SERVICES
LAUNDRY
CSSD
DIAGNOSTIC SURGERY DELIVERY KITCHEN
STORE
DIAGNOSIS AND
TREATMENT
PATIENTS
VISITORS
SERVICES
OUT PATIENT DEPARTMENT
DIAGNOSTIC FACILITIES
DRUG DISPENSARY
TREATMENT
CONSULTANT’S OFFICE
DRESSING
PATIENTS
PATIENTS STAFF CLEAN SUPPLY OPERATING STAFF
USED SUPPLIES
FACT FILE
BUILDING:- 400 BED DISTRICT
HOSPITAL AT JALANDHAR ,
PUNJAB . A WORLD BANK FUNDED
PROJECT.
CLIENT :- PUNJAB HEALTH
SYSTEM CORPORATION LIMITED.
1. MAIN HOSPITAL
9 2. PHYSIOTHERAPY
3. LAUNDARY
8 10 4. P.P UNIT
6 5. MATERNITY BLOCK
6. STAFF QUARTERS
5 7. C.M.O. RESIDENCE
7 8. NURSES HOSTEL
2 3 9. CLASS III STAFF
1
10. CLASS IV STAFF
4
11. C.M.O. OFFICE BLOCK
11
400 BED CIVIL HOSPITAL AT JALANDHAR
S.F. PLAN
G.F. PLAN F.F. PLAN
400 BED CIVIL HOSPITAL AT JALANDHAR
BASEMENT PLAN
SECTION
400 BED CIVIL HOSPITAL AT JALANDHAR
THIS 400 – BED CIVIL HOSPITAL HAS BEEN DESIGNED KEEPING THE USER
GROUP IN THE FORE.
RESPONDING TO THE REQUIREMENTS OF THE PATIENT CARE , NEEDS,
CULTURES, CLIMATE, SITE AND BUDGET A PLAN FORM IS DEVELOPED
AROUND THE COURTYARD WHICH BROADLY SEGREGATES THE NURSING
ZONE , THE CLINICAL ZONE AND THE SUPPORT ZONE OF THE HOSPITAL.
SUPPORT ZONE
THIS HOSPITAL HAS BEEN DIVIDED INTO
THREE ZONES :- NURSES ZONE
CLINICAL ZONE – 55 %
CLINICAL ZONE
NURSES ZONE – 33 %
SUPPORT ZONE -12 %
NURSING ZONE:- THE NURSING UNITS OR MORE COMMONLY REFFERED TO
AS THE WARD BLOCKS HAVE BEEN DETAILED VERY MINUTELY.
THE PATIENT SPACE , STAFF SPACE & CIRCULATION SPACES HAVE BEEN
DISTINCTLY DEFINED AND JUXTAPOSED SUCH THAT EACH COMPLIMENTS
THE OTHER.
400 BED CIVIL HOSPITAL AT JALANDHAR
CLINICAL ZONE :-
ONE OF THE MOST SIGNIFICANT AREA OF THIS
HOSPITAL IS THE CLINICAL SKILLS.
IT INCLUDES:-
1. EMERGENCY UNIT
2. OUT PATIENT DEPARTMENT
3. RADIOLOGY UNIT
4. PATHOLOGY UNIT
5. OPERATION THEATRE COMPLEX
6. I.C.U. UNIT
SUPPORT ZONE :-
IT IS THE THIRD MAIN SECTION OF THIS HOSPITAL .
IT INCLUDES ADMINSTRATIVE AREA SUCH AS N.S
OFFICE BLOCK, M.S OFFICE BLOCK ; C.S.S.D UNIT.
ITS PURPOSE IS TO SATISFY ALL THE PHYSICAL ,
MATERIAL AND FUNCTIONAL NEEDS OF THE NURSING
400 BED CIVIL HOSPITAL AT JALANDHAR
CONCEPT
SEPARATE ALL DEPARTMENTS ,YET KEEP THEM ALL CLOSE
TOGETHER, SEPARATE TYPES OF TRAFFIC, YET SAVE STEPS FOR
EVERYBODY, THAT IS ALL THERE IS TO HOSPITAL PLANNING.
EMERSON GOBLE…..
FLOOR PLAN
CENTRAL COURTYARD
A CONVENIENT
CIRCULATION PATTERN
HAS BEEN ADOPTED IN
THE PLAN WHICH
REVOLVES AROUND THE
CENTRAL COURTYARD .
