You are on page 1of 16

illbruck intelligent building systems

SEALING MATERIALS AND SYSTEMS FOR ROOFING , CLADDING AND FACADES

CONTENTS
ROOFING AND CLADDING

AL + GLASS FACADES

STONE AND CERAMIC FACADES


ROOFING, CLADDING 2
TYPES OF CONSTRUCTIONS 2
PREFAB SENDWICH PANELS

COMPOSITE VENTILATED SYSTEMS


COMPOSITE SYSTEMS – EXTRNAL EFFECTS vs REQUIREMENTS 2

EXTERNAL EFFECTS

1. WIND

2. RAIN

3. DILATATIONS

4. MOISTURE INFILTRATION

5. HEAT LOSS

FUNCTION REQUIREMENTS

1. ZERO WIND INFILTRATION

2. ZERO WATER INFILTRATION

3. THERMAL AND NOISE BARRIER

4. LONG LIFETIME
Ability of dilatation movements
Prevention of water condensation
COMPOSITE SYSTEMS – illbruck solution 2

CLADDING

1. SETTING OF PARTS

2. MUTUAL CONNECTION

3. CONNECTION ON OTHER CONSTRUCT.

4. CONNECTION WITH AL+GLASS


or STEEL+GLASS CONSTRUCTIONS

5. FIXINGS

STEEL CONSTRUCTIONS

1. FIXINGS
PU PANELS – MINERAL WOOL PANELS 2 SIDE WALL CONNECTION

DETAIL 1 – connection of panels

EXTERIER : PVC or butyl tape - roof panel


PU tape – side wall panel
MIDDLE PART : PU tape ( foam )
INTERIER : Butyl tape or butyl round profile

Butylový provazec

PU páska
PVC or Butyl tape

ROOF CONNECTION

Butylový provazec

MOST COMMON MISTAKES :THE SEALING IS COMPLETELY MISSING OR THE MATERIAL OF THE SEALING IS WRONG
PANELY –– ČEDIČOVÉ
PU PANELS PANELY
MINERAL WOOL PANELS 2 2
DETAIL 2 – connection of panels

INTERIER : PVC or butyl tape ( PU or PE )


MIDDLE PART : PU tape ( foam )
EXTERIÉR : Butyl tape – roof panels
PU komprimated tape – side wall panel

SIDE WALL

ROOF CONNECTION
PVC páska

PU páska ( PU pěna )
PU PANELS – MINERAL WOOL PANELS 2

DETAIL 3 – connection between base frame and window

INTERIÉR : PE round prifile + silicone sealant


MIDDLE PART: PU foam
EXTERIÉR: PU tape illmod 600

PE provazec + silikon PRN illbruck „i3“ window sealing system

PU páska illmod 600


COMPOSITE SYSTEMS 2
DRAINING CANAL
DETAILS 4,5,6

PANEL and BASE CONSTRUCTION

CORNER

Butyl Tape

PVC or butyl tape


COMPOSITE SYSTEMS 2
DETAIL 7 – connection of monitor top (roof light)

INTERIÉR : Butyl tape


MIDDLE PART : Mineral wool insulation
EXTERIÉR : PCV páska + EPDM fólie FF 220
COMPOSITE SYSTEMS 2

TRAPEZ PLATES
TRAPEZ PLATES 2
IZOTHERMAL FLOW WITHOUT THE INSULATION MATERIAL

CONDENSATION OF THE INTERNAL MOISTURE ( Internal temperature 21°C a 50% relativní vlhkosti )
při 10.2°C NA VNITŘNÍ STRANĚ PLÁŠTĚ

IZOTERMICKÝ TOK s tepelně izolačním materiálem

DISTANČNÍ PROFIL 30x200 mm


SKLÁDANÉ PLÁŠTĚ 2
C KAZETY + TRAPÉZOVÝ PLECH

SOUČASNÝ STAV : VĚTŠINA SKLÁDANÝCH PLÁŠŤŮ NESPLŇUJE POŽADAVKY TEPELNĚ TECHNICKÉ NORMY !!!
UKÁZKY A PRAXE

DISKUZE
Illbruck
kontakt

KONTAKT

illbruck Building Systems s.r.o.


Úvalská 737/ 34
CZ – 100 00 Praha 10

tel.: +420 – 296 565 333


fax: +420 – 296 565 300
e-mail: prodej@illbruck.com