlf1 [2] V8 [0..15]
rlf2 [2] V8 [1..4]
rlf3 [2] V8 [1..4]
+2
32
-1
-1
SACCH

+ rlf2
SACCH rlf1
- rlf3 - rlf3

NORTEL NETWORKS CONFIDENTIAL 72


Timers
timerPeriodicUpdateMS [3] [0..255](1/10s)
t3101 [3] [2..255]
t3107 [3] [2..255]
t3109 [3] [2..255] BSC
t3111 [3] [1..255]
t3122 [3] [0..255]

T3101 start CHANNEL ACTIVATION


SDCCH Allocation Signaling link
T3101 stop Allocation ESTABLISH INDICATION

T3107 start ASSIGNEMENT COMMAND


TCH Allocation
T3107 stop ASSIGNEMENT COMPLETE message

DEACTIVATE SACCH
T3109 start
Signaling link
SDCCH Release disconnection RELEASE INDICATION
T3109 stop

RELEASE INDICATION
T3111 start Signaling link
SDCCH Release
disconnection RF CHANNEL RELEASE
T3111 stop

T3122 start IMMEDIATE ASSIGNEMENT Failure


New channel Allocation
T3122 stop CHANNEL REQUEST message

NORTEL NETWORKS CONFIDENTIAL 73


adjacentCellReselection Object

adjacentCellReselection [0..31]
bCCHFrequency [3] [0..1023]
cellIdentity [3] [0..65535]
locationAreaCode [3] [0..65535]
mobileCountryCode [3] [0..999]
mobileNetworkCode [3] [0..999]
preSynchroTimingAdvance [3] V10 [-231-2 , +231-2 ] Km
standard indicator AdjC [2] V10 [gsm, extended gsm, dcs1800,
pcs1900, R gsm, gsmdcs,dcsgsm,
gsm850, gsm850pcs, pcsgsm850 ]

Create, Set, Delete, Display

NORTEL NETWORKS CONFIDENTIAL 74


powerControl Object (1)

powerControl [0..231-2]
bsPowerControl [3] [enabled, disabled]
bsTxPwrMax [3] [2..51]
lRxLevDLP [3] [<-110, >-48] dBm
lRxLevULP [3] [<-110, >-48] dBm
lRxQualDLP [3] [<0.2, >12.8] %
lRxQualULP [3] [<0.2, >12.8] %
powerIncrStepSize [3] [2, 4, 6] dB
powerRedStepSize [3] [2, 4] dB
powerIncrStepSizeUL V14 [0 to 30] dB
powerRedStepSizeUL V14 [0 to 30] dB
powerIncrStepSizeDL V14 [0 to 30] dB
powerRedStepSizeDL V14 [0 to 8] dB
uplinkPowerControl [3] V8 [enabled, disabled]
uRxLevDLP [3] [<-110, >-48] dBm
uRxLevULP [3] [<-110, >-48] dBm
uRxQualDLP [3] [<0.2, >12.8] %
uRxQualULP [3] [<0.2, >12.8] %

Create, Set, Delete, Display

NORTEL NETWORKS CONFIDENTIAL 75


powerControl Object (2)
Reduced
Power

Power Max Goals of the power control


algorithms:
reduce interference
save the battery of the MS

Parameters involved

new power control algorithm


msTxPwrMaxCCH
parameters of powerControl Object
Level Level Pmax
powerRedStepSize
Decreasing
Power
Power
Power Control
Control
ON One
ON
Shot
Acceptable Service Level

