RRC Connection Establishment: 3GRPLS (RN3155) - Module 5
RRC Connection Establishment: 3GRPLS (RN3155) - Module 5
UE Node B RNC CN
AS – RB Setup
UE Node B RNC CN
AS – RB Release
UE Node B RNC
•Bit rate change
•TrCH type change
(CELL_DCH
AS – RB Re-configuration CELL_FACH)
•Measurement setup,
AS – Measurement Control configuration and release
•Handover trigger
AS – Measurement Report
•Capacity request
•CELL_FACH
AS – Physical channel re-configuration CELL_PCH
•Compressed mode
UTRAN
RRC Procedures
UE
Node B RNC
RRC Connection Management
Procedures
• Broadcast of system information
• Paging RRC Connection Mobility
• RRC connection establishment Procedures
• UE capability inquiry • Cell and URA update
• Security mode control • UTRAN mobility information
• Inter-RAT handover information • Active set update
transfer • Hard handover
• etc. • Inter-RAT cell reselection to
UTRAN
• etc.
Radio Bearer Control
Procedures
• Radio bearer establishment Measurement Procedures
• Transport channel reconfiguration • Measurement Control TS 25.331
• Physical channel reconfiguration • Measurement Report
• etc. • etc.
Soc Classification level
10 © Nokia Siemens Networks 3G RPLS / AA / 10/2008
RRC Message Structure
UTRAN
RRC Message
UE
CN IEs RNC
NAS specific information, e.g. CN type, CN domain id. Node B
UTRAN Mobility Management IEs
following e.g. Cell access restrictions, cell & URA identities
groups of UE IEs
Information UE infos, PDCP & UE RF capabilities, cell update causes,..
Elements IE
Radio Bearer IEs
can be found characteristics of a radio bearer
in RRC
messages: Transport Channel IEs
TrCh characteristics, e.g. TFCs & TFCSs.
Measurement IEs
cell measured results, event results, filter coefficients etc.
Other IEs
e.g. Inter-RAT UE radio access capability,..
UE Node B RNC
L1 Synchronisation
UE RNC
Measurement
results for if FDD SFN –
monitored cells SFN observed
time difference
RRC layer
RB Radio Bearer
configuration
PDCP BMC
RLC
LogCH
TrCH
configuration MAC
TrCH
PhyCh
configuration PHY
PhyCH
Soc Classification level
28 © Nokia Siemens Networks 3G RPLS / AA / 10/2008
RRC Connection Setup message: RB IEs
RRC Connection Setup ( )
RNC
UE
UE IEs
RB IEs
RRC
Radio Link Control
configuration
• Transfer of user data
• Segmentation and reassembly.
• Concatenation and padding
• Sequence number check
• In-sequence delivery of upper layer PDUs
• Duplicate detection
• Error correction
• Flow control
• Ciphering
• Protocol error detection and recovery
LogCH
Soc Classification level
32 © Nokia Siemens Networks 3G RPLS / AA / 10/2008
RLC Modes of Operation
Radio Bearer
Transparent Mode Unacknowledged Acknowledged
(TrM) Mode (UM) Mode (AM) RLC
op
RRC layer tio
na
l
MAC
UE IEs
Signalling RB
RB IEs information 3/4
to setup list
TrCH IEs: UL/DL
Signalling RB
Information RB identity 1..32 (values 1..4
PhyCH IEs: UL/DL
to setup
for signalling bearers
CHOICE RLC only)
info type
UE IEs
RB IEs
LogCHs
TrCHs
0 1 0 1 0 1 0 1 0 1 0 1
RLC PDU
MAC MAC Header MAC
TrCH
MAC PDU
Defined by TFS
LogCH LogCH
Transport Format Set
0 1 0 1
Semi-Static Part
• TTI
• Channel Coding
• CRC size
• Rate matching allowed TFs
on this dedicated
Dynamic TF Information TrCH MAC
• RLC Size
• •Number
TrCH
RLC Size
of Transport Blocks
• RLC Size
• Number of Transport Blocks
• •Number
RLC Size
of Transport Blocks
• •Number
RLC Size
of Transport Blocks
• Number of Transport Blocks
Soc Classification level
42 © Nokia Siemens Networks 3G RPLS / AA / 10/2008
RRC Connection Setup message: TrCH IEs
RRC Connection Setup ( )
UE
(OP) (should not be used
UE IEs PRACH TFCS since TS25.331 V3.7.0)
This is for Rel 99
RB IEs DCH CHOICE FDD
RNC
TFC subset
TrCH IEs: UL/DL Uplink
UL DCH TFCS
PhyCH IEs: UL/DL
UL Transport channel
information common for
all transport channels Indicates allowed combinations
1 to maxTrCH (32) of already defined TFs and
(max. allowed TrCHs
in one direction) Added or Reconfigured their TFCI values
TrCH information list
UE
(OP) (should not be used
UE IEs SCCPCH TFCS since TS25.331 V3.8.0)
DL Transport channel
information common for 1 to maxTrCH (32)
