Line settings for Proper MD Rejection

QX QX Machine QX
Infeed Outfeed Printer MD Vision

34 20.5 28 50 30
Target speed:50TPM Mtr/Min
Mtr /Min Mtr/Min Mtr/Min Mtr/Min

Tray Movement Direction


• QX: Target Line speed-50 TPM
• In QX Preset: Motion: External Outfeed Conveyer speed:40%
• Printer Conveyer: 63.5 HZ in VFD
• Metal Detector: 50 Mtr/Min
• Rejection Delay: OFF
• Vision Camera:30 Mtr/Min
Note :Ensure above mentioned speeds are Maintained to have proper rejection In MD & Gap for Vision system