powerIncrStepSize Power Control ON Power


Increasing
Power Control
OFF Quality
Step by Step Algorithm Quality lRxQualXXP
One Shot Algorithm
NORTEL NETWORKS CONFIDENTIAL 76
handoverControl Object (1)
handoverControl [0..231-2] msRangeMax [3] [1..34] km
averagingPeriod [2] [0..255] [1..120] km if extended cell = true
biZonePowerOffset [3] V12 [-63,63] dB numberOfPwciSamples [3] V12 [0..60]
concentAlgoExtMsRange [3] V9 [1..34] km if extended cell = false powerBudgetInterCell [3] [enabled, disabled]
[1..120] km if extended cell = true pwciHreqave [3] V12 [0..16]
concentAlgoExtRxLev [3] V9 [<-110, >-48] dBm radChanSelIntThreshold [3] V8 [0..4]
concentAlgoIntMsRange [3] V9 [1..34] km if extended cell = false rxLexDLIH [3] [<-110, >-48] dBm
[1..120] km if extended cell = true rxLevHreqave [3] [1..10]
concentAlgoIntRxLev [3] V9 [<-110, >-48] dBm rxLevHreqaveBeg [3] V11 [1..10]
distHreqt [3] [1..16] rxLevHreqt [3] [1..16]
distWtsList [3] (0..100]% rxLevNCellHreqaveBeg [3] V11[1..10]
HandOver from signalling channel [3] [enabled, disabled] rxLevULIH [3] [<-110, >-48] dBm
hoMarginTiering [3] V12 [0..63] dB rxLevWtsList [3] [0..100]%
incomingHandOver [3] [enabled, disabled] rxNCellHreqave [3] [1..10]
intraCell [3] [enabled, disabled, cellTieringHandover] rxQualHreqave [3] [1..10]
intraCellSDCCH [3] V8 [False, True] rxQualDLIH [3] V12 [<0.2, >12.8] %
lRxLevDLH [3] [<-110, >-48] dBm rxQualULIH [3] V12 [<0.2, >12.8] %
lRxLevULH [3] [<-110, >-48] dBm rxQualHreqt [3] [1..16]
lRxQualDLH [3] [<0.2, >12.8] % rxQualWtsList [3] [0..100]%
lRxQualULH [3] [<0.2, >12.8] % selfTuningObs [3] V12 [pwCi distribution not sent,
missDistWt [3] [100..200]% pwCi distribution sent after gathering,
missRxLevWt [3] [0..100]% one pwCi distribution sent per hour]
missRxQualWt [3] [100..200]% small to large zone HO priority [3] V9 [0..17]
msBTSDistanceInterCell [3] [enabled, disabled] thresholdInterference [2] [-128, 0] dBm

Create, Set, Delete, Display

NORTEL NETWORKS CONFIDENTIAL 77


handoverControl Object (2): new parameters
handoverControl [0..231-2]

AmrDirectAllocIntRxLevDL V14 [110 to 48] Int


AmrDirectAllocIntRxLevUL V14 [110 to 48] Int
AmrDirectAllocRxLevDL V14 [110 to 48] Int
AmrDirectAllocRxLevUL V14 [110 to 48] Int
amrFRIntercellCodecMThresh V14 [12.2 / 10.2 / 6.7 / 5.9 / 4,75]
amrFRIntracellCodecMThresh V14 [12.2 / 10.2 / 6.7 / 5.9 / 4,75]
amrHRIntercellCodecMThresh V14 [7.4 / 6.7 / 5.9 / 4.75]
amrHRToFRIntracellCodecMThresh V14 [[7.4 / 6.7 / 5.9 / 4.75]
amrReserved V14 [0 to 0]
amriRxLevDLH V14 [ 110 to 48] Int
amriRxLevULH V14 [110 to 48] Int
capacityTimeRejection V14 [0 to 255] s
qualityTimeRejection V14 [0 to 255] s
nFRRequestedCode V14 [0 to 196] Int
nHRRequestedCode V14 [0 to 196] Int
pRequestedCodec V14 [12 to 196] in steps of 12
enhCellTieringCongifuration V14 [0 to 16] Int
nCapacityFRRequestedCodec V14 [0 to 196] Int
neighDisfavorOffset V14 [-63 to 63] dB
rxQualAvgBeg V14 [1 to 10] Int
servingFactorOffset V14 [ -63 to 63] dB

Create, Set, Delete, Display

NORTEL NETWORKS CONFIDENTIAL 78


handoverControl Object (3)

Main Causes of Handover

Poor Quality RxQual > lRxQualULH



Rescue Low Level RxLev < lRxLevULH
cases
Distant BTS distance > msRangeMax

PBGT > hoMargin


Preventive Power Budget and
Action rxLevdl < rxLevDLPBGT

NORTEL NETWORKS CONFIDENTIAL 79


handoverControl Object (4)