THIS FACILITATES
EASY ACCESS TO THE
VARIOUS
DEPARTMENTS OF THE
HOSPITAL AND HELPS
MAINTAIN EFFECTIVE
ADMINISTRATIVE
CONTROL
400 BED CIVIL HOSPITAL AT JALANDHAR
AREA STATEMENTS
5 RADIOLOGY BLOCK
OPD
BLOCK 6 1. COURTYARD
2. RAMP
5
3. STAIRCASE
4. LIFT
6
4 5. FIRE
3 1 ESCAPE
3
2 STAIRCASE
4 6. TOILETS
2
OPD BLOCK
EMERGENCY BLOCK
5 2
MAIN ENTRANCE
400 BED CIVIL HOSPITAL AT JALANDHAR
X-RAY TREATMENT
ROOM MINOR ROOM
O.T.
MEDICO LAB
LEGAL
EMERGENCY
RECEPTION ENTRANCE
WARD
DUTY
ROOM
SEPARATE ENTRY TO THE
EMERGENCY BLOCK IS
CLEARLY VISIBLE FROM THE
MAIN ENTRANCE TO THE
EMERGENCY BLOCK HOSPITAL.
THE EMERGENCY BLOCK HAS
BEEN LOCATED ON THE
GROUND FLOOR WITH THE
EASYACCESS BOTH FROM
INSIDE AND OUTSIDE THE
HOSPITAL.
400 BED CIVIL HOSPITAL AT JALANDHAR
RECEPTION OF THE
EMERGENCY BLOCK.
SURGICAL
PLASTER ROOM TREATMENT
SURGICAL
ORTHOPAEDIC OPD
SURGICAL
OPD
TREATMENT
ROOM WAITING
EYE
OPD MEDICAL
OPD
EYE MEDICAL
OPD OPD MEDICAL
EYE
OPD
OPD
DENTAL PHARMACY
DENTAL
OPD DISTRIBUTION
OPD
PHARMACISTS
PLASTER
ROOM
ROOM
WAITING
ENT
OPD
SKIN
OPD
ENT PHYCHI- SKIN
OPD ATRY OPD
SKIN
OPD
CONTROL RADIOGRAPHY
ROOM CT DARK
ROOM DRYING
SCAN
RECEPTION
RADIO-
STORE
TECHNICIAN
GRAPHY ROOM
ULTRASOUND
ROOM
RADIOLOGIST
ROOM
THE ROLE OF RADIOLOGY DEPARTMENT IS RADIO-DIAGNOSTIC AND
RADIOTHERAPY . THE DIAGNOSTIC UNITS GENERALLY DEALS WITH
ULTRASOUND, CT SCAN ETC.
ITS FUNCTION IS TO PHOTOGRAPH , PROCESS THE FILM AND PROVIDE
FACILITIES FOR ITS INTERPRETATION AND STORAGE.
EASY ACCESSIBILITY FOR THE PATIENTS AND TO OTHER ACTIVITY AREAS
OF THE HOSPITAL GOVERNED THE LOCATION OF DIAGNOSTIC BLOCK.
400 BED CIVIL HOSPITAL AT JALANDHAR
5
PATHOLOGY
BLOCK 6
N.S. OFFICE 1. TERRACE
BLOCK
2. RAMP
5 3. STAIRCASE
4. 4. LIFT
6
3. 3. 5. FIRE
2. 4. ESCAPE
STAIRCASE
1.
5 1. 6. TOILET
C.S.S.D
BLOCK
M.S. OFFICE
BLOCK
STAFF
RECORD
ROOM LAB LAB
ROOM
RECEPTION
WAITING
RECORD
ROOM
LABORATORY
400 BED CIVIL HOSPITAL AT JALANDHAR
N.S. OFFICE BLOCK
NURSING
GENERAL SUPDT.
LECTURE
STAFF.
HALL
STAFF
ROOM
ASTT.
SUPDT.
ASSTT.
MEDICAL SECURITY
SUPDT. OFFICE
GENERAL
STAFF.
. ADMN. RECORD
OFFICE ROOM
CONFRENCE
ROOM. PURCHASE
ROOM
MEDICAL ACCOUNTANT
SUPDT.
