You are on page 1of 24

WATER SUPPLY & SANITARY PROJECT

CONTENTS
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Introduction Population forecasting Calculation of total demand Design of rising main and its pump house Capacity of OHSR and Pump set Design of feeder main Distribution layouts Design of circular water tank Estimation of Sewage Materials for Sewers Sewer appurtenances Design parameters

1) Name of the project: 2) State/District/Taluka

:Water supply and Sanitation :Bijapur (HUDCO Colony) :10.00 KM : 6.00 KM : 4.00 KM

3) Location a) Distance of project site from the city b) The nearest Railway station and its distance from the project site c) Distance of project site from collage

Colony map Profile levelling for center line of Main Pipe line Cross-Sections for the center line of Pipe line Profile Levelling for distribution system

` ` ` `

Dumpy level Prismatic Compass Plane Table and its Accessories Chain, Tape, Arrows and Ranging Rods

Components Designed a. Prediction of Population b. Calculation of Discharge c. Design of Rising Main d. Design of Distribution system e. Design of OHSR

` `

Present Population= PO=900 Forecast for next 30 years by geometric increase method Total population Pn= 1555

r Pn ! P0 1  100

CALCULATION FOR WATER SUPPLY:

CALCULATION FOR TOTAL DEMAND a) Intermediate demand Population after 15 years =1188 Q = 1188*155 = 0.184 MLD b) Ultimate demand Q = 1555 * 155 = 0.241MLD

OVERALL LAYOUT OF WATER SUPPLY SYSTEM

` ` ` ` ` `

Diameter of Pipe Velocity Slope Head Loss Total head Horse Power of Motor

= 100mm = 0.54m/sec = 4.506*10-3 = 4.506m = 47.86m = 6 KW

THE HEAD LOSS ARE CALCULATED BY HAZENS WILLIAMS RELATION

DESIGN HEAD FOR CALCULATION OF PUMP SET CAPACITY = STATIC HEAD + FRICTION LOSS +SUCTION HEAD = 55.75 M

ASSUMING EFFICIENCY OF PUMP = 75 % THEREFORE CAPACITY OF PUMP SET = 4.22 HP WITH CAUTION OF 15% FOR WEAR & TEAR OF PUMP CAPACITY REQUIRED = 4.85 HP THUS PROVIDE PUMP SET OF 5HP

` `

WE HAVE ULTIMATE DISCHARGE = 0.241 MLD THE OHSR MUST HAVE CAPACITY TO HOLD HALF OF THE PER DAY DEMAND THUS CAPACITY OF OHSR = 0.241 / 2 = 0.1205 MLD = 120.5 m THUS PROVIDE CAPACITY OF OHSR = 150 m

THE WATER DISTRIBUTION SYSTEM IS DESIGNED WITH THE HELP OF LOOP 4.0 VERSION SOFTWARE. THE MINIMUM AND MAXIMUM PRESSURE HEAD IS MAINTAINED IN EACH PIPE OF 7M AND 22M RESPECTIVELY

` ` `

` `

DIAMETER OF THE PUMPING MAIN = 100 MM DIAMETER OF THE FEEDER MAIN = 110 MM DAIMETER OF SUB-DISTRIBUTION PIPES = 90 MM & 75 MM CAPACITY OF THE PUMP SET = 5 HP CAPACITY OF THE OHSR = 150 m

` `

Present Population= PO=900 Forecast for next 30 years by geometric increase method Total population Pn= 1555

r Pn ! P0 1  100

1. CONSERVANCY SYSTEM 2. WATER CARRIAGE SYSTEM

` ` ` ` ` ` ` `

CATCHMENT AREA GROUND SLOPE PERMEABILITY OF SOIL EXTENT OF IMPERVIOUS AREA ROAD SURFACE & VEGITATION RAINFALL INTENSITY MOISTURE CONTENT OF SOIL CLIMATIC CONDITIONS

SEWER APPURTENANCES

Deep

le Dr l

Design of Main Sewer ` Maximum sewage discharge ` Average Velocity ` Diameter of sewer ` Sewer slope Branch Sewer ` Maximum sewage discharge ` Average Velocity ` Diameter of sewer ` Sewer slope

= 6.93 x10-3 cumecs = 0.45m/sec = 150mm = 1: 430 = 3.465x10-3 cumecs = 0.45 m/sec = 100mm = 1: 250

Man Hole Provide a shallow manhole of depth 0.8m, and 0.75m diameter. Since diameter of the sewer is less than 0.3m, providing manholes at every 45m spacing. Septic Tank Capacity of Tank Area of Tank Size

= 877.5 m3 = 337.5 m2 = 22.5mx15mx2.6m

THANK-U