(max. allowed TrCHs in one direction)
all transport channels
Added or Reconfigured
TrCH information list • DL TrCH type (DCH)
• DL TrCH identity
This is for Rel 99 Added or Reconfigured • TFS
DCH DL TrCH information • DCH quality target
(BLER quality value on a log10 scale:
-6.3..0, step size: 0.1)
Soc Classification level
44 © Nokia Siemens Networks 3G RPLS / AA / 10/2008
RRC Connection Setup message: PhyCH IEs
RRC Connection Setup ( )
RNC
UE
UE IEs
RB IEs
DL radio resources
TrCHs
PhyCHs
Soc Classification level
47 © Nokia Siemens Networks 3G RPLS / AA / 10/2008
RRC Connection Setup message: PhyCH IEs for UL
RRC Connection Setup ( )
RNC
UE
UE IEs
RB IEs
(OP)
Uplink DPCH info CPCH SET info
(OP-Option)
Soc Classification level
48 © Nokia Siemens Networks 3G RPLS / AA / 10/2008
RRC Connection Setup message: Uplink DPCH info
Uplink DPCH info
UE IEs
RB IEs
Downlink information
1..MaxRL (8)
per radio link list
Downlink infor-
mation for each
radio link
Downlink
Uplink DPCH
DPCHinfo
info Single TPC (DPC_Mode = 0) /
Downlink DPCH power
common for all RL
control information TPC triplet in soft (DPC_Mode =1)
CHOICE FDD CHOICE FDD
0..6 dB, step size 0.25
DPCH compressed Power offset PPilot-DPDCH
mode info Lists TFI of DCHs & DSCHs, which
Downlink rate matching have DL rate matching restrictions;
restriction information rate matching should be done on
TFCs of „DL TFCS with no restricted
Spreading factor Transport Channel“
SIB type
SIBs only 1 to maxSIB-FACH (8)
(max number of references
to SIB on one FACH)
Soc Classification level
55 © Nokia Siemens Networks 3G RPLS / AA / 10/2008
Part IV
RRC Connection Setup Complete
• Transport channel capability: is distributed to the resource manager and to the admission
control entity
• RF capability: the RF capability is distributed to the resource manager, the power control
entity and to the handover control entity
• Physical channel entity: is distributed to resource manager
• UE multi-mode/multi-RAT capability
• Security capability
• LCS capability
• Measurement capability: is distributed to the handover control entity.
• Presence is mandatory if IE Multi-mode capability has the value "FDD" or "FDD/TDD"
and a FDD capability update has been requested in a previous message.
• Otherwise this field is not needed in the message.
• Among the optional other information elements, we find the Inter_RAT UE access capability. The
RNC shall extract the inter-system message from the UE CAPABILITY INFORMATION message
and transfer it to the handover control entity.
N300:
0..7; def.: 3
RRC Connection Setup
no V300 N300
message received with
initial UE identity
no yes yes
UE RNC
CELL_FACH state; RRC Connection Release [RLC-UM, DCCH]
DCCH available
[RLC-AM, DCCH] RRC Connection Release Complete
UE RNC
• WCEL: N300
• The RRC Connection Request retransmission counter (MS counter).
• This parameter is part of SIB 1.
• [0 ... 7]; default: 3.
• RNC: T308
• The RRC Connection Release Complete retransmission timer.
• This parameter is part of SIB 1.
• [40, 80, 160, 320]ms; default: 160ms.
• RNC: N308
• This counter is used to define the maximum number of retransmissions of the RRC CONNECTION
RELEASE COMPLETE message by the MS when the MS is in CELL_DCH state.
• [1 ... 8]; default: 2.
UE RNC
Physical Channel Reconfiguration [RLC-AM/UM, DCCH]
RRC
Physical Channel Reconfiguration Complete [RLC-AM, DCCH]
PDCP/BMC
UE RNC
RLC
Physical Channel Reconfiguration [RLC-AM/UM, DCCH]
configuration
PHY
PhyCHs
Soc Classification level
68 © Nokia Siemens Networks 3G RPLS / AA / 10/2008
Transport Channel Reconfiguration on existing
RBs
UE RNC
Transport Channel Reconfiguration [RLC-UM/AM, DCCH]
RRC
Transport Channel Reconfiguration Complete [RLC-AM, DCCH]
PDCP/BMC
UE RNC
RLC
Transport Channel Reconfiguration [RLC-UM/AM, DCCH]
configuration
TrCHs
PHY
PhyCHs
Soc Classification level
69 © Nokia Siemens Networks 3G RPLS / AA / 10/2008
RB Setup, Reconfiguration, and Release
UE RNC
Radio Bearer Setup [RLC-AM/UM, DCCH]
PDCP/BMC UE RNC
Radio Bearer Reconfiguration [RLC-AM/UM, DCCH]
RLC
configuration
PHY