Choosing
Level
the Best Cell
Current cell Neighbor cell

Computing
Power Budget
hoMargin xx

Distance
HO

Neighbor cell hoMargin


Current cell
rxLevMinCell
HOSecondBestCellConfiguration
msTxPwrMaxCell

NORTEL NETWORKS CONFIDENTIAL 80


adjacentCellHandover Object
adjacentCellHandOver [0..31]
baseColourCode [3] [0..7]
bCCHFrequency [3] [0..1023]
[biZonePowerOffset [2] V12 [-63,63] dB
cellIdentity [3] [0..65535]
cellType [3] [normalType, umbrellaType, microType]
directedRetry [3] V9 [<-110, >-48] dBm
forced handover algo [3] V9 [<-110, >-48] dBm
hoMargin [3] [-63, 63] dB
hoMarginAmr [3] V14 [-63, 63] dB Create, Set, Delete, Display
hoMarginDist [3] V8 [-63, 63] dB
hoMarginRxLev [3] V8 [-63, 63] dB
hoMarginRxQual [3] V8 [-63, 63] dB
hoMarginTrafficOffset [3] V12 [0, 63] dB
hoPingpongCombination [3] V12 [List of causes]
hoPingpongTimeRejection [3] V12 [0, 60] sec
locationAreaCode [3] [0..65535]
microCellCaptureTimer [3] (algo A) [0..255]
microCellStability [3] (algo A) [0..255] dB
mobileCountryCode [3] [0..999]
mobileNetworkCode [3] [0..99]
msTxPwrMaxCell [3] [5..43] (2) dBm (GSM 900 / E-GSM / R-GSM)
[0..36] (2) dBm (GSM 1800)
[0..33] dBm (GSM 1900)
networkColourCode [3] [0..7]
offsetLoad [3] V12 [0, 63] dB
offsetPriority [3] V12 [1..5]
preSynchroTimingAdvance [3] V10 [-231-2 , +231-2 ] Km
rxLevMinCell [3] [<-110, >-48] dBm
rxLevDLPBGT [3] V11 [<-110, >-48] dBm
standard indicator AdjC [2] V10 [gsm, extended gsm, dcs1800, pcs1900, R gsm ,
gsmdcs, dcsgsm, gsm850, gsm850pcs, pcsgsm850 ]
synchronized [3] [not synchronized cells, synchronized cells,
pre sync HO with timing advance, pre sync HO, default timing advance]

NORTEL NETWORKS CONFIDENTIAL 81


frequencyHoppingSystem Object (1)
Parameters involved

frequencyHoppingSystem [0..231-2]
hoppingSequenceNumber [2] [0..63]
mobileAllocation [2] [1..124] (GSM 900)
[512..885] (GSM 1800)
[512..810] (GSM 1900)

Create, Set, Delete, Display

NORTEL NETWORKS CONFIDENTIAL 82


frequencyHoppingSystem Object (2)
The Mechanisms Parameters involved

The frequency hopping system provides


f1, f2 and f3 frequencies (mobileAllocation) hoppingSequenceNumber
mobileAllocation
A cyclic law is on use
FhsRef
(hopping sequence number=0).
maio

TDMA Frame

TDMA 0 f0 f0 f0
0 7

TDMA 1
f1 f1 f1 f2 f2 f2 f3 f1
Maio=0

TDMA 2
f2 f2 f2 f3 f3 f3 f1 f2
Maio=1
TDMA 3
Maio=2
f3 f3 f3 f1 f1 f1 f2 f3
NORTEL NETWORKS CONFIDENTIAL 83
lapdLink Object (TRX/DRX - OML and RSL)

lapdLink [0.. 231-2]


associatedInterface V8 [aBis, aTer, Agprs]
lapdConcentration [enabled, disabled]
lapdTerminalNumber [0] [0..39]
sapi [RSL, OML]
teiLapdLink [0..127]

availabilityStatus [{}, dependency, failed]


operationalState [enabled, disabled]
pcmCircuitId [0..47]
timeSlotNumber [1..31] (E1) or [1..24] (T1)

Create, Set, Delete, Display, Display all

NORTEL NETWORKS CONFIDENTIAL 84


transceiverEquipment Object

transceiverEquipment [0..15]
hardwareRef [2] [0..65535]
hardware configuration V11 [Dcu2/Dcu4/Drx]
lapdLinkOMLRef [2] [0..231-2]
lapdLinkRSLRef [2] [0..231-2]
teiTransceiverEqpt [2]
[32..39] (omnidirectional)
[32..47] (bisectorial)
[32..55] (trisectorial)
[32..63] (hexasectorial)
[14 to 55] for S12000 BTS
transceiver equipment class [2] V9 [1, 2]

availabilityStatus [{}, dependency, failed]


operationalState [enabled, disabled]

