An Overview
Validation - What is it?
Test your system, using a defined test method
---------------------------------------------------------------------------------------------------------------------------
Your site will repeat some, but not all, test results generation at
the Performance Qualification (PQ) stage, before you GO-LIVE
QA Approves the Validation Master Plan
QA are the group who ‘approve’ the VMP.
They will want to see plans before testing
begins, followed by detailed test
documentation, which clearly explain how
the testing should proceed.
After testing, the ‘approvers’ must be able
to make a judgement, that the actual
results are correct and reflect the intent of
the testing.
3WS – an example of a computer system –
is driven by many parameters, which must be established before validation starts
So how do you separate each
component of a Validation project?
Software testing
Hardware installation
Hardware testing
Standard Operating Procedures (SOP)
Network setup
Interfaces (Software or Hardware?)
Audit trail of changes to data
Tracking changes to systems (version mgt)
System Upgrades – how to validate
Validation Planning. Identify which parts of the system
are Hardware, Software or other aspects, such as SOP etc
File Server setup during
SW / OQ ERP System installation of the system
HW/ IQ
Work Stations setup during
SW / OQ 3WS Dispensing
installation of the system HW/ IQ
SW / OQ PLC System PLC Installation during
installation of the new system HW / IQ
SW / OQ Audit Trail / Logging
PLC Configuration SOP
SW / OQ Software Configuration Setup hardware - balances,
printers, scanners, tablets, etc SOP
SW / OQ Write Test Scripts
System Backup, Restore,
Security, New User, New PC SOP
SOP Write SOPs on setup
NEW SYSTEM
VALIDATION
Each Test Script has a structured format, detailing the Test No,
Description, Method to be used and Expected Results.
The bottom of the test script should be hand-written after the
test is complete: Actual Result, Tested By, Reviewed By,
numbered References and finally, a Pass or Fail status.
One DOC for each Test Result
Example Test for LOT NO
Chapter 13 Test 190 (C13T190.doc)
This test adds a New record and then confirms that the
Weight Received is not less than the Weight Approved.
VALIDATION
Hardware includes thermal printers ,
barcode scanners and electronic balances
Balance testing!
Either:
Attach printed label to
the Test Result
Or