Professional Documents
Culture Documents
FO NAST3028 LTE Handover Optimization 35P
FO NAST3028 LTE Handover Optimization 35P
Contents
Basic Concepts
Handover Signaling Procedure
Handover-related Radio Parameters
Case Study
Basic Concepts (1)
User plane
S1-AP
PDUs
GTP-U
SCTP
UDP
IP
IP
Data link layer
Data link layer
Physical layer Physical layer
Basic Concepts
Handover Signaling Procedure
Handover-related Radio Parameters
Case Study
Signaling Procedure – Intra-eNodeB Handover
eNodeB
Source Target S1 S11 S5 PDN-
UE MME S-GW
CELL CELL GW
Handover
decision
Preparation Phase
Handover
Request
Radio Resource
Allocation
Handover Request ACK
RRC Reconfiguration
(Handover Command)
Handover Confirm
(Synchronization, RRC
Execution Phase
Reconfiguration Complete)
Release
Resource
Radio Resource
Release
BeforeMMEhandover UE
Source
eNodeB
Target
eNodeB
S1 MME
S11
S-GW
S5
PDN-GW
Handover
S1 S1 decision
Handover Required
Preparation Phase
Handover Request
X2
eNodeB2 Radio Resource
eNodeB1
allocation
Handover Command
Handover Confirm
After handover Handover Notify
Execution Phase
User Plane Update Response
X2 Radio Resource
eNodeB2 Release
eNodeB1
UE Context Release Complete
Uu
Before handover UE
Source X2 Target
MME
S1
1 S-GW
S5 PDN-
eNodeB eNodeB GW
Handover
S1 S1 decision
Preparation Phase
Handover Request
X2
eNodeB2
eNodeB1 Radio Resource
Allocation
Handover Request ACK(Handover
Command)
Uu Handover Command
Handover Confirm
Path Switch
Request
User Plane Update
After handover Request
User Plane Update
Execution Phase
Response
MME Path Switch Request
ACK
Release Resource
S1 S1 Radio Resource
Release
X2
eNodeB2
eNodeB1
Uu Uu
Basic Concepts
Handover Signaling Procedure
Handover-related Radio Parameters
Case Study
Radio Parameters (1) -- Measurement
Parameters configuration
a3-Offset
Off in the entering/leaving condition is a3-Offset
Its default value is 3 dB
The recommend value is 2, 3 or 4 dB. A greater or smaller value is
not recommended because it may lead to delayed handover and
too many handovers at a time
This offset is applicable to all neighbor cells
TimeToTrigger (TTT)
This parameter specifies the value range used for time to trigger parameter, w
hich concerns the time during which specific criteria for the event needs to be
met in order to trigger a measurement report.
Value range: enumerated (0, 40, 64, 80, 100, 128, 160, 256, 320, 480, 512, 640,
1024, 1280, 2560, 5120)
Default value: 320 ms 。
A high TTT can put off measurement reporting and reduce handovers.
Recommended values: 256, 320, 480, 512 or 640 ms.
Hysteresis
Hysteresis, used to adjust the entering/leaving threshold of event-triggered r
eporting, determines the period the UE stays at Event A3.
Default value is 0 。
If ReportOnLeave is not enabled , the recommended value is 0 。
ReportOnLeave
This parameter indicates whether or not the UE shall initiate the measurement
reporting procedure when the leaving condition is met.
tAmount
ReportInterval and reportAmount
Event triggering: reportInterval shall be used with reportAmount. When repor
tAmount is greater than 1, reportInterval is valid.
Periodical reporting: ReportInterval is the period to report the measurement
Value range of ReportInterval: enumerated (120, 240, 480, 640, 1024, 2048, 51
20, 10240, 60000, 360000, 720000, 1800000, 3600000), unit: ms
Value range of ReportAmount: enumerated (1, 2, 4, 8, 16, 32, 64, Infinity), unit:
times
Recommend value for ReportInterval is 480ms, and that for ReportAmount is
4.
T304
Timer waiting for handover success
Value range: enumerated (50, 100, 150, 200, 500, 1000, 2000), unit: ms
Default value: 1000 ms
Basic Concepts
Handover Signaling Procedure
Handover-related Radio Parameters
Case Study
Case Study
Problem description
Problem description
After receiving a handover reque
st from an eNB, the MME process
es the request.
If the MME receives another han
dover request from the eNB withi
n 1s, it will ignore this second ha
ndover request.
Problem analysis
Current parameter configuration
HO Prepare Timer = 1 s
(Upon receiving one UE’s MR request, the source eNB sends the “handoverRequi
red” messages to MME at an interval of 1 s.)
Intra-frequency Reporting Interval for Event = 1024 ms
Intra-frequency Amount of Reporting for Event = 1
(If the target cell meets the MR reporting criterion, the UE reports MR every 1024ms
and the total times is 1.)
If the UE performs handover to two neighbor cells one by one in 1 second, an
d the amount of reporting is only 1, the second handover request message wi
ll be bypassed by the 1s timer on the core network side. As a result, the hand
over fails and call drop occurs.
eNB
950 ms
UE
0 480 ms 960 ms 1440 ms 1920 ms 2400 ms 2880 ms
Problem solution
Setting
Parameter Explanation
before after
In an S1-based handover, the source eNB sends
the HandoverRequired message to the core
network, and starts this timer; After receiving
HO Prepare Timer 1s 950 ms
handover command from the core network, it
stops this timer. If the timer reports a timeout, it
means an abnormality.
Intra-frequency
The parameter indicates the interval to report the
Reporting Interval for 1024 ms 480 ms
MRs interval after event triggering.
Event
Intra-frequency
The parameter indicates the maximum report
Amount of Reporting 1 4
times after event triggering.