Create, Set, Set administrativeState, Delete, Display, Display all,


Display hardware configuration

NORTEL NETWORKS CONFIDENTIAL 85


software-transceiverEquipment

software [0..231-2]
sWVersionBackup [NNNabxynn]
sWVersionFallback [NNNabxynn]
sWVersionNew [NNNabxynn]
sWVersionRunning [NNNabxynn]

availabilityStatus [{}, dependency, failed]


operationalState [enabled, disabled]

Create, Display, Delete


Activate new version, Return to previous version
Download, Display markers

NORTEL NETWORKS CONFIDENTIAL 86


transceiver Object (1)
transceiver [0..15]
frAmrPriority V14 [0 to 2] Int
powerClass
[powerClass5 (GSM 900),
powerClass1 (GSM 1800/GSM 1900)]
priority [2] [0..255]
traffic PCM allocation priority [2] V9 [0..255]
transceiver zone Ref [2] V9 [0,1]
txPwrMaxReduction [2] [0..30] step 2

allocationState [available, not available, non significant]


availabilityStatus [{}, dependency, failed]
operationalState [enabled, disabled]
rmpConfState [configured, not configured, non significant]
supportingTransceiverEquipment [0..231-2]
tsConfiguration [channelType, absoluteRfChannelNo]
or [channelType, mobileAllocation,
hoppingSequenceNumber, maio

Create, Set, Delete, Display, Display all, Display channel state

NORTEL NETWORKS CONFIDENTIAL 87


channel Object (1)

channel [0..7]
channelType [2] [mainBCCH, mainBCCHCombined,
bcchSdcch4CBCH, sdcch8CBCH, sDCCH,
tCHFull, cCH, pDTCH]
If no hopping
absoluteRFChannelNo [2] [0..1023]
If hopping
fhsRef [2] [0..63]
maio [2] (0..N-1] N 64

bscTimeSlot [pcmCircuitId [0..47], timeSlotNumber [0..31]]


channel state [not created, disabled, working, free, busy, blocking, "working, blocked",
"blocking, removing", "disabled, blocked", "free, blocked", removing, available,
"working, CBCH", "busy,CBCH", "working, no CBCH", "busy, no CBCH"]

Create, Set, Delete, Display, Display all,


Set channel state, Display channel state

NORTEL NETWORKS CONFIDENTIAL 88


channel Object (2)
Mapping of Logical Channels
1 2 3 4 5 6 7 8 9 10
BCCH +
CCCH F S B C FS C C FS C C F S C C FS C C -
(downlink)
4 TS0

D0 D1 D2 D3 D4 D5 D6 D7 A0 A1 A2 A3 - - -
SDCCH/8
(downlink) D0 D1 D2 D3 D4 D5 D6 D7 A4 A5 A6 A7 - - -

BCCH Combined 51 frames ~ 235.38 ms

BCCH + -
F S B C FS C C F S D0 D1 FS D2 D3 FS A0 A1
CCCH +
4 SDCCH/4 F S B C FS C C F S D0 D1 FS D2 D3 FS A2 A3 -
(downlink)

Full Rate - Downlink & Uplink


26 frames = 120 ms
Traffic
Channel TTTTTTTTTTTTATTTTTTTTTTTT
time

NORTEL NETWORKS CONFIDENTIAL 89


transceiverZone Object

Starsky & Hutch


tadatadatada

small zone large zone

transceiverZone V9 [0,1]
transceiver equipment class [2] V9 [1,2]
zone frequency hopping [2] V9 [hopping,
Not Hopping]
zone frequency threshold [2] V9 [1..64]
zone Tx power max reduction [2] V9 [0..55] dB

Create, Set, Delete, Display

NORTEL NETWORKS CONFIDENTIAL 90


Review Exercises

NORTEL NETWORKS CONFIDENTIAL 91


Review Exercises

NORTEL NETWORKS CONFIDENTIAL 92


Review Exercises

NORTEL NETWORKS CONFIDENTIAL 93


Review Exercises

NORTEL NETWORKS CONFIDENTIAL 94


Review Exercises

NORTEL NETWORKS CONFIDENTIAL 95


NORTEL NETWORKS CONFIDENTIAL

You might also like