ROOM
WARD BLOCK
WARD
BLOCK
WARD
BLOCK
WARD BLOCK
400 BED CIVIL HOSPITAL AT JALANDHAR
WARD BLOCK
WARD
WARD WARD
DOCTOR’S ROOM
NURSES ROOM
TREATMENT
ROOM
WARD WARD
PANTRY
O.T. BLOCK
I.C.U
BLOCK
WARD
BLOCK
400 BED CIVIL HOSPITAL AT JALANDHAR
O.T. BLOCK
PREPARATION
ROOM
NURSES
ROOM
OT
OT RECOVERY
SCRUB
STORE
OT CHANGE
DU OT
ROOMS INCHARGE
DOCTOR’S
ROOM ROOM
NURSES
ROOM
I.C.U. WARD
LAB
STORE PANTRY
DOCTOR’S LAB
WAITING
ROOM
ROOM
STORES BLOCK
WORKSHOP
TELEPHONE BLOCK
EXCHANGE
COMPACT
EARTH
FILLING
A.C / HVAC
MEDICAL
STORES
BLOCK
MACHINERY &
EQUIPMENT
BLOCK
400 BED CIVIL HOSPITAL AT JALANDHAR
CIRCULATION
SHOWING GENERAL
CORRIDOR.
400 BED CIVIL HOSPITAL AT JALANDHAR
O.T. BLOCK
DIRTY CORIDORS :-
USED TO CARRY OUT THE WASTE FROM O.T.
WIDTH- 5’-6”
CLEAN CORRIDORS :-
ENTRY OF GENERAL PUBLIC IS RESTRICTED.
USED BY THE PATIENTS AND DOCTORS.
DIRTY
CORRIDOR
CLEAN
CORRIDOR
400 BED CIVIL HOSPITAL AT JALANDHAR
STERILE CORRIDORS :-
IT LEADS TO THE OPERATION
THEATRE.
ENTRY OF GENERAL PUBLIC IS
RESTRICTED BECAUSE THIS IS THE
AREA WHERE MAXIMUM CLEANLINESS
IS REQUIRED. STERILE
CORRIDOR
WIDTH –10’ BECAUSE STRETCHER
MOVEMENT IS THERE.
THESE CORRIDORS ARE WIDE AND
STRAIGHT WITHOUT ANY HINDERANCE
FOR THE PROPER FUNCTIONING OF
THE HOSPITAL.
VERTICAL CIRCULATION :-
STAIRCASES
ELEVATORS
RAMPS
400 BED CIVIL HOSPITAL AT JALANDHAR
STAIRCASES :-
IN THIS HOSPITAL STAIRCASES ARE DESIGNED SUFFICENTLY WIDE TO ENSURE EASY
MOVEMENT OF TRAFFIC.
WIDTH-2000 MM, TREAD-300 MM, RISER-152 MM, NO.’S-24.
THESE ARE PLACED IN SUCH A WAY THAT THESE ARE VISIBLE THROUGH A DISTANCE
AND ALSO SEPARATE THE TRAFFIC TO THE DIFFERENT BLOCKS.
THERE IS ONE FIRE ESCAPE STAIRCASE IN EACH BLOCK.
WIDTH-1200 MM, TREAD-270 MM, RISER-166 MM, NO.’S- 22.
FIRE ESCAPE
STAIRCASE FROM
OUTSIDE.
400 BED CIVIL HOSPITAL AT JALANDHAR
ELEVATORS :-
ELEVATORS ARE THE MECHANISM INSTALLED FOR THE VERTICAL ASCEND
AND DESCEND OF PEOPLE AND GOODS.
A TOTAL OF FOUR ELEVATORS ARE PROVIDED IN THE BUILDING WITH THE
TWO GROUPED TOGETHER IN THE MAIN CIRCULATION AREA.
THE SIZES –2350 MM X 3000 MM & 1700 MM X 3000 MM .
400 BED CIVIL HOSPITAL AT JALANDHAR
RAMP :-
IT PROVIDES CONVENIENT CIRCULATION TO INHOUSE PATIENTS.
THE WIDTH OF RAMP IS 2470 MM .
CHECKERED TILES WHICH ARE ANTI-SKIT HAS BEEN USED AS THE FLOOR
FINISH OF THE RAMP.
RAMP BLOCK
FROM OUTSIDE
400 BED CIVIL HOSPITAL AT JALANDHAR
ELEVATION
FRONT ELEVATION
SIDE VIEW
FRONT VIEW
400 BED CIVIL HOSPITAL AT JALANDHAR
MAIN ENTRANCE
EMERGENCY
ENTRANCE
400 BED CIVIL HOSPITAL AT JALANDHAR
SHOWING MAIN
ENTRANCE.
