You are on page 1of 13

GMAW / Mig Welding

Basic equipment setup and welding


procedures
Gas Metal Arc Welding

Is a process where a continuously fed


metal electrode ( Wire ) contacts the base
metal and produces heat . The arc is
shielded by an inert gas
GMAW Components
 DC or Direct Current power supply
 Electrode or wire feed controller
 Wire drive roller assembly
 Shielding gas source (cylinder) & regulator
 Manually held Gun & ground clamps
 Wire reel
GMAW component diagram
Gas Metal Arc Welding Principles
 Gas metal arc welding is generally used
due to the high efficiency of filler metal
that can be deposited per hour.

 GMAW is approximately 92% - 98% efficient

 GMAW requires a shielding gas


Gas Metal Arc Welding Principles
 The GMAW process is performed using
DCEP ( Direct Current Electrode Positive)

 Alternating current is never used for


GMAW

 DCEN is used only for a specialized


process using emissive electrodes
GMAW Advantages
• Welding can be done in all positions
• No slag removal required
• High efficiency
• Less work piece distortion
• Large gaps bridged easily , Good for poor
fitup
• High Weld Quality
Typical Setup for voltage
• The GMAW machine is a “Constant Voltage” power
supply. This is set using the voltage dial

• This setting can be monitored by the “Volt” meter


on the front panel of the welder

• Ideal voltage settings can be found in the wire


manufactures data book
Typical Setup for Wire speed
• The wire feed rate or speed is set using the dial on the
wire controller This setting increases or decreases
current or “Heat”. This setting is measured in AMPS or
IPM (inches per minute )

• Ideal settings can be monitored by the “Amp” meter on the


front panel of the welder. Note : Some machines display
“Current” (Same as AMPS) or IMP

• Ideal settings can be found in the wire manufactures data


book for both IPM and Current
Shielding Gas
• Air in the welding zone is displaced by inert gas to
“Shield” the molten weld pool and prevent it from
contamination from Oxygen, Nitrogen and Water
present in the atmosphere.
• Insufficient gas flow will not displace the
atmosphere resulting in “porosity” or voids in the
deposited weld.
• Flow is measured in CFH (Cubic Feet per Hour).
Insufficient Shielding Gas coverage

• Gas not turned on


• Flow rate not properly adjusted
• Leaks in the hose supplying the shielding
gas to the machine
• GMAW / MIG Gun loose at wire drive
connection
• Spatter buildup on gas cup
• Windy environment
Excessive Gas coverage
• Will cause porosity.
• The turbulence caused by the rapid flow of
shielding gas exiting from the gas cup will
draw the surrounding atmosphere into the
stream of gas.
• It will reduce weld pool temperatures
causing decreased penetration .
Check the Manufactures data for
settings