Rankine with 3 FHWs

Find the performance of a Rankine cycle


with re-heater, 3 closed feed water heaters.
Boiler pressure is 5 MPa at 400 C, o

condenser pressure is 30 kPa. The re-


heater pressure is 0.8 MPa and the
extracted pressure for HPT and LPT are at
optimum, Take TDD = 2.0 for all closed
feed water heater:
Draw a block and T-s diagram
Energy Balance for each feed water heater:

For HP CFWH:

m1h2  h16  m1h17  h19


m1 (h2  h17 )  h19  h16
h19  h16
m1 
h2  h17
For IP CFWH:

m 2 h 5  m1h18  h13  (m1  m 2 )h14  h16


m 2 h 5  m1h18  h13  m1h14  m 2 h14  h16
m 2 (h 5  h14 )  m1 (h18  h14 )  h13  h16  0
m 2 (h 5  h14 )   m1 (h18  h14 )  h13  h16
 m1 (h18  h14 )  h13  h16
m2 
h 5 h14
For LP CFWH:

m 3 h6  h9  (m1  m 2 )h15  h12  (m1  m 2  m 3 )h10


m 3 h6  h9  m1h15  m 2 h15  h12  m1h10  m 2 h10  m 3h10
m 3 (h6  h10 )  m 2 (h15  h10 )  m1 (h15  h10 )  h9  h12
m 3 (h6  h10 )  h12  m 2 (h15  h10 )  m1 (h15  h10 )  h9
h12  m 2 (h15  h10 )  m1 (h15  h10 )  h9
m3 
(h6  h10 )