400 BED CIVIL HOSPITAL AT JALANDHAR
LONGITUDINAL SECTION
400 BED CIVIL HOSPITAL AT JALANDHAR
INCINERATOR :-
o IT IS THE BEST METHOD OF ELIMINATING ANY INFECTIOUS ORGANISMS THAT ARE
PRESENT IN MEDICAL WASTE.
o INCINERATION HAS BEEN ECONOMICAL BECAUSE IT REDUCES THE VOLUME TO BE
DISPOSED OF IN A LANDFILL.
o WASTE IS BURNT AT VERY HIGH TEMPERATURES.
400 BED CIVIL HOSPITAL AT JALANDHAR
AUTO CLAVES:-
o IN AUTOCLAVES, THE EFFECTS OF HEAT FROM SATURATED STEAM AND INCREASED
PRESSURE DECONTAMINATE MEDICAL WASTE BY INACTIVATING AND DESTROYING
MICROORGANISMS.
o PRE- VACCUM AUTO CLAVE HAS BEEN USED.
CHEMICAL TREATMENT :-
o IN CHEMICAL TREATMENT SYSTEMS, AN ANTI-MICROBIAL CHEMICAL, SUCH AS
SODIUM HYPOCHLORITE, CHLORINE DIOXIDE, OR PERACETIC ACID,
DECONTAMINATES THE MEDICAL WASTE.
MICROWAVE RADIATION :-
IN MICROWAVE RADIATION, MEDICAL WASTE ENTERS THE SYSTEM BY
CONTINUOUS MODE, WHERE IT IS WETTED WITH STEAM OR WATER AND
HEATED BY MICROWAVE RADIATION AT DE-CONTAMINATING
TEMPERATURES.
DISPOSAL OF PATHOLOGICAL WASTE :-
PATHOLOGICAL WASTE (BODY PARTS, RESEARCH ANIMALS, ETC.)
CANNOT BE DISPOSED OFF BY AUTOCLAVING. FOR DISPOSAL OF SUCH
WASTE, EITHER CREMATORIA (BURNING OF THE BODY) OR BURIAL SHOULD
BE PERFORMED.
SERVICES
400 BED CIVIL HOSPITAL AT JALANDHAR
FIRE FIGHTING :-
FIRE FIGHTING REMAINS THE MOST IMPORTANT SERVICE OF THE BUILDING
WITHOUT WHICH A BUILDING WOULD BE HANDICAPPED, IT INCLUDES:-
FIRE PUMP & ACCESSORIES.
FIRE HYDRANT AND WET RISER SYSTEM.
AUTOMATIC SPRINKLER SYSTEM.
PORTABLE FIRE EXTINGUISHERS.
FIRE HYDRANT & WET RISER SYSTEM:-
o IN THIS THE HYDRANT RING MAIN FROM FIRE PUMPS WILL RUN ALL AROUND
PROPOSED BUILDINGS WITH YARD HYDRANTS AT SUITABLE INTERVALS. WET
RISERS SHALL BE TAPPED FROM RING MAIN AND RUN ALONG THE SHAFT.
o FIRE HOSE CABINET ARE PROVIDED ON ALL FLOORS WITH ACCESSORIES.
o THIS SYSTEM CONSISTS OF:
--FIRE RING MAIN WITH YARD HYDRANTS.
--WET RISERS SERVING ALL LEVELS WITH SINGLE HEADED LANDING
VALVES,FIRST AID FIRE HOSE REEL AND OTHER ACCESSORIES.
400 BED CIVIL HOSPITAL AT JALANDHAR
FIRE EXTINGUISHERS :-
o PORTABLE TYPE CLASS A,B & C FIRE EXTINGUISHERS
ARE PROVIDED AT ALL FIRE SENSITIVE PLACES WHOSE
LOCATIONS ARE DECIDED ON FLOOR AREA BASIS.
400 BED CIVIL HOSPITAL AT JALANDHAR
AIR CONDITIONING:-
TOTAL LOAD
LIGHTING & POWER 300 KW
A/C - 550 KW
LIFTS 100 KW
APPROXIMATELY 1000 KW
CONSUMPTION.
