X-12 CTU – Operator Training


Operation System Set-up
Agenda

 Network Connection. (Checking communication)


 Set- up Well Restrictions
 Set- up Main
 Set-up Injector
 Set-up HPU
 Set-up BOP skid
 Set-up Misc
 X-12 Check list set up

2
Network Connection

3
HMI- WinCC

4
Network Connection

5
Network Connection

Show communication lines


and status between units

Type of unit that is in used

1 HPU and 1 BOP 2 pumps can be connected


connected at a time at a time

6
Set- up Well Restriction

7
Set-up WellRes

8
Set-up WellRes

Adding restriction:
Fill in desired values for Start,
Stop and Speed. Press
Restriction button, below Add
as text. Continue until all
restrictions are registered.

Adding stop points:


Fill in the Stop and Start field
(same depth), leave Speed at
0. Press Stop button below
Add As text.
 Removing restriction:
Fill in desired restriction
number in the Remove Well
Restriction, Restriction # field.
Touch Remove button

9
Set- up Main

10
Set-up Main

On the setup main page it is


Chain Lubing
possible Off Distance
to change SI /APIset
point for how
values far gauges
for the betweenand
each
pressurelubrication.
readings displayed
on the main page

Lewelwind control up and


Maintenance
down in additionmode
to lefton/off
joystick
Reel up
direction Forward /
and down..
Reverse. This option is only
available in maintenance
mode.

11
Set- up Injector

12
Set- up Injector

Unit selection (Bar- Psi)

Encoder selection

Weight offset

Depth adjustments

13
Set-up Injector
Encoder selection

BOTH tubing encoders JUST one tubing encoder Neither tubing encoder

 Tube Depth is calculated  Depth is calculated using  Tube depth is calculated


using UTLM algorithm only the selected Encoder. using Chain Encoder.
applied to both Encoder
values.
 Tube Slip is available using  Tube Slip is not available
 Tube Slip is available using the Injector chain Encoder as
the Injector chain Encoder as reference.
reference.

Note: The injector WILL NOT run if none of the 3 depth encoders are connected

14
Set-up Injector
Weight offset Depth adjustments

 Zero weight resets the  Zero Depth is calculated by


injector weight to zero. adjusting the A, B and C
values
 This is done by reading the
current raw value and setting  Only 1 depth. (no measure
this as “current offset” depth or correct depth)

 The current offset is displayed  An specific depth value can


be sent to the PLC during the
 Reset offset removes the job by typing in a new depth
current offset and returns the value and send it to the PLC.
injector weight to the original Current Depth value will be
load cell raw value. updated

15
Set- up HPU

16
Set-up HPU

Possible to change SI /API


values for the gauges and
pressure readings displayed
on the HPU page.

17
Set- up Pump

18
Set-up Pump page 1

Allows to change SI /API


values for the gauges and
pressure readings
displayed on the pump
page 1 page.

Allows to change the Max


rate SP limits, which is the
max rate on the pump when
running the pump in rate
mode.
 

19
Set-up Pump page 2
Allows to change SI /API
values for the gauges and
pressure readings
displayed on the pump
page 2 page.

Fluid Pump flowmeter


calibrating settings
calibrates the external
flowmeter connected to the
flow line.

20
Set- up BOP Skid

21
Set-up BOP Skid page 1

Allows to change SI /API


values for the gauges and
pressure readings
displayed on the BOP
page.

It is possible to type in the


name of the rams in use. It
will be shown on the BOP
page

22
Set-up BOP Skid page 2

On the setup BOP page 2


the open and close volume
on the BOP rams are set.
The rams need to open /
close 75 % of this volume in
22 seconds or an alarm will
be given

23
Set- up Alarms

24
Set-up Alarms

25
Set- up Misc

26
Set-up Misc

Numbers of cameras
connected to the unit can
be selected. One is default,
three is maximum.

Here units can be changed


for all values. It is also
possible to save and load
unit selection settings to
file.

Start OPC Gateway will


start the OPC gateway
communication with the
Coil Cat PC