OVERVIEW
Mostyn Enterprises has developed a cost effective solution for protection of a field force HQ
from detection of its position by the use of EW.
Conventional Headquarters
Mostyn’s Solution
Frequency Coverage & Amplification

• Frequencies Coverage
• 1.6-30Mhz HF Band
• 32-88Mhz VHF Tactical Radio
• 88-512Mhz VHF-UHF

• RF power amplifiers
• 150W nominal VHF-UHF
• 400W nominal HF
RF Over Fibre Block Diagram

*Existing system currently in service


RF Over Fibre Specifications

Breakdown of Frequency Allocations


Parameter Value
Transmit frequency range, UHF Satcom mode 270 to 320 MHz
Receive frequency range, UHF Satcom mode 243 to 270 MHz
Transmit frequency range, VHF Lo LOS mode 30 to 110 MHz
Transmit frequency range, VHF Hi LOS mode 90 to 225 MHz
Transmit frequency range, UHF LOS mode 225 to 512 MHz
Receive frequency range, VHF Lo LOS mode 30 to 110 MHz
Receive frequency range, VHF Hi LOS mode 90 to 225 MHz
Receive frequency range, UHF LOS mode 225 to 512 MHz
Minimum guard band, Tx to Rx for LOS mode 4 MHz
RF Over Fibre Specifications
Parameter Value
Transmit power to Antenna 0 to 50 Watts
Receive signal level at Antenna -117 dBm min
Duty cycle 10% Tx, 90% Rx
Modulation modes FSK, ASK, PSK, FM, AM
All RF connectors N type with waterproof o ring seal
All fibre optic connectors Ruggedized
All data connectors Panel mount, IP68 rated.
All switches and indicators Panel mount, IP68 rated
Receive/transmit change over time 20 mSec max
Indoor unit power source Standard: Widemouth input 90 to 260 V AC
Option: 24V DC in (vehicle battery)
Max power requirement: 50 watts
Outdoor unit power source Standard: Widemouth input 90 to 260 V AC
Option: 24V DC in (vehicle battery)
Max power requirement: 300 watts
Indoor equipment housing Stand-alone box to IP67, rack shelf mountable - Ruggedized
Outdoor equipment housing Stand-alone box to IP68, mast mountable - Ruggedized
Operating temperature range, both equipments -20 to +50 deg. C
Humidity, operating and storage 0 to 90% non condensing
Altitude, operating and storage 15000 feet
Trailer
• Isometric View – Trailer doors opened
Trailer
• Front and Rear View
Trailer
• Top View
Trailer
• Side View
Trailer Specifications
• Trailer Dimensions
• Height from ground
• Width
• Length without towbar
• Length with towbar

• Trailer Cover
• Sides tied down to the sides of the trailer with zips at each end and will be
provided with 4 poles with guise so when the trailer is operational (fixed
position), the poles can hold the covers out to provide protection for the
operators.
Power source
• Fuel Cell
– Ethanol based – Diesel version in development
– 3-5kW
– 240V AC single phase
– 26V DC 50amp
– 48V DC 25amp
– Storage batteries are optional

• Backup power source


– 110/240V Output diesel generator
– Adequate fuel tank to provide 3 days at full power
• Heat exchanges used for forced air flow to reduce the thermal signature
Power Source

• Fuel tank

• Heat exchanges

• Water tank

• Under development
Cable Reels

• Under development
Cable

• Under development
Antennas

• Under development
Typical Antenna Systems
• Drawing of typical antenna systems.
Typical Antenna Systems
• Drawing of typical antenna systems.
Statistics – Remote System
• Fully operation remote system would consist of:
• Matrix switch(16x16)
• Based on Mostyn Enterprises 256x256 matrix switch.
• 4x4 quadrature lumped element hybrids
• 6x2 quadrature lumped element hybrids
• 9 power amplifiers
• 3 HF 1.6-30Mhz
• 6 VHF 30-512Mhz
• 1 fuel cell power generator
• 1 backup diesel generator
• 16 antennas – HF, VHF & UHF
• 16 cable drums with coaxial cable (100m)
• 2 cable drums with optic cable (500m-1000m)
• 1 order wire system for operator communication between remote site and main site
• Base system will able to handle 14 HF/VHF radios controlled by a 16x24 matrix switch.
• Expanded systems TBA
Matrix Switch
• The matrix switch is based on one of our standard designs and will suit the
overall requirement for the system, forming part of the switch will be
combiners, Frequency counters, bi-directional couplers, these form the test
capabilities and the safety checking system confirming the switch operates
in a safe manner including the associated equipment.
Statistics – Local System
• Fully operation local system would consist of:
• Local switching system to switch between local antennas and remote
system as required
• RF to fibre interface
• RF monitoring capabilities
• RF power attenuators with automatic output control
• Order wire system for communicating to remote location
QUESTIONS
Any questions or comments?
Engineering Capabilities
• R.F. • Analogue circuit design
o Switching Systems
• Digital circuit design
o Power Amplifiers
o Filters • Systems integration
o Splitter/combiners
 Resistive • Navigation systems
 Quadrature lumped • Data Logging
element
o HF Antenna Tuning Units • Turnkey Solutions
Contact Details

• Mostyn Enterprises (Technologies) Pty Ltd

• Unit 5/12 Severn Street

• St. Marys 2760, Australia

• Phone: +61 (02) 9194 3470

• Mobile: +61 414 716 311

• Email: btainsh@mostynent.com