400 BED CIVIL HOSPITAL AT JALANDHAR
WATER SUPPLY :-
WATER SUPPLY NEEDS OF THE BUILDING ARE CATERED BY:-
a) AN UNDERGROUND TANK OF 1,00,000 LITRES CAPACITY.
b) AN OVERHEAD TANK OF 20,000LITRES CAPACITY
o THE UNDERGROUND WATER TANK CONSISTS OF 2 EQUAL
SIZED COMPARTMENTS.50% OF THE TOTAL WATER IS USED
FOR DOMESTIC PURPOSES AND THE OTHER 50% IS USED
FOR FIRE FIGHTING PURPOSES.
o THE OVERHEAD TANK IS EXCLUSIVELY FOR FIRE FIGHTING
PURPOSES I.E. FOR EMERGENCY PURPOSES WHEN POWER
FAILS IN CASE OF FIRE.
o WATER REQUIREMENTS OF A HOSPITAL INCLUDE FILTERED
HOT WATER SUPPLY TO FACULTY ROOMS,O.T.S ETC.HOT
WATER IS SUPPLIED BY A BOILER PLACED IN THE
BASEMENT.
RAIN WATER FROM ROOF IS DRAINED THROUGH VERTICAL DOWN -TAKE PVC
PIPES.
o THESE VERTICAL DOWN PIPES ARE LOCATED AT SUITABLE LOCATIONS INSIDE
THE SHAFTS.
o RAIN WATER KHURRAS HAVE BEEN PROVIDED AT ROOF LEVEL WITH 200 DIA.
RAIN WATER PIPE INLET THAT LETS VERTICAL DOWN TAKE OF RAIN WATER.
o RAIN WATER VERTICAL DOWN TAKE OF PVC PIPES ARE LEFT 75MM ABOVE
FINISHED GROUND LEVEL WITH ELBOW SPOUTS.
o UNDER THESE SPOUTS THERE ARE STORM WATER CATCH BASINS 300X300X275
TO DISCHARGE RAIN WATER DIRECTLY WITHOUT FLOODING IN SURROUNDINGS
AREAS.
oTHE CATCH BASINS ARE CONNECTED TO THE MAIN STORM WATER DRAINAGE
SYSTEM.
400 BED CIVIL HOSPITAL AT JALANDHAR
RAIN WATER HARVESTING:-
5. Residential Complex
Directors Bungalow AREA REQUIREMENT
Housing (Type A, Type B, Type C, Type
D)
AREA IN SQM.
Hostels for Nurses HOSPITAL COMPLEX 57,000
Hostels for Doctors
Hostels for Senior Residents TEACHING COMPLEX 14,500
Hostels for Students (Boys & Girls)
Public Accommodation (eg. Guest AUDITORIUM 3,500
House & Sarai)
RESIDENTIAL FACILITIES 35,000
6. Services
Electrical sub-stations and DG sets PUBLIC UTILITIES 6,000
HVAC plant room
Water Supply systems TOTAL 1,16,000 SQM
External drainage and rain water
harvesting
Waste management yards and disposal
Sewerage lines and treatment plant
COMPONENTS AND SPACE REQUIREMENTS
•DEPARTMENTS
OPD
Entrance Lobby Office
Waiting Department Office
Reception Consultants
Registration Housekeeping / Store
Record Room Administrative Section
Computer Room Admission / Discharge
Medical Social Worker Cashier
Pharmacy Public Utilities
Telephone Booth
COMPONENTS AND SPACE REQUIREMENTS
Medical Disciplines
General Medicine
Consultant Psychiatry
Examination & Workup Consultant
Treatment Room Examination & Workup
Nurses Room Nurses Room
Demonstration room
Waiting area
Surgery Orthopaedics
Consultant Consultant
Examination & Workup Dressing Room
Dressing Room Reduction Room
Minor Operation Theatre Plaster Room
Scrub and gown Xray Room
Preanaesthesia Dark Room
Sterilization Viewing
Clean Utility
Dirty Utility
Preparation
Nurses Room
COMPONENTS AND SPACE REQUIREMENTS
Ophthalmology Dentistry
Consultant •Consultant
Examination •Examination & Workup
DarkRoom •Dental X-ray
Optometry •Prosthesis lab/ workshop
Flusescence Angiography
Fluosescence Angiography Obstetrics & Gynaecology
Intra-Ocular eye co-agulation
Ophthalmic Laser •Consultant
•Examination & Workup
Otorhinolaryngology •Minor Procedures
•Consultant •Nurses Room
•Examination & Workup •Toilets
•Audiometry (Soundproof) •Samples & Record (Antenatal)
•ERA
•Ultrasound room
•Treatment/ Minor Surgery
COMPONENTS AND SPACE REQUIREMENTS
Paediatrics
•Consultant
•Examination & Workup
•Treatment Room
•Nurses Room
•Children Play Room
Speciality Clinics
(Time Sharing with others)
Entrance Lobby
Relative Waiting X-ray
Doctors Room CT Scan
Strecher Parking
Registration
Plaster Room
Office OT
Police Post
Observation/Treatment Area
Change Room
Male Doctors Rest Room Preparation
Male Doctors Toilet
Female Doctors Rest Room
Scrub
Female Doctors Toilet Resuscitation Beds
ICU
Nursing Station
Emergency Beds
Clean Utility Nurses Station
Dirty Utility
Ultra Sound Room
Emergency Lab
COMPONENTS AND SPACE REQUIREMENTS
LABORATORIES
• Laboratory • Reception
• Cytopath Lab • TMT Holter
• Metabolic Lab • Cadiologist
• Radiaisotope Lab • Record Room
• Waiting • Echo
• Cardiology ICUs • Cath Lab
• Change Room For Nurses • Console
• Dirty Utility • Store
• Clean Utility • Change Room
• Waiting • Scrub
• Urine/Stool Collection • ECG
• Record • Lift Lobby
• Path • AHU
• Laboratory • Waiting Areas
• Store • Public Utilities for Dr’s,Nurses Staff,
Patients
COMPONENTS AND SPACE REQUIREMENTS
DIAGNOSTIC ICU & DIALYSIS
•Waiting •Reception
•Record Room •Change Room
•MMR •ICU
•Reception •Staff/Support Rooms
•Reporting Room •Urology/Uro Dynamics
•Doctors Room System
•Lift Lobby •Staff Support Room
•Toilets •Reception
•MRI •Change Room
•Waiting •Tech. Room
•X-ray 2 Nos •Doctors Room
•Console •Toilets
•Change Room •Dialysis Units
•Dark Room & Auto Processor •Duty Room
•Light Lock •Nursing Station
•Ultra Sound •R.O.Plant & Dializer Reuse
•Change Room •Kidney Washer
•CT Scan •Electrical Room
•Console •AHU
COMPONENTS AND SPACE REQUIREMENTS
OT COMPLEX
WARDS ( Typical)
•Discussion Room
•Isolation
•Nursing Station
•Clean Utility
•Dirty Utility
•Nurses Rest Room
•Doctors Room
•Class IV Room
•Pantry
•Toilet
•Nursing Areas (Bed Area)
•Electrical Room
•AHU
COMPONENTS AND SPACE REQUIREMENTS
MATERNITY PAYING WARDS
CSSD
•Waiting •Decontamination Room
•Reception •Soiled store
•Record Room •Inspection, Wrap & Pack Area
•Store •Sterile store
•Laboratory •Sterile Despatch
•Bleeding •Office for Supervisor
•Recovery •ETO Room
•Doctors Room •Linen pack
•Staff Room •Steam sterliser
•Elisa •Equipment Wash
•Cold Storage •Change Room
•Washing/Sterlization •Toilet
•Pantry
•Electrical Room
•AHU
COMPONENTS AND SPACE REQUIREMENTS
SERVICES
KITCHEN LAUNDRY
Unloading Platform •Lobby
Changing Room •Distribution Area
Dietician •Clean Linen Store
Dish Wash •Laundry
Pantry •Receiving
Dry Store •Sewing Room
Manager •Sterilization
Meat Prep Area •Ladies Change Room
Veg Prep Area •Gents Change Room
Toilet •Ladies Toilet
Special Diet Room •Gents Toilet
Cold Store/ Veg.Store •Manager
Large Utensil Washing Area •Store
Trolley Bay
Trolley Washing Area
COMPONENTS AND SPACE REQUIREMENTS
SERVICES
DOCTORS CANTEEN
•Doctors Canteen
•Kitchen
•Male Change
•Ladies Toilet
•Gents Toilet
PUBLIC CANTEEN
•Public Canteen
•Kitchen
•Male Change
•Ladies Toilet
•Gents Toilet
CONFERENCE
FACILITIES
•Conference Room
•Ladies Toilet
•